Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Plumbing permit Date: March 14, 2016 Client: Lux 8 Investments Llc | Permit status: Active | Permit id: 676141 | |||||
Zoning/use permit Date: February 23, 2010 Client: Lux 8 Investments Llc | Permit status: Completed | Permit id: 256748 | |||||
Demolition permit Date: November 28, 2016 Client: Lux 8 Investments Llc | Permit status: Active | Permit id: 681227 | |||||
Zoning use permit Date: February 23, 2010 Client: Lux 8 Investments Llc | Permit status: Completed | Permit id: 256748 | |||||
Plumbing permit Date: March 14, 2016 Client: Lux 8 Investments Llc | Permit status: Active | Permit id: 676141 | |||||
Alteration permit Date: November 28, 2016 Client: Lux 8 Investments Llc | Permit status: Active | Permit id: 703838 | |||||
SCORE 82 For level iii interior alteration of the existing structure to include the erection of non bearing partitions and finishes. For the change of use to a three (3) family dwelling. Date: October 17, 2017 Contractor: Turner Brothers Plumbing And Htg Client: Lux 8 Investments Llc | Permit type: Plumbing permit | Permit status: Active | Completion date: November 17, 2017 | Permit id: 816813 | |||||
For a change in use for the existing structure to 3 dwelling units Date: July 10, 2017 Client: Lux 8 Investments Llc | Permit type: Use permit | Permit status: Completed | Completion date: July 10, 2017 | Permit id: 797370 | |||||
SCORE 93 For the partial demolition of an attached structure with the removal of front bay window, rear portion of structure, floor roof framing members & assemblies, and the installation of temporary shoring members for support of side exterior walls and front wing walls. Valid streets department permit to be secured for proposed temporary fencing in r. O. W. Pedestrian protection to be provided in accordance with section b-3306. (21 day demo start date waived for i. D. Condition) asbestos investigator to be on-site to verify presence of asbestos. [separate permit to be issued for reconstruction work.] Date: November 28, 2016 Contractor: Rlc Contractors Inc Client: Lux 8 Investments Llc | Permit type: Demolition permit | Permit status: Completed | Completion date: June 29, 2017 | Permit id: 681227 | |||||
SCORE 86 For the reconstruction of a light-framed, three-story attached structure. Work to include the erection of braced wall panels, wall repair and selective replacement, new structural modifications, and exterior wall finishes as shown in approved plans. Temporary steel-framed shoring to be provided for support of 1st story wing wall. Permit issued to comply l+i violation (case no. 388893). (separate permits to be required for fit-out and occupancy.) [see plans under ap#681227] Date: November 28, 2016 Contractor: Pennway Construction Llc Client: Lux 8 Investments Llc | Permit type: Alteration permit | Permit status: Completed | Completion date: June 29, 2017 | Permit id: 703838 | |||||
For level iii interior alteration of the existing structure to include the erection of non bearing partitions and finishes. For the change of use to a three (3) family dwelling. No changes in building height or area. Structure sprinklered per nfpa 13r minimum. Separate permit required for plumbing, mechanical, electrical and fire suppression. Date: August 1, 2017 Client: Lux 8 Investments Llc | Permit type: Alteration permit | Permit status: Active | Completion date: November 17, 2017 | Permit id: 799527 | |||||
For the erection of an attached structure with cellar and front bay window(completely out side the property lines) to use as a three family household living (size and location s shown on plan).(ref. Use permit #797370). Date: November 17, 2017 Client: Lux 8 Investments Llc | Permit type: Zoning/use permit | Permit status: Completed | Completion date: November 17, 2017 | Permit id: 830332 | |||||
SCORE 100 Installation of fa system,smoke detectors,pull station,horn strobes,fire alarm control panel. Run 20amp circuit for fa control panel per nfpa 72(triplex) Date: November 3, 2017 Contractor: Kartman Fire Protection Client: Lux 8 Investments Llc | Permit type: Electrical permit | Permit status: Active | Completion date: November 3, 2017 | Permit id: 820043 | |||||
SCORE 74 Install 3 hvac units with ductwork (multi-family) Date: September 28, 2017 Contractor: Qualitech Heating And Cooling Client: Lux 8 Investments Llc | Permit type: Mechanical permit | Permit status: Active | Completion date: November 9, 2017 | Permit id: 819805 | |||||
SCORE 100 For the installation of a "two (2) inch" fire service line with backflow preventor and automatic fire suppression system as per nfpa 13. All work shall be done in accordance with approved plans hydraulic calculations Date: November 21, 2017 Contractor: B. M. Consulting Services Inc Client: Lux 8 Investments Llc | Permit type: Suppression permit | Permit status: Active | Completion date: November 21, 2017 | Permit id: 820901 | |||||
SCORE 96 Seal existing lateral & fai, remove curb trap for demo pa1# 2016-0740676 "self-certifications are no longer permitted" - "all excavations and plumbing trenches in excess of 5 feet in depth must have approved shoring in place at the time of inspection" Date: March 14, 2016 Contractor: Katilas Plumbing Client: Lux 8 Investments Llc | Permit type: Plumbing permit | Permit status: Completed | Completion date: November 30, 2017 | Permit id: 676141 | |||||
Renovation of existing 3 story bldg. Rear deck added to rear of bldg. Date: February 23, 2010 Client: Lux 8 Investments Llc | Permit type: Zoning/use permit | Permit status: Completed | Completion date: February 23, 2010 | Permit id: 256748 | |||||
SCORE 86 New 300a incoming service gang meter socket 3 meters fro apts 150a per position. 1 meter for house 100a per position. Wiring throughout wiring lights,switches,outlets and battery back up smoke co detectors. Low voltage wiring of phone cable and doorbell per 2008 nec (triplex) no fire on this permit Date: October 23, 2017 Contractor: Sigma Electric Group Inc Client: Lux 8 Investments Llc | Permit type: Electrical permit | Permit status: Active | Completion date: October 23, 2017 | Permit id: 818864 | |||||
SCORE 82 Replace curb trap,fai,exterior main drain and install new 1"water service-pa1#20173241121-"self-certifications are no longer permitted" - "all excavations and plumbing trenches in excess of 5 feet in depth must have approved shoring in place at the time of inspection" Date: November 21, 2017 Contractor: Turner Brothers Plumbing And Htg Client: Lux 8 Investments Llc | Permit type: Plumbing permit | Permit status: Completed | Completion date: December 1, 2017 | Permit id: 834063 |