Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
SCORE 66 112 Stratford Rd, Asheville, Nc 28804 Deck addition; new deck; front setbacks to be measured from the existing right of way line. Side and rear setbacks are to be measured from property lines. Setbacks also apply to porches, decks, etc.; 5/4/00: left phone message for builder to call. Deck has excessive cantilevers for beams and the floor joists. Changing the plans will impact the beam sizes, joist sizes, and maybe the footing sizes. Redesign is needed.; building comments permit approved with changes to submitted plans. Refer to redlined comments on the approved plans and the review comments attached to the plans. Reference the review comments re: floor joist cantilever limitation; dropped beam cantilever limitations; joist span limitation; and approved method of lateral bracing per volume vii, residential build- ing code. The approved plans and review comments shall be on the job site for the city building inspector. Call maro slaughter at redacted phone number to schedule inspection. Client: Barlas Deck Addition | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 00-02074 | Parcel: 25115 | |||||
SCORE 66 10 Columbine Rd, Asheville, Nc 28803 Vanderkwaak deck; front setbacks to be measured from the existing right of way line. Side and rear setbacks are to be measured from property lines. Setbacks also apply to porches, decks, etc.; building comments deck addition. Change floor joist spacing to 12" o. C. For a maximum clear span of 13-8" (#2 2x8 syp in wet service condition). Call steve schoch for building inspection at redacted phone number Client: Vanderkwaak Deck | Permit type: Res: accessory structure | Permit status: Closed | Current use: Residential | Permit id: 00-05017 | Parcel: 47274 | |||||
SCORE 66 7 Sunset Vw, Asheville, Nc 28804 Deck addition; setback requirements will not apply to the freestanding walkway from the street down the hill. Setbacks will apply to the bridge and deck to be added to existing the deck.; call maro slaughter at redacted phone number to schedule inspection. Building. See comments. Arbor and connecting stairs are not applicable for building inspection per section 103. 1. ; front setbacks to be measured from the existing right of way line. Side and rear setbacks are to be measured from property lines. Setbacks also apply to porches, decks, etc. Client: Wedel Deck Addition | Permit type: Res: addition | Permit status: Closed | Current use: Residential | Permit id: 00-02355 | Parcel: 28154 | |||||
SCORE 66 1056 Columbine Rd, Asheville, Nc 28803 Deck addition; front setbacks to be measured from the existing right of way line. Side and rear setbacks are to be measured from property lines. Setbacks also apply to porches, decks, etc.; call steve schoch for building inspection at redacted phone number building. See comments. Client: Zieber Deck Addition | Permit type: Res: addition | Permit status: Closed | Current use: Residential | Permit id: 00-02795 | Parcel: 47261 | |||||
SCORE 66 3 Glenview Rd, Asheville, Nc 28804 Residential deck for bailey residence;scc; setbacks along street right of ways must be measured from the street right of way line or the street, whichever is closest to the property. All other setbacks are to be measured from the property boundary lines. Setbacks also apply such items as porches, decks, patios, etc.; building safety comments see the accompanying review comments sheet and the notes on the construction plans for additional requirements and information. For building inspections call maro slaughter at redacted phone number. All subcontractors need to complete trade application for project. Subcontractors need to either visit the permit office or fax copy of application to (828)redacted phone number for activation of electrical, plumbing and mechanical permits. For electrical inspections call kelly sams at redacted phone number. For mechanical inspections call joe chennault at redacted phone number. For plumbing inspections call tim Client: Bailey Deck | Permit type: Res: accessory structure | Permit status: Closed | Current use: Residential | Permit id: 05-02607 | Parcel: 26851 |