Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Electrical permit Date: January 17, 2014 Client: Reithmiller Robert J Reithmiller Miller M | Permit status: Expired | Permit id: 515776 | |||||
Mechanical permit Date: October 21, 2013 Client: Reithmiller Robert J Reithmiller Miller M | Permit status: Completed | Permit id: 501421 | |||||
Alteration permit Date: November 21, 2013 Client: Reithmiller Robert J Reithmiller Miller M | Permit status: Completed | Permit id: 501434 | |||||
Electrical permit Date: February 19, 2013 Client: Reithmiller Robert J Reithmiller Miller M | Permit status: Completed | Permit id: 453145 | |||||
Electrical permit Date: January 17, 2014 Client: Reithmiller Robert J Reithmiller Miller M | Permit status: Expired | Permit id: 515776 | |||||
Alteration permit Date: November 21, 2013 Client: Reithmiller Robert J Reithmiller Miller M | Permit status: Completed | Permit id: 501434 | |||||
Mechanical permit Date: October 21, 2013 Client: Reithmiller Robert J Reithmiller Miller M | Permit status: Completed | Permit id: 501421 | |||||
Electrical permit Date: February 19, 2013 Client: Reithmiller Robert J Reithmiller Miller M | Permit status: Completed | Permit id: 453145 | |||||
SCORE 100 Install (9) 20a, 120v duplex convenience receptacles tied in to three existing circuits (see alt permit #501434)... In accordance with 2008 nec Date: January 17, 2014 Contractor: H. R. Benjamin Inc Client: Reithmiller Robert J Reithmiller Miller M | Permit type: Electrical permit | Permit status: Expired | Completion date: January 17, 2014 | Permit id: 515776 | |||||
SCORE 100 Replace in kind: 3 kva, 480v transformer (demand is less than 100v)... In accordance with 2008 nec Date: October 7, 2014 Contractor: H. R. Benjamin Inc Client: Reithmiller Robert J Reithmiller Miller M | Permit type: Electrical permit | Permit status: Expired | Completion date: October 7, 2014 | Permit id: 566096 | |||||
SCORE 95 Installation of new fire alarm system and new burglar alarm system per 2008 nec & nfpa 72 (manufacturing) Date: August 27, 2014 Contractor: Tyco Integrated Security Llc Client: Reithmiller Robert J Reithmiller Miller M | Permit type: Electrical permit | Permit status: Expired | Completion date: August 27, 2014 | Permit id: 551161 | |||||
SCORE 99 Repalce two 5 ton units with ductwork within existng office space are less than 2000cfm no penetration of fire rated assemblies registers diffusers Date: October 21, 2013 Contractor: Abriola Company Client: Reithmiller Robert J Reithmiller Miller M | Permit type: Mechanical permit | Permit status: Completed | Completion date: March 19, 2016 | Permit id: 501421 | |||||
SCORE 100 Install (6) fluores. Light fixtures on one new 20a circuits with 20a toggle switch... Replace existing 200a single phase load center in kind... In accordance with 2008 nec Date: February 19, 2013 Contractor: H. R. Benjamin Inc Client: Reithmiller Robert J Reithmiller Miller M | Permit type: Electrical permit | Permit status: Completed | Completion date: June 24, 2013 | Permit id: 453145 | |||||
SCORE 99 Alteration to existing office to include exterior wall reconstruction and replacement drop ceiling. Asbestos removal required prior to the start of work. Date: November 21, 2013 Contractor: Abriola Company Client: Reithmiller Robert J Reithmiller Miller M | Permit type: Alteration permit | Permit status: Completed | Completion date: June 1, 2015 | Permit id: 501434 |