SCORE 89 3219 O St Nw, Washington, Dc 20007 11 borings and 2 auger probes will be advanced using 3. 25 inch hollow stem augers to create a 6 inch annulus. 3 test pits will be advanced at corners of the site. Borings will be advanced to depths as follows: 3 to feet and 8 to 15 feet. Probes will be advanced to a depth of 13 feet. Infiltration testing in accordance with doee standards will be performed within the auger probes. Monitoring wells will be installed in the 3, 30-foot deep borings in accordance with doee requirements. Borings and probes will be abandoned in accordance with doee requirements. ![]() ![]() Client: Washington Dc Dept. Of General Services | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1600122 |
SCORE 89 1 Gallatin St Ne, Washington, Dc 20011 We will perform a total of eleven soil borings and five auger probes at the proposed site. The borings will be drilled utilizing 3. 25-inch hollow stem, continuous flight augers. The borings will be performed utilizing an atv mounted drill rig and will generate an approximately 6-inch annulus. Borings will be advanced to depths as follows: 6 borings to feet and 5 borings to feet. The five auger probes will be advanced to a depth of 8 feet. Backfill of the borings upon completion will be with bentonite slurry that has a mix design of two bentonite powder to one gallon of water. ![]() ![]() Client: United States Of America ? District Of Columbia | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1500358 |
SCORE 89 1315 Clifton St Nw, Washington, Dc 20009 Ecs will employ a geoprobe direct-push drill rig to collect soil samples from 6 boring locations on the property. The resulting bore holes will be 2 inches in diameter. Soil borings will be advanced to 15 feet below grade. Investigation derived waste will be containerized, tested by a lab and shipped off-site for disposal. Borings will be abandoned with a bentonite slurry mix using a 2 to 1 ratio of bentonite powder to water. ![]() ![]() Client: Haile Tekle | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1500223 |
SCORE 89 12 3rd St Ne, Washington, Dc 20002 15 environmental soil borings will be advanced to 35- feet below grade, groundwater, or depth of planned excavation whichever is encountered first using a geoprobe drilling rig. The resulting bore holes will be 2 inches in diameter. Geotechnical soil borings will be advanced with a truck or atv mounted geotech drill rig. 5 will go to ftbg and 5 will go to 1 ftbg. The resulting bore holes will be 6 inches in diameter. Investigation derived waste will be containerized, tested by a lab, and shipped offsite for disposal. Borings will be abandoned with a bentonite slurry mix using a 2 to 1 ratio of bentonite powder to water. ![]() ![]() Client: Central Armature Works | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1500035 |
SCORE 89 901 G St Nw, Washington, Dc 20001 5 soil boaring will be advanced to feet below grade or refusal - whichever is encountered first-using a geoprobe drilling rig. Teh resulting bore holes will be 2 inches diameter. Investigation derived waste will be containerized, tested by a lab, and shipped offsite for disposal. Boarings will be abandoned witha bentonite slurry mix using a 2 to 1 ratio of bentonite powder to water. ![]() ![]() Client: District Of Columbia District Of Columbia | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1400472 |
SCORE 89 5715 Broad Branch Rd Nw, Washington, Dc 20015 We will perform eight soil brings on the proposed site. The soil borings will each be advanced to a depth of feet. Additionally, four soil borings and four infiltration auger probes will be performed on the proposed site and will be advanced to depths of feet and 15 feet, respectively. The borings/auger probes will be located within the bounds of the property. The borings/auger probes will be drilled utilizing 3. 25-inch hollow stem, continuous flight augers. The borings/auger probes will be performed utilizing an atv and/or truck-mounted drill rig and will generate an approximate 6-inch annulus. After geotechnical exploration is completed, the borings/auger probes will be backfilled with bentonite slurry, which has a consistency of two pounds bentonite powder to one gallon water. Borehole/auger probe abandonment will be performed by tremie-grouting via a positive-displacement pump from the bottom of the borehole/auger probe. ![]() ![]() Client: District Of Columbia Public Schools Co Hartman-Cox Architects | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1400362 |
SCORE 89 1875 Columbia Rd Nw, Washington, Dc 20009 We will perform eight soil borings and eight infiltration auger probes on the proposed site. The soil borings and auger probes will be advanced to depths of 15 feet and feet, respectively. The borings/auger probes will be located within the bounds of the property. The borings/auger probes will be drilled utilizing 3. 25-inch hollow stem, continuous flight augers. The borings/auger probes will be performed utilizing an atv and/or truck-mounted drill rig and will generate an approximate 6-inch annulus. After geotechnical exploration is completed, the borings/auger probes will be backfilled with bentonite slurry, which has a consistency of two pounds bentonite powder to one gallon water. Borehole/auger probe abandonment will be performed by tremie-grouting via a positive-displacement pump from the bottom of the borehole/auger probe. ![]() ![]() Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1400363 |
SCORE 89 ![]() ![]() Permit status: Expired | Expiration date: October 13, 2013 | Permit id: Pa10110367-R1 |
SCORE 89 50 Hayes Street Ne Washington Dc Two soil borings with infiltration auger probes approximately six inches in diameter and ten feet in depth with a geotechnical drill rig. ![]() ![]() Client: Aj Architects | Permit type: Excavation; boring test pit (each addl), excavation; boring test pit (single) | Permit status: Cancel/withdrawn | Expiration date: January 2, 2014 |
SCORE 89 ![]() ![]() Permit status: Permit expired | Expiration date: September 14, 2013 | Permit id: Pa10110367 |
Contractor Rank | Contractor Details | Number of Projects | Avg. Project Cost | Years in Business | Photos |
---|---|---|---|---|---|
SCORE 100 | Washington Gas | 14,031 Projects | $12 Avg. Project Cost | 12 Years in Business | ![]() |
SCORE 100 | John Homick | 272 Projects | 7 Years in Business | ![]() | |
SCORE 99 | Long Fence | 547 Projects | 10 Years in Business | ![]() | |
SCORE 96 | Hanlon Design Build Hanlon Design Build | 59 Projects | $36 Avg. Project Cost | 6 Years in Business | ![]() |
SCORE 93 | Dci Dci | 501 Projects | $70 Avg. Project Cost | 5 Years in Business | ![]() |