Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
SCORE 56 General repairs single-family dwelling repair termite damage to floor and walls as needed, sheetrock and paint interior no exterior work to be done. Date: March 5, 2001 Contractor: Dr. Guido Sutter Client: Sutter, Guido A | Permit id: B01001107 | |||||
Repoint accessory building gov. Nicholls side masonry wall as needed, using vcc approved mortar formula. Mortar: no more than 1 part portland cement, to 3 parts lime, 9 parts sand, and enough water to form a workable mix. Prepackaged mixes are not permitted. The resulting mortar should range in color from white to beige but should not be grey in color. Stucco: base coat consists of 2 coats, doubled up work of 5/8" total thickness. Proportioned as follows: no greater than 1:12 part portland cement, to 3 parts lime, and 9 parts sand, 6 lbs./cubic yard hair or fiber, and enough water to form a workable mix. Finish coat is 1/4" in total thickness proportioned as follows: no more than 1 part portland cement, 3 parts lime, 9 parts sand, enough water to form a workable mix. The resulting mix should range in color from white to beige but should not be grey in color. Note: ratio of portland cement not to exceed 1:12. Date: March 3, 2016 Permit type: Vcc general work | Permit status: Permit issued | Expiration date: September 3, 2016 | Current use: Half of a party wall double | Permit id: 16-06989-Vcgen | |||||
Repoint accessory building gov. Nicholls side masonry wall as needed, using vcc approved mortar formula. Mortar: no more than 1 part portland cement, to 3 parts lime, 9 parts sand, and enough water to form a workable mix. Prepackaged mixes are not permitted. The resulting mortar should range in color from white to beige but should not be grey in color. Stucco: base coat consists of 2 coats, doubled up work of 5 8" total thickness. Proportioned as follows: no greater than 1:12 part portland cement, to 3 parts lime, and 9 parts sand, 6 lbs. Cubic yard hair or fiber, and enough water to form a workable mix. Finish coat is 1 4" in total thickness proportioned as follows: no more than 1 part portland cement, 3 parts lime, 9 parts sand, enough water to form a workable mix. The resulting mix should range in color from white to beige but should not be grey in color. Note: ratio of portland cement not to exceed 1:12. Date: March 3, 2016 Permit type: Vcc general work | Permit status: Permit issued | Expiration date: September 3, 2016 | Current use: Half of a party wall double | Permit id: 16-06989-Vcgen | |||||
SCORE 56 Cert. Of occupancy-no work to be done home based business certificate of occupancy for home based business; women entrepreneurs,inc.; management consultant Date: April 14, 1999 Contractor: Women Entrepreneurs Inc Client: Pete, Keith M | Permit id: B99001822 | |||||
SCORE 96 Renovation 14-21422-rnvn Date: July 25, 2014 Contractor: John Gregory Grillot Permit type: Electrical repair / replacement / addition | Permit status: Permit issued | Expiration date: January 25, 2015 | Current use: Single family | Permit id: 14-23289-Erpr | |||||
R/r siding Date: September 23, 2013 Permit type: Hdlc coa | Permit status: Permit issued | Expiration date: March 23, 2014 | Current use: Single family | Permit id: 13-38699-Hdlc | |||||
SCORE 96 Build out gutted house into 3 bedroom, two bathroom single family residence. New sheetrock, interior trim, insulation, painting, hvac, kitchen and bath cabinets. No exterior work allowed under this permit. Permit type: Renovation (non-structural) | Permit status: Certificate of occupancy | Completion date: December 19, 2014 | Expiration date: January 10, 2015 | Current use: Single family | Permit id: 14-21422-Rnvn | |||||
SCORE 86 Install gas warm air furnace and 4 a/c. Webb johnson (#50217) 504-312-206514-21422-rnvn Date: December 4, 2014 Contractor: Webb Charles Johnson Webb Charles Johnson Permit type: General mechanical | Permit status: Certificate of completion | Completion date: December 5, 2014 | Expiration date: June 4, 2015 | Current use: Single family | Permit id: 14-37534-Mech | |||||
SCORE 56 Cert. Of occupancy-no work to be done home based business certificate of occupancy for home based business; women entrepreneurs,inc.; management consultant Date: April 14, 1999 Contractor: Women Entrepreneurs,Inc Client: Pete, Keith M | Permit id: B99001822 | |||||
SCORE 86 Install gas warm air furnace and 4 a c. Webb johnson (#50217) 504-312-206514-21422-rnvn Date: December 4, 2014 Contractor: Webb Charles Johnson, Webb Charles Johnson Permit type: General mechanical | Permit status: Certificate of completion | Completion date: December 5, 2014 | Expiration date: June 4, 2015 | Current use: Single family | Permit id: 14-37534-Mech | |||||
R r siding Date: September 23, 2013 Permit type: Hdlc coa | Permit status: Permit issued | Expiration date: March 23, 2014 | Current use: Single family | Permit id: 13-38699-Hdlc | |||||
SCORE 93 Gas line/ gas wh/ tony915-4004/ ck5797/ 302/ 14-21422-rnvnreleased meter Date: November 21, 2014 Contractor: Anthony Moret Jr Permit type: General mechanical | Permit status: Certificate of completion | Completion date: November 25, 2014 | Expiration date: May 21, 2015 | Current use: Single family | Permit id: 14-36559-Mech | |||||
SCORE 93 Exterior/interior renovations in prep for painting as per hdlc 13-38699. Sheetrocking,siding,painting and trim. Permit type: Renovation (non-structural) | Permit status: Permit issued | Expiration date: March 23, 2014 | Current use: Single family | Permit id: 13-38703-Rnvn | |||||
SCORE 89 Electrical fire reconnect single-family dwelling jesse carr Date: May 20, 2002 Contractor: Jesse Carr Client: Akbar, Rasheed A | Permit id: E02003817 | |||||
Renovate 2-family dwelling as per plans. [2020-22] Date: June 29, 2015 Permit type: Hdlc coa | Permit status: Permit issued | Expiration date: January 9, 2016 | Current use: Two-family | Permit id: 15-19469-Hdlc | |||||
Install 3 ton ac and heating system, electric heat Date: April 4, 2016 Value: $3,000 Permit type: Mechanical hvac | Permit status: Permit issued | Expiration date: October 5, 2016 | Current use: Half of a party wall double | Permit id: 16-10755-Hvac | |||||
Non-structural renovations to existing two family dwelling - bathrooms, paint, kitchens, new cabinets, and install new flooring. No exterior work under this permit. Date: August 17, 2012 Value: $20,000 Permit type: Renovation (non-structural) | Permit status: Certificate of occupancy | Completion date: April 22, 2013 | Expiration date: February 17, 2013 | Current use: Two-family | Permit id: 12-22276-Rnvn | |||||
SCORE 96 Rewire 15-19469 rnvn Date: April 14, 2016 Contractor: Keith Alexander Davis Permit type: Electrical service / circuit / feeder | Permit status: Permit issued | Expiration date: October 14, 2016 | Current use: Two-family | Permit id: 16-12247-Serv | |||||
Work descripton: install solar panels as per hdlc c/a #hdlcp-12-0511. Historical import type: permits residential single (one-family unit) renovation (structural)user: rmaxwelltracking: 186131449382status: certificate issued w/meterstatus date: 6/6/2012 12:00: amowner: taylor avery sowner address: 20 barracks st, new orleans, la 70116owner edited by: 5/10/2012 by rmaxwell Date: June 9, 2012 Value: $24,000 Permit type: Renovation (structural) | Permit status: Inspection - completed | Expiration date: November 15, 2012 | Current use: Single family | Permit id: 12bld-02934 | |||||
Hdlc coa Date: August 17, 2012 Permit status: Permit issued | Expiration date: March 28, 2013 | Current use: Single family | Permit id: 12-22294-Hdlc | |||||
SCORE 98 Eletric wh kenneth6151407 ck1182 Date: September 7, 2016 Contractor: Kenneth Boissiere Permit type: Mechanical fuel gas | Permit status: Certificate of completion | Completion date: September 8, 2016 | Expiration date: March 7, 2017 | Current use: Unknown | Permit id: 16-29466-Fgas | |||||
Work descripton: install solar panels as per hdlc c a #hdlcp-12-0511. Historical import type: permits residential single (one-family unit) renovation (structural)user: rmaxwelltracking: 186131449382status: certificate issued w meterstatus date: 6 6 2012 12:00: amowner: taylor avery sowner address: 20 barracks st, new orleans, la 70116owner edited by: 5 10 2012 by rmaxwell Date: June 9, 2012 Value: $24,000 Permit type: Renovation (structural) | Permit status: Inspection - completed | Expiration date: November 15, 2012 | Current use: Single family | Permit id: 12bld-02934 | |||||
SCORE 79 Work descripton: solar panels- 12bld-02934historical import type: permits electrical residential service-circuits-feedersuser: dmfoleytracking: 86136178389status: permit issuance activestatus date: 5/14/2012 12:00: amowner: taylor avery sowner address: 20 barracks st, new orleans, la 70116owner edited by: 5/14/2012 by dmfoley Date: May 14, 2012 Contractor: M And M Repair Elect Permit type: Electrical service / circuit / feeder | Permit status: Permit issuance - active | Expiration date: November 14, 2012 | Current use: Unknown | Permit id: 12elc-05381 | |||||
SCORE 86 General repairs restaurant 49 and under nick ciaccio Date: August 23, 2002 Contractor: Nick Ciaccio Client: Burrito, Nouveau | Permit id: E02006666 | |||||
SCORE 86 Electrical emergency reconn - after hrs. Single-family dwelling replace meter pan Date: November 25, 2002 Contractor: Nick Ciaccio Client: Burrito, Nouveau | Permit id: E02009054 |