Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Norfolk above ground piping Date: February 3, 2009 Permit type: Other | Permit status: Closed | Permit id: 09-00279 | |||||
Dave steel co Date: April 22, 2010 Permit status: Closed | Permit id: 08-05042 | |||||
Norfolk southern railyard sup office Date: October 24, 2007 Permit status: Issued | Permit id: 07-05265 | |||||
North fork southern railroad- stand alone plumbing Date: May 15, 2007 Permit type: Plumbing | Permit status: Closed | Permit id: 07-02353 | |||||
Dave steel company Date: February 26, 2009 Permit status: Closed | Permit id: 08-06028 | |||||
Dave steel addition Date: October 21, 2013 Permit status: Closed | Permit id: 08-06029 | |||||
Date: January 24, 2005 Permit status: Closed | Permit id: 03-02038 | |||||
Changing faces on both building signs dave steel Date: April 24, 2014 Permit status: Plan check | Permit id: 14-05812 | |||||
Date: November 27, 2001 Permit status: Closed | Permit id: 01-02765 | |||||
Dave steel oxygen tank Date: October 22, 2010 Permit status: Closed | Permit id: 10-04887 | |||||
Dave steel Date: June 18, 2010 Permit status: Closed | Permit id: 10-02155 | |||||
Dave steel addition Date: April 28, 2010 Permit status: Closed | Permit id: 10-02135 | |||||
SCORE 56 Norfolk southern railyard sup office Client: Norfolk Railyard | Permit type: Com: reroof | Permit status: Closed | Current use: Commercial | Permit id: 07-05265 | Parcel: 32175 | |||||
SCORE 98 Dave steel addition Client: Dave Steel Addition | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 08-06029 | Parcel: 15662 | |||||
SCORE 98 Dave steel co Client: Dave Steel Co | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 08-05042 | Parcel: 15662 | |||||
SCORE 99 Dave steel co Client: Dave Steel Co | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 08-05042 | Parcel: 15662 | |||||
SCORE 100 Dave steel addition Client: Dave Steel Addition | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 08-06029 | Parcel: 15662 | |||||
SCORE 100 Dave steel addition Client: Dave Steel Addition | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 08-06029 | Parcel: 15662 | |||||
SCORE 99 Dave steel addition Client: Dave Steel Addition | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 08-06029 | Parcel: 15662 | |||||
SCORE 91 Dave steel Client: Dave Steel | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 10-02155 | Parcel: 15662 | |||||
SCORE 100 Dave steel addition Client: Dave Steel Addition | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 10-02135 | Parcel: 15662 | |||||
Dave steel Value: $30,000 Client: Dave Steel | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 10-02155 | Parcel: 15662 | |||||
SCORE 91 Dave steel addition Client: Dave Steel Addition | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 10-02135 | Parcel: 15662 | |||||
SCORE 100 Dave steel addition Client: Dave Steel Addition | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 10-02135 | Parcel: 15662 | |||||
SCORE 99 Dave steel addition Client: Dave Steel Addition | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 10-02135 | Parcel: 15662 | |||||
Convert old locker room to office space. Client: Dave Steel Company, Inc | Permit type: Com: plumbing | Permit status: Finaled | Current use: Commercial | Permit id: 16-00741 | Parcel: 15662 | |||||
SCORE 95 Changing faces on both building signsdave steel Date: January 20, 2016 Contractor: Fast Signs Client: Dave Steel Company Sign | Permit type: Stand alone sign | Permit status: Closed | Current use: Sign | Permit id: 14-05812 | Parcel: 15662 | |||||
SCORE 86 Convert old locker room to office space. Date: April 7, 2016 Contractor: Appalachian Electric And Generator Client: Dave Steel Company, Inc | Permit type: Com: electrical | Permit status: Finaled | Current use: Commercial | Permit id: 16-00739 | Parcel: 15662 | |||||
SCORE 66 Convert old locker room to office space. Contractor: Dave Steel Company Inc Client: Dave Steel Company, Inc | Permit type: Com: remodel | Permit status: Cc issued | Current use: Commercial | Permit id: 16-00737 | Parcel: 15662 | |||||
SCORE 100 Dave steel Client: Dave Steel | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 10-02155 | Parcel: 15662 | |||||
SCORE 66 Convert old locker room to office space. Date: April 14, 2016 Contractor: Dave Steel Company Inc Client: Dave Steel Company, Inc | Permit type: Fire prevention | Permit status: Finaled | Current use: Fire | Permit id: 16-00738 | Parcel: 15662 | |||||
SCORE 100 Convert old locker room to office space. Date: March 2, 2016 Contractor: Gentry Heating Inc Client: Dave Steel Company, Inc | Permit type: Com: mechanical | Permit status: Finaled | Current use: Commercial | Permit id: 16-00740 | Parcel: 15662 | |||||
Southern fuel transfer facility Client: Kdh Bp#01-2765 | Permit type: Scv level i | Permit status: Approved | Current use: Site compliance verification | Permit id: 01-10000065pz | |||||
Southern railway oil tank Client: Pmd Bp#03-2038 | Permit type: Planning level i | Permit status: Closed | Current use: Development | Permit id: 03-11000116pz | |||||
Meadow rd / dave steel addition Client: Bp# 08-6029, Clh | Permit type: Scv level i | Permit status: Under review | Current use: Site compliance verification | Permit id: 08-10000117pz | |||||
Modification of existing fuel transfer facility; p&z#01-1065; recd construction plans;cah; additional information submitted for floodplain review/as requested; planning comments: level one project approved for norfolk southern fuel transfer facility modifications, as planned, kdh; 08/16/2001 02:28 pm nberry 07/24/2001 10:52 am nberry documents missing on flood information. Everything needs to be reference from the mean sea level. Talked with david schaad on 7/24/2001 at 11: am and told him i would mail the information for him to put on the drawing. He will submit back to permit office when corrected. Not approved njb 7/24/01. Approved 2nd submittal. Njb no elevation certificates are required for truck pads.; see building comments. Fuel unloading pad and canopy.; call joe chennault for building inspection at redacted phone number; call tom eggers for fire inspection at redacted phone number minimum 2a10bc fire extinguisher; check life safety items at final inspection; emergency lighting Permit type: Com: addition | Permit status: Closed | Permit id: 01-02765 | Parcel: 32175 | |||||
April 22, 20 1:13:45 pm ssalyer. Pouring new slab to set new equipment on (down draft worktable)and running electrical at dave steel in exisiting building;all work to be interior; progress energy has already set a pole for this work will have seperate meter;sls ref 10-2135 for phase 1 addition permit;sls; may 4, 20 12:05:04 pm ssalyer. Rec amendment; adding mechanical permit for exhaust duct to be installed by owner;need to verify with plan review or inspector if this work needs to be done by a license contractor or if can be done by the owner under gc permit;sls; may 5, 20 11:49:01 am heatherr. Per june eames spoke with alec it is ok to issue mechanical to owner; har; may 20, 20 3:37:32 pm ssalyer. Rec tu applications;sls; june 18, 20 8:13:53 am ssalyer. Pouring new slab to set new equipment on (down draft worktable)and running electrical at dave steel in exisiting building;sls; mechanical permit needed for ductwork and exhaust fan/dust collector installation. Lje; building code ins Permit type: Permits - historical | Permit status: Closed | Permit id: 10-02155 | Parcel: 15662 | |||||
SCORE 86 Com: electrical Contractor: Appalachian Electric And Generator Permit status: Finaled | Permit id: 16-00739 | Parcel: 15662 | |||||
SCORE 100 Com: mechanical Contractor: Gentry Heating Inc Permit status: Finaled | Permit id: 16-00740 | Parcel: 15662 | |||||
Com: plumbing Permit status: Finaled | Permit id: 16-00741 | Parcel: 15662 | |||||
August 27, 2008 3:47:43 pm alisam. Dave steel co - nonbearing walls for additional offices, electrical with cat5 wiring;aml; april 22, 20 1:04:49 pm ssalyer. Dave steel co - nonbearing walls for additional offices, electrical with cat5 wiring;sls; fire marshal? S office plan review comments read attached fire prevention comment sheet the approved plans with the attached plan review comments are required to be on the job site at all times. Call for all fire inspections at 828-redacted phone number between the hours of 8: and 9: for a same day inspection. All calls received past 9: am will be scheduled for the next business day. Fire prevention plan review questions may also be directed to this phone number.: the contractor and any affected subcontractor(s) are expected to read and comply with the fire code, all the plan review comments, and are subject to any needed correction orders per ncgs 160a-417 thru 425. Your permit must be posted at the job site at all times or a 100. Stop orde Permit type: Permits - historical | Permit status: Closed | Permit id: 08-05042 | Parcel: 15662 | |||||
October 21, 2008 3:46:56 pm scarver. New addition shop building for dave steel;scc; december 5, 2008 8:52:29 am ssalyer. Rec revised drawings per gc;they will be doing a phased project the new submittal will be for the building addition only phase 2, the interior will be submitted at later date;the costs on the revised submittal is for the building only will give cost for interior when submits that application;routed out revised copies to zoning;ref 08-6028 for demo permit;sls; december 29, 2008 1:14:38 pm scarver. Amendment rec. P,m,e revisions;scc; june 5, 2009 10:15:22 am ssalyer. Rec amendment for adding gas piping for the hvac equipment;sls june 5, 2009 3:55:54 pm ssalyer. Rec tco application;sls; april 14, 20 10:41:52 am scarver. Swo issued for illegal occupation of phase i on expired tcu, needs to obtaintco renewal and valid general contractor, see susannah;scc; april 21, 20 4:06:44 pm scarver. Reference new permit 10-2135;scc; june 10, 2009 10:55:58 am ssalyer. Tco open for bus Permit type: Permits - historical | Permit status: Closed | Permit id: 08-06029 | Parcel: 15662 | |||||
October 21, 2008 3:46:56 pm scarver. New addition shop building for dave steel;scc; april 21, 20 4:03:37 pm scarver. New general contractor for dave steel addition, reference previous permit 08-6029, the new gc will be omitting phase 2 renovation and will apply at future date;scc; april 28, 20 1:14:36 pm ssalyer. New addition shop building for dave steel;sls; october 21, 2008 3:53:05 pm scarver. Will need to submit;scc; received plans for review. Assigned to charleen hall; received application and site plans. October 27, 2008 10:30:22 am sdecker.; gave application and site plans to chuck watson for review. October 27, 2008 10:52:49 am sdecker.; waiting for revised drawing set w/phases and engineers seal. Lje; submitting new plans; approval of the grading permit is pending until the following have been accomplished: 1. Contractor picks up the approved plan from the development services center. 2. Approved plan is posted at the construction site. 3. Preliminary grading and erosion contro Permit type: Permits - historical | Permit status: Closed | Permit id: 10-02135 | Parcel: 15662 | |||||
SCORE 66 Fire prevention Contractor: Dave Steel Company Inc Permit status: Finaled | Permit id: 16-00738 | Parcel: 15662 | |||||
Southern railway - remove existing 10,0 gallon oil storage tank and install new 8,0 gallon ast with 5 hp pump, controls, and 3 kw tank heater.; p&z#03-110116; recd amendment to building safety. Pmd; wnc air pollution approved by mike matthews. Lcs; contacted mr. Wehrmeister at 540-redacted phone number and left message to contact me regarding flood issues on this project. Natalie berry 1-828-redacted phone number; need 3 copies of engineered plans for building, piping, electrical. Called and left answering machine message for frank lemanski. No answer at c. J. Wehrmeisters number.; approved as submitted. Property is within the flood fringe but the tanks are located outside. Natalie berry redacted phone number; planning level one expedite approved. Pmd; for building inspections call harry taylor at redacted phone number. All subcontractors need to complete trade application for project. Subcontractors need to either visit the permit office or fax copy of application to (828)redacte Permit type: Com: remodel | Permit status: Closed | Permit id: 03-02038 | Parcel: 32175 | |||||
Dave steel Date: June 18, 2010 Value: $30,000 Client: Dave Steel | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 10-02155 | Parcel: 15662 | |||||
Convert old locker room to office space. Date: April 7, 2016 Client: Dave Steel Company, Inc | Permit type: Com: plumbing | Permit status: Finaled | Current use: Commercial | Permit id: 16-00741 | Parcel: 15662 | |||||
Southern fuel transfer facility Date: July 6, 2001 Client: Kdh Bp#01-2765 | Permit type: Scv level i | Permit status: Approved | Current use: Site compliance verification | Permit id: 01-10000065pz | |||||
Southern railway oil tank Date: September 8, 2014 Client: Pmd Bp#03-2038 | Permit type: Planning level i | Permit status: Closed | Current use: Development | Permit id: 03-11000116pz | |||||
Meadow rd / dave steel addition Date: October 24, 2008 Client: Bp# 08-6029, Clh | Permit type: Scv level i | Permit status: Under review | Current use: Site compliance verification | Permit id: 08-10000117pz | |||||
Norfolk above ground piping Date: February 3, 2009 Value: $26,000 Permit type: Commercial | Permit status: Closed | Permit id: 09-00279 | |||||
Dave steel co Date: April 22, 2010 Value: $5,000 Permit type: Historical | Permit status: Closed | Permit id: 08-05042 | |||||
Norfolk southern railyard sup office Date: October 24, 2007 Value: $45,624 Permit type: Commercial | Permit status: Issued | Permit id: 07-05265 | |||||
North fork southern railroad- stand alone plumbing Date: May 15, 2007 Value: $7,000 Permit type: Commercial | Permit status: Closed | Permit id: 07-02353 | |||||
Dave steel company Date: February 26, 2009 Value: $5,000 Permit type: Commercial | Permit status: Closed | Permit id: 08-06028 | |||||
Dave steel addition Date: October 21, 2013 Value: $360,000 Permit type: Historical | Permit status: Closed | Permit id: 08-06029 | |||||
Commercial Date: January 24, 2005 Value: $57,045 Permit status: Closed | Permit id: 03-02038 | |||||
Changing faces on both building signsdave steel Date: April 24, 2014 Permit type: Sign | Permit status: Plan check | Permit id: 14-05812 | |||||
Commercial Date: November 27, 2001 Value: $111,270 Permit status: Closed | Permit id: 01-02765 | |||||
Dave steel oxygen tank Date: October 22, 2010 Value: $7,500 Permit type: Historical | Permit status: Closed | Permit id: 10-04887 | |||||
Dave steel addition Date: April 28, 2010 Value: $360,000 Permit type: Historical | Permit status: Closed | Permit id: 10-02135 | |||||
Modification of existing fuel transfer facility; p&z#01-1065; recd construction plans;cah; additional information submitted for floodplain review as requested; planning comments: level one project approved for norfolk southern fuel transfer facility modifications, as planned, kdh; 08 16 2001 02:28 pm nberry 07 24 2001 10:52 am nberry documents missing on flood information. Everything needs to be reference from the mean sea level. Talked with david schaad on 7 24 2001 at 11: am and told him i would mail the information for him to put on the drawing. He will submit back to permit office when corrected. Not approved njb 7 24 01. Approved 2nd submittal. Njb no elevation certificates are required for truck pads.; see building comments. Fuel unloading pad and canopy.; call joe chennault for building inspection at redacted phone number; call tom eggers for fire inspection at redacted phone number minimum 2a10bc fire extinguisher; check life safety items at final inspection; emergency lighting Date: November 27, 2001 Permit type: Com: addition | Permit status: Closed | Permit id: 01-02765 | Parcel: 32175 | |||||
October 21, 2008 3:46:56 pm scarver. New addition shop building for dave steel;scc; april 21, 20 4:03:37 pm scarver. New general contractor for dave steel addition, reference previous permit 08-6029, the new gc will be omitting phase 2 renovation and will apply at future date;scc; april 28, 20 1:14:36 pm ssalyer. New addition shop building for dave steel;sls; october 21, 2008 3:53:05 pm scarver. Will need to submit;scc; received plans for review. Assigned to charleen hall; received application and site plans. October 27, 2008 10:30:22 am sdecker.; gave application and site plans to chuck watson for review. October 27, 2008 10:52:49 am sdecker.; waiting for revised drawing set w phases and engineers seal. Lje; submitting new plans; approval of the grading permit is pending until the following have been accomplished: 1. Contractor picks up the approved plan from the development services center. 2. Approved plan is posted at the construction site. 3. Preliminary grading and erosion contro Date: April 28, 2010 Permit type: Permits - historical | Permit status: Closed | Permit id: 10-02135 | Parcel: 15662 | |||||
Meadow rd dave steel addition Date: October 24, 2008 Client: Bp# 08-6029, Clh | Permit type: Scv level i | Permit status: Under review | Current use: Site compliance verification | Permit id: 08-10000117pz | |||||
SCORE 96 Convert old locker room to office space. Date: April 7, 2016 Contractor: A1 Plumbing Services Client: Dave Steel Company, Inc | Permit type: Com: plumbing | Permit status: Finaled | Current use: Commercial | Permit id: 16-00741 | Parcel: 15662 | |||||
SCORE 86 Comment date: fri jul 06 00:00: edt 2001 - modification of existing fuel transfer facility; p&z#01-1065; comment date: tue jul 00:00: edt 2001 - recd construction plans;cah; comment date: thu aug 09 0 Client: Norfolk Southern | Permit type: Com: addition | Permit status: Closed | Current use: Commercial | Permit id: 01-02765 | Parcel: 32175 | |||||
SCORE 99 Comment date: fri jul 06 00:00: edt 2001 - modification of existing fuel transfer facility; p&z#01-1065; comment date: tue jul 00:00: edt 2001 - recd construction plans;cah; comment date: thu aug 09 0 Client: Norfolk Southern | Permit type: Com: addition | Permit status: Closed | Current use: Commercial | Permit id: 01-02765 | Parcel: 32175 | |||||
SCORE 59 Comment date: fri may 16 00:00: edt 2003 - southern railway - remove existing 10,0 gallon oil storage tank and install new 8,0 gallon ast with 5 hp pump, controls, and 3 kw tank heater.; comment date: Client: Southern Railway | Permit type: Com: remodel | Permit status: Closed | Current use: Commercial | Permit id: 03-02038 | Parcel: 32175 | |||||
SCORE 98 Comment date: fri may 16 00:00: edt 2003 - southern railway - remove existing 10,0 gallon oil storage tank and install new 8,0 gallon ast with 5 hp pump, controls, and 3 kw tank heater.; comment date: Client: Southern Railway | Permit type: Com: remodel | Permit status: Closed | Current use: Commercial | Permit id: 03-02038 | Parcel: 32175 | |||||
April 22, 20 1:13:45 pm ssalyer. Pouring new slab to set new equipment on (down draft worktable)and running electrical at dave steel in exisiting building;all work to be interior; progress energy has already set a pole for this work will have seperate meter;sls ref 10-2135 for phase 1 addition permit;sls; may 4, 20 12:05:04 pm ssalyer. Rec amendment; adding mechanical permit for exhaust duct to be installed by owner;need to verify with plan review or inspector if this work needs to be done by a license contractor or if can be done by the owner under gc permit;sls; may 5, 20 11:49:01 am heatherr. Per june eames spoke with alec it is ok to issue mechanical to owner; har; may 20, 20 3:37:32 pm ssalyer. Rec tu applications;sls; june 18, 20 8:13:53 am ssalyer. Pouring new slab to set new equipment on (down draft worktable)and running electrical at dave steel in exisiting building;sls; mechanical permit needed for ductwork and exhaust fan dust collector installation. Lje; building code ins Date: June 18, 2010 Permit type: Permits - historical | Permit status: Closed | Permit id: 10-02155 | Parcel: 15662 | |||||
SCORE 66 August 27, 20 10:08:19 am ssalyer. Installation of 15 gallon bulk oxygen tank on the exterior of the building for dave steel company;sls; october 22, 20 8:23: am ssalyer. Installation of 15 gallon bulk oxygen tank on the exterior of the building for dave steel company;sls; awaiting cut sheet on tank and msds data on type of oxygen. Lje; zoning approval for the addition of a 15 gallon bulk oxygen at the exterior of the building. August 31, 20 10:21:31 am ashuford.; building code inspection requests must be received before 7: a. M.: phone: redacted phone number. Internet: go to www. Ashevillenc. Gov; select online services; select permit tracking help; select development & building permit tracking tool and enter permit # the building code inspectors assigned to this project can be reached on their cell: building - anne graham redacted phone number electrical - jay eichhorn redacted phone number plumbing / mechanical / gas piping - dan stewart redacted phone number building safety r Client: Dave Steel Oxygen Tank | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 10-04887 | Parcel: 15662 | |||||
SCORE 86 Com: electrical Date: April 7, 2016 Contractor: Appalachian Electric And Generator Permit status: Finaled | Permit id: 16-00739 | Parcel: 15662 | |||||
SCORE 100 Com: mechanical Date: March 2, 2016 Contractor: Gentry Heating Inc Permit status: Finaled | Permit id: 16-00740 | Parcel: 15662 | |||||
SCORE 96 Com: plumbing Date: April 7, 2016 Contractor: A1 Plumbing Services Permit status: Finaled | Permit id: 16-00741 | Parcel: 15662 | |||||
August 27, 2008 3:47:43 pm alisam. Dave steel co - nonbearing walls for additional offices, electrical with cat5 wiring;aml; april 22, 20 1:04:49 pm ssalyer. Dave steel co - nonbearing walls for additional offices, electrical with cat5 wiring;sls; fire marshal? S office plan review comments read attached fire prevention comment sheet the approved plans with the attached plan review comments are required to be on the job site at all times. Call for all fire inspections at 828-redacted phone number between the hours of 8: and 9: for a same day inspection. All calls received past 9: am will be scheduled for the next business day. Fire prevention plan review questions may also be directed to this phone number.: the contractor and any affected subcontractor(s) are expected to read and comply with the fire code, all the plan review comments, and are subject to any needed correction orders per ncgs 160a-417 thru 425. Your permit must be posted at the job site at all times or a 100. Stop orde Date: April 22, 2010 Permit type: Permits - historical | Permit status: Closed | Permit id: 08-05042 | Parcel: 15662 | |||||
SCORE 98 October 21, 2008 3:40:26 pm scarver. Demolishing exisitng structure and removing pavement to pre for new addtion;scc; received application and site plans. October 23, 2008 11:35:42 am sdecker.; gave application and site plans to chuck watson for review. October 23, 2008 11:36:14 am sdecker.; building safety comments see the review comments sheet for additional information and requirements. Building inspections contact anne graham redacted phone number all subcontractors need to complete trade application for project. Subcontractors need to either visit the permit office or fax copy of application to (828)redacted phone number for activation of electrical, plumbing or mechanical permits.; engineering inspections requests must be made at least 24 hours in advance of inspections. The grading/erosion and stormwater inspector assigned to this project is woody ledford who can be reached at redacted phone number. Approval of the grading permit is pending Client: Dave Steel Shed | Permit type: Com: demo | Permit status: Closed | Current use: Commercial | Permit id: 08-06028 | Parcel: 15662 | |||||
October 21, 2008 3:46:56 pm scarver. New addition shop building for dave steel;scc; december 5, 2008 8:52:29 am ssalyer. Rec revised drawings per gc;they will be doing a phased project the new submittal will be for the building addition only phase 2, the interior will be submitted at later date;the costs on the revised submittal is for the building only will give cost for interior when submits that application;routed out revised copies to zoning;ref 08-6028 for demo permit;sls; december 29, 2008 1:14:38 pm scarver. Amendment rec. P,m,e revisions;scc; june 5, 2009 10:15:22 am ssalyer. Rec amendment for adding gas piping for the hvac equipment;sls june 5, 2009 3:55:54 pm ssalyer. Rec tco application;sls; april 14, 20 10:41:52 am scarver. Swo issued for illegal occupation of phase i on expired tcu, needs to obtaintco renewal and valid general contractor, see susannah;scc; april 21, 20 4:06:44 pm scarver. Reference new permit 10-2135;scc; june 10, 2009 10:55:58 am ssalyer. Tco open for bus Date: October 21, 2013 Permit type: Permits - historical | Permit status: Closed | Permit id: 08-06029 | Parcel: 15662 | |||||
SCORE 56 January 14, 2009 1:24:24 pm scarver. Commercial replacing underground piping with above ground piping for norfolk southern;scc; january 29, 2009 12:34:34 pm scarver. Rec. Building applicaiton and plans;scc; january 14, 2009 1:29:51 pm scarver. Holding for documents;scc; january 14, 2009 1:30:09 pm scarver. Holding for documents;scc; january 14, 2009 1:30:46 pm scarver. Will submitt information as needed;scc; received application and site plans. January 16, 2009 3:40:02 pm sdecker.; gave application and site plans to john gavin for review. January 16, 2009 3:44:44 pm sdecker.; received application and site plans. January 16, 2009 3:46:05 pm sdecker.; gave application and site plans to john gavin for review. January 16, 2009 3:46:37 pm sdecker.; received application and site plan. January 16, 2009 3:47:36 pm sdecker.; gave application and site plans to john gavin for review. January 16, 2009 3:48:35 pm sdecker.; project does not meet threshold for level i site plan review. Project is loc Client: Norfolk Above Ground Pipi | Permit type: Com: other new | Permit status: Closed | Current use: Commercial | Permit id: 09-00279 | Parcel: 32175 | |||||
SCORE 66 Fire prevention Date: April 14, 2016 Contractor: Dave Steel Company Inc Permit status: Finaled | Permit id: 16-00738 | Parcel: 15662 | |||||
Southern railway - remove existing 10,0 gallon oil storage tank and install new 8,0 gallon ast with 5 hp pump, controls, and 3 kw tank heater.; p&z#03-110116; recd amendment to building safety. Pmd; wnc air pollution approved by mike matthews. Lcs; contacted mr. Wehrmeister at 540-redacted phone number and left message to contact me regarding flood issues on this project. Natalie berry 1-828-redacted phone number; need 3 copies of engineered plans for building, piping, electrical. Called and left answering machine message for frank lemanski. No answer at c. J. Wehrmeisters number.; approved as submitted. Property is within the flood fringe but the tanks are located outside. Natalie berry redacted phone number; planning level one expedite approved. Pmd; for building inspections call harry taylor at redacted phone number. All subcontractors need to complete trade application for project. Subcontractors need to either visit the permit office or fax copy of application to (828)redacte Date: January 24, 2005 Permit type: Com: remodel | Permit status: Closed | Permit id: 03-02038 | Parcel: 32175 | |||||
SCORE 100 May 15, 2007 1:49:26 pm dshook northfork southern railroad, water line replacement Client: North Fork Southern | Permit type: Com: plumbing | Permit status: Closed | Current use: Commercial | Permit id: 07-02353 | Parcel: 32175 | |||||
SCORE 100 August 26, 2009 2:04:41 pm heatherr. Installation of new panel (re: 8-6029 bu permit) via fax. Call larry davis @ redacted phone number for inspection. Client: Dave Steel Company Inc. | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 09-04318 | Parcel: 1328078 | |||||
Habitat reroof Date: August 26, 2005 Permit status: Issued | Permit id: 05-04110 | |||||
Date: April 28, 2003 Permit status: Closed | Permit id: 03-01230 | |||||
Date: January 8, 2002 Permit status: Closed | Permit id: 01-05484 | |||||
Date: November 16, 2001 Permit status: Issued | Permit id: 01-04996 | |||||
Hfh remodel office Date: April 4, 2007 Permit status: Closed | Permit id: 07-00796 | |||||
SCORE 99 Hfh remodel office Client: Hfh Remodel Office | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 07-00796 | Parcel: 439398 | |||||
SCORE 95 Hfh remodel office Client: Hfh Remodel Office | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 07-00796 | Parcel: 439398 | |||||
SCORE 99 Habitat reroof Client: Habitat Reroof | Permit type: Com: reroof | Permit status: Expired | Current use: Commercial | Permit id: 05-04110 | Parcel: 439398 | |||||
SCORE 100 Hfh remodel office Client: Hfh Remodel Office | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 07-00796 | Parcel: 439398 | |||||
Habitat office, warehouse & store Client: Kdh Bp#01-5342 | Permit type: Scv level i | Permit status: Approved | Current use: Site compliance verification | Permit id: 01-10000127pz | |||||
Demolition of non bearing walls & double flooring, bldg is vacant; also setting temp pole as well as the demo work per jeff cox to sb.; 10/29/2001 02:43 pm nberry approved for demoliton of non load bearing wall only. No remodeling approved at this time. Njb 10/29/2001.; call jim reato at redacted phone number to schedule inspection. To activate subcontractors permits call redacted phone number. No new construction work is allowed under this permit; wnc air pollution approved by mike matthews recd fax Permit type: Com: demo | Permit status: Closed | Permit id: 01-04562 | Parcel: 439398 | |||||
February 16, 2007 12:08:35 pm scarver commercial interior remodel for habitat (4) administrative offices;scc; april 4, 2007 8:48:48 am sbrank habitat for humanity, remodel administrative offices.; building safety review comments the approved plans with the attached review comments are required to be at the job site for use by the field inspector(s) at all times. The building permit is required to be posted at the jobsite at all times. Failure to post approved permits & plans at site is a fine, fine must be paid before next inspection is requested. Building inspections contact jim reato redacted phone number (south/west) electrical inspections contact - kelly sams redacted phone number (south) electrical inspections contact - larry davis redacted phone number (west) plumbing inspections contact - dan stewart redacted phone number (south) plumbing inspections contact - tim jones redacted phone number (west) mechanical inspections contact - alec arthur redacted phone numb Permit type: Permits - historical | Permit status: Closed | Permit id: 07-00796 | Parcel: 439398 | |||||
Habitat office, warehouse & store Date: December 13, 2001 Client: Kdh Bp#01-5342 | Permit type: Scv level i | Permit status: Approved | Current use: Site compliance verification | Permit id: 01-10000127pz | |||||
Habitat reroof Date: August 26, 2005 Value: $60,033 Permit type: Commercial | Permit status: Issued | Permit id: 05-04110 | |||||
Commercial Date: January 8, 2002 Value: $50,000 Permit status: Closed | Permit id: 01-05484 | |||||
Commercial Date: November 16, 2001 Value: $79,977 Permit status: Issued | Permit id: 01-04996 | |||||
Commercial Date: November 9, 2001 Value: $2,000 Permit status: Closed | Permit id: 01-04562 | |||||
Hfh remodel office Date: April 4, 2007 Value: $8,000 Permit type: Historical | Permit status: Closed | Permit id: 07-00796 | |||||
Demolition of non bearing walls & double flooring, bldg is vacant; also setting temp pole as well as the demo work per jeff cox to sb.; 10 29 2001 02:43 pm nberry approved for demoliton of non load bearing wall only. No remodeling approved at this time. Njb 10 29 2001.; call jim reato at redacted phone number to schedule inspection. To activate subcontractors permits call redacted phone number. No new construction work is allowed under this permit; wnc air pollution approved by mike matthews recd fax Date: November 9, 2001 Permit type: Com: demo | Permit status: Closed | Permit id: 01-04562 | Parcel: 439398 | |||||
SCORE 95 Comment date: mon oct 22 00:00: edt 2001 - demolition of non bearing walls & double flooring, bldg is vacant; comment date: fri nov 09 00:00: est 2001 - also setting temp pole as well as the demo work Client: Habitat For Humanity | Permit type: Com: demo | Permit status: Closed | Current use: Commercial | Permit id: 01-04562 | Parcel: 439398 | |||||
SCORE 98 Comment date: mon oct 22 00:00: edt 2001 - demolition of non bearing walls & double flooring, bldg is vacant; comment date: fri nov 09 00:00: est 2001 - also setting temp pole as well as the demo work Client: Habitat For Humanity | Permit type: Com: demo | Permit status: Closed | Current use: Commercial | Permit id: 01-04562 | Parcel: 439398 | |||||
SCORE 99 --- permit for sign package for new habitat for humanity development... --- 1 f-s sign @ sq ft --- 1 wall sign (painted on bldg) -- 181. 85 sq feet... (56. 85 square feet of this sign is square footage transferred from f-s balance not utilized) ---; approved as submitted. Flood fringe. Njb 4/3/2003; ----- work outlined in this permit must commence within six (6) months. No sign or sign structure shall be located within any public right of way. If this sign or sign structure is found to be in violation of the requirements of this permit at any time in the future, you shall be subject to enforcement action as outlined in section 7-18-3 of the unified development ordinance. -----; building safety comments see review comments sheet. Call jim reato at redacted phone number to schedule inspection. All subcontractors need to complete trade application for project. Subcontractors need to either visit the permit office or fax copy of application to (828)redacted Date: April 28, 2003 Contractor: Lettering By Larry Colemon Client: Habitat For Humanity | Permit type: Stand alone sign | Permit status: Closed | Current use: Sign | Permit id: 03-01230 | Parcel: 439398 | |||||
SCORE 99 Comment date: fri nov 16 00:00: est 2001 - remove 4 lbs/square gravel ballast install insulation and pvc membrane zoning note: no occupancy of this building is allowed until a new zoning permit is app Client: Habitat For Humanity | Permit type: Com: reroof | Permit status: Expired | Current use: Commercial | Permit id: 01-04996 | Parcel: 439398 | |||||
SCORE 99 Habitat for humanity. Replace floor system. (see also 01 5342 for related zoning permit. Zoning permit 01-5342 must be issued and valid for this permit to be valid.); flood permit approved as submitted for floor repairs of main and intermediate floors. Basement floor is existing and not under this permit for replacement. Njb 12/31/2001. End of flood permits; building safety review comments the approved plans with the attached review comments are required to be at the job site for use by the field inspector(s) at all times. The building permit is required to be posted at the jobsite at all times. ; call harry taylor for building inspection at redacted phone number building shall not be occupied under this permit. Structural work only.; >>>>fire prevention comments<<<< demo and structural repairs. Not for occupancy. Nfpa 241 safety procedures are to be followed. Sprinkler system shall remain in s Client: Aahh-Floor Replacement | Permit type: Com: remodel | Permit status: Closed | Current use: Commercial | Permit id: 01-05484 | Parcel: 439398 | |||||
SCORE 95 P&z#01-10127; asheville area habitat office, warehouse & store. Today planning staff determined that zoning review would be a level 1 project. Pmd; amended site plans received 1/16/02; recd revised site plans. Pmd; recd revised site plans. Pmd; recd email from jeff burns that applicant has paid fee in lieu of sidewalk construction. Pmd; partial permit approved for construction of floor only, 1/08/02, kdh.; flood permit comments finished floor elevation certificate on file. Basement of warehouse is where the bfe is located the following apply: 1. On site waste disposal system shall be located or constructed to avoid impairment of them or contamination from them from flooding. 2. All new and replacement water supply systems, either private or public, shall be designed and installed to minimize, to the greatest extent practicable, infiltration of floodwaters into the system. 3. All new and replacement sanitary sewerage systems, either private or publi Client: Habitat Office, Warehouse | Permit type: Planning level i | Permit status: Issued | Current use: Development | Permit id: 01-05342 | Parcel: 439398 | |||||
February 16, 2007 12:08:35 pm scarver commercial interior remodel for habitat (4) administrative offices;scc; april 4, 2007 8:48:48 am sbrank habitat for humanity, remodel administrative offices.; building safety review comments the approved plans with the attached review comments are required to be at the job site for use by the field inspector(s) at all times. The building permit is required to be posted at the jobsite at all times. Failure to post approved permits & plans at site is a fine, fine must be paid before next inspection is requested. Building inspections contact jim reato redacted phone number (south west) electrical inspections contact - kelly sams redacted phone number (south) electrical inspections contact - larry davis redacted phone number (west) plumbing inspections contact - dan stewart redacted phone number (south) plumbing inspections contact - tim jones redacted phone number (west) mechanical inspections contact - alec arthur redacted phone numb Date: April 4, 2007 Permit type: Permits - historical | Permit status: Closed | Permit id: 07-00796 | Parcel: 439398 |