Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Repair termite damage on interior. As per applicant, all exterior work will be applied for under seperate permit. See contract submitted. Date: September 9, 2016 Permit type: Hdlc coa | Permit status: Permit not required | Completion date: September 15, 2016 | Current use: Single family | Permit id: 16-29796-Hdlc | |||||
SCORE 96 Interior exploratory demolition for termite damage. As per applicant, all exterior work will be applied for under seperate permit. See contract submitted. Permit type: Interior demolition | Permit status: Permit issued | Expiration date: March 16, 2017 | Current use: Single family | Permit id: 16-29796-Rnvn | |||||
SCORE 96 Permit allow for the placement of a dumpster in the parking lane in front of 1521 camp street. Date: September 16, 2016 Contractor: Charles T Sr Anderson Permit type: Dumpster/construction zone | Permit status: Certificate of completion | Completion date: November 16, 2016 | Expiration date: March 16, 2017 | Current use: Single family | Permit id: 16-30393-Rczd | |||||
SCORE 96 Pool wiring 17-17172-pool Date: May 23, 2017 Contractor: Charles Thurber Pierson Permit type: Electrical repair / replacement / addition | Permit status: Permit issued | Expiration date: November 23, 2017 | Current use: Single family | Permit id: 17-18177-Erpr | |||||
SCORE 96 Install in-ground swimming pool as per drawing. Permit type: Swimming pool | Permit status: Application submitted | Current use: Single family | Permit id: 17-12023-Pool | |||||
SCORE 93 Install recess cans; relocate existing wiring to new receptacle switch locations as needed:install new single meter pan 17-12021-rnvn Date: September 11, 2017 Contractor: Herbert Willie Hartman Iii Permit type: Electrical service / circuit / feeder | Permit status: Permit issued | Expiration date: March 11, 2018 | Current use: Single family | Permit id: 17-31032-Serv | |||||
SCORE 96 This is for a go mini storage unit for 1521 camp place. We have existing permit for renovation there. Permit #17-12021-rnvn, for at least one month. All plans and drawings already submitted. Date: November 13, 2017 Contractor: Charles T Sr Anderson Permit type: Dumpster/construction zone | Permit status: Application submitted | Current use: Single family | Permit id: 17-38725-Rczd | |||||
Repainting exterior sanding with containment Date: November 14, 2017 Permit type: Lead-based paint form | Permit status: Permit issued | Expiration date: May 14, 2018 | Current use: Business use | Permit id: 17-39036-Lead | |||||
SCORE 96 Trash Date: August 2, 2017 Contractor: Charles T Sr Anderson Permit type: Dumpster/construction zone | Permit status: Permit issued | Expiration date: February 2, 2018 | Current use: Single family | Permit id: 17-26641-Rczd | |||||
SCORE 93 Installing new 125 amp and circuits subpanel on new building behind main house. Panel will be fed from existing front of main house service 17-12015-accs Date: May 5, 2017 Contractor: Herbert Willie Hartman Iii Permit type: Electrical service / circuit / feeder | Permit status: Permit issued | Expiration date: November 5, 2017 | Current use: Single family | Permit id: 17-15752-Serv | |||||
New storage building Date: April 10, 2017 Permit type: Hdlc coa | Permit status: Permit not required | Completion date: April 19, 2017 | Expiration date: October 19, 2017 | Current use: Single family | Permit id: 17-12015-Hdlc | |||||
Renovate kitchen, sand floors, build closets, ext. And int. Renovate staircase, interior and exterior painting, add new lighting. Date: April 10, 2017 Permit type: Hdlc coa | Permit status: Permit issued | Expiration date: October 19, 2017 | Current use: Single family | Permit id: 17-12021-Hdlc | |||||
Swimming pool Date: April 10, 2017 Permit type: Hdlc coa | Permit status: Permit not required | Completion date: April 19, 2017 | Expiration date: October 19, 2017 | Current use: Single family | Permit id: 17-12023-Hdlc | |||||
SCORE 59 Renovate 2-story single-family dwelling as per plans. Permit type: Renovation (non-structural) | Permit status: Permit issued | Expiration date: November 2, 2017 | Current use: Single family | Permit id: 17-12021-Rnvn | |||||
SCORE 59 Construct accessory structure as per drawing. Permit type: Accessory structure | Permit status: Permit issued | Expiration date: November 1, 2017 | Current use: Single family | Permit id: 17-12015-Accs | |||||
Install gas line gas generator and meter increase. Date: August 16, 2017 Value: $500 Permit type: Mechanical fuel gas | Permit status: Certificate of completion | Completion date: November 6, 2017 | Expiration date: February 16, 2018 | Current use: Single family | Permit id: 17-28226-Fgas | |||||
Install inground swimming pool as per sketch and the new orleans comprehensive zoning ordinance article 21 section 21. 6. Ee. Date: May 16, 2017 Permit type: Hdlc coa | Permit status: Permit not required | Completion date: May 16, 2017 | Expiration date: November 16, 2017 | Current use: Single family | Permit id: 17-17172-Hdlc | |||||
SCORE 96 Install inground swimming pool as per sketch and the new orleans comprehensive zoning ordinance article 21 section 21. 6. Ee. Permit type: Swimming pool | Permit status: Permit issued | Expiration date: November 16, 2017 | Current use: Single family | Permit id: 17-17172-Pool | |||||
SCORE 99 Replace 3 split central heating and cooling systems3. 5 ton, 3. 5 ton, and 2 ton Permit type: Mechanical hvac | Permit status: Permit issued | Expiration date: March 25, 2018 | Current use: Single family | Permit id: 17-32222-Hvac |