Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
SCORE 64 Install aluminum soffit and job site fabricated facia per industry standard with required venting. Remove existing gutter and install new 5 inch k-style aluminum gutter with 3 x 4 downspouts and extensions. Permit type: Residential soffits and gutters | Permit status: Issued | Permit id: Bld-15-03317 | |||||
SCORE 100 Call for any questions scott sherman 402-677-1493 Date: April 7, 2015 Contractor: Scott Sherman Permit type: Residential plumbing | Permit status: Issued | Permit id: Plb-15-02131 | |||||
Main level 842, finished basement 842 Date: September 18, 2015 Value: $60,624 Permit type: Plans required - residential additions | Permit status: Issued | Permit id: Bld-15-07478 | |||||
SCORE 100 Complete remodel and new service Date: May 29, 2015 Contractor: Todd Chase Permit type: Electrical residential existing | Permit status: Issued | Permit id: Elc-15-04215 | |||||
SCORE 64 Remove existing windows. Install tyvek window flashing per manufacturer recommendations. Install new marvin integrity windows with high efficiency glass. Install flashing tape over window flanges per manufacturer recommendations. Use minimal expansion foam insulation between window jamb and framing. Make drywall and paint repairs as needed. Install trim. Permit type: Residential window replacement | Permit status: Issued | Permit id: Bld-15-03318 | |||||
SCORE 64 Remove shingles and roof sheathing. Install moisture guard and titanium felt per manufacturers specifications and code requirements. Replace all roof flashing and roof vents. Install 30-year multi-layer laminated asphalt shingles using six nail pattern for maximum wind rating. Permit type: Residential re-roof | Permit status: Issued | Permit id: Bld-15-03315 | |||||
SCORE 100 American standard 92% 120k furnace, 5 ton a/c, ductwork Date: March 26, 2015 Contractor: Jason Wortman Permit type: Residential air conditioning air distribution systems | Permit status: Issued | Permit id: Mec-15-02127 | |||||
SCORE 64 Remove all existing siding. Install 1/2 inch cellotex tuff-r insulated sheathing. Install type-r air/moisture barrier. Install new fiber cement siding per manufacturer recommendations. Permit type: Residential re-side | Permit status: Issued | Permit id: Bld-15-03316 |