Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Change use from warehouse to indooor argriculture, construct tenant improvemnts, and occupy as an agricultureal ![]() ![]() Applicant: West, John | Permit type: Construction | Permit status: Permit issued | Current use: Commercial | Permit id: 6392325 | |||||
SCORE 95 Tenant improvement in existing office warehouse building. ![]() Applicant: Engert, Paul | Permit type: Construction | Permit status: Initial information colle | Current use: Industrial | Permit id: 6466701 | |||||
Alterations to existing building, per plan. ![]() ![]() Applicant: Engert, Paul | Permit type: Construction | Permit status: Permit issued | Current use: Industrial | Permit id: 6476241 | |||||
SCORE 100 Change use from warehouse to light manufacturing and construct substantial alterations to existing commercial building, and occupy per plan. Applicant: Wyman, Jennifer | Permit type: Construction | Permit status: Permit issued | Current use: Commercial | Permit id: 6466701 | |||||
Alterations to existing warehouse and subject to field inspection (stfi) ![]() ![]() Applicant: Wyman, Jennifer | Permit type: Construction | Permit status: Permit issued | Current use: Commercial | Permit id: 6475654 | |||||
Re-roof existing commercial building. Per stfi ![]() ![]() Applicant: Mylan, Jay | Permit type: Construction | Permit status: Permit issued | Current use: Commercial | Permit id: 6476138 | |||||
Demolish a portion of existing building, per plot plan, per stfi ![]() Applicant: Conway, Brett | Permit type: Demolition | Permit status: Permit closed | Current use: Industrial | Permit id: 6471945 | |||||
Change use from warehouse to indooor argriculture, construct tenant improvemnts, and occupy as an agricultureal ![]() ![]() Applicant: West, John | Permit type: Construction | Permit status: Permit closed | Current use: Commercial | Permit id: 6392325 | |||||
Alterations to existing office and warehouse building per plan. Applicant: Engert, Paul | Permit type: Construction | Permit status: Initial information colle | Current use: Commercial | Permit id: 6498813 | |||||
Interior alterations to existing commercial building, subject to field inspection (stfi). ![]() ![]() Applicant: Wyman, Jennifer | Permit type: Construction | Permit status: Permit issued | Expiration date: September 14, 2017 | Current use: Industrial | Permit id: 6522510 | |||||
Alterations to existing office building for tenant improvements to levels 1 and 2, per plan. ![]() ![]() Applicant: Schutz, Todd | Permit type: Construction | Permit status: Permit issued | Expiration date: November 9, 2017 | Current use: Commercial | Permit id: 6498813 | |||||
Alterations to existing building, per plan. ![]() ![]() Applicant: Schutz, Todd | Permit type: Construction | Permit status: Permit closed | Completion date: June 22, 2016 | Expiration date: July 8, 2017 | Current use: Industrial | Permit id: 6476241 | |||||
Exterior only alteration: construct an 8 high cmu wall per seattle city light transformer clearance requirements. Applicant: Wyman, Jennifer | Permit type: Construction | Permit status: Initial information colle | Current use: Industrial | Permit id: 6557257 | |||||
SCORE 100 New 900a service to building, including new service transformer. Permit type: Electrical | Permit status: Application accepted | Current use: Commercial | Permit id: 6557894 | |||||
SCORE 95 Install approximately 3 new cat6 cables into the space from an existing idf in the main building. ![]() ![]() Permit type: Electrical | Permit status: Permit issued | Expiration date: August 22, 2017 | Current use: Commercial | Permit id: 6552684 | |||||
SCORE 95 Job# 508119 (bnb builders project adn ph2) provide and install an access control, video intercom and video surveillance systems to new structure. 87 devices, 11 controllers, 1 server, 2 power supplies, and 1 encoder. ![]() ![]() Permit type: Electrical | Permit status: Permit issued | Expiration date: August 5, 2017 | Current use: Commercial | Permit id: 6550015 | |||||
SCORE 100 Seq #31471 - new 1 amp 208 volt feeder to (3) existing disconnects. ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Completion date: July 1, 2016 | Expiration date: June 29, 2017 | Current use: Commercial | Permit id: 6543488 | |||||
SCORE 91 The installation of hvac controls for 13 zones and 1 rooftop unit. ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Completion date: September 2, 2016 | Expiration date: June 23, 2017 | Current use: Commercial | Permit id: 6542261 | |||||
SCORE 95 Install aes to monitor existing facp ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Completion date: July 13, 2016 | Expiration date: June 8, 2017 | Current use: Commercial | Permit id: 6539387 | |||||
SCORE 100 Add fa devices for elevator recall. Joint venture sequoya & red hawk ![]() ![]() Permit type: Electrical | Permit status: Permit issued | Expiration date: June 8, 2017 | Current use: Commercial | Permit id: 6538283 | |||||
SCORE 100 Add fa devices for warehouse space. Joint venture sequoya & red hawk ![]() ![]() Permit type: Electrical | Permit status: Application accepted | Current use: Commercial | Permit id: 6538285 | |||||
SCORE 95 Install 2 tstats. ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Completion date: June 30, 2016 | Expiration date: May 27, 2017 | Current use: Commercial | Permit id: 6537450 | |||||
SCORE 100 Seq #31103-01 relocate (3) existing fixtures, install (1) switch, install (1) card reader with alarm, (2) new vaportight fixtures. ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Completion date: July 1, 2016 | Expiration date: April 25, 2017 | Current use: Commercial | Permit id: 6531220 | |||||
SCORE 91 [joint venture with sequoyah electric llc. ] add fa devices for ti space. ![]() ![]() Permit type: Electrical | Permit status: Permit issued | Expiration date: April 21, 2017 | Current use: Commercial | Permit id: 6530777 | |||||
SCORE 100 Seq #31103-01 - install (2) receptacles, (3) light fixtures, (1) switch. ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Completion date: July 1, 2016 | Expiration date: March 28, 2017 | Current use: Commercial | Permit id: 6526194 | |||||
SCORE 95 Installing about cat6 cables and an additional rack in the idf room under the mezzanine. ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Completion date: March 7, 2016 | Expiration date: March 7, 2017 | Current use: Commercial | Permit id: 6522514 | |||||
SCORE 100 Seq #313 - install (2) individual sections of 150a busway. ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Completion date: February 26, 2016 | Expiration date: February 24, 2017 | Current use: Commercial | Permit id: 6520835 | |||||
SCORE 100 Seq #31103-01 install conduit and cabling for security devices at bike storage locker. Device terminations by others. ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Completion date: February 12, 2016 | Expiration date: February 4, 2017 | Current use: Commercial | Permit id: 6517673 | |||||
SCORE 95 (job# 506618 bike cage) provide & install the following equipment: 1-camera, 1-card reader, 1-door contact, 1-controler boards, locking hardware, electrical permit & inspection, programming, testing, and commissioning. All cabling will be provided by others. ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Completion date: February 16, 2016 | Expiration date: February 3, 2017 | Current use: Commercial | Permit id: 6517411 | |||||
SCORE 100 Seq #31103-01 add (14) 120v 20a receptacles, (13) switches, (10) light fixtures. ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Completion date: March 7, 2016 | Expiration date: January 27, 2017 | Current use: Commercial | Permit id: 6516224 | |||||
SCORE 100 31103-01 - add (42) 120v 20a receptacles, (4) switches, (4) light fixtures, (2) exit signs, (2) emergency bugeyes. ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Completion date: March 7, 2016 | Expiration date: January 27, 2017 | Current use: Commercial | Permit id: 6516221 | |||||
SCORE 100 Seq #31324 - add (2) 100a 208v dedicated circuits for equipment. ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Completion date: January 29, 2016 | Expiration date: January 7, 2017 | Current use: Commercial | Permit id: 6512868 | |||||
SCORE 100 Seq# 31303. Add (1) 60a 208v 3-ph branch crkt & (9) 120v 20a branch crkts. (2) 60a discos & (2) 30a discos tapped off existing 100a feeder. ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Completion date: January 29, 2016 | Expiration date: December 29, 2016 | Current use: Commercial | Permit id: 6511502 | |||||
SCORE 100 Seq# 31103. Warehouse mezzanine. Add (30) 20a receptacles to existing branch circuits. Relocate (20) 20a receptacles. Add (10) data rough-in locations. ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Completion date: January 29, 2016 | Expiration date: December 29, 2016 | Current use: Commercial | Permit id: 6511501 | |||||
SCORE 98 All conduit work by others. Pull wire and connect all controls ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Completion date: December 10, 2015 | Expiration date: December 6, 2016 | Current use: Commercial | Permit id: 6508217 | |||||
SCORE 100 [temporary power. ] temp generator, no feeders ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Completion date: November 20, 2015 | Expiration date: November 18, 2016 | Current use: Commercial | Permit id: 6505946 | |||||
SCORE 100 Installation of low voltage av into conference rooms and collaboration area. Leve1 & 2 ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Completion date: December 1, 2015 | Expiration date: November 18, 2016 | Current use: Commercial | Permit id: 6505860 | |||||
SCORE 95 Job# 50618 (adn 6th & stacy) provide & install the following equipment: 5-power supplies, 2-access control panels, 16-cameras, 15-card readers, 20-door contacts, 15-controler boards, 13-sounders, 4-wireless buttons, 2-edrs, 2-intercom systems, 2-video servers, electrical inspection, programming, testing, and commissioning. All cabling will be provided by others. Site contact: dan kroll 206-450-1034 ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Completion date: February 11, 2016 | Expiration date: October 4, 2016 | Current use: Commercial | Permit id: 6498218 | |||||
SCORE 95 Install 591 cat6 cables for network fed from two idfs connected via fiber backbone. Existing building is old warehouse, gutted to be used as office space ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Completion date: November 23, 2015 | Expiration date: September 2, 2016 | Current use: Commercial | Permit id: 6493032 | |||||
SCORE 91 Installation of a distech building automation system. ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Completion date: November 20, 2015 | Expiration date: August 26, 2016 | Current use: Commercial | Permit id: 6492145 | |||||
SCORE 100 Tenant improvement of existing warehouse including branch power, lighting, mechanical, and gear. Project name: adn, phase 1b. Permit type: Electrical | Permit status: Permit closed | Completion date: December 3, 2015 | Expiration date: October 6, 2016 | Current use: Commercial | Permit id: 6488728 | |||||
SCORE 100 Seq # 37315. Temp feeders 100-amp & 225-amps. New 50-amp circuit. Altered 20-amp circuits. ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Completion date: June 5, 2015 | Expiration date: June 1, 2016 | Current use: Commercial | Permit id: 6477067 | |||||
SCORE 92 12 thermostats ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Completion date: January 27, 2015 | Expiration date: January 22, 2016 | Current use: Commercial | Permit id: 6455836 | |||||
SCORE 95 Install (2) appliance circuits and 4 receptacles ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Completion date: December 16, 2014 | Expiration date: December 12, 2015 | Current use: Commercial | Permit id: 6450492 | |||||
SCORE 59 Install lighting plug ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Completion date: December 18, 2014 | Expiration date: October 10, 2015 | Current use: Industrial | Permit id: 6440898 | |||||
SCORE 59 Install low voltage security system ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Completion date: January 27, 2015 | Expiration date: October 1, 2015 | Current use: Commercial | Permit id: 6439199 | |||||
SCORE 99 Tenant improvement grow facility Permit type: Electrical | Permit status: Permit closed | Completion date: December 18, 2014 | Expiration date: September 4, 2015 | Current use: Commercial | Permit id: 6433433 | |||||
SCORE 95 Intrusion alarm install ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Completion date: August 13, 2014 | Expiration date: August 9, 2015 | Current use: Commercial | Permit id: 6431106 | |||||
SCORE 95 Install alarm circuit ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Completion date: November 4, 2013 | Expiration date: November 1, 2014 | Current use: Commercial | Permit id: 6390320 | |||||
SCORE 61 Reconnect propane tank ![]() ![]() Permit type: Electrical | Permit status: Permit finaled | Completion date: July 17, 2008 | Expiration date: July 14, 2009 | Current use: Commercial | Permit id: 6187704 | |||||
SCORE 100 Installing t-stat for new heat ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Completion date: January 8, 2009 | Expiration date: July 25, 2008 | Current use: Commercial | Permit id: 6147898 | |||||
SCORE 99 Installing new fixtures with seattle city light retrofit program ![]() ![]() Permit type: Electrical | Permit status: Permit finaled | Completion date: April 11, 2008 | Expiration date: April 4, 2008 | Current use: Commercial | Permit id: 6134514 | |||||
SCORE 95 Install access control system ![]() ![]() Permit type: Electrical | Permit status: Permit finaled | Completion date: November 8, 2007 | Expiration date: May 25, 2007 | Current use: Commercial | Permit id: 6099947 | |||||
SCORE 95 Add to existing security system ![]() ![]() Permit type: Electrical | Permit status: Permit finaled | Completion date: September 14, 2007 | Expiration date: May 15, 2007 | Current use: Commercial | Permit id: 6098483 | |||||
SCORE 100 Tenant improvement: install sub-panel with circuits for new presses, cutters, binding equipment and lighting. Install separate circuit for d1 heidelberg press. ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Completion date: May 25, 2011 | Expiration date: May 18, 2006 | Current use: Commercial | Permit id: 6058089 | |||||
Install (1) new interior exhaust fan with vent cap on roof. Modify existing duct work to accommodate break room expansion. ![]() ![]() Applicant: Camis, Sondra | Permit type: Mechanical | Permit status: Permit issued | Expiration date: December 24, 2017 | Current use: Commercial | Permit id: 6538404 | |||||
SCORE 95 Ionstall new elevator- edd926 ![]() ![]() Applicant: Thyssenkrupp Elevator Corp | Permit type: Conveyance | Permit status: Permit closed | Completion date: October 3, 2016 | Expiration date: December 15, 2017 | Permit id: 6538215 | |||||
SCORE 95 Install (1) freezer condensing unit ![]() ![]() Applicant: Acco Es Dba Bellevue Mech | Permit type: Refrigeration | Permit status: Permit closed | Completion date: July 1, 2016 | Expiration date: November 30, 2017 | Current use: Commercial | Permit id: 6537565 | |||||
Replace one roof vent cap for a. D. N. Bond shop, subject to field inspection, stfi. ![]() ![]() Applicant: Lee, Michael | Permit type: Mechanical | Permit status: Permit closed | Completion date: July 1, 2016 | Expiration date: November 13, 2017 | Current use: Commercial | Permit id: 6534809 | |||||
SCORE 95 Install two (2) chimney vents for new walk-in ovens, (no equipment installed on roof), per plans. Applicant: Camis, Sondra | Permit type: Mechanical | Permit status: Permit closed | Completion date: August 5, 2016 | Expiration date: January 16, 2018 | Current use: Commercial | Permit id: 6529787 | |||||
SCORE 95 Install (2) new ra boot and sidewall grilles and low pressure ductwork. Subject to field inspection. Applicant: Lee, Michael | Permit type: Mechanical | Permit status: Permit closed | Completion date: July 1, 2016 | Expiration date: October 26, 2017 | Current use: Commercial | Permit id: 6531542 | |||||
SCORE 95 Install (1) rooftop ac unit; install 14 vav boxes; install one split system; install one exhaust fan; install 7 electric heaters, per plan Applicant: Toutonghi, Tyler | Permit type: Mechanical | Permit status: Permit closed | Completion date: September 2, 2016 | Expiration date: December 21, 2017 | Current use: Commercial | Permit id: 6524766 | |||||
Mechanical stfi; install (1) diffuser and associated ductwork. ![]() ![]() Applicant: Toutonghi, Tyler | Permit type: Mechanical | Permit status: Permit closed | Completion date: July 1, 2016 | Expiration date: September 21, 2017 | Current use: Commercial | Permit id: 6524971 | |||||
Demolish unused existing ductwork. Add new ductwork to extend into new tenant partition spaces. Add side wall/duct grilles to accommodate new tenant wall/space layout. Work to take place in ceiling area, no penetrations, subject to field inspection, stfi. ![]() ![]() Applicant: Davies, Russ | Permit type: Mechanical | Permit status: Permit closed | Completion date: March 8, 2016 | Expiration date: July 15, 2017 | Current use: Commercial | Permit id: 6514106 | |||||
SCORE 99 Installation of commercial vertical platform lift ![]() ![]() Applicant: Mobility Concepts Inc | Permit type: Conveyance | Permit status: Permit closed | Completion date: December 10, 2015 | Expiration date: February 28, 2017 | Permit id: 6491027 | |||||
SCORE 100 Add sewer connection ![]() ![]() Applicant: Johnson Backhoe/dozing Srv Inc | Permit type: Side sewer | Permit status: Permit closed | Completion date: January 13, 2016 | Expiration date: February 19, 2017 | Current use: Industrial | Permit id: 6490649 | |||||
SCORE 95 Install 22 split systems ![]() ![]() Applicant: Acco Es Dba Bellevue Mech | Permit type: Refrigeration | Permit status: Permit closed | Completion date: December 11, 2015 | Expiration date: January 22, 2017 | Current use: Commercial | Permit id: 6485618 | |||||
SCORE 100 Installation of (5)-3. 5 ton, (5)-3 ton and (2)-2 ton ductless mini split systems ![]() ![]() Applicant: Diamond Construction Srvcs Llc | Permit type: Refrigeration | Permit status: Permit closed | Completion date: January 28, 2015 | Expiration date: July 26, 2016 | Current use: Commercial | Permit id: 6456357 | |||||
SCORE 100 Installation of 12 ductless mini split heat pumps, 1 utility set exhaust fan, 1 - inline supply fan and related duct work for exhaust fan and supply fan. Applicant: Fite, Dale | Permit type: Mechanical | Permit status: Permit closed | Completion date: April 29, 2015 | Expiration date: March 16, 2016 | Current use: Commercial | Permit id: 6433768 | |||||
Mechanical work to installing 4 roof top package units heatpumps with associate ductwork, per plans. ![]() ![]() Applicant: Fite, Dale | Permit type: Mechanical | Permit status: Permit closed | Completion date: May 14, 2014 | Expiration date: May 27, 2015 | Current use: Commercial | Permit id: 6381931 | |||||
Install pressure vessel ![]() Applicant: System Transfer & Storage Co, | Permit type: Boiler / pressure vessel | Permit status: Permit closed | Completion date: March 15, 2012 | Expiration date: September 12, 2013 | Current use: Commercial | Permit id: 6313686 | |||||
Remove unnecessary ductwork. Install ductwork and grilles for the purpose of extended/added tenant improvement rooms/spaces. No new equipment is to be added. Applicant: Davies, Russ | Permit type: Mechanical | Current use: Commercial | Permit id: 6513779 | |||||
SCORE 95 Closed as incomplete - expired permit. Installing new non-illuminated wall sign for sixth@lander permit parking tai foong usa ![]() ![]() Applicant: Signs Of Seattle Inc | Permit type: Sign/billboard/awning | Permit status: Permit closed | Expiration date: May 20, 2010 | Current use: Commercial | Permit id: 6201442 | |||||
SCORE 95 New expansion tank ![]() ![]() Applicant: All Temp Mechanical Inc | Permit type: Boiler / pressure vessel | Permit status: Permit finaled | Completion date: May 20, 2008 | Expiration date: November 13, 2009 | Current use: Commercial | Permit id: 6180742 | |||||
SCORE 95 Closed as incomplete - expired permit. Install non-illum wall sign - tai foong usa inc. ![]() ![]() Applicant: Signs Of Seattle Inc | Permit type: Sign/billboard/awning | Permit status: Permit closed | Expiration date: August 7, 2009 | Current use: Commercial | Permit id: 6168984 | |||||
SCORE 100 Add rooftop coil for 3-ton split system hvac ![]() ![]() Applicant: Co-Op A/c & Heating Llc | Permit type: Refrigeration | Permit status: Permit finaled | Completion date: July 27, 2007 | Expiration date: January 23, 2009 | Current use: Commercial | Permit id: 6147515 | |||||
SCORE 100 Install one carrier 3 ton split system unit on the roof with duct work in existing office space on the first floor, per plan Applicant: Crane, Brad | Permit type: Mechanical | Permit status: Permit finaled | Completion date: September 6, 2007 | Expiration date: January 23, 2009 | Current use: Commercial | Permit id: 6146230 | |||||
SCORE 91 Repair leak in the mudleg ![]() ![]() Applicant: Cole Industrial Incorporated | Permit type: Boiler / pressure vessel | Permit status: Permit finaled | Completion date: October 31, 2003 | Expiration date: April 23, 2005 | Current use: Commercial | Permit id: 6024246 | |||||
SCORE 100 Installing t-stat for new heat ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Completion date: January 8, 2009 | Expiration date: July 25, 2008 | Current use: Commercial | Permit id: 6147898 | |||||
SCORE 99 Closed - parent permit issued day get started to be on site for branch circuits only; plan review under 6433433. Jss extended get started to 10/3/14. ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Expiration date: October 3, 2014 | Current use: Commercial | Permit id: 6433436 | |||||
SCORE 59 Install low voltage security system ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Completion date: January 27, 2015 | Expiration date: October 1, 2015 | Current use: Commercial | Permit id: 6439199 | |||||
SCORE 59 Install lighting plug ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Completion date: December 18, 2014 | Expiration date: October 10, 2015 | Current use: Industrial | Permit id: 6440898 | |||||
SCORE 91 [joint venture with sequoyah electric llc. ] add (6) fa devices to monitor sprinkler tamper/waterflows. ![]() ![]() Permit type: Electrical | Permit status: Permit issued | Expiration date: August 31, 2017 | Current use: Commercial | Permit id: 6554397 | |||||
SCORE 100 Seq #31103-01 remove (4) lights, re-circuits (8) lights, install (2) switches, install (1) amp 208v instahot water heater. Install (26) 20amp duplex receptacles consisting of 8 new circuits, wiring up 3amp 120v exhaust fan. ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Completion date: November 7, 2016 | Expiration date: November 3, 2017 | Current use: Commercial | Permit id: 6565196 | |||||
SCORE 95 Wo# 30754 - (and-roll up door) provide and install (2)-card readers, (1)-camera, (1) door contacts, (1) lnl-1320, and (1) lnl-1100. All device cable provided by others. Provide testing and commissioning. Site contact: dan kroll 206-450-1034 ![]() ![]() Permit type: Electrical | Permit status: Permit issued | Expiration date: January 18, 2018 | Current use: Commercial | Permit id: 6576590 | |||||
Construct alterations to existing industrial building at the ground floor exterior, per plan. ![]() ![]() Applicant: Wyman, Jennifer | Permit type: Construction | Permit status: Permit issued | Expiration date: May 29, 2018 | Current use: Industrial | Permit id: 6557257 | |||||
Install roof fan to exhaust air from compressor room, per plan ![]() ![]() Applicant: Toutonghi, Tyler | Permit type: Mechanical | Permit status: Permit issued | Expiration date: June 27, 2018 | Current use: Commercial | Permit id: 6568381 | |||||
SCORE 95 Replace existing barometric relief hood with new fan-powered relief hood. Per plans. Applicant: Camis, Sondra | Permit type: Mechanical | Permit status: Permit issued | Expiration date: May 15, 2018 | Current use: Commercial | Permit id: 6561569 | |||||
Demolish unused existing ductwork. Add new ductwork to extend into new tenant partition spaces. Add side wall duct grilles to accommodate new tenant wall space layout. Work to take place in ceiling area, no penetrations, subject to field inspection, stfi. ![]() ![]() Applicant: Davies, Russ | Permit type: Mechanical | Permit status: Permit closed | Completion date: March 8, 2016 | Expiration date: July 15, 2017 | Current use: Commercial | Permit id: 6514106 | |||||
SCORE 95 Closed as incomplete - expired permit. Install (2) illum wall signs for "nuleaf office supply" ![]() ![]() Applicant: Western Neon Inc | Permit type: Sign/billboard/awning | Permit status: Permit closed | Expiration date: April 8, 2015 | Current use: Commercial | Permit id: 6385423 | |||||
Remove unnecessary ductwork. Install ductwork and grilles for the purpose of extended added tenant improvement rooms spaces. No new equipment is to be added. Applicant: Davies, Russ | Permit type: Mechanical | Current use: Commercial | Permit id: 6513779 | |||||
SCORE 100 Add rooftop coil for 3-ton split system hvac ![]() ![]() Applicant: Co-Op A/c & Heating Llc | Permit type: Refrigeration | Permit status: Permit finaled | Completion date: July 27, 2007 | Expiration date: January 23, 2009 | Current use: Commercial | Permit id: 6147515 | |||||
SCORE 100 Install one carrier 3 ton split system unit on the roof with duct work in existing office space on the first floor, per plan Applicant: Crane, Brad | Permit type: Mechanical | Permit status: Permit finaled | Completion date: September 6, 2007 | Expiration date: January 23, 2009 | Current use: Commercial | Permit id: 6146230 | |||||
SCORE 95 J# 5094 install (108) white noise emitters (3) controller & associated cabling for complete white noise system floors 1 & floor 2 mark teller (206) 496-7836 ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Completion date: January 3, 2017 | Expiration date: December 13, 2017 | Current use: Commercial | Permit id: 6571319 | |||||
SCORE 95 10 12 2016 - cancelled customer log #16-1540install 13 tstats ![]() ![]() Permit type: Electrical | Permit status: Permit issued | Expiration date: May 27, 2017 | Current use: Commercial | Permit id: 6537458 | |||||
Construct interior alterations to an existing commercial building, per plan. ![]() ![]() Applicant: Wyman, Jennifer | Permit type: Construction | Permit status: Permit closed | Completion date: March 28, 2017 | Expiration date: September 22, 2018 | Current use: Industrial | Permit id: 6577689 | |||||
SCORE 95 Wo# 33889 - (sea-74) provide and install (2)-card readers, (1) lnl-1320, and all device cable. Provide testing and commissioning. Site contact: dan kroll 206-450-1034 ![]() ![]() Permit type: Electrical | Permit status: Permit issued | Expiration date: June 28, 2018 | Current use: Commercial | Permit id: 6605439 | |||||
SCORE 100 Add facp & devices; this is a joint venture between sequoyah electric & red hawk. 12/1/15 jcb; opened permit to add review for new f/a system and added 2 f/a devices per sfr reviewer. ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Completion date: December 3, 2015 | Expiration date: September 15, 2016 | Current use: Commercial | Permit id: 6494780 | |||||
Remove unnecessary ductwork. Install ductwork and grilles for the purpose of extended added tenant improvement rooms spaces. No new equipment is to be added. Applicant: Davies, Russ | Permit type: Mechanical | Current use: Commercial | Permit id: 6513779 | |||||
SCORE 100 Seq #31103-01 refeed existing panel, (1) 100a feeder, (2) 50a branch circuits. 1/7/16 sk revised owner info ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Completion date: January 7, 2016 | Expiration date: December 7, 2016 | Current use: Commercial | Permit id: 6508480 | |||||
SCORE 91 [joint venture with sequoyah electric llc. ] add fa devices for ti space. ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Completion date: December 12, 2016 | Expiration date: April 21, 2017 | Current use: Commercial | Permit id: 6530777 | |||||
SCORE 100 Day get started for branch circuits only, plan review permit under 6527474 (assoc elec permit 6527474)(seq job#31353). 5/19/16 paf renew ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Completion date: June 2, 2016 | Expiration date: June 12, 2016 | Current use: Commercial | Permit id: 6528189 | |||||
SCORE 100 Tenant improvement including new 480v and 120v panelboards, lighting, receptacles, mechanical, and elevator. [related project number: 6498813], 9/6/16,jas-revision added for elevator feeder change, no change in value Permit type: Electrical | Permit status: Permit issued | Completion date: October 24, 2016 | Expiration date: June 2, 2017 | Current use: Commercial | Permit id: 6527474 | |||||
SCORE 95 2 amp service, connect to existing house circuits. 04 12 17 cep; add (2) amp feeders. ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Completion date: May 9, 2017 | Expiration date: March 16, 2018 | Current use: Commercial | Permit id: 6586493 | |||||
SCORE 100 Seq #31103 - (1) 15a and (1) 20a branch circuit for sprinkler compressor and riser room receptacle. 1/7/16 sk revised owner info. ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Completion date: January 29, 2016 | Expiration date: November 19, 2016 | Current use: Commercial | Permit id: 6506125 | |||||
SCORE 95 Job# 510927 - (fm1735 mezzanine & phase ii) provide and install (3) cameras, (4) card readers, (3) sounders, (3) door contacts, (1)-lnl 1320, (3) set of locking hardware, (provided and installed by others) and run all device cable and conduit. Provide testing and commissioning. Site contact: dan kroll 206-450-1034. We will provide and install (1) lenel ctx6 can, (1) additional lnl 1320, (1) additional card reader. 10 11 17 cep; add (2) control units and (1) device ![]() ![]() Permit type: Electrical | Permit status: Permit issued | Expiration date: September 13, 2018 | Current use: Commercial | Permit id: 6618672 | |||||
SCORE 100 Install raceway for fiber cable at 2 locations. Inspection per rm for one trip. 1/7/16 sk rivised owner info ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Completion date: January 7, 2016 | Expiration date: December 2, 2016 | Current use: Commercial | Permit id: 6507736 | |||||
SCORE 95 Install (19) new split system a/c units with gas heat, (1) new split system cooling only, (2) new make up air units with gas heat, (6) new intake hoods, (5) new relief hoods and associated ductwork, grilles and diffusers. Applicant: Camis, Sondra | Permit type: Mechanical | Permit status: Permit closed | Completion date: November 30, 2015 | Expiration date: January 21, 2017 | Current use: Commercial | Permit id: 6474505 | |||||
SCORE 95 Replace fire alarm panel ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Completion date: March 7, 2013 | Expiration date: September 9, 2012 | Current use: Commercial | Permit id: 6294157 | |||||
SCORE 100 Seq #31103-01 new 125 amp 4 volt feeder to new oven, (1) 2 amp fused disconnect, new amp 480v feeder to new 2nd oven, (1) 1 amp fused disconnect, (1) amp feeder to new freezer/split unit, (2) light switches, 16 duplex receptacles, (1) bug eye exit sign, (2) gfci receptacles. ![]() ![]() Permit type: Electrical | Permit status: Permit issued | Completion date: November 10, 2016 | Expiration date: June 29, 2017 | Current use: Commercial | Permit id: 6543522 | |||||
SCORE 95 Replacing existing conrol panel. No new wire to be run. 6 30 11 mvc: change to fire alarm panel. ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Completion date: March 7, 2013 | Expiration date: June 20, 2012 | Current use: Commercial | Permit id: 6286925 | |||||
SCORE 100 Seq #31303 - add receptacles to existing branch circuits - (8) 20a 120v, (3) 20a 208v, (3) 30a 208v, (1) 60a 208v. 1/7/16 sk revised owner info. ![]() ![]() Permit type: Electrical | Permit status: Permit issued | Completion date: November 10, 2016 | Expiration date: December 10, 2016 | Current use: Commercial | Permit id: 6509305 | |||||
SCORE 95 Job# 509722 - (sea-74) provide and install (3)-cameras, (2) card readers (1) lnl-1320, (2) lnl-11 (8) motions sensors, (2) lnl-command keypads, (2) power supplies, (2) axis encoder blades and all device cable. Provide testing and commissioning. Site contact: dan kroll 206-450-1034 ![]() ![]() Permit type: Electrical | Permit status: Permit issued | Expiration date: February 23, 2018 | Current use: Commercial | Permit id: 6582784 | |||||
SCORE 95 2 29 2016 - cancelled customer log #16-299 install 1 tg-7 into existing system ![]() ![]() Permit type: Electrical | Permit status: Permit issued | Expiration date: May 3, 2016 | Current use: Commercial | Permit id: 6472049 | |||||
SCORE 100 Day get started for branch circuits only; plan review under 6484190. [warehouse] extended to 9/15/15. 9-8-15 dwr extended get started permit for more days untill 10-15-15. ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Completion date: September 30, 2015 | Expiration date: October 15, 2015 | Current use: Commercial | Permit id: 6484578 | |||||
SCORE 100 Tenant improvement - new 480v service and associated distribution, receptacles, lighting, and mechanical power. [warehouse] 7/29/15 jcb; scope of the project being divided into 2 parts, value changed to reflect that change. Permit type: Electrical | Permit status: Permit closed | Completion date: December 3, 2015 | Expiration date: September 29, 2016 | Current use: Commercial | Permit id: 6484190 | |||||
SCORE 91 Closed as incomplete[joint venture with sequoyah electric llc. ] add (6) fa devices to monitor sprinkler tamper waterflows. ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Expiration date: August 31, 2017 | Current use: Commercial | Permit id: 6554397 | |||||
SCORE 99 Installation of a new burglar alarm security system. ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Completion date: April 19, 2011 | Expiration date: April 10, 2012 | Current use: Commercial | Permit id: 6279796 | |||||
SCORE 95 Replace burnt existing feeders & service from underground to overhead ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Completion date: April 12, 2011 | Expiration date: April 5, 2012 | Current use: Commercial | Permit id: 6279194 | |||||
SCORE 100 [temporary power. ] seq #31103 - temp generator to provide construction power, prior to permanent power from seattle city light. 1/7/16 sk revised owner info ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Completion date: January 7, 2016 | Expiration date: October 21, 2016 | Current use: Commercial | Permit id: 6501203 | |||||
SCORE 100 Seq #31103 - paint booth electrical - (1) 15a and (1) 20a branch circuit for (6) light fixtures and (1) motor with electric interlock. 1/7/16 sk revised owner info ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Completion date: January 7, 2016 | Expiration date: November 18, 2016 | Current use: Commercial | Permit id: 6505941 | |||||
SCORE 95 Install (1) mini split a/c unit ![]() ![]() Applicant: Acco Es Dba Bellevue Mech | Permit type: Refrigeration | Permit status: Permit closed | Completion date: August 30, 2016 | Expiration date: November 30, 2017 | Current use: Commercial | Permit id: 6537563 | |||||
SCORE 100 Install voice and data communications cabling building address is 624 s lander street ![]() ![]() Permit type: Electrical | Permit status: Permit closed | Completion date: August 20, 2008 | Expiration date: May 7, 2008 | Current use: Commercial | Permit id: 6138639 | |||||
SCORE 95 Install electrical components into modular furniture. 9/7/07 bew address correction from 625 s lander st ![]() ![]() Permit type: Electrical | Permit status: Permit finaled | Completion date: September 11, 2007 | Expiration date: July 24, 2008 | Current use: Commercial | Permit id: 6147713 |