Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Electrical permit Date: May 26, 2015 Permit status: Expired | Permit id: 612706 | |||||
Alteration permit Date: May 1, 2014 Permit status: Completed | Permit id: 533992 | |||||
Zoning permit Date: November 26, 2013 Permit status: Completed | Permit id: 506733 | |||||
Mechanical permit Date: August 3, 2015 Permit status: Completed | Permit id: 629220 | |||||
Plumbing permit Date: April 21, 2015 Permit status: Completed | Permit id: 604388 | |||||
Zoning permit Date: September 5, 2014 Permit status: Completed | Permit id: 542285 | |||||
Administrative permit Date: May 12, 2016 Permit status: Completed | Permit id: 666806 | |||||
Alteration permit Date: May 22, 2015 Permit status: Completed | Permit id: 591868 | |||||
Permit for proposing a 3rd floor addition with a rear deck and a roof top deck on top of the 3rd floor (size and location to be as shown in application) as part of an existing single family attached dwelling Date: March 24, 2014 Applicant: Vern Anastasio, Esq | Permit type: Appeal | Permit status: Continued | Permit id: 22478 | |||||
Plumbing permit Date: April 21, 2015 Client: E & A Philly Llc | Permit status: Completed | Permit id: 604388 | |||||
Mechanical permit Date: August 3, 2015 Client: E & A Philly Llc | Permit status: Completed | Permit id: 629220 | |||||
Administrative permit Date: May 12, 2016 Client: E & A Philly Llc | Permit status: Completed | Permit id: 666806 | |||||
Electrical permit Date: May 26, 2015 Client: E & A Philly Llc | Permit status: Expired | Permit id: 612706 | |||||
Zoning permit Date: November 26, 2013 Client: E & A Philly Llc | Permit status: Completed | Permit id: 506733 | |||||
Zoning permit Date: September 5, 2014 Client: E & A Philly Llc | Permit status: Completed | Permit id: 542285 | |||||
Alteration permit Date: May 1, 2014 Client: E & A Philly Llc | Permit status: Completed | Permit id: 533992 | |||||
Alteration permit Date: May 22, 2015 Client: E & A Philly Llc | Permit status: Completed | Permit id: 591868 | |||||
Permit for proposing a 3rd floor addition with a rear deck and a roof top deck on top of the 3rd floor (size and location to be as shown in application) as part of an existing single family attached dwelling Date: March 24, 2014 Client: E & A Philly Llc | Applicant: Vern Anastasio, Esq | Permit type: Appeal | Permit status: Continued | Permit id: 22478 | |||||
SCORE 99 One unit. 80,0 btu - ac 4 ton. Ez permit ductwork & warm-air appliances- for the installation of new ductwork, registers grilles diffusers, and warm-air appliances as per attached standard. Deviations from this standard will result in permit revocation and require submission of construction plans. Date: August 3, 2015 Contractor: Moyas Construction Corp Client: Shields Alisa J Shields Jonathan | Permit type: Mechanical permit | Permit status: Completed | Completion date: March 14, 2016 | Permit id: 629220 | |||||
SCORE 100 Water & drains for 1 kitchen sinks, 1 washing machines, 3 water closets, 3 lavy sinks, 3 tubs - the installation will compy with the philadephia plubming code 2004 Date: April 21, 2015 Contractor: Shegda Construction Corp Client: Shields Alisa J Shields Jonathan | Permit type: Plumbing permit | Permit status: Completed | Completion date: March 21, 2016 | Permit id: 604388 | |||||
Creation of a third story to existing sfd Date: November 26, 2013 Client: Shields Alisa J Shields Jonathan | Permit type: Zoning permit | Permit status: Completed | Completion date: November 26, 2013 | Permit id: 506733 | |||||
SCORE 99 Masonry front wall with veneer - remove existing brick front wall and rear wall. Frame new walls with 2 x 6 studs and plywood sheathing. New framing to be structurally fastened to existing party walls and inspected prior to starting brickwork. Foundation wall to extend to first floor at 8 inch width. Start 4 inch brick veneer at first floor level, install brick ties every 32 inches, vertical and horizontal. Physically tie in every 4 feet at adjoining wall. Windows and door same location. Install capping, flashing and weep holes as per code requirements. Complete one wall at a time and call inspector for and schedule an initial inspection prior to the start of work. Contact streets department for dumpster permit and footway closure Date: May 1, 2014 Contractor: Moyas Construction Corp Client: Shields Alisa J Shields Jonathan | Permit type: Alteration permit | Permit status: Completed | Completion date: August 15, 2015 | Permit id: 533992 | |||||
SCORE 89 Install 200amp service, partial rewire outlets, lights, switches and smoke detectors as per 2008 nec (south district) Date: May 26, 2015 Contractor: Digno Disla Client: Shields Alisa J Shields Jonathan | Permit type: Electrical permit | Permit status: Expired | Completion date: May 26, 2015 | Permit id: 612706 | |||||
SCORE 99 Existing two story single family home, proposing a third floor with a roof top deck. Date: May 22, 2015 Contractor: Moyas Construction Corp Client: Shields Alisa J Shields Jonathan | Permit type: Alteration permit | Permit status: Completed | Completion date: March 14, 2016 | Permit id: 591868 | |||||
Amend permit #517371-construct a 3rd floor addition with 8 foot set back from front on an existing single family dwelling with rear deck accessed by spiral stairs from 2nd floor rear, size and location as shown on attached plans. Date: September 5, 2014 Client: Shields Alisa J Shields Jonathan | Permit type: Zoning permit | Permit status: Completed | Completion date: September 5, 2014 | Permit id: 542285 |