SCORE 96 315 Decatur St, New Orleans, La 70130 Replace existing flat roof on green rated property:remove white modified membraneinstall insulationinstall grey genflex tpo peel and stick membrane systemmodify through wall scuppers, restore to original size (approx. 6"x6")install termination flashingnote: trash chutes are required for removal of debris from all roofs all work must conform to standard vcc policies & guidelines permit does not allow for cap flashing on parapet or surrounding wallstorch-applied roofing is not permitted in the vieux carr. Permit type: Vcc general work | Permit status: Permit issued | Expiration date: November 7, 2015 | Current use: Mixed use | Permit id: 15-10445-Vcgen | |||||
SCORE 96 625 Burgundy St, New Orleans, La 70112 Replace storm damaged slates with like, to match existing. Re-seal existing parapet wall cap. Date: October 5, 2012 Contractor: Robertson Roofing Inc Permit type: Vcc general work | Permit status: Permit finaled | Completion date: December 12, 2014 | Expiration date: April 5, 2013 | Current use: Multi-family | Permit id: 12-26392-Vcgen | |||||
SCORE 96 Permit type: Renovation (non-structural) | Permit status: Permit issued | Expiration date: May 18, 2014 | Current use: Multi-family | Permit id: 13-39879-Rnvn | |||||
SCORE 96 Permit type: Renovation (non-structural) | Permit status: Permit approved | Current use: Unknown | Permit id: 14-36200-Rnvn | |||||
SCORE 96 315 Chartres St [crystalmen], New Orleans, La Roof: remove broken fire free roofing tiles seal the openings and cracks in the flashing cement on the blind valley, around the dormers, along two (2) parapet walls, and around chimneys with fiberglass mesh and flashing cement use vcc approved mortar mix (below) replace 6 jack cap where missing replace with natural vermont slate to match size of existing dormers: install new painted steel apron flashing on two (2) dormers on the exchange alley roof elevation clean and prime the seams in the blind valley with an asphalt base primer seal the seams in the blind valley with modified membrane and cold process adhesive caulk and paint the window sills on both dormers, to match existingwhite balcony: install a painted steel threshold on the two (2) doors on the balcony, set in a high performance urethane sealant remove loose caulking between the door frames and the wall and re-seal with a high performance urethane sealant sand, caulk, and paint threshold around one (1) door frame used to acce Date: December 12, 2013 Contractor: Robertson Roofing Inc Permit type: Vcc general work | Permit status: Permit issued | Expiration date: June 13, 2014 | Current use: Business use | Permit id: 13-47594-Vcgen | |||||
SCORE 96 635 S Peters St, New Orleans La Work descripton: remove build up roof and install new roll roof as per hdlc letter dated april 4, 2012. Historical import type: permits commercial renovation (structural) na user: rmaxwell tracking: 86161352668 status: permit issuance active status date: 4/4/2012 12:00: am owner: economy ironworks inc owner address: 635 s peters st, new orleans, la 701 owner edited by: 4/4/2012 by rmaxwell Permit type: Renovation (structural) | Permit status: Permit issuance - active | Current use: Business use | |||||
SCORE 96 Client: Aurelio J Montenegro, Edwin D Cooper, Judy L Andrews, Alicia K Zervigon, Craig B Hallenstein, Surfac | Permit type: Renovation (non-structural) | Permit status: Permit issued | Current use: Multi-family | |||||
SCORE 96 635 S Peters St, New Orleans La Work descripton: remove build up roof and install new roll roof as per hdlc letter dated april 4, 2012. Historical import type: permits commercial renovation (structural) na user: rmaxwell tracking: 86161352668 status: permit issuance active status date: 4 4 2012 12:00: am owner: economy ironworks inc owner address: 635 s peters st, new orleans, la 701 owner edited by: 4 4 2012 by rmaxwell Permit type: Renovation (structural) | Permit status: Permit issuance - active | Current use: Business use | |||||
SCORE 96 Permit type: Renovation (non-structural) | Permit status: Permit approved | Current use: Multi-family | Permit id: 17-20116-Rnvn | |||||
SCORE 96 718 St Philip St, New Orleans, La 70116 Remove damaged and broken slate as needed,remove/repair existing flashing as neededinstall self adhering ice and water membrane underlaymentinstall new 16 oz copper wall, base, apron, and counter flashing as neededinstall new natural slate (grey/green), using copper nailsinstall/repair copper gutters, flashing and vents. Install parapet mortar cap, using vcc approved mortar formula with embedded meshinstall/reinstall ceramic or concrete v-style or terra cotta ridge tilesmetal cap-flashing on the parapets is not allowednote: trash chutes are required for removal of debris from all roofs all work must conform to standard vcc policies & guidelines permit does not allow for cap flashing on parapet or surrounding walls permit does not allow masonry sealanttorch-applied roofing is not permitted in the vieux carr. Permit type: Vcc general work | Permit status: Permit issued | Expiration date: December 17, 2015 | Current use: Half of a party wall double | Permit id: 15-17807-Vcgen | |||||
SCORE 96 1031 Barracks St, New Orleans, La 70116 Replacement of 2 fire free roof slates on main building; install flashing at dormer on main building; remove and replace 2 ply cold-applied flat roof, 2 s. F., on rear brown-rated first floor roof. Emergency repair permit requested due to leaks in both locations. Remove existing asbestos shingle roofing. Repair and/or replace underlayment as necessary. Install/repair flashing and vents, to match existing. Install new lamarite synthetic slate roofing, dark gray in color, with underlayment in accordance with manufacturers instructions for class a fire rating. Reinstall existing ridge tiles. Note: trash chutes are required for removal of debris from all roofs all work must conform to standard vcc policies & guidelinespermit does not allow for cap flashing on parapet or surrounding wallstorch-applied roofing is not permitted in the vieux carr. Permit type: Renovation (non-structural) | Permit status: Permit approved | Current use: Multi-family | Permit id: 16-02664-Rnvn |