Content |
---|
SCORE 92 22 W Firth St Philadelphia Pa 191324122 Replace 1 amp service, replace 8 switches, replace 11 outlets, install 3 dedicated lines using wiremold, replace 2 light fixtures replace gfci, install lines for washer and dryers amp as per nec 2008 east district no bldg permit on file ![]() ![]() Client: West Colby | Permit type: Electrical permit | Permit status: Active | Completion date: December 5, 2017 | Permit id: 836872 |
SCORE 92 29 N 25th St Philadelphia Pa 191321903 Install 100amp service & wiremold 3 dedicated lines, replace switches and outlets & wire gas meter and water heater as per nec 2008 north district no bldg permit on file ![]() ![]() Client: James Barnwell Pauline | Permit type: Electrical permit | Permit status: Active | Completion date: December 1, 2017 | Permit id: 836192 |
SCORE 92 61 Osage Ave Philadelphia Pa 191431008 Install 100amp service & wiremold 3 dedicated lines replace 5 switches & 2 gfci outlets as per nec 2008 west district (no bldg permit on file) ![]() ![]() Client: Assell Derrick | Permit type: Electrical permit | Permit status: Active | Completion date: December 1, 2017 | Permit id: 836197 |
SCORE 92 4141 Parrish St Philadelphia Pa 191044832 Installing 6-smokes,6-co detectors,4-recepts and 12-high hats on an existing 100amp service as per 2008 nec (west district) ![]() ![]() Client: J Money Enterprises Llc | Permit type: Electrical permit | Permit status: Active | Completion date: December 6, 2017 | Permit id: 835262 |
SCORE 92 1746 N Dover St Philadelphia Pa 191212710 Install 100amp service with grounding and bonding and replacing switches,outlets and 2-dedicated lines as per 2008 nec (north district) ![]() ![]() Client: Harris Nathaniel L Carroll Cecelia | Permit type: Electrical permit | Permit status: Active | Completion date: November 14, 2017 | Permit id: 831960 |
SCORE 92 419 Cross St Philadelphia Pa 191476510 Install 100amp service with grounding and bonding and replacing switches,outlets and 2-dedicated lines as per 2008 nec (south district) ![]() ![]() Client: Smallwood Thomas L Jr | Permit type: Electrical permit | Permit status: Active | Completion date: November 14, 2017 | Permit id: 831966 |
SCORE 92 208 Belgrade St Philadelphia Pa 191254402 Rewire building with switches,outlets,lights,fixtures,smokes and co detectors on an existing 200amp service as per 2008 nec (east district) ![]() ![]() Client: Solliday Colt | Permit type: Electrical permit | Permit status: Active | Completion date: November 14, 2017 | Permit id: 831967 |
SCORE 92 78 Temple Rd Philadelphia Pa 191502110 Install 110amp panel install grounding and bonding replace 4 switches replace 4 outlets as per 2008 nec. ![]() ![]() Client: Cann Patricia Ann | Permit type: Electrical permit | Permit status: Active | Completion date: November 3, 2017 | Permit id: 829546 |
SCORE 92 1754 S 65th St Philadelphia Pa 191421324 Replace 100amp panel grounding and bonding install carbon smoke detector replace outlets install dedicated line in basement as per 2008 nec. ![]() ![]() Client: Avis Charlene | Permit type: Electrical permit | Permit status: Active | Completion date: November 3, 2017 | Permit id: 829540 |
SCORE 92 911 Longshore Ave Philadelphia Pa 191114424 Install 110amp service per code install smoke carbon in basement replace switches and outlets as per 2008 nec. ![]() ![]() Client: Amill Evelyn Fred | Permit type: Electrical permit | Permit status: Active | Completion date: November 3, 2017 | Permit id: 829542 |