-to paint exterior as follows: walls ... To match 911 dauphine: terra cotta, custom blend, # 277 (as noted on 01/14/ vcc paint permit), flat or eggshell finish trim including doors, windows, columns and rails... Satin white, # 11001, semigloss shutters... Governor nicholls street green, semigloss decking/balcony flooring (top)... Deck grey, # 11271 ironwork.. Black Date: December 2, 2013 Permit type: Vcc paint | Permit status: Permit issued | Expiration date: June 12, 2014 | Current use: Half of a party wall double | Permit id: 13-47426-Vcpnt | |||||
SCORE 70 Replacing 1st flr beam as per engineers sketch. No exterior work allowed. Permit type: Renovation (structural) | Permit status: Permit issued | Expiration date: November 21, 2013 | Current use: Single family | Permit id: 13-15854-Rnvs | |||||
Investigate conditions of masonry & repoint/rebuild as necessary to match existing conditions, using a soft mortar mix with the portland cement content not to exceed 1 part to 12; re-stucco existing stucco walls as necessary, using a soft mortar mix with the portland cement content not to exceed 1 part to 12; reset existing window, rear lake side, ursulines elevation, into correct alignment, retaining/repairing existing jambs & head as necessary; install new wooden drip hood over window, 2nd floor service wing, ursulines elevation, to match existing on ground floor service wing; install new drip hoods over existing openings, courtyard elevation, to match the existing one on side elevation; repair/restore shutters as necessary to match existing conditions (fixed louvers-over-panel on 2nd floor, batten on 1st); and remove low slope built-up roof at infill of service wing and replace, using new built-up roof with copper flashing. Note: the items approved by the vcc (gallery, carriageway e Date: April 11, 2013 Permit type: Vcc general work | Permit status: Permit issued | Expiration date: October 11, 2013 | Current use: Half of a party wall double | Permit id: 13-11384-Vcgen | |||||
SCORE 96 Renovations- 13-15054 Date: September 6, 2013 Contractor: Rafael A. Tejeda Permit type: Electrical service / circuit / feeder | Permit status: Permit issued | Expiration date: March 6, 2014 | Current use: Single family | Permit id: 13-36835-Serv | |||||
Galery repairs to reconstruct gallery and columns per updated plans and details received 08/14/13; approved by architectural committee on 07/23/13, and stamped vcc approved 08/22/13 remove existing crepe myrtle trees and tree wells & planting from sidewalk; repair & paving of sidewalk to be covered under separate permit. Date: August 22, 2013 Permit type: Vcc general work | Permit status: Permit issued | Expiration date: February 22, 2014 | Current use: Single family | Permit id: 13-35432-Vcgen | |||||
SCORE 93 Interior: new electrical, plumbing and hvac, sheetrock, cabinets, countertops and painting. No exterior work under this permit. Permit type: Renovation (non-structural) | Permit status: Permit issued | Expiration date: April 15, 2014 | Current use: Single family | Permit id: 13-40973-Rnvn | |||||
Remove existing non-original iron balcony & install gallery with cast iron railing reconfigure dauphine side carriageway entrance, including new wooden vertical beaded board gates set within vertical beaded board clad wall, per attached detail. Relocate air conditioning equipment from ground location, dauphine carriageway, to elevated platform to be constructed behind proposed wall above carriageway gates, dauphine elevation, per attached detail. Notes: - approval for staff-level work was covered under vcc permit no. 13-11384- this permit does not include approval for the stuccoing of exposed brick surfaces, scoring of stucco, paint or lime wash or other surface treatment - all work must conform to standard vcc policies & guidelines. Date: July 12, 2013 Permit type: Vcc general work | Permit status: Permit issued | Expiration date: January 12, 2014 | Current use: Half of a party wall double | Permit id: 13-30435-Vcgen | |||||
SCORE 93 Construct 2nd floor gallery as per 13-35432-vcgennew electrical, plumbing and hvacnew (interior) sheetrock, cabinets, countertops and painting Permit type: Renovation (non-structural) | Permit status: Application review | Current use: Single family | Permit id: 13-40286-Rnvn | |||||
SCORE 98 Rll-d-lambert-415-6853-3-elec-wh-mo-69199627266 Date: August 23, 2013 Contractor: Daniel Lambert Permit type: General mechanical | Permit status: Permit issued | Expiration date: February 23, 2014 | Current use: Half of a party wall double | Permit id: 13-35455-Mech | |||||
-to install copper drip hoods to match existing drip hoods per ac approval of 08/27/13, and drawings submitted 12/02/13, and stamped vcc approved 12/06/13.-to replace wooden entry-grate on ursulines to match existing per shop drawings submitted 12/02/13, and stamped vcc approved 12/06/13. Date: December 2, 2013 Permit type: Vcc general work | Permit status: Permit issued | Expiration date: June 10, 2014 | Current use: Half of a party wall double | Permit id: 13-47095-Vcgen | |||||
SCORE 96 Renovations- 13-11912 Date: May 1, 2013 Contractor: Rafael A. Tejeda Permit type: Electrical repair / replacement / addition | Permit status: Permit issued | Expiration date: November 1, 2013 | Current use: Half of a party wall double | Permit id: 13-13587-Erpr | |||||
SCORE 86 Rll-m-corcoran-415-3070-4-ac-4-elec-waf-ck-1142 Date: October 31, 2013 Contractor: Mark Corcoran Mark Corcoran Permit type: General mechanical | Permit status: Permit issued | Expiration date: April 30, 2014 | Current use: Half of a party wall double | Permit id: 13-42758-Mech | |||||
SCORE 86 Rll-m-corcoran-415-3070-4-ac-4-elec-waf-ck-1142 Date: October 31, 2013 Contractor: Mark Corcoran, Mark Corcoran Permit type: General mechanical | Permit status: Permit issued | Expiration date: April 30, 2014 | Current use: Half of a party wall double | Permit id: 13-42758-Mech | |||||
Investigate conditions of masonry & repoint rebuild as necessary to match existing conditions, using a soft mortar mix with the portland cement content not to exceed 1 part to 12; re-stucco existing stucco walls as necessary, using a soft mortar mix with the portland cement content not to exceed 1 part to 12; reset existing window, rear lake side, ursulines elevation, into correct alignment, retaining repairing existing jambs & head as necessary; install new wooden drip hood over window, 2nd floor service wing, ursulines elevation, to match existing on ground floor service wing; install new drip hoods over existing openings, courtyard elevation, to match the existing one on side elevation; repair restore shutters as necessary to match existing conditions (fixed louvers-over-panel on 2nd floor, batten on 1st); and remove low slope built-up roof at infill of service wing and replace, using new built-up roof with copper flashing. Note: the items approved by the vcc (gallery, carriageway e Date: April 11, 2013 Permit type: Vcc general work | Permit status: Permit issued | Expiration date: October 11, 2013 | Current use: Half of a party wall double | Permit id: 13-11384-Vcgen | |||||
-to paint exterior as follows: walls ... To match 911 dauphine: terra cotta, custom blend, # 277 (as noted on 01 14 vcc paint permit), flat or eggshell finish trim including doors, windows, columns and rails... Satin white, # 11001, semigloss shutters... Governor nicholls street green, semigloss decking balcony flooring (top)... Deck grey, # 11271 ironwork.. Black Date: December 2, 2013 Permit type: Vcc paint | Permit status: Permit issued | Expiration date: June 12, 2014 | Current use: Half of a party wall double | Permit id: 13-47426-Vcpnt | |||||
Galery repairs to reconstruct gallery and columns per updated plans and details received 08 14 13; approved by architectural committee on 07 23 13, and stamped vcc approved 08 22 13 remove existing crepe myrtle trees and tree wells & planting from sidewalk; repair & paving of sidewalk to be covered under separate permit. Date: August 22, 2013 Permit type: Vcc general work | Permit status: Permit issued | Expiration date: February 22, 2014 | Current use: Single family | Permit id: 13-35432-Vcgen | |||||
-to install copper drip hoods to match existing drip hoods per ac approval of 08 27 13, and drawings submitted 12 02 13, and stamped vcc approved 12 06 13.-to replace wooden entry-grate on ursulines to match existing per shop drawings submitted 12 02 13, and stamped vcc approved 12 06 13. Date: December 2, 2013 Permit type: Vcc general work | Permit status: Permit issued | Expiration date: June 10, 2014 | Current use: Half of a party wall double | Permit id: 13-47095-Vcgen | |||||
Install aztec decking on gallery and balcony; paint Date: August 8, 2017 Value: $2,500 Permit type: Renovation (non-structural) | Permit status: Application submitted | Current use: Single family | Permit id: 17-27235-Rnvn | |||||
Repairing some damaged wood and painting the underside of the gallery. Date: February 24, 2017 Value: $3,500 Permit type: Renovation (non-structural) | Permit status: Application submitted | Current use: Single family | Permit id: 17-06749-Rnvn | |||||
SCORE 63 Remove deteriorated floor boards, stringers and fascia boards. Install new 3" x 4" beaded stringers, 5 4 x 4 t&g floorboards and 7 8" fascia with 1 2" bead, all as per vcc standard detail sheet n. 12 (attached) all repair replacement work shall match existing in size, material, detail, profile and exposure. Uderside of gallery decking and fascia to be painted white, semiglossnote: permit issued in response to violations. Work shall commence no less than days after permit is issued. Work must be completed no less than days after work begins. Owner will call vcc for final inspection upon completion of work. Penalty fees may apply because of improper or unauthorized work. Permit type: Renovation (non-structural) | Permit status: Sub-permits issued | Current use: Single family | Permit id: 17-07424-Rnvn | |||||
Replace deteriorated parapet wall cap with new copper flashing (to match existing) Date: February 6, 2017 Permit type: Vcc general work | Permit status: Permit issued | Expiration date: August 8, 2017 | Current use: Single family | Permit id: 17-03883-Vcgen | |||||
SCORE 89 Replace rusting parapet wall cap with new copper flashing Permit type: Renovation (non-structural) | Permit status: Permit issued | Expiration date: August 10, 2017 | Current use: Single family | Permit id: 17-03883-Rnvn | |||||
Painting of the trim elements, fascia and underside of gallery the vcc approved satin semi gloss white Date: March 7, 2017 Permit type: Vcc paint | Permit status: Voided - duplicate permit | Completion date: March 8, 2017 | Current use: Single family | Permit id: 17-07621-Vcpnt | |||||
Install aztec decking on gallery and balcony; paint Date: August 14, 2017 Permit type: Vcc general work | Permit status: Vcc arc meeting | Current use: Single family | Permit id: 17-27235-Vcgen | |||||
Remove deteriorated floor boards, stringers, and fascia boards. Install new 3"x4" beaded stringers, 5 4x4 t&g floorboards, and 7 8" fascia with " bead, all as per vcc standard detail sheet no. 12 (attached). All repair replacement work shall match existing in color, size, material, detail, profile and exposure Date: March 1, 2017 Permit type: Vcc general work | Permit status: Permit finaled | Completion date: April 24, 2017 | Expiration date: September 2, 2017 | Current use: Single family | Permit id: 17-06749-Vcgen | |||||
Remove deteriorated floor boards, stringers and fascia boards. Install new 3" x 4" beaded stringers, 5 4 x 4 t&g floorboards and 7 8" fascia with 1 2" bead, all as per vcc standard detail sheet n. 12 (attached) all repair replacement work shall match existing in size, material, detail, profile and exposure. Retain first floor trim color french quarter green, semiglossgallery decking... Deck grey, # 11271, semiglossgallery underside and fascia... French quarter green, semiglosssecond floor trim of the main building... French quarter green, semiglossfront door and surrounding panels on ursulines... French quarter green, semiglossironwork... Black, semiglossnote: permit issued in response to violations. Work shall commence no less than days after permit is issued. Work must be completed no less than days after work begins. Owner will call vcc for final inspection upon completion of work. Penalty fees may apply because of improper or unauthorized work. Date: March 8, 2017 Permit type: Vcc general work | Permit status: Permit finaled | Completion date: April 24, 2017 | Expiration date: September 8, 2017 | Current use: Single family | Permit id: 17-07424-Vcgen | |||||
SCORE 93 Renovations to a single dwelling as per 13-11384-vcgen. Masonry restoration: doors, windows, shutters. New drip hoods. Replace roof metal and flashing. Remove/replace stucco and install new bricks on both structures. (1101 dauphine/901 ursulines) Permit type: Renovation (non-structural) | Permit status: Permit issued | Expiration date: October 17, 2013 | Current use: Half of a party wall double | Permit id: 13-11912-Rnvn |