Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Install 55ft of electrical wire at 32 bladensburg rd ne, east of eastern ave, as indicated on attached prints wr 3472376 jjablasone,td2 Date: July 6, 2015 Client: Pepco Holdings Inc | Permit type: Over head work; stri | Permit id: Pa112574 | |||||
SCORE 95 Install 55ft of electrical wire at 32 bladensburg rd ne, east of eastern ave, as indicated on attached prints wr 3472376 jjablasone,td2 Date: July 6, 2015 Contractor: Pepco Holdings Inc Permit type: Over head work; string electrical wire | Permit status: Permit expired | Expiration date: February 8, 2016 | Permit id: Pa112574 | |||||
SCORE 95 Install 55ft of electrical wire at 32 bladensburg rd ne, east of eastern ave, as indicated on attached prints wr 3472376 - luke detert - dac Date: March 8, 2016 Contractor: Pepco Holdings Inc Permit type: Over head work; string electrical wire | Permit status: Issued | Expiration date: November 4, 2016 | Permit id: Pa124330 | |||||
SCORE 86 Place 1-4x4x4 at&t manhole and 319 of 1-4" pvc conduit from (prop. At&t manhole) to (washington dc & prince georges county line on bladensburg road, ne. This project will require that a saw cut be made at the construction area and to excavate to the required depth to make the repair then to start backfilling with a dry, clean fill in 8 inch lifts. They will use a vibratory tamper on each lift. At subgrade they wil use 30 psi concrete and vibrate the concrete. Under no circumstances will the open area be left open at night but will be steel plated and filled with temporary asphalt to have a smooth transition to the street. Restore fully in kind any disturbed roadway sidewalk grass areas curb and gutter to match existing finish condition. All work will adhere to all dc guideslines, standards and specifications. Date: December 8, 2011 Contractor: At And T Corp. At And T Corp Permit type: Excavation; manhole installation, excavation; telecom ml conduits (trench) | Permit status: Permit expired | Expiration date: June 30, 2012 | Permit id: Pa62685-R2 | |||||
SCORE 95 Over head work; string electrical wire Date: April 28, 2016 Contractor: Pepco Holdings Inc Permit status: 8 | Expiration date: November 4, 2016 | Permit id: Pa124330 | |||||
SCORE 86 Place 1-4x4x4 at&t manhole and 319 of 1-4" pvc conduit from (prop. At&t manhole) to (washington dc & prince georges county line on bladensburg road, ne. This project will require that a saw cut be made at the construction area and to excavate to the required depth to make the repair then to start backfilling with a dry, clean fill in 8 inch lifts. They will use a vibratory tamper on each lift. At subgrade they wil use 30 psi concrete and vibrate the concrete. Under no circumstances will the open area be left open at night but will be steel plated and filled with temporary asphalt to have a smooth transition to the street. Restore fully in kind any disturbed roadway/ sidewalk/grass areas/curb and gutter to match existing finish condition. All work will adhere to all dc guideslines, standards and specifications. Date: May 24, 2011 Contractor: At And T Corp. At And T Corp Permit type: Excavation; manhole installation, excavation; telecom ml conduits (trench) | Permit status: Permit expired | Expiration date: September 17, 2011 | Permit id: Pa62685 | |||||
SCORE 95 Place 22ft of 1-4" conduit from ex vz mh #2505 to prop at&t mh ward 5 Date: July 7, 2011 Contractor: Verizon Permit type: Excavation; telecom connection (trench) | Permit status: Permit expired | Expiration date: November 8, 2011 | Permit id: Pa63910 | |||||
SCORE 86 Place 1-4x4x4 at&t manhole and 319 of 1-4" pvc conduit from (prop. At&t manhole) to (washington dc & prince georges county line on bladensburg road, ne. This project will require that a saw cut be made at the construction area and to excavate to the required depth to make the repair then to start backfilling with a dry, clean fill in 8 inch lifts. They will use a vibratory tamper on each lift. At subgrade they wil use 30 psi concrete and vibrate the concrete. Under no circumstances will the open area be left open at night but will be steel plated and filled with temporary asphalt to have a smooth transition to the street. Restore fully in kind any disturbed roadway/ sidewalk/grass areas/curb and gutter to match existing finish condition. All work will adhere to all dc guideslines, standards and specifications. Date: August 22, 2011 Contractor: At And T Corp. At And T Corp Permit type: Excavation; manhole installation, excavation; telecom ml conduits (trench) | Permit status: Permit expired | Expiration date: December 26, 2011 | Permit id: Pa62685-R1 | |||||
SCORE 95 Install 55ft of electrical wire at 32 bladensburg rd ne, east of eastern ave, as indicated on attached prints wr 3472376 jjablasone,td2 Date: July 23, 2015 Contractor: Pepco Holdings Inc Permit status: Permit expired | Expiration date: February 8, 2016 | Permit id: Pa112574 | |||||
SCORE 93 Steel plate- single location Date: July 20, 2012 Contractor: At And T Corp Permit status: Expired | Expiration date: August 1, 2012 | Permit id: Pa10066886 | |||||
SCORE 86 Place 1-4x4x4 at&t manhole. Place 3 of 1-4 pvc conduit. This construction permit requires a separate occupancy permit. The attached plans and conditions are a part of this permit. If steel plates are used at this job site an additional permit is needed. Date: June 20, 2012 Contractor: At And T Corp. At And T Corp Permit type: Excavation; manhole installation, excavation; telecom ml conduits (trench) | Permit status: Permit expired | Expiration date: September 21, 2012 | Permit id: Pa72998 |