Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Plumbing permit ![]() Client: Wm Penn Realty | Permit status: Active | Permit id: 674881 | |||||
Zoning/use permit ![]() Client: Wm Penn Realty | Permit status: Completed | Permit id: 675160 | |||||
Demolition permit ![]() Client: Wm Penn Realty | Permit status: Completed | Permit id: 675158 | |||||
Zoning use permit ![]() Permit status: Completed | Permit id: 675160 | |||||
Plumbing permit ![]() Permit status: Completed | Permit id: 674881 | |||||
Electrical permit ![]() Permit status: Active | Permit id: 753818 | |||||
Demolition permit ![]() Permit status: Completed | Permit id: 675158 | |||||
SCORE 86 Seal off sewer lateral and remove house trap pa20160621544(sfd)self certifications are no longer permitted","all excavations and plumbing trenches in excess of 5 ft in depth must have approved shoring in place at the time of inspection" ![]() ![]() Permit type: Plumbing permit | Permit status: Completed | Completion date: October 13, 2016 | Permit id: 674881 | |||||
Proposed work is new construction to repair existing fire damaged building to its pre existing condition. The entire 4th floor and roof shall be replaced to pre fire condition. 1st 2nd and 3rd floor onterior structutal elements shall be repaired and replaced. This includes bay windows on van pelt street. ![]() Permit type: Zoning/use permit | Permit status: Completed | Completion date: March 6, 2017 | Permit id: 750044 | |||||
SCORE 99 For complete demolition of existing building & to document fire damage to remove greater than 2 3rds of the building framing & for removal of exterior building walls at 4th floor level due to fire at building; size & location as shown in application with exterior dimensions below 4th floor to remain unchanged. Use registration required prior to occupancy. ![]() ![]() Permit type: Zoning/use permit | Permit status: Completed | Completion date: August 22, 2017 | Permit id: 675160 | |||||
SCORE 100 For the reconstruction of an existing structure due to damage caused by fire. Work to include structural framing work, building envelope work, new roof, new exterior walls, and all other work as per approved plans historical commission approval. Separate permit required for fit-out and certificate of occupancy asbestos abatement required prior to commencement of work a covered walkway or sidewalk closure shall be required within 12. 5 feet of building facade in accordance with section 3306 of the ibc. Separate building and or streets department permits are required ![]() ![]() Permit type: New construction permit | Permit status: Active | Completion date: July 25, 2017 | Permit id: 733881 | |||||
SCORE 100 16 toilets,16 lavs,16 kitchen sinks,16 tubs,16 washer,16 hub drains (multi family)the installation will comply with the philadelphia plumbing code 2004 ![]() ![]() Permit type: Plumbing permit | Permit status: Active | Completion date: November 27, 2017 | Permit id: 809302 | |||||
SCORE 100 Install 1 amp temporary service with 200amp main breaker ,24 circuit panel and ground rod as per 2008 nec (cc district) ![]() ![]() Permit type: Electrical permit | Permit status: Completed | Completion date: May 15, 2017 | Permit id: 753818 | |||||
For the fit-out of a reconstructed, historically-designated four (4) story building to be re-used as multi-family household living (sixteen (16) dwelling units), as per plans and phc approvals; separate permits required for all mep fsp work; to be fully sprinklered throughout as per nfpa 13, and with standpipes within the exit stairways installed as per nfpa 14. A covered walkway or sidewalk closure shall be required within 12. 5 feet of building facade in accordance with section 3306 of the ibc. Separate building and or streets department permits are required ![]() Permit type: New construction permit | Permit status: Active | Completion date: November 17, 2017 | Permit id: 793385 | |||||
SCORE 99 To demolish structural framing & partial exterior walls of a four (4) story, w. Basement, multi-family bldg. Of masonry bearing wall, structural steel & wood floor roof framed construction due to structural damage caused by fire. All permitted work to be in accordance with approved site safety demolition plan & all applicable provisions of the philadelphia code; site safety plan to be maintained on site at all times. Work must begin w in 48-hrs & continue until the structure is deemed safe by the dept. Failure to comply will render this permit invalid & result in prosecution & or abatement of the dangerous condition by the city at the owners expense. Methods of protection of the public way & adjacent structures are to be implemented immediately. ![]() ![]() Permit type: Demolition permit | Permit status: Completed | Completion date: July 26, 2016 | Permit id: 675158 | |||||
Cellar use to commercial utility and storage cellar -4th floor use to 16 residential apts (reduce from 21 dwelling units) ![]() Permit type: Use permit | Permit status: Completed | Completion date: October 26, 2017 | Permit id: 827114 | |||||
SCORE 100 Installation of a fire suppression system. 4" fire service. New pipe, hangers, and fittings. New city approved backflow prevention assembly. New fire department connection. Sprinklers system throughout building in accordance with nfpa 13 standpipe installation in accordance with nfpa 14 fdc to be located to right of doorway, centered within one brick panel ![]() ![]() Permit type: Suppression permit | Permit status: Active | Completion date: December 14, 2017 | Permit id: 819395 |