Building Permits at 1212 Royal St, New Orleans, LA 70116


Estimated Price

Beds

Baths

Rooms

Sq.Ft.

Built:   Lot size:   Taxed:
RENOVATION HISTORY
Based on the information received from building department, associated with 1212 Royal St, New Orleans, LA 70116 over the past .

If you are considering hiring for your home renovation project, we recommend using our bidding system to get competitive quotes.

ACTIVITY



PERMITS VALUATION



RENOVATIONS
Find out the best time of the year to complete your project on a minimal budget.
Get several free quotes from best contractors in your area.

REQUEST A QUOTE
Explore CheckPermit
Our dataset includes 30 milion building permits across 4 million addresses in US.

We analyzed and ranked over 1 million home remodeling contractors based on official government sources.

Every contractor's rank is calculated based on official government records.
RECENT PROJECTS


Content Date Cost Contractor Rank Address Contractor
SCORE
56
Projecting sign restaurant people and over sign fee 2000pd
Date:  April 18, 2000

Client: Aydin, Fatima | Permit id: S00000543
2000/04/180561212 Royal St, New Orleans, La 70116Mona Lisa Aydin Inc
SCORE
74
Projecting sign restaurant people and over sign fee 2001 paid
Date:  April 2, 2001
Contractor: Mona Lisa

Client: Aydin, Fatima | Permit id: S01000454
2001/04/020741212 Royal St, New Orleans, La 70116Mona Lisa
SCORE
74
Projecting sign restaurant people and over sign fee
Date:  March 6, 2002
Contractor: Mona Lisa

Client: Aydin, Fatima | Permit id: S02000450
2002/03/060741212 Royal St, New Orleans, La 70116Mona Lisa
SCORE
74
Projecting sign restaurant people and over sign fee 2003 paid for 1
Date:  March 17, 2003
Contractor: Mona Lisa

Client: Aydin, Fatima | Permit id: S03000466
2003/03/170741212 Royal St, New Orleans, La 70116Mona Lisa
SCORE
74
Projecting sign restaurant people and over sign fee 2004 paid for 1
Date:  February 4, 2004
Contractor: Mona Lisa

Client: Aydin, Fatima | Permit id: S04000271
2004/02/040741212 Royal St, New Orleans, La 70116Mona Lisa
Repair stucco finish above second story window, second from the barracks property line using vcc approved stucco formulamortar: no more than 1 part portland cement, 3 parts lime, 9 parts sand, and enough water to form a workable mix. Prepackaged mixes are not permitted, as quality control is not consistent.
Date:  November 11, 2014

Permit type: Vcc general work | Permit status: Permit issued | Expiration date: May 18, 2015 | Current use: Mixed use | Permit id: 14-35099-Vcgen
2014/11/110951212 Royal St, New Orleans, La 70116
To remove broken glass from a total of three (3) window lites. To install three (3) new panes of glass to replace broken glass. Glass to be 1/8 thick and clear. Windows to be glazed using glazing putty, once skin has formed on glazing, glazing to be primed with oil based primer and painted white to match existing.
Date:  May 31, 2016

Permit type: Vcc general work | Permit status: Permit issued | Expiration date: November 30, 2016 | Current use: Mixed use | Permit id: 16-17655-Vcgen
2016/05/310951212 Royal St, New Orleans, La 70116
Repair brick and stucco at second window. See attached.
Date:  November 11, 2014
Value:   $1,800

Permit type: Renovation (non-structural) | Permit status: Permit approved | Current use: Mixed use | Permit id: 14-35099-Rnvn
2014/11/111800951212 Royal St, New Orleans, La 70116
Repair 3 broken window panes.
Date:  May 26, 2016
Value:   $75

Permit type: Renovation (non-structural) | Permit status: Permit approved | Current use: Mixed use | Permit id: 16-17655-Rnvn
2016/05/2675951212 Royal St, New Orleans, La 70116
Stabilize second floor brick header, cornice and parapet by installing temporary pressure treated wood lintel and bricks within missing lintel space (lintel removed without benefit of vcc review or approval), at middle window of left, barracks-side bay. Perform minor exploratory demolition at second floor lintel/header of right window of right, gov. Nicholls-side bay, evaluating extent of damage and possible lintel failure. Petitioner to submit application for structural renovation within days for final architectural committee review and approval. Application to include full scope of work, corresponding engineers report and detailed wall sections all repair/replacement work shall match existing in color, size, material, detail, profile and exposure
Date:  May 16, 2016

Permit type: Vcc general work | Permit status: Vcc arc meeting | Expiration date: November 16, 2016 | Current use: Half of a party wall double | Permit id: 16-16282-Vcgen
2016/05/160951212 Royal St, New Orleans, La 70116
Remove deteriorated balcony floor boards,install new 5/4x4 t&g floor boards, per vcc standard detail sheet no. 12 (attached). Prime & paint deck boards prior to installation, paint deck boards with additional coat of gray on top and sides, and paint underside white to match stringers and outriggers, after installation. All repair/replacement work shall match existing in color, size, material, detail, profile and exposure
Date:  March 24, 2016

Permit type: Vcc general work | Permit status: Permit issued | Expiration date: September 24, 2016 | Current use: Mixed use | Permit id: 16-08006-Vcgen
2016/03/240951212 Royal St, New Orleans, La 70116
SCORE
56
Projecting sign restaurant people and over sign fee 2000pd
Date:  April 18, 2000

Client: Aydin, Fatima | Permit id: S00000543
2000/04/180561212 Royal St, New Orleans, La 70116Mona Lisa Aydin, Inc
Stabilize second floor brick header, cornice and parapet by installing temporary pressure treated wood lintel and bricks within missing lintel space (lintel removed without benefit of vcc review or approval), at middle window of left, barracks-side bay. Perform minor exploratory demolition at second floor lintel header of right window of right, gov. Nicholls-side bay, evaluating extent of damage and possible lintel failure. Petitioner to submit application for structural renovation within days for final architectural committee review and approval. Application to include full scope of work, corresponding engineers report and detailed wall sections all repair replacement work shall match existing in color, size, material, detail, profile and exposure
Date:  May 16, 2016

Permit type: Vcc general work | Permit status: Vcc arc meeting | Expiration date: November 16, 2016 | Current use: Half of a party wall double | Permit id: 16-16282-Vcgen
2016/05/160951212 Royal St, New Orleans, La 70116
Remove deteriorated balcony floor boards,install new 5 4x4 t&g floor boards, per vcc standard detail sheet no. 12 (attached). Prime & paint deck boards prior to installation, paint deck boards with additional coat of gray on top and sides, and paint underside white to match stringers and outriggers, after installation. All repair replacement work shall match existing in color, size, material, detail, profile and exposure
Date:  March 24, 2016

Permit type: Vcc general work | Permit status: Permit issued | Expiration date: September 24, 2016 | Current use: Mixed use | Permit id: 16-08006-Vcgen
2016/03/240951212 Royal St, New Orleans, La 70116
To remove broken glass from a total of three (3) window lites. To install three (3) new panes of glass to replace broken glass. Glass to be 1 8 thick and clear. Windows to be glazed using glazing putty, once skin has formed on glazing, glazing to be primed with oil based primer and painted white to match existing.
Date:  May 31, 2016

Permit type: Vcc general work | Permit status: Permit issued | Expiration date: November 30, 2016 | Current use: Mixed use | Permit id: 16-17655-Vcgen
2016/05/310951212 Royal St, New Orleans, La 70116
SCORE
60
Remove 5/4 x 3 tongue& groove (t&g) deck boards (4 x 48 area) and replace with new 5/4 x 3 t&g deck boards at second floor balcony. All new boards will be primed and painted prior to installation. Benjamin moore platinum gray deck paint
Date:  March 11, 2016

Permit type: Renovation (non-structural) | Permit status: Application submitted | Current use: Mixed use | Permit id: 16-08006-Rnvn
2016/03/110601212 Royal St, New Orleans, La 70116Clarence T Jr Coleman
To perform masonry, header, and balcony work as per materials stamped vcc approved 09 15 17. Work includes but is not necessarily limited to:replacing the header above second floor door on the royal st. Elevation, closest to the governor nicholls property line, with new 6x6 headerpainting headers to match existing conditionswhite, semiglossrepointing masonry above second floor door on the royal st. Elevation, second opening from the barracks property line, utilizing the vcc standard detail sheet (attached)repairing replacing stucco above both repaired replaced headers utilizing the vcc standard detail sheet (attached)remove existing balcony deck boards and stringersinstall new 3x4 beaded stringers and new 5 4 x 4 t&g deck boards as per vcc standard detail sheet no. 12 (attached)paint deck boards and associated components... Underside of balcony fascia sleeperswhite, semigloss tops and sides of deckboardsgrey, semiglossremove window ac unit from transom on the royal st. Elevation and re
Date:  August 30, 2017

Permit type: Vcc general work | Permit status: Permit issued | Expiration date: March 15, 2018 | Current use: Half of a party wall double | Permit id: 17-29795-Vcgen
2017/08/300951212 Royal St, New Orleans, La 70116
Shutters and doors: sw ivay wall (to match existing), semiglosswindows and trim: white satin ppu18-08, semiglosswalls: gray, (see attached for exact formula specificaitons), flat or eggshell
Date:  August 30, 2017

Permit type: Vcc paint | Permit status: Permit issued | Expiration date: April 5, 2018 | Current use: Mixed use | Permit id: 17-17825-Vcpnt
2017/08/300951212 Royal St, New Orleans, La 70116