Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Mechanical permit ![]() Client: Preston Street Properties | Permit status: Active | Permit id: 682956 | |||||
Electrical permit ![]() Client: Preston Street Properties | Permit status: Active | Permit id: 686852 | |||||
Suppression permit ![]() Client: Preston Street Properties | Permit status: Active | Permit id: 655289 | |||||
New construction permit ![]() Client: Preston Street Properties | Permit status: Expired | Permit id: 607992 | |||||
Zoning/use permit ![]() Client: Preston Street Properties | Permit status: Completed | Permit id: 562252 | |||||
Plumbing permit ![]() Client: Preston Street Properties | Permit status: Completed | Permit id: 653004 | |||||
Plumbing permit ![]() Client: Preston Street Properties | Permit status: Active | Permit id: 649391 | |||||
Administrative permit ![]() Client: Preston Street Properties | Permit status: Expired | Permit id: 624599 | |||||
Administrative permit ![]() Client: Preston Street Properties | Permit status: Active | Permit id: 673660 | |||||
Zoning use permit ![]() Client: Preston Street Properties | Permit status: Completed | Permit id: 562252 | |||||
SCORE 96 Install new 6" lateral,house trap,house main,1. 5 water service,1-1 2 backflow. Self (mixed use)pa20153220111 certifications are no longer permitted","all excavations and plumbing trenches in excess of 5 ft in depth must have approved shoring in place at the time of inspection" ![]() ![]() Permit type: Plumbing permit | Permit status: Completed | Completion date: December 12, 2015 | Permit id: 653004 | |||||
SCORE 86 For amendment to permit ap#607992 to revise requirements of the fire suppression system in the building to be installed in accordance with nfpa 2007, standard 13 and 13r suppression systems. ![]() ![]() Permit type: Administrative permit | Permit status: Completed | Completion date: February 28, 2017 | Permit id: 673660 | |||||
For the construction of a four story, multi-family residences with (3) dwellings units from 2nd floor thru 4th floor and office space on first floor ![]() Permit type: Zoning/use permit | Permit status: Completed | Completion date: October 2, 2014 | Permit id: 562252 | |||||
SCORE 86 For the erection of a new light-framed four (4) story structure for the use of three (3) dwelling units and ground floor commercial use. Separate permits to be required for plumbing, electrical, mechanical, fire suppression system. (note: building to be sprinklered in accordance with nfpa 13 suppression system.) (see ap#594816 for associated plans.) ![]() ![]() Permit type: New construction permit | Permit status: Completed | Completion date: July 28, 2017 | Permit id: 607992 | |||||
SCORE 100 For the installation of a two (2) inch fire service line w. Backflow preventor (bfp) assembly and for installation of a fire suppression system as per nfpa 13 and nfpa 13r. All work shall be in accordance with approved plans. Floor layout shall be in accordance with approved building permit. ![]() ![]() Permit type: Suppression permit | Permit status: Completed | Completion date: April 5, 2017 | Permit id: 655289 | |||||
SCORE 86 Install 600amp service & wiring throughout mixed use bldg as per nec 2008 west district & install fire alarm as per nfpa 72 ![]() ![]() Permit type: Electrical permit | Permit status: Completed | Completion date: April 17, 2017 | Permit id: 686852 | |||||
SCORE 100 Install (5) hvac systems with ductwork. (mixed-use) ![]() ![]() Permit type: Mechanical permit | Permit status: Completed | Completion date: February 28, 2017 | Permit id: 682956 | |||||
SCORE 86 Amend permit ap#607992 for the installation of underpinning of foundation at 529 n budd st. Licensed professional engineer on record to be on-site to conduct continuous special inspections per code bulletin b-0503. Per code bulletin b-0702, written notice shall be provided to the owners of the adjoining property advising them that the excavation is to be made and that adjoining buildings should be protected, to be delivered not less than ten (10) days prior to the scheduled start date of the excavation. ![]() ![]() Permit type: Administrative permit | Permit status: Completed | Completion date: February 28, 2017 | Permit id: 624599 | |||||
SCORE 95 Interior plumbing construction for a new (4)story structure for the use of three (3)dwelling units and ground floor commercial use to a point 5-0" outside only- a scupper will be installed to satisfy the secondary roof drainage requirements of the 2009 international building code section 1503. 5 and the 2009 international plumbing code section 1107 - note: separate permit applications required for house trap, water distribution, sewer water connections to the city mains and the installation of the 1-1 2" backflow prevention containment device at the water meter - the installation will comply with the approved plans and the philadelphia plumbing code 2004 ![]() ![]() Permit type: Plumbing permit | Permit status: Completed | Completion date: July 28, 2017 | Permit id: 649391 |