Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Addition permit Date: January 16, 2013 Client: Jacob Aurora C | Permit status: Active | Permit id: 419606 | |||||
Demolition permit Date: October 25, 2012 Client: Jacob Aurora C | Permit status: Completed | Permit id: 434771 | |||||
Alteration permit Date: October 25, 2012 Client: Jacob Aurora C | Permit status: Completed | Permit id: 434770 | |||||
Mechanical permit Date: June 8, 2016 Client: Jacob Aurora C | Permit status: Active | Permit id: 698207 | |||||
Plumbing permit Date: August 2, 2016 Client: Jacob Aurora C | Permit status: Active | Permit id: 704805 | |||||
Electrical permit Date: May 13, 2016 Client: Jacob Aurora C | Permit status: Active | Permit id: 685031 | |||||
Suppression permit Date: November 12, 2015 Client: Jacob Aurora C | Permit status: Active | Permit id: 644598 | |||||
Demolition permit Date: August 9, 2010 Client: Jacob Aurora C | Permit status: Completed | Permit id: 295229 | |||||
Zoning admin review Date: July 31, 2012 Client: Jacob Aurora C | Permit status: Completed | Permit id: 394981 | |||||
Zoning/use permit Date: April 1, 2011 Client: Jacob Aurora C | Permit status: Completed | Permit id: 309086 | |||||
Permit for the partial demolition of rear one (1) story portion, for the erection of a 3rd story addition over existing two (2) story portion and a two (2) story addition over existing one (1) story portion, for a 4th story addition, max overall height 43 ft 9 inches, for a roof deck, deck with a min of 42 inch protective railing, all for use as a proposed three (3) family dwelling. Date: December 10, 2010 Client: Jacob Aurora C | Applicant: Angela S. Diprima-Bucci | Permit type: Appeal | Permit status: Granted | Completion date: March 22, 2011 | Permit id: 14102 | |||||
Electrical permit Date: January 27, 2016 Client: Jacob Aurora C | Permit status: Completed | Permit id: 665943 | |||||
Demolition permit Date: August 9, 2010 Client: Jacob Aurora C | Permit status: Completed | Permit id: 295229 | |||||
Demolition permit Date: October 25, 2012 Client: Jacob Aurora C | Permit status: Completed | Permit id: 434771 | |||||
Zoning use permit Date: April 1, 2011 Client: Jacob Aurora C | Permit status: Completed | Permit id: 309086 | |||||
Mechanical permit Date: June 8, 2016 Client: Jacob Aurora C | Permit status: Active | Permit id: 698207 | |||||
Plumbing permit Date: August 2, 2016 Client: Jacob Aurora C | Permit status: Active | Permit id: 704805 | |||||
Administrative permit Date: December 2, 2016 Client: Jacob Aurora C | Permit status: Active | Permit id: 730933 | |||||
Suppression permit Date: November 12, 2015 Client: Jacob Aurora C | Permit status: Active | Permit id: 644598 | |||||
Alteration permit Date: October 25, 2012 Client: Jacob Aurora C | Permit status: Completed | Permit id: 434770 | |||||
Zoning admin review Date: July 31, 2012 Client: Jacob Aurora C | Permit status: Completed | Permit id: 394981 | |||||
Addition permit Date: January 16, 2013 Client: Jacob Aurora C | Permit status: Active | Permit id: 419606 | |||||
Permit for the partial demolition of rear one (1) story portion, for the erection of a 3rd story addition over existing two (2) story portion and a two (2) story addition over existing one (1) story portion, for a 4th story addition, max overall height 43 ft 9 inches, for a roof deck, deck with a min of 42 inch protective railing, all for use as a proposed three (3) family dwelling. Date: December 10, 2010 Client: Jacob Aurora C | Applicant: Angela S. Diprima-Bucci | Permit type: Appeal | Permit status: Granted | Completion date: March 22, 2011 | Permit id: 14102 | |||||
SCORE 96 Demo all walls & ceiling , remove all carpet from floors,remove all interior doors,trim,jamb and demo kitchen & bathroom not structural work on this permit Date: August 9, 2010 Contractor: Blaise Construction Client: Jacob Aurora C | Permit type: Demolition permit | Permit status: Completed | Completion date: May 7, 2014 | Permit id: 295229 | |||||
Removal of 1 story rear section, construction of a 3 story rear section, addition to rear of 3rd fl, construction of penthouse to roof deck Date: April 1, 2011 Client: Jacob Aurora C | Permit type: Zoning/use permit | Permit status: Completed | Completion date: July 17, 2012 | Permit id: 309086 | |||||
SCORE 92 Extension of time permit of ap#309086. Date: July 31, 2012 Contractor: Preston General Contracting Client: Jacob Aurora C | Permit type: Zoning admin review | Permit status: Completed | Completion date: July 31, 2012 | Permit id: 394981 | |||||
SCORE 90 Partial demolition and erection of one (1) and two (2) story rear additions above existing structure and interior alterations per plans; building is to be fully sprinklered. Separate permits required for fire suppression system and any mechanical, electrical and plumbing work. Date: January 16, 2013 Contractor: L And H General Contractor, Llc Client: Jacob Aurora C | Permit type: Addition permit | Permit status: Expired | Completion date: March 31, 2017 | Permit id: 419606 | |||||
SCORE 92 Remove and install 15 windows, front and side and remove and install 3 doors, all in existing openings(3 family dwelling) Date: October 25, 2012 Contractor: Preston General Contracting Client: Jacob Aurora C | Permit type: Alteration permit | Permit status: Completed | Completion date: February 14, 2013 | Permit id: 434770 | |||||
SCORE 92 Interior demolition, non-load bearing partitions only, no structural work allowed on this permit(3 family dwelling) Date: October 25, 2012 Contractor: Preston General Contracting Client: Jacob Aurora C | Permit type: Demolition permit | Permit status: Completed | Completion date: January 28, 2013 | Permit id: 434771 | |||||
SCORE 90 Complete all electrical wiring with 4-1 amp panels. Apply to 3 family building (total of 4 amp) as per nec 2008 south district & fire alarm system as per nfpa 72 Date: May 13, 2016 Contractor: L And H General Contractor, Llc Client: Jacob Aurora C | Permit type: Electrical permit | Permit status: Expired | Completion date: May 13, 2016 | Permit id: 685031 | |||||
SCORE 90 Rewire throughout per 2008 nec (sfd) no service work Date: January 27, 2016 Contractor: L And H General Contractor, Llc Client: Jacob Aurora C | Permit type: Electrical permit | Permit status: Completed | Completion date: April 28, 2016 | Permit id: 665943 | |||||
SCORE 100 For the installation of an automatic fire suppression system throughout a four-story residential structure in accordance with nfpa 13r standards. System to be provided via a 2" fire service main line. Date: November 12, 2015 Contractor: B. M. Consulting Services Inc Client: Jacob Aurora C | Permit type: Suppression permit | Permit status: Active | Completion date: August 16, 2017 | Permit id: 644598 | |||||
SCORE 100 Install 3 heat pumps one 2. 5 ton in basement, install one 2. 5 ton heat pump on 2nd fl, and install one 2. 5 ton heat pump on 3rd fl Date: June 8, 2016 Contractor: Vyacheslav Zhurko Client: Jacob Aurora C | Permit type: Mechanical permit | Permit status: Active | Completion date: August 16, 2017 | Permit id: 698207 | |||||
SCORE 100 Addition alteration: interior plumbing for a 3-story, (3) dwelling unit building. The installation will comply with the philadelphia plumbing code, 2004. A separate permit is required for the 5" sewer lateral & the 1" domestic water distribution service to the street mains, as well as the 1" backflow prevention containment assembly. Fuel gas piping is not part of this permit and will require a mechanical permit. Date: August 2, 2016 Contractor: Superior Build Maintenance Client: Jacob Aurora C | Permit type: Plumbing permit | Permit status: Active | Completion date: August 16, 2017 | Permit id: 704805 | |||||
SCORE 90 Amendment of building permit # 419606, issued january 6, 2013, for the modification to non-bearing interior partition layouts and to document ar reduction at the exit enclosure to a one (1) hour rating for connection of three (3) floors maximum, one (1) hour assembly required above basement stair otherwise 2 hour assembly shall be retained. Pe shall field certify any incidental framing changes as a result of as-built stair configuration; separate zoning permit required to eliminate prior roof deck. Date: December 2, 2016 Contractor: L And H General Contractor, Llc Client: Jacob Aurora C | Permit type: Administrative permit | Permit status: Expired | Completion date: June 2, 2017 | Permit id: 730933 |