Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Plumbing permit Date: September 8, 2014 Client: Schramex Charles W Schramex Carol N | Permit status: Expired | Permit id: 560133 | |||||
Zoning use permit Date: February 9, 2010 Client: Wisdom Roel Barrington | Permit status: Completed | Permit id: 253486 | |||||
Alteration permit Date: January 12, 2017 Client: Pc2 Llc | Permit status: Active | Permit id: 722393 | |||||
Use permit Date: January 12, 2017 Client: Pc2 Llc | Permit status: Completed | Permit id: 722389 | |||||
SCORE 86 Install 150amp temporary service with 2-quad gfi receptacles from 3 15 17 to 9 15 17 as per 2008 nec (north district) Date: March 15, 2017 Contractor: Talon Fire And Security Sys Llc Client: Pc2 Llc | Permit type: Electrical permit | Permit status: Completed | Completion date: April 26, 2017 | Permit id: 766806 | |||||
SCORE 100 Install new fire suppression system complying with nfpa 13r throughout the second floor dwelling units to include 2" main fire service line and 2" wilkins 350xl backflow prevention assembly as per approved plans. All work shall be performed by a fire suppression contractor licensed by the city of philadelphia. Date: May 16, 2017 Contractor: Oneida Fire Protection Client: Pc2 Llc | Permit type: Suppression permit | Permit status: Completed | Completion date: August 23, 2017 | Permit id: 772766 | |||||
Remove all existing signs. Erect one (1) flatwall sign accessory to insurance office. Date: February 9, 2010 Client: Wisdom Roel Barrington | Permit type: Zoning/use permit | Permit status: Completed | Completion date: February 9, 2010 | Permit id: 253486 | |||||
SCORE 94 Install a 3 4 backflow preventor (dr office) Date: October 21, 2014 Contractor: Rcs Plumbing And Heating Llc Client: Brown Raymond D | Permit type: Plumbing permit | Permit status: Completed | Completion date: September 9, 2015 | Permit id: 569407 | |||||
SCORE 100 Alteration: interior plumbing for prescriptive alterations to (2) dwelling units on the 2nd floor of a 2-story existing structure, with vacant commercial space on the 1st floor. Additional permits are required for the fit-out of the vacant commercial space, except for work that is shown on these approved plans is included in this permit. The installation will comply with the philadelphia plumbing code, 2004 Date: August 10, 2017 Contractor: Gregory F Rossi Plumbing And Htg Client: Pc2 Llc | Permit type: Plumbing permit | Permit status: Completed | Completion date: August 23, 2017 | Permit id: 789558 | |||||
SCORE 89 Install 1" water service 5" lateral, curb trap & fai pa20171082493 self certification no longer accepted all trenches in excess of 5 ft must have approved shoring at the time of inspection. Date: April 26, 2017 Contractor: Leuzzi Mark Client: Pc2 Llc | Permit type: Plumbing permit | Permit status: Completed | Completion date: May 4, 2017 | Permit id: 778318 | |||||
SCORE 86 Install 400amp service,4 socket meter bank,2-125amp and 2-100amp service panels,wiring throughout with recepts,switches,lights,fixtures,smokes and co detectors as per 2008 nec (north district) install a complete fire alarm system with pullstations,horns,strobes,horn strobes and lights as per nfpa72 Date: June 1, 2017 Contractor: Talon Fire And Security Sys Llc Client: Pc2 Llc | Permit type: Electrical permit | Permit status: Completed | Completion date: August 23, 2017 | Permit id: 775102 | |||||
SCORE 99 Install a prz backflow device as per phila water dept (commercial) Date: September 8, 2014 Contractor: Earl D Jay Client: Schramex Charles W Schramex Carol N | Permit type: Plumbing permit | Permit status: Expired | Completion date: September 24, 2015 | Permit id: 560133 | |||||
For use as household living for two (2) families on the same lot as a vacant commercial space @ the 1st floor (use resitration required prior to occupancy) Date: January 12, 2017 Client: Pc2 Llc | Permit type: Use permit | Permit status: Completed | Completion date: January 12, 2017 | Permit id: 722389 | |||||
For prescriptive alterations at exist. Building including demo. Of non-bearing partitions & front facade, erection of partition walls for new dwelling units, vacant commercial space, exit enclosure & all associated finish work; bldg. Is not fully sprinklered. Separate permit reqd for awning install & 1st flr fitout & any mech., elec. & plumb. Work. Premises to comply with all applicable provisions of the phila. Fire & property maint. Codes. Pedestrian protection to be in place prior to start of work. Date: January 12, 2017 Client: Pc2 Llc | Permit type: Alteration permit | Permit status: Completed | Completion date: August 23, 2017 | Permit id: 722393 | |||||
SCORE 82 Ez permit ductwork & warm-air appliances- for the installation of new ductwork, registers grilles diffusers, and warm-air appliances as per attached standard. Deviations from this standard will result in permit revocation and require submission of construction plans. Date: May 24, 2017 Contractor: Aleksandr Prozorov Client: Pc2 Llc | Permit type: Mechanical permit | Permit status: Completed | Completion date: August 22, 2017 | Permit id: 786495 |