Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
SCORE 100 2838 S 15th St Philadelphia Pa 191454915 Addition to front and back of 2nd floor and complete rewire with recepts,switches,lights,fixtures,smoke and co derectors as per 2008 nec (south district) ![]() ![]() Client: Lombardo Diavid R Lombardo Michelle C | Permit type: Electrical permit | Permit status: Expired | Completion date: May 12, 2017 | Permit id: 783231 | |||||
SCORE 100 2823 S 16th St Philadelphia Pa 191454918 Install 200a service, ckt panel, all proper grounding, smokes and co dets, and complete rewiring in accordance with 2008 nec(sfd)(south dist) ![]() ![]() Client: Llon Roy Dillon Tara | Permit type: Electrical permit | Permit status: Completed | Completion date: August 10, 2013 | Permit id: 430811 | |||||
SCORE 100 1531 S 8th St Philadelphia Pa 191476401 200amp service,complete rewiring throughout,smoke and c o detectors per 2008 nec (sfd)south district ![]() ![]() Client: Termini Vincent A Sr Tr Termini Barbara R Tr | Permit type: Electrical permit | Permit status: Completed | Completion date: April 27, 2016 | Permit id: 657966 | |||||
SCORE 100 2225 Trenton Ave Philadelphia Pa 19125 2 amp service, grounding, smoke and c. O detectors, complete wiring throughout, 2008 nec ![]() ![]() Permit type: Electrical permit | Permit status: Completed | Completion date: October 16, 2015 | Permit id: 622235 | |||||
SCORE 100 1 Jackson St Philadelphia Pa 191483336 200amp service,total house wire as per 2008 nec,smoke detectors,c o detectors as per 2008 nec ![]() ![]() Client: Hartman William Hartman Christine | Permit type: Electrical permit | Permit status: Completed | Completion date: October 6, 2011 | Permit id: 320844 | |||||
SCORE 100 1849 Blair St Philadelphia Pa 19125 Electrical construction for a new single-family dwelling - 200amp electrical service, all proper grounding, smoke and c o detectors and complete wiring throughout - all work will comply with the 2009 irc and the 2008 nec for a single-family dwelling ![]() ![]() Permit type: Electrical permit | Permit status: Completed | Completion date: June 19, 2014 | Permit id: 517355 | |||||
SCORE 100 135 Gladstone St Philadelphia Pa 191484014 1 amp service, all proper grounding, smoke,c o detectors total wiring as per nec 2008 (sfd) ![]() ![]() Client: Naimoli Christopher | Permit type: Electrical permit | Permit status: Completed | Completion date: July 20, 2013 | Permit id: 458627 | |||||
SCORE 100 2231 Trenton Ave Philadelphia Pa 19125 Install new 200amp service complete with grounding wiring, swiltches, recepts, lights smoke, c o det, as per 2008 nec (east district) ![]() ![]() Permit type: Electrical permit | Permit status: Completed | Completion date: December 17, 2015 | Permit id: 632096 | |||||
SCORE 100 1702 Latona St Philadelphia Pa 191463028 150a service, cicuit panels, all proper grounding, smoke and co dets, complete rewire as per 2008 nec(sfd)(south dist) ![]() ![]() Client: Ranz Kristi J Ranz Dylan O | Permit type: Electrical permit | Permit status: Completed | Completion date: July 23, 2012 | Permit id: 403690 | |||||
SCORE 100 1854 Frankford Ave Philadelphia Pa 19125 Install 200amp underground service, 3 sub-panels, complete wiring throughout smoke and c o detectors (fire alarm done by others) as per 2008 nec (east district) ![]() ![]() Permit type: Electrical permit | Permit status: Completed | Completion date: July 12, 2017 | Permit id: 668363 | |||||
SCORE 100 2341 S 16th St Philadelphia Pa 191454403 Complete rewire of sfd - 2 amp service - grounding and bonding - smoke and co detectors - as as per 2008 nec ![]() ![]() Client: Hagedorn Paul A Hagedorn Fern Lee | Permit type: Electrical permit | Permit status: Expired | Completion date: April 23, 2015 | Permit id: 603862 | |||||
SCORE 100 1736 Watkins St Philadelphia Pa 191452119 100amp service, all proper grounding, smoke and c o detectors. Complete rewiring. All work done as per 2008 nec south district ![]() ![]() Client: Boujaoude Ziad Aboujaoude Rania | Permit type: Electrical permit | Permit status: Completed | Completion date: February 6, 2017 | Permit id: 701232 | |||||
SCORE 100 7 S 6th St Philadelphia Pa 191473040 Install 200amp service all proper grounding and bonding and complete rewire with recepts,switches,lights,fixtures,smoke and co derectors as per 2008 nec (south district) ![]() ![]() Client: Mima Luju Llc | Permit type: Electrical permit | Permit status: Completed | Completion date: October 23, 2017 | Permit id: 783230 | |||||
SCORE 100 1302 S 7th St Philadelphia Pa 191475804 Install recepst, switches, lights, smoke and co detectors on to existing 200amp service as per 2005 nec (south district) ![]() ![]() Client: Cullen Kimberly Anne Lynch Jonathan D | Permit type: Electrical permit | Permit status: Completed | Completion date: May 22, 2012 | Permit id: 358001 | |||||
SCORE 100 18 Titan St Philadelphia Pa 191462927 Install 100amp service complete with grounding , all outlets, switches, recessed lights, hardwire smoke and carbon monoxide detectors,m dedicated lines for refrigerator, micro, dishwasher, washer, dryer, hot tub garbage disposal and central ac as per 2005 nec (south district) ![]() ![]() Client: Stanczyk Alexis | Permit type: Electrical permit | Permit status: Expired | Completion date: August 13, 2009 | Permit id: 231839 | |||||
SCORE 100 ![]() ![]() Client: Cullen Kimberly Anne Lynch Jonathan D | Permit type: Electrical permit | Permit status: Expired | Completion date: March 31, 2011 | Permit id: 331331 | |||||
SCORE 100 23 S 3rd St Philadelphia Pa 191484026 150amp electrical service,all proper grounding complete rewrite,smoke and c o detectors per 2008 nec (sfd) ![]() ![]() Client: Smith Tracy | Permit type: Electrical permit | Permit status: Expired | Completion date: October 14, 2016 | Permit id: 729252 | |||||
SCORE 100 10 S 2nd St Philadelphia Pa 191474205 Install 350amp service, 4 gang meter, 4 sub panels, all proper grounding and bonding, complete rewire with recepts,switches,lights,fixtures,smoke and co derectors as per 2008 nec (south district) ![]() ![]() Client: &b Homes Llc | Permit type: Electrical permit | Permit status: Completed | Completion date: October 23, 2017 | Permit id: 787116 | |||||
SCORE 100 1929 S 13th St Philadelphia Pa 191482202 1 amp service, circuit breaker panel, all proper grounding as per 2008 nec ![]() ![]() Client: Hernandez Santos | Permit type: Electrical permit | Permit status: Expired | Completion date: April 28, 2011 | Permit id: 338082 | |||||
SCORE 100 1641 Titan St Philadelphia Pa 191463031 150amp service, circuit panel, all proper grounding smoke detectors, total wiring of property as per 2008 nec (south district) single family dwelling ![]() ![]() Client: Brenes Tamara | Permit type: Electrical permit | Permit status: Completed | Completion date: August 6, 2012 | Permit id: 391635 | |||||
SCORE 100 1244 S 17th St Philadelphia Pa 191463043 200amp service, grounding, complete wiring, smokes, c o detectors as per nec 2008 (sfd) ![]() ![]() Client: Robison John Paul Ezra Robison Shi | Permit type: Electrical permit | Permit status: Expired | Completion date: July 16, 2013 | Permit id: 483506 | |||||
SCORE 100 12 S 17th St Philadelphia Pa 191463043 200amp service, 3 gang meter socket, 3 sub-panels, all proper grounding, smoke c o detectors, total wiring as per 2008 nec (duplex) ![]() ![]() Client: Lemay Greg Lemay Joanne | Permit type: Electrical permit | Permit status: Completed | Completion date: January 28, 2013 | Permit id: 438641 | |||||
SCORE 100 2605 S 17th St Philadelphia Pa 191454501 Install 100amp service complete with pemter, panel & grounding, rewire and install new device switches, recepts, lights, smoke and c o detectors n& door bell as per 2008 nec (south district) ![]() ![]() Client: Hodge Thomas J Jr Hodge Elizabeth G | Permit type: Electrical permit | Permit status: Active | Completion date: October 20, 2017 | Permit id: 825627 | |||||
SCORE 100 1347 S 20th St Philadelphia Pa 191464642 200amp service all proper grounding complete rewire, smoke and c o detectors per 2008 nec (sfd) ![]() ![]() Client: Kim Peter T Ly David | Permit type: Electrical permit | Permit status: Completed | Completion date: December 10, 2013 | Permit id: 474927 | |||||
SCORE 100 2227 Trenton Ave Philadelphia Pa 19125 2 amp service,grounding,smoke detector and c o,complete wiring throughout per 2008 nec(sfd) ![]() ![]() Permit type: Electrical permit | Permit status: Expired | Completion date: October 16, 2015 | Permit id: 622237 | |||||
SCORE 100 1519 Earl St Philadelphia Pa 191252603 Complete rewire and replace 100amp service,all proper grounding and bonding,smoke and c o detectors as per 2005 nec (east district) ![]() ![]() Client: Janssen Gene J Janssen Margarita M | Permit type: Electrical permit | Permit status: Completed | Completion date: February 10, 2015 | Permit id: 564882 | |||||
SCORE 100 1856 Frankford Ave Philadelphia Pa 19125 Complete wiring throughout,2 amp underground service,3 panels,smoke and c o detectors per 2008 nec (mixed use) no fire alarm east district ![]() ![]() Permit type: Electrical permit | Permit status: Completed | Completion date: April 29, 2016 | Permit id: 657968 | |||||
SCORE 100 1859 Blair St Philadelphia Pa 19125 200amp service,all proper grounding and bonding,smoke and c o detectors,complete wiring per 2008 nec (sfd) ![]() ![]() Permit type: Electrical permit | Permit status: Completed | Completion date: January 26, 2015 | Permit id: 571951 | |||||
SCORE 100 1853 Blair St Philadelphia Pa 19125 200amp service all proper grounding,smoke co detectors,complete wiring throughout per 2008 nec (sfd) ![]() ![]() Permit type: Electrical permit | Permit status: Completed | Completion date: September 15, 2014 | Permit id: 543514 | |||||
SCORE 100 2221 Trenton Ave Philadelphia Pa 19125 Temporary 100amp service for construction site on pole with guad outdoor outlet gfci protected from 2 2 16 to 7 2 15 ![]() ![]() Permit type: Electrical permit | Permit status: Expired | Completion date: June 12, 2015 | Permit id: 587648 | |||||
SCORE 100 2229 Trenton Ave Philadelphia Pa 19125 Install new 200amp service complete with grounding wiring, swiltches, recepts, lights smoke, c o det, as per 2008 nec (east district) ![]() ![]() Permit type: Electrical permit | Permit status: Completed | Completion date: November 10, 2015 | Permit id: 632095 | |||||
SCORE 100 1855 Blair St Philadelphia Pa 19125 200amp service all proper grounding,smoke co detectors,complete wiring throughout per 2008 nec (sfd) ![]() ![]() Permit type: Electrical permit | Permit status: Completed | Completion date: September 15, 2014 | Permit id: 543516 | |||||
SCORE 100 18 Frankford Ave Philadelphia Pa 19125 Complete wiring throughout, 200amp underground serv, 3-panels, smoke & c o detectors throughout, fire alarm by others, as per nec 2008 east dist see log bonding as per article 250. 102(c) of the 2008 nec. ![]() ![]() Permit type: Electrical permit | Permit status: Expired | Completion date: November 19, 2014 | Permit id: 569147 | |||||
SCORE 100 1935 E Moyamensing Ave Philadelphia Pa 191482526 200amp service, circuit panel, all proper grounding smoke & carbon detectors, total wiring of property as per 2008 nec (south district) single family dwelling ![]() ![]() Client: Neill Gary Neill Alexis | Permit type: Electrical permit | Permit status: Completed | Completion date: December 5, 2012 | Permit id: 391632 | |||||
SCORE 100 18 Frankford Ave Philadelphia Pa 191252416 Temporary 100amp electrical service for construction site (sfd)east district ![]() ![]() Permit type: Electrical permit | Permit status: Completed | Completion date: November 21, 2015 | Permit id: 649002 | |||||
SCORE 100 1849 Blair St Philadelphia Pa 19125 Temp 1 amp service, 4-ckt panel, 2-gfci outlets each on dedicated line all equipment outdoor rated from 7 17 13 to 7 13 14 as per nec 2008 (construction site) ![]() ![]() Permit type: Electrical permit | Permit status: Expired | Completion date: July 16, 2013 | Permit id: 483507 | |||||
SCORE 100 127 Emily St Philadelphia Pa 191482607 Install 100amp service complete with pemter, panel & grounding, rewire and install new device switeche, recepts, lights, smoke and c o detectors n& door bell as per 2008 nec (south district) ![]() ![]() Permit type: Electrical permit | Permit status: Active | Completion date: October 20, 2017 | Permit id: 825625 | |||||
SCORE 100 1857 Blair St Philadelphia Pa 19125 200amp service all proper grounding,smoke co detectors,complete wiring throughout per 2008 nec (sfd) ![]() ![]() Permit type: Electrical permit | Permit status: Completed | Completion date: October 20, 2014 | Permit id: 543517 | |||||
SCORE 100 1862 Frankford Ave Philadelphia Pa 191252416 Complete wiring throughout,200amp underground service,3 panels smoke and co detectors throughout,all proper grounding and bonding all work as per 2008 nec (east district) ![]() ![]() Client: Happy Investments Llc | Permit type: Electrical permit | Permit status: Completed | Completion date: June 12, 2015 | Permit id: 578799 | |||||
SCORE 100 2223 Trenton Ave Philadelphia Pa 19125 2 amp service, smoke and co detectors. Complete wiring throughout as per 2008 nec and the 2009 irc for a new attached single-family dwelling ![]() ![]() Permit type: Electrical permit | Permit status: Completed | Completion date: August 22, 2015 | Permit id: 610426 | |||||
SCORE 100 1852 Frankford Ave Philadelphia Pa 191252416 Install 200amp underground service, 3 sub-panels, complete wiring throughout, smoke and c o detectors (fire alarm done by others) as per 2008 nec (east district) ![]() ![]() Permit type: Electrical permit | Permit status: Completed | Completion date: August 17, 2016 | Permit id: 668362 | |||||
SCORE 100 2211 S Lambert St Philadelphia Pa 191453520 Replace 1 amp service entrance cable and meter socket, install grounding rod and install ground to cold water pipe per 2008 nec (sfd)south district ![]() ![]() Client: Tran My Linh Sanchez Julio | Permit type: Electrical permit | Permit status: Completed | Completion date: November 5, 2015 | Permit id: 645661 | |||||
SCORE 100 2329 Federal St Philadelphia Pa 191462423 150amp service, circuit panel, all proper grounding smoke & c o detectors, complete rewire as per nec 2008 (sfd) ![]() ![]() Client: Riggar William Brodie Barbara F | Permit type: Electrical permit | Permit status: Completed | Completion date: July 20, 2013 | Permit id: 466763 | |||||
SCORE 100 1908 Latona St Philadelphia Pa 191462921 Install 200amp service, complete wiring throughout, smoke and c o detectors as per 2008 nec (west district) ![]() ![]() Client: Fiorenza Bruno Fiorenza Marisa | Permit type: Electrical permit | Permit status: Completed | Completion date: May 29, 2016 | Permit id: 668360 | |||||
SCORE 100 1858 Frankford Ave Philadelphia Pa 19125 Complete wiring throughout,2 amp underground service,3 panels,smoke and c o detectors per 2008 nec (mixed use) no fire alarm east district ![]() ![]() Permit type: Electrical permit | Permit status: Completed | Completion date: April 14, 2016 | Permit id: 657970 | |||||
SCORE 100 1861 Blair St Philadelphia Pa 19125 200amp service,all proper grounding and bonding smoke and c o detectors,complete wiring per 2008 nec (sfd) ![]() ![]() Permit type: Electrical permit | Permit status: Completed | Completion date: February 10, 2015 | Permit id: 575174 | |||||
SCORE 100 702 Mollbore Ter Philadelphia Pa 191485034 Replace circuit breaker panel all proper grounding, complete rewire, smoke and c o detectors as per nec 2008 south district ![]() ![]() Client: Kalesse Nicole B Dettore Joseph | Permit type: Electrical permit | Permit status: Completed | Completion date: April 25, 2017 | Permit id: 749899 | |||||
SCORE 100 2221 Trenton Ave Philadelphia Pa 19125 2 amp service, smoke and co detectors. Complete wiring throughout as per 2008 nec and the 2009 irc for a new attached single-family dwelling ![]() ![]() Permit type: Electrical permit | Permit status: Completed | Completion date: August 19, 2015 | Permit id: 610428 | |||||
SCORE 100 2647 S Colorado St Philadelphia Pa 191454508 Complete rewire of sfd - 2 amp service - grounding and bonding - smoke and co detectors - as as per 2008 nec ![]() ![]() Client: Bongiovanni Marc | Permit type: Electrical permit | Permit status: Expired | Completion date: April 20, 2015 | Permit id: 603861 | |||||
SCORE 100 1163 S Darien St Philadelphia Pa 191475136 Complete rewire, smoke & c o detectors as per nec 2008 (sfd) ![]() ![]() Client: Priest Kevin J | Permit type: Electrical permit | Permit status: Completed | Completion date: August 3, 2013 | Permit id: 466762 | |||||
SCORE 100 ![]() ![]() Client: Aponte Leon Aponte Frances | Permit type: Electrical permit | Permit status: Completed | Completion date: January 8, 2014 | Permit id: 491025 | |||||
SCORE 100 1719 Lombard St Philadelphia Pa 191461518 Upgrade electrical service 200a,wire and install 35recessed light fixtures,replace all switches and recepts,install gfci recepts as needed,complete wiring of new kitchen as per 2008 nec(south district) ![]() ![]() Client: Buzi Adva | Permit type: Electrical permit | Permit status: Completed | Completion date: August 19, 2015 | Permit id: 596396 | |||||
SCORE 100 2325 Ellsworth St Philadelphia Pa 191462419 150amp service all proper grounding, total wiring smoke and carbon monixide detectors, arc faults & gfci as per 2008 nec (south district) single family dwelling ![]() ![]() Client: Yasso Joseph Yasso Tara | Permit type: Electrical permit | Permit status: Completed | Completion date: May 22, 2012 | Permit id: 378440 | |||||
SCORE 100 926 Greenwich St Philadelphia Pa 191476319 150amp service all proper grounding,complete rewire smoke and c o detectors per 2008 nec (sfd)south district ![]() ![]() Client: Skeehan Danielle | Permit type: Electrical permit | Permit status: Expired | Completion date: October 14, 2016 | Permit id: 729249 | |||||
SCORE 100 16 Jackson St Philadelphia Pa 191453845 Install 400amp service, 4 meters, 4 sub panels, all proper grounding and bonding, complete rewire with recepts,switches,lights,fixtures,smoke and co derectors as per 2008 nec (south district) ![]() ![]() Client: Joseph Ciro And Dominic C | Permit type: Electrical permit | Permit status: Active | Completion date: November 6, 2017 | Permit id: 783234 | |||||
SCORE 100 1851 Blair St Philadelphia Pa 19125 Electrical construction for a new single-family dwelling - 200amp electrical service, all proper grounding, smoke and c o detectors and complete wiring throughout - all work will comply with the 2009 irc and the 2008 nec for a single-family dwelling ![]() ![]() Permit type: Electrical permit | Permit status: Completed | Completion date: June 25, 2014 | Permit id: 517357 | |||||
SCORE 100 18 N Hancock St Philadelphia Pa 19122 Temporary 100amp service for construction site - 4-gfci protected outlets to be used from 9 27 16 to 3 27 17 as per nec 2008 east district ![]() ![]() Permit type: Electrical permit | Permit status: Completed | Completion date: February 22, 2017 | Permit id: 724559 | |||||
SCORE 100 2447 S Camac St Philadelphia Pa 191483509 Rewire 2nd floor bathroom, 3 receptacles, 3 switches, 2 lights, 1 fan, wire as per 2008 nec (south dist) ![]() ![]() Client: Blakely Elizabeth | Permit type: Electrical permit | Permit status: Expired | Completion date: April 28, 2011 | Permit id: 338083 | |||||
SCORE 100 8304 Algon Ave Philadelphia Pa 191522224 Install receptacles, 15 switches, 18 recessed light fixtures, 6 light fixtures, smoke & co2 detectors, circuits for a c & hot water. ![]() ![]() Client: Mcaninley Joseph Mcaninley Lisa M | Permit type: Electrical permit | Permit status: Completed | Completion date: July 28, 2010 | Permit id: 271807 | |||||
SCORE 100 1242 S Broad St Philadelphia Pa 191463119 Replace 200amp circuit breaker panel circuit and sub-panel circuit all proper grounding as per 2008 nec (sfd) ![]() ![]() Client: Handmaids Of The Sacred H | Permit type: Electrical permit | Permit status: Completed | Completion date: July 2, 2012 | Permit id: 408752 | |||||
SCORE 100 1026 Catharine St Philadelphia Pa 191472737 Partial rewiring of existing bedroom to include 1 additional ouotlet, 8 recessed lights and three way switches. Complete wiring of new bedroom bath including (8) outlets (8)recessed lights, three-wayswithces. Dedicated gfci circuit for bathroom lighting. As per 2008 nec. ![]() ![]() Client: Shah Chetan D Shah Rupali Patel | Permit type: Electrical permit | Permit status: Active | Completion date: December 15, 2017 | Permit id: 839783 |