I plan to build a 16 by 24 deck off of the back of my house. I came down to the permitting office, and consulted with alan michaelson and jan ukena, to ensure that the project will comply with zoning and city specifications. The building area will have greater than 4 of clearance from all property lines. The final height of the deck above grade will be 1-2. The foundation will consist of 12 ea 8" diameter concrete piers spaced 8 apart. The piers will have stirrups in them for pressure treated 4"x4" lumber to attach to. I will then run double pressure treated 2"x10" lumber along the piers perpendicular to the house. On top of the 2"x10" lumber, i will span pressure treated 2"x6" lumber on 16" centers. The finished layer will be composite veranda decking that will be installed per the attached veranda specifications. I plan to install concrete anchor bolts into the footing of my house for attachement of the 2"x10" lumber to the house. I have attached elevations, details, and a site plan Date: April 25, 2012 Permit type: Permit | Permit status: Pass | Completion date: August 22, 2012 | Current use: Residential | Permit id: Bld2012-02963 | |||||
SCORE 84 Install 6 plumbing fixtures & 1 water heater for remodel to sfd Date: January 27, 2010 Contractor: John Rhinehartrhinehart Residence Permit type: Plumbing | Permit status: Closed | Completion date: July 9, 2010 | Current use: Residential | Permit id: Bld2010-00417 | |||||
SCORE 84 Homeowner elec permit for remodel to sfd Date: January 27, 2010 Contractor: John Rhinehartrhinehart Residence Permit type: Electrical | Permit status: Closed | Completion date: July 9, 2010 | Current use: Residential | Permit id: Bld2010-00416 | |||||
SCORE 84 Install furnace & ac, to include all assoc ductwork & gas lines Date: January 27, 2010 Contractor: John Rhinehartrhinehart Residence Permit type: Mechanical | Permit status: Closed | Completion date: July 9, 2010 | Current use: Residential | Permit id: Bld2010-00418 | |||||
SCORE 84 Remodel to sfd, present condition of home: bare framing, elec removed, cabinets gone. Plumbing & ductwork is existing except for upper bathroom. Elec & plmb permits required. R-1-50 not hist or yc. Date: December 3, 2009 Contractor: John Rhinehartrhinehart Residence Permit type: Permit | Permit status: Closed | Completion date: July 9, 2010 | Current use: Residential | Permit id: Bld2009-07482 | |||||
SCORE 56 I plan to build a 16 by 24 deck off of the back of my house. I came down to the permitting office, and consulted with alan michaelson and jan ukena, to ensure that the project will comply with zoning and city specifications. The building area will have greater than 4 of clearance from all property lines. The final height of the deck above grade will be 1-2. The foundation will consist of 12 ea 8" diameter concrete piers spaced 8 apart. The piers will have stirrups in them for pressure treated 4"x4" lumber to attach to. I will then run double pressure treated 2"x10" lumber along the piers perpendicular to the house. On top of the 2"x10" lumber, i will span pressure treated 2"x6" lumber on 16" centers. The finished layer will be composite veranda decking that will be installed per the attached veranda specifications. I plan to install concrete anchor bolts into the footing of my house for attachement of the 2"x10" lumber to the house. I have attached elevations, details, and a site plan Date: April 25, 2012 Permit status: Closed | Completion date: August 22, 2012 | Current use: Residential | Permit id: Bld2012-02963 | |||||
SCORE 84 Remodel to sfd, present condition of home: bare framing, elec removed, cabinets gone. Plumbing & ductwork is existing except for upper bathroom. Elec & plmb permits required. R-1-50 not hist or yc. Date: December 3, 2009 Contractor: John Rhinehartrhinehart Residence Permit status: Closed | Completion date: July 9, 2010 | Current use: Residential | Permit id: Bld2009-07482 | |||||
SCORE 84 Homeowner elec permit for remodel to sfd Date: January 27, 2010 Contractor: John Rhinehartrhinehart Residence Permit type: Electrical | Permit status: Closed | Completion date: July 9, 2010 | Current use: Residential | Permit id: Bld2010-00416 | |||||
SCORE 84 Install 6 plumbing fixtures & 1 water heater for remodel to sfd Date: January 27, 2010 Contractor: John Rhinehartrhinehart Residence Permit type: Plumbing | Permit status: Closed | Completion date: July 9, 2010 | Current use: Residential | Permit id: Bld2010-00417 | |||||
SCORE 84 Install furnace & ac, to include all assoc ductwork & gas lines Date: January 27, 2010 Contractor: John Rhinehartrhinehart Residence Permit type: Mechanical | Permit status: Closed | Completion date: July 9, 2010 | Current use: Residential | Permit id: Bld2010-00418 | |||||
SCORE 59 I plan to build a 16 by 24 deck off of the back of my house. I came down to the permitting office, and consulted with alan michaelson and jan ukena, to ensure that the project will comply with zoning and city specifications. The building area will have greater than 4 of clearance from all property lines. The final height of the deck above grade will be 1-2. The foundation will consist of 12 ea 8" diameter concrete piers spaced 8 apart. The piers will have stirrups in them for pressure treated 4"x4" lumber to attach to. I will then run double pressure treated 2"x10" lumber along the piers perpendicular to the house. On top of the 2"x10" lumber, i will span pressure treated 2"x6" lumber on 16" centers. The finished layer will be composite veranda decking that will be installed per the attached veranda specifications. I plan to install concrete anchor bolts into the footing of my house for attachement of the 2"x10" lumber to the house. I have attached elevations, details, and a site plan Date: April 25, 2012 Permit status: Closed | Completion date: August 22, 2012 | Current use: Residential | Permit id: Bld2012-02963 |