Building Permits at 9155 Rosedale Dr, Spring Valley, Ca 91977


Estimated Price

Beds

Baths

Rooms

Sq.Ft.

Built:   Lot size:   Taxed:
RENOVATION HISTORY
Based on the information received from building department, associated with 9155 Rosedale Dr, Spring Valley, Ca 91977 over the past .

If you are considering hiring for your home renovation project, we recommend using our bidding system to get competitive quotes.

ACTIVITY



PERMITS VALUATION



RENOVATIONS
Find out the best time of the year to complete your project on a minimal budget.
Get several free quotes from best contractors in your area.

REQUEST A QUOTE
Explore CheckPermit
Our dataset includes 30 milion building permits across 4 million addresses in US.

We analyzed and ranked over 1 million home remodeling contractors based on official government sources.

Every contractor's rank is calculated based on official government records.
RECENT PROJECTS


Content Date Cost Contractor Rank Address Contractor
SCORE
95
Roof mount residential solar pv for existing sfd with existing residential main electrical service upgrade - 225a - the scope of work is limited to upgrade of the existing main service panel. No new sub-panels or relocation permitted. Per section 46 (i) of the zoning ordinance, roof mounted photovoltaic systems shall not extend more than 5 ft. Above the highest point of the existing roof.
Date:  November 9, 2016

Permit type: Residential alteration-addn | Permit status: Issued | Permit id: Pds2016-Resalt-
2016/11/090959155 Rosedale Dr Spring Valley Ca 91977Solarcity Corporation
SCORE
88
Re-roof, 700sf if a re-roof project is proposed, the following specifications apply. Existing roofing material asphalt shingles proposed roofing material asphalt shingles manufacturer owens corning brand and model supreme color (if cool roof required) amber built-up roofing assembly system number per attached listing report (if applicable) na specific exemption from cool roof requirements (if applicable) less than 50% replacement. Old roofing to be removed 7 squares required building inspector field verification (if applicable) yes note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector.
Date:  January 20, 2017
Value:   $4,151

Permit type: Residential alteration-addn | Permit status: Issued | Permit id: Pds2017-Resalt-
2017/01/204151889155 Rosedale Dr Spring Valley Ca 91977Noble Roofing And Exteriors Incorporated
SCORE
89
Windows and or sliding glass door replacements with the same net openable area. (replacement windows must meet state of california energy code requirements for u-factor and shgc for package d of the applicable climate zone (see pds #409). Also, per county building code 704a. 3. 2. 2; windows shall be dual-glazed with a minimum of one tempered pane, and glazing frames made of vinyl shall have welded corners and metal reinforcing in the interlock area.)
Date:  July 21, 2016

Permit type: Residential alteration-addn | Permit status: Issued | Permit id: Pds2016-Resalt-
2016/07/210899155 Rosedale Dr Spring Valley Ca 91977The Right Choice Heating And Air Inc
Final
Date:  February 10, 2017

Permit status: Pass | Permit id: Pds2017-Resalt-
2017/02/100959155 Rosedale Dr Spring Valley Ca 91977
Rough electric
Date:  December 29, 2016

Permit status: Pass | Permit id: Pds2016-Resalt-
2016/12/290959155 Rosedale Dr Spring Valley Ca 91977
SCORE
95
Roof mount residential solar pv for existing sfd with existing residential main electrical service upgrade - 225a - the scope of work is limited to upgrade of the existing main service panel. No new sub-panels or relocation permitted. Per section 46 (i) of the zoning ordinance, roof mounted photovoltaic systems shall not extend more than 5 ft. Above the highest point of the existing roof.
Date:  November 9, 2016

Permit type: Res roof mt solar pv | Permit status: Issued | Permit id: Pds2016-Resalt-
2016/11/090959155 Rosedale Dr, Spring Valley, Ca 91977Solarcity Corporation
SCORE
88
Re-roof, 700sf if a re-roof project is proposed, the following specifications apply. Existing roofing material asphalt shingles proposed roofing material asphalt shingles manufacturer owens corning brand and model supreme color (if cool roof required) amber built-up roofing assembly system number per attached listing report (if applicable) na specific exemption from cool roof requirements (if applicable) less than 50% replacement. Old roofing to be removed 7 squares required building inspector field verification (if applicable) yes note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector.
Date:  January 20, 2017
Value:   $4,151

Permit type: Misc. (antennas, tennis cts, gazebo) | Permit status: Issued | Permit id: Pds2017-Resalt- | Parcel: 5041821300
2017/01/204151889155 Rosedale Dr, Spring Valley, Ca 91977Noble Roofing And Exteriors Incorporated
SCORE
89
Windows and or sliding glass door replacements with the same net openable area. (replacement windows must meet state of california energy code requirements for u-factor and shgc for package d of the applicable climate zone (see pds #409). Also, per county building code 704a. 3. 2. 2; windows shall be dual-glazed with a minimum of one tempered pane, and glazing frames made of vinyl shall have welded corners and metal reinforcing in the interlock area.)
Date:  June 16, 2016

Permit type: Glazing replacement - no net area change | Permit status: Issued | Permit id: Pds2016-Resalt-
2016/06/160899155 Rosedale Dr, Spring Valley, Ca 91977The Right Choice Heating And Air Inc
BEST LOCAL CONTRACTORS




Contractor Rank Contractor Details Number of Projects Avg. Project Cost Years in Business Photos
Need a Contractor ?
Just fill out a form below and get several free quotes from best local contractors in your area.