Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
SCORE 97 Re-roof (commercial) hotel reroof existing hotel as per vcc #020425 install new "spray foam" roofing system over existing flat roof. Date: June 7, 2002 Contractor: James Mcdonald Client: Dupuy, Maison | Permit id: B02002684 | |||||
SCORE 60 Projecting sign hotel sign fee 2001 paid Date: May 2, 2001 Contractor: Thi Fq L. P Client: Dupuy, Maison | Permit id: S01000755 | |||||
SCORE 56 Projecting sign hotel sign fee Date: March 27, 2002 Contractor: Thi Fq L.P Client: Dupuy, Maison | Permit id: S02000620 | |||||
SCORE 56 Projecting sign hotel sign fee 2003 paid for 1 Date: March 27, 2003 Contractor: Thi Fo L. P Client: Dupuy, Maison | Permit id: S03000680 | |||||
SCORE 60 Projecting sign hotel sign fee 2004 Date: May 12, 2004 Contractor: Thi Fq L. P Client: Dupuy, Maison | Permit id: S04000954 | |||||
SCORE 96 Selective demolition of exterior facade at masion dupuy hotel as per vcc permit # 14-36916-vcgen. Permit type: Renovation (non-structural) | Permit status: Permit issued | Expiration date: June 3, 2015 | Current use: Business use | Permit id: 14-37217-Rnvn | |||||
Removal of additional trash and unused equipment Date: June 17, 2016 Permit type: Dumpster/construction zone | Permit status: Permit issued | Expiration date: December 22, 2016 | Current use: Business use | Permit id: 16-20098-Rczd | |||||
All work to be completed per drawings submitted 10/02/15 and stamped vcc approved 10/14/15 as follows:remove deteriorated millwork and service entrance doors within burgundy-side, 11-9" cased opening,relocate air intake and exhaust fans as indicated,install single 4-11" wide wooden door with 6" tongue and groove boards, designed to resemble double doors, with metal strap hinges (painted to match adjacent surface) on left, toulouse street side of opening,install fixed 4-11" wooden infill panels on right side of opening, designed to match doors on left. Install wooden framing and louvered panels above doors and infill. Paint new millwork dark green, semigloss, to match existing. Date: August 27, 2015 Permit type: Vcc general work | Permit status: Permit issued | Expiration date: March 25, 2016 | Current use: Business use | Permit id: 15-24513-Vcgen | |||||
Exterior repairs including:repairs to concrete courtyard base beneath brick paversinstallation of new downspouts to match existing, to be tied in with subsurface drainage systemrepairs to existing wood windows and doors; sand, clean, prep and paint to match existing; reglaze existing lass lites with new glazing puttyclean existing brick masonry walls, tuckpoint mortar joints and provide sealant at joints between different materials and thru-wall penetrationspoint any gaps in existing sloped mortar above projecting brick masonryclean and repair existing stucco plaster finish using stucco of matching compositionapply water repellant on existing, 20th century, hard fired bricks onlyrepair existing slate roof, provide new felt underlayment and self-adhereing ice and water shield membrane at mansard roof perimeter and permeter of dormers, provide new copper valley flashings around dormers and at sidewall and parapet conditions, hang new gutter sectionspaint existing iron railings blackrepai Date: February 10, 2015 Permit type: Vcc general work | Permit status: Permit expired due to ina | Completion date: April 5, 2016 | Expiration date: September 16, 2015 | Current use: Business use | Permit id: 15-04334-Vcgen | |||||
SCORE 59 Re-roofing, waterproofing, coating/painting, and window refurbishment/painting. Drainage work related to tying in new downspouts to subsurface drainage. Area affected is roof area of approx. 30,500sf and waterproofing/coating (wall area) is 72,000sf Permit type: Renovation (non-structural) | Permit status: Permit issued | Expiration date: September 19, 2015 | Current use: Business use | Permit id: 15-04334-Rnvn | |||||
SCORE 98 New circuits for courtyard 15-11148-rnvn Date: July 30, 2015 Contractor: William Appel Permit type: Electrical repair / replacement / addition | Permit status: Permit issued | Expiration date: January 30, 2016 | Current use: Business use | Permit id: 15-22803-Erpr | |||||
SCORE 59 Renovation of the existing courtyard, pool deck and porte cochere of the maison dupuy hotel as per plans and vcc (15-11552-vcge) Date: April 14, 2015 Value: $1,362,498 Permit type: Renovation (non-structural) | Permit status: Certificate of occupancy | Completion date: September 17, 2015 | Expiration date: January 8, 2016 | Current use: Business use | Permit id: 15-11148-Rnvn | |||||
Replace light fixtures under balcony Date: November 28, 2016 Value: $500 Permit type: Renovation (non-structural) | Permit status: Permit approved | Current use: Business use | Permit id: 16-39044-Rnvn | |||||
See vcc permit 16-39060 Date: November 28, 2016 Permit type: Vcc general work | Permit status: Voided - duplicate permit | Completion date: November 28, 2016 | Current use: Business use | Permit id: 16-39044-Vcgen | |||||
SCORE 59 Renovation of the existing courtyard, pool deck and porte cochere of the maison dupuy hotel as per plans and vcc (15-11552-vcge) Date: April 14, 2015 Value: $1,362,498 Permit type: Renovation (non-structural) | Permit status: Certificate of occupancy | Completion date: September 17, 2015 | Expiration date: January 8, 2016 | Current use: Business use | Permit id: 15-11148-Rnvn | |||||
Replace existing unshielded light fixtures with new can fixtures. 1. 13. 17 keith roberts called said they are still waiting on the delivery of new fixtures and will be installing as soon as possible Date: November 28, 2016 Permit type: Vcc general work | Permit status: Permit issued | Expiration date: May 28, 2017 | Current use: Business use | Permit id: 16-39060-Vcgen | |||||
SCORE 59 Re-roofing, waterproofing, coating painting, and window refurbishment painting. Drainage work related to tying in new downspouts to subsurface drainage. Area affected is roof area of approx. 30,500sf and waterproofing coating (wall area) is 72,000sf Permit type: Renovation (non-structural) | Permit status: Permit issued | Expiration date: September 19, 2015 | Current use: Business use | Permit id: 15-04334-Rnvn | |||||
All work to be completed per drawings submitted 10 02 15 and stamped vcc approved 10 14 15 as follows:remove deteriorated millwork and service entrance doors within burgundy-side, 11-9" cased opening,relocate air intake and exhaust fans as indicated,install single 4-11" wide wooden door with 6" tongue and groove boards, designed to resemble double doors, with metal strap hinges (painted to match adjacent surface) on left, toulouse street side of opening,install fixed 4-11" wooden infill panels on right side of opening, designed to match doors on left. Install wooden framing and louvered panels above doors and infill. Paint new millwork dark green, semigloss, to match existing. Date: August 27, 2015 Permit type: Vcc general work | Permit status: Permit issued | Expiration date: March 25, 2016 | Current use: Business use | Permit id: 15-24513-Vcgen | |||||
SCORE 96 All work to be completed per drawings submitted 10/02/15 and stamped vcc approved 10/14/15 as follows:remove deteriorated millwork and service entrance doors within burgundy-side, 11-9" cased opening,relocate air intake and exhaust fans as indicated,install single 4-11" wide wooden door with 6" tongue and groove boards, designed to resemble double doors, with metal strap hinges (painted to match adjacent surface) on left, toulouse street side of opening,install fixed 4-11" wooden infill panels on right side of opening, designed to match doors on left. Install wooden framing and louvered panels above doors and infill. Paint new millwork dark green, semigloss, to match existing. Permit type: Renovation (non-structural) | Permit status: Permit approved | Current use: Business use | Permit id: 15-24513-Rnvn |