Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
SCORE 89 1123 S 18th St Philadelphia Pa 191463050 Veneer brick front, use of existing foundation. 4 windows and 1 door-existing openings install 4 inch brick veneer on existing foundation in front of existing masonry wall as per 2009 irc 703. 7. Maximum height: feet above foundation. Maximum thickness 5 inches. New concrete footing to be below frost line, ( inches). New wall shall be anchored to supporting wall with corrosion-resistant metal ties 24 inches on center horizontally and vertically. Provide 1 inch air space between walls. Provide weep holes and flashing above window and door openings. Provide capping, flashing and caulking at termination of wall to prevent water infiltration. Date: June 26, 2015 Contractor: Tbc Llc Client: Ward Tonya D | Permit type: Alteration permit | Permit status: Completed | Completion date: September 15, 2015 | Permit id: 620737 | |||||
SCORE 89 1531 S 8th St Philadelphia Pa 191476401 Remove existing 2 story front masonry wall. Replace with new 8 inch masonry wall, (4" brick & 4" block) on existing foundation. Windows and door same location, shall comply with the 2009 international energy efficiency code, u factor of . 35, and shall comply with emergency egress standards as per irc. New door opening for 36 inch door. Horizontal reinforcement (durawall) every 24 inches. Install returns into party walls for structural connection. Flash and seal roof to new front. Install 2 x 4 frame wall, r-19 insulation and sheetrock on interior front wall for finish. No other work allowed under this permit. An inspection of existing wall to be scheduled with inspector before work starts. Date: September 22, 2015 Contractor: Tbc Llc Client: Termini Vincent A Sr Tr Termini Barbara R Tr | Permit type: Alteration permit | Permit status: Completed | Completion date: February 29, 2016 | Permit id: 640651 | |||||
SCORE 89 425 Greenwich St Philadelphia Pa 191476522 Interior alterations to include drywall throughout, moisture resistant drywall in the bathroom and kitchen, new windows and doors in existing opening. Applicant agrees to limit the construction to comply with ez permit standard for interior alterations, dated january 2011. Deviation from the standard will result in revocation of this permit and imposition of further penalties. Separate permits required for plumbing, electrical and mechanical work. Date: March 1, 2017 Contractor: Tbc Llc Permit type: Alteration permit | Permit status: Expired | Completion date: November 6, 2017 | Permit id: 762547 | |||||
SCORE 89 728 Fitzwater St Philadelphia Pa 191472815 Interior alterations to include drywall throughout, moisture resistant drywall in the bathroom and kitchen, new windows and doors in existing opening. Applicant agrees to limit the construction to comply with ez permit standard for interior alterations, dated january 2011. Deviation from the standard will result in revocation of this permit and imposition of further penalties. Separate permits required for plumbing, electrical and mechanical work Date: March 29, 2016 Contractor: Tbc Llc Client: Lynch Jeremy D Lynch Jennifer K | Permit type: Alteration permit | Permit status: Completed | Completion date: August 1, 2016 | Permit id: 679041 | |||||
SCORE 89 1327 S Ringgold St Philadelphia Pa 191464016 New 3rd floor addition with roof decks and pilot house on top existing 2 story sfd. Reconfiguration of 1st and 2nd floors with new 3rd floor addition Date: May 1, 2017 Contractor: Tbc Llc Client: Antage Real Estate Solut | Permit type: Addition permit | Permit status: Active | Completion date: October 25, 2017 | Permit id: 775793 | |||||
SCORE 89 244 Arch St Philadelphia Pa 191062204 Proposed new construction of a sfd as per plans see ap# 514863 for related documents Date: April 11, 2014 Contractor: Tbc Llc Permit type: New construction permit | Permit status: Completed | Completion date: January 19, 2016 | Permit id: 514874 | |||||
SCORE 89 1913 Kater St Philadelphia Pa 191461431 Construction of addition with roof deck and roof access structure to existing single family residence in accordance with sealed plans. Date: September 15, 2015 Contractor: Tbc Llc Client: Ash Nancy | Permit type: Addition permit | Permit status: Completed | Completion date: February 22, 2016 | Permit id: 630524 | |||||
SCORE 89 2 Greenwich St Philadelphia Pa 191476024 For the construction of a spread footing foundation system as per approved plans geotechnical report. Foundation only permit. Date: February 5, 2015 Contractor: Tbc Llc Client: Tartaglia Leah | Permit type: New construction permit | Permit status: Completed | Completion date: July 31, 2017 | Permit id: 574020 | |||||
SCORE 89 2 Greenwich St Philadelphia Pa 191476024 For the erection of a detached two story structure with a cellar, attic, roof deck and interior parking. Foundation previously approved - see a p no 574020. Structure for use as single family dwelling. Separate permits required for plumbing, mechanical and electrical. Date: July 29, 2015 Contractor: Tbc Llc Client: Tartaglia Leah | Permit type: New construction permit | Permit status: Active | Completion date: August 10, 2017 | Permit id: 621825 | |||||
SCORE 89 901 Mckean St Philadelphia Pa 191482326 Veneer brick front, use of existing foundation. 4 windows and 1 door-existing openings install 4 inch brick veneer on existing foundation in front of existing masonry wall as per 2009 irc 703. 7. Maximum height: feet above foundation. Maximum thickness 5 inches. New concrete footing to be below frost line, ( inches). New wall shall be anchored to supporting wall with corrosion-resistant metal ties 24 inches on center horizontally and vertically. Provide 1 inch air space between walls. Provide weep holes and flashing above window and door openings. Provide capping, flashing and caulking at termination of wall to prevent water infiltration. Date: June 26, 2015 Contractor: Tbc Llc Client: Edwards Douglas V Feuer-Edwards Ashley L | Permit type: Alteration permit | Permit status: Completed | Completion date: February 18, 2016 | Permit id: 620732 | |||||
SCORE 89 2407 Wharton St Philadelphia Pa 191464022 Administrative review ( original ap# 749027 ) ( cal# 29817) for the removal of roof deck and pilot house of previously approved attached structure for multi-family (3 units) household living. Size and location as shown in the application. Date: October 18, 2017 Contractor: Tbc Llc Client: Tete Brothers Llc | Permit type: Zoning admin review | Permit status: Completed | Completion date: October 18, 2017 | Permit id: 811772 | |||||
SCORE 89 172832 S 2nd St Philadelphia Pa 191481908 Amendment to application #772531 as per approved plans and per attached letter. Date: September 14, 2017 Contractor: Tbc Llc Permit type: Administrative permit | Permit status: Active | Completion date: November 8, 2017 | Permit id: 793310 | |||||
SCORE 89 172832 S 2nd St Philadelphia Pa 191481908 No removal of more than 2 3 of framing members. For the erection of a 3rd floor addition, roof deck access structure, elevator, open exit access stairway from roof deck to 3rd floor, complete change in use and occupancy classification with level iii interior alteration, and all other work as per approved plans. For a vacant two(2) commercial spaces at first floor in the same building with multi-family household living ( twelve(12) dwelling units - type b units - from 1st floor through third floors. Asbestos abatement required prior to commencement of work entire buildnig to be sprinklered per nfpa 13 separate permit required for any mep and fire suppression work. Date: May 30, 2017 Contractor: Tbc Llc Permit type: Addition permit | Permit status: Active | Completion date: September 13, 2017 | Permit id: 772531 | |||||
SCORE 89 2336 W Thompson St Philadelphia Pa 191214819 Ez alterations permit - for alterations to an existing one family dwelling as per attached standard. Deviations from this standard will result in permit revocation and require submission of construction plans. Work to include repairs to non-load bearing partition framing, repair gwb, tape and finish throughout, trim, insulation, kitchen & bathroom alterations, hardwood flooring, entry door, interior doors and windows. Separate permits required for plumbing, electric and hvac installations. Call inspector at least 24 hours prior to the start of work. Date: October 18, 2017 Contractor: Tbc Llc Client: Brown Deborah A Brown Vanessa | Permit type: Alteration permit | Permit status: Active | Completion date: October 25, 2017 | Permit id: 825046 | |||||
SCORE 89 12 Titan St Philadelphia Pa 191474508 Interior alterations to include drywall throughout, moisture resistant drywall in the bathroom and kitchen, new windows and doors in existing opening. Applicant agrees to limit the construction to comply with ez permit standard for interior alterations, dated january 2011. Deviation from the standard will result in revocation of this permit and imposition of further penalties. Separate permits required for plumbing, electrical and mechanical work Date: February 23, 2016 Contractor: Tbc Llc Client: Kurtz Dan Bloemer Audrey | Permit type: Alteration permit | Permit status: Completed | Completion date: November 17, 2016 | Permit id: 671822 | |||||
SCORE 89 172832 S 2nd St Philadelphia Pa 191481908 Amendment to permit #772531 to increase the fire resistance rating of the horizontal and vertical wall and floor assemblies between the residential and commercial space to two (2) hour fire resistance rated construction. This permit to also document that the building is permitted to be sprinklered per nfpa 13 and nfpa 13r. Date: September 14, 2017 Contractor: Tbc Llc Permit type: Administrative permit | Permit status: Active | Completion date: October 20, 2017 | Permit id: 809410 | |||||
SCORE 89 1647 N 2nd St Philadelphia Pa 191223114 Ez interior demolition- for the interior demolition of non load-bearing partition walls and ceilings as per attached standard. Deviations from this standard will result in permit revocation and require submission of construction plans. Date: May 12, 2017 Contractor: Tbc Llc Client: Ftc 1647 N 2nd Llc | Permit type: Demolition permit | Permit status: Active | Completion date: November 27, 2017 | Permit id: 783170 | |||||
SCORE 89 2302 Waverly St Philadelphia Pa 191461124 Selective interior demo, non stural interior framing on rear of first floor and second floor. Date: November 1, 2017 Contractor: Tbc Llc Client: Gallagher Thomas J Loesing Jessica E | Permit type: Alteration permit | Permit status: Active | Completion date: November 22, 2017 | Permit id: 828872 | |||||
SCORE 89 2225 Sears St Philadelphia Pa 191464226 Interior alterations to include drywall, sheet rock,bathroom and kitchen, new windows and doors in existing opening. Applicant agrees to limit the construction to comply with ez permit standard for interior alterations, dated january 2011. Deviation from the standard will result in revocation of this permit and imposition of further penalties. Separate permits required for plumbing, electrical and mechanical work.. Note: contractor is listed as a "sole proprietor" and has no employees and or workers compensation insurance - all subcontractors require separate licenses and insurance Date: November 22, 2017 Contractor: Tbc Llc Client: Reed Samuel | Permit type: Alteration permit | Permit status: Active | Completion date: November 22, 2017 | Permit id: 833617 | |||||
SCORE 89 2616 Sears St Philadelphia Pa 191463833 For the repair of an existing structure, work included widening of stairs, replace front and rear wall with masonry and brick, new doors windows and lintels,reconstruction of rear bay in kind. Seperate permit required for interior renovation fit-out and electrical, mechanical and plumbing. No other work included in this permit application. Details as shown on the plan. Date: October 25, 2017 Contractor: Tbc Llc Client: Tete Brothers Llc | Permit type: Alteration permit | Permit status: Active | Completion date: October 26, 2017 | Permit id: 813322 | |||||
SCORE 89 2136 Wharton St Philadelphia Pa 191464537 Interior alterations to include drywall throughout, moisture resistant drywall in the bathroom and kitchen, new windows and doors in existing opening. Applicant agrees to limit the construction to comply with ez permit standard for interior alterations, dated january 2011. Deviation from the standard will result in revocation of this permit and imposition of further penalties. Separate permits required for plumbing, electrical and mechanical work Date: January 12, 2017 Contractor: Tbc Llc Client: Wiener Rachel R | Permit type: Alteration permit | Permit status: Completed | Completion date: August 2, 2017 | Permit id: 748901 | |||||
SCORE 89 2407 Wharton St Philadelphia Pa 191464022 New construction of a multi fam dwelling 3 units with pilot house accessing a roof deck Date: April 5, 2017 Contractor: Tbc Llc Client: Tete Brothers Llc | Permit type: Zoning/use permit | Permit status: Completed | Completion date: April 5, 2017 | Permit id: 749027 | |||||
SCORE 89 124 Wolf St Philadelphia Pa 191483343 Veneer brick only on front wall-existing two story. Existing windows and door ez exterior wall coverings- for the application of exterior wall coverings as per attached standard. Deviations from this standard will result in permit revocation and require submission of construction plans. Date: September 22, 2015 Contractor: Tbc Llc Client: Gindhart William T | Permit type: Alteration permit | Permit status: Expired | Completion date: August 2, 2016 | Permit id: 640653 | |||||
SCORE 89 1726 Spruce St Philadelphia Pa 191036719 For the interior demolition of non load-bearing partition walls and ceilings as per attached standard. Deviations from this standard will result in permit revocation and require submission of construction plans Date: December 20, 2016 Contractor: Tbc Llc Permit type: Demolition permit | Permit status: Completed | Completion date: September 25, 2017 | Permit id: 744881 | |||||
SCORE 89 100 E Roosevelt Blvd Philadelphia Pa 191163918 Make safe permit - for (brief description of work as per engineer? S report if applicable) to resolve case #563038. Abutting sidewalk must be closed with fencing a minimum of 6? In height. Separate streets department permit required for sidewalk closure. A separate permit is required for any additional alterations that are not specifically addressed on case #563038. Furnish and install new anodized aluminum window frame, one tempered insulated glass unit, re-install customers existing frame inserts and glass. Interior- drywall patch, repair drop ceiling grid. Date: November 18, 2016 Contractor: Tbc Llc Client: Ard Red Lion Lp | Permit type: Alteration permit | Permit status: Completed | Completion date: November 30, 2016 | Permit id: 737855 | |||||
SCORE 89 807 N 2nd St Philadelphia Pa 191233009 Ez standard limited commercial alterations & repairs- for the limited demolition and commercial alterations as per attached standard. Deviations from this standard will result in permit revocation and require submission of construction plans. Date: July 30, 2015 Contractor: Tbc Llc Client: Katchik Holdings I Llc | Client Company: Katchik Holdings Llc | Permit type: Alteration permit | Permit status: Completed | Completion date: January 27, 2017 | Permit id: 628375 | |||||
SCORE 89 1226 S 27th St Philadelphia Pa 191463739 Apply stucco to 1 2 of front wall with existing windows and doors Date: October 15, 2015 Contractor: Tbc Llc Client: Piraine Richard F Ii Tete Jason | Permit type: Alteration permit | Permit status: Completed | Completion date: December 3, 2015 | Permit id: 645561 | |||||
SCORE 89 Date: August 4, 2017 Contractor: Tbc Llc Permit type: Demolition permit | Permit status: Active | Completion date: August 25, 2017 | Permit id: 805883 | |||||
SCORE 89 12 S 27th St Philadelphia Pa 191463734 Interior alterations to include drywall throughout, moisture resistant drywall in the bathroom and kitchen, new windows and doors in existing opening. Applicant agrees to limit the construction to comply with ez permit standard for interior alterations, dated january 2011. Deviation from the standard will result in revocation of this permit and imposition of further penalties. Separate permits required for plumbing, electrical and mechanical work,stucco rear of property,and new rubber roof Date: February 1, 2017 Contractor: Tbc Llc Client: Tete Jason | Permit type: Alteration permit | Permit status: Active | Completion date: November 7, 2017 | Permit id: 755633 | |||||
SCORE 89 Date: August 4, 2017 Contractor: Tbc Llc Permit type: Demolition permit | Permit status: Active | Completion date: August 25, 2017 | Permit id: 805881 | |||||
SCORE 89 Date: December 14, 2016 Contractor: Tbc Llc Permit type: Demolition permit | Permit status: Expired | Completion date: January 3, 2017 | Permit id: 743437 | |||||
SCORE 89 614 N 16th St Philadelphia Pa 191303410 For the construction of a three-story structure to be used as a three-family dwelling, as per approved plans. See app# 729729 for approved plans. Date: January 5, 2017 Contractor: Tbc Llc Client: Siobhan Trainor | Permit type: New construction permit | Permit status: Active | Completion date: October 6, 2017 | Permit id: 746148 | |||||
SCORE 89 2045 N College Ave Philadelphia Pa 191214806 For the erection of an attached structure with decks at the rear of the first, second, and third floors as per plans. Separate permits required for all mechanical, electrical, plumbing and fire suppression system. Date: December 16, 2016 Contractor: Tbc Llc Permit type: New construction permit | Permit status: Active | Completion date: August 7, 2017 | Permit id: 727570 | |||||
SCORE 89 1315 S Philip St Philadelphia Pa 19147 For the erection of a ez deck at rear of the single family dwelling Date: May 12, 2017 Contractor: Tbc Llc Permit type: Zoning permit | Permit status: Completed | Completion date: May 12, 2017 | Permit id: 783245 | |||||
SCORE 89 934 Dudley St Philadelphia Pa 191482321 Interior alterations to include drywall, sheet rock throughout the bathroom and kitchen, new windows and doors in existing opening. Applicant agrees to limit the construction to comply with ez permit standard for interior alterations, dated january 2011. Deviation from the standard will result in revocation of this permit and imposition of further penalties. Separate permits required for plumbing, electrical and mechanical work work to include stucco rear wall and remove old roof covering and replace with new roof covering Date: August 29, 2017 Contractor: Tbc Llc Client: Chiancone Dominick Z | Permit type: Alteration permit | Permit status: Active | Completion date: August 30, 2017 | Permit id: 812007 | |||||
SCORE 89 1117 Cross St Philadelphia Pa 191476301 Interior alterations to include drywall, sheet rock throughout the bathroom and kitchen, new windows and doors in existing opening. Applicant agrees to limit the construction to comply with ez permit standard for interior alterations, dated january 2011. Deviation from the standard will result in revocation of this permit and imposition of further penalties. Separate permits required for plumbing, electrical and mechanical work Date: June 1, 2017 Contractor: Tbc Llc Permit type: Alteration permit | Permit status: Active | Completion date: November 13, 2017 | Permit id: 788386 | |||||
SCORE 89 122832 W College Ave Philadelphia Pa 191214826 To amend permit# 686952 to include underpinning on southside of building, as per approved plans. Date: December 14, 2016 Contractor: Tbc Llc Client: Jfv Development Group Lp | Permit type: Administrative permit | Permit status: Completed | Completion date: August 1, 2017 | Permit id: 729668 | |||||
SCORE 89 1913 Kater St Philadelphia Pa 191461431 Erect addition at rear at 2nd and 3rd floors with roof deck and pilothouse. Date: September 15, 2015 Contractor: Tbc Llc Client: Ash Nancy | Permit type: Zoning permit | Permit status: Completed | Completion date: September 15, 2015 | Permit id: 635629 | |||||
SCORE 89 1315 S Philip St Philadelphia Pa 19147 Ez permit decks- for new decks accessory to an existing one family dwelling as per attached standard. Deviations from this standard will result in permit revocation and require submission of construction plans. Date: May 12, 2017 Contractor: Tbc Llc Permit type: Alteration permit | Permit status: Active | Completion date: November 8, 2017 | Permit id: 783178 | |||||
SCORE 89 8 E Thompson St Philadelphia Pa 19125 Construction of a three story detached single family dwelling with cellar, roof deck and access pilot house. Use as single family household living. Date: April 19, 2017 Contractor: Tbc Llc Permit type: New construction permit | Permit status: Completed | Completion date: November 21, 2017 | Permit id: 765910 | |||||
SCORE 89 143135 Frankford Ave Philadelphia Pa 191254409 For alterations to an existing structure to include relocation of doorways, installation of new accessible service counter and window, interior wall ceiling finishing, roof assembly replacement, and installation of steel bollards on site. (iebc 2009, compliance path: work-area method, level iii) separate permits required for electrical, plumbing, mechanical, and kitchen hood exhaust installations. Date: July 10, 2015 Contractor: Tbc Llc Client: Fishbone Real Estate 2013 | Permit type: Alteration permit | Permit status: Completed | Completion date: February 27, 2016 | Permit id: 610107 | |||||
SCORE 89 1804 Latona St Philadelphia Pa 191462919 Interior alterations to include drywall throughout, moisture resistant drywall in the bathroom and kitchen, new windows and doors in existing opening. Applicant agrees to limit the construction to comply with ez permit standard for interior alterations, dated january 2011. Deviation from the standard will result in revocation of this permit and imposition of further penalties. Separate permits required for plumbing, electrical and mechanical work Date: January 4, 2017 Contractor: Tbc Llc Client: Antage Real Estate Solut | Permit type: Alteration permit | Permit status: Completed | Completion date: October 30, 2017 | Permit id: 747814 | |||||
SCORE 89 2322 Pine St Philadelphia Pa 191036415 Interior demo of non-load bearing walls only, no structural work on this permit Date: August 16, 2017 Contractor: Tbc Llc Client: Wharton Kyle W Panarese Katharine | Permit type: Demolition permit | Permit status: Completed | Completion date: September 8, 2017 | Permit id: 808937 | |||||
SCORE 89 1317 S Philip St Philadelphia Pa 191476102 New construction of a single family home with garage with curb cut, roof deck, pilot house see ap 6921 for approved plans Date: July 28, 2016 Contractor: Tbc Llc Permit type: New construction permit | Permit status: Completed | Completion date: April 4, 2017 | Permit id: 708948 | |||||
SCORE 89 2025 N College Ave Philadelphia Pa 191214806 New construction of a three (3) story three-family dwelling with a roof deck and pilot house (access to roof deck only) as per approved plans. Building to be fully sprinklered. Separate permits required for mep & fire suppression work Date: January 30, 2017 Contractor: Tbc Llc Client: Secure Holdings Llc | Permit type: New construction permit | Permit status: Active | Completion date: September 12, 2017 | Permit id: 738488 | |||||
SCORE 89 242 Arch St Philadelphia Pa 191062204 Proposed new construction of a sfd as per plans see ap# 514863 for related documents Date: April 11, 2014 Contractor: Tbc Llc Permit type: New construction permit | Permit status: Completed | Completion date: August 24, 2016 | Permit id: 514873 | |||||
SCORE 89 805 Mountain St Philadelphia Pa 191481221 For the erection of a single family dwelling with roof deck accessed by pilot house. Seperate permit required for relocation of chimney on property line as per zba proviso. Date: June 23, 2015 Contractor: Tbc Llc Client: Forshee Charles Forshee Colleen K | Permit type: New construction permit | Permit status: Completed | Completion date: April 24, 2017 | Permit id: 612232 | |||||
SCORE 89 1313 S Ringgold St Philadelphia Pa 191464016 Interior alterations to include drywall throughout, moisture resistant drywall in the bathroom and kitchen, new windows and doors in existing opening. Applicant agrees to limit the construction to comply with ez permit standard for interior alterations, dated january 2011. Deviation from the standard will result in revocation of this permit and imposition of further penalties. Separate permits required for plumbing, electrical and mechanical work Date: July 26, 2016 Contractor: Tbc Llc Client: Ukes Mayeakeh S | Permit type: Alteration permit | Permit status: Completed | Completion date: May 18, 2017 | Permit id: 710349 | |||||
SCORE 89 1006 S 11th St Philadelphia Pa 191473817 For the erection of a three-story attached structure with pilothouse and roof deck to be used as a single-family dwelling. Building shall be fully sprinklered. Separate permits required for mechanical, electrical, plumbing, and fire suppression systems. Date: March 31, 2015 Contractor: Tbc Llc Client: Sairsingh Jeremy Sairsingh Holly | Permit type: New construction permit | Permit status: Completed | Completion date: October 1, 2015 | Permit id: 589742 | |||||
SCORE 89 944 S 50th St Philadelphia Pa 191433336 Ez permit stadard alterations-to (refinish floors, drywall, frame closets, new cabinets,) for alterations to an existing one family dwelling as per attached standard. Deviations from this standard will result in permit revocation and require submission of construction plans. Date: December 6, 2016 Contractor: Tbc Llc Client: Potluri Keerthi C Powell Domenic R | Permit type: Alteration permit | Permit status: Completed | Completion date: July 14, 2017 | Permit id: 741623 | |||||
SCORE 89 742 S 9th St Philadelphia Pa 191472837 Interior alterations to include drywall throughout, moisture resistant drywall in the bathroom and kitchen, new windows and doors in existing opening. Applicant agrees to limit the construction to comply with ez permit standard for interior alterations, dated january 2011. Deviation from the standard will result in revocation of this permit and imposition of further penalties. Separate permits required for plumbing, electrical and mechanical work,stucco rear of property Date: February 1, 2017 Contractor: Tbc Llc Permit type: Alteration permit | Permit status: Active | Completion date: October 12, 2017 | Permit id: 755568 | |||||
SCORE 89 8 E Thompson St Philadelphia Pa 19125 For the new construction of an attached three (3) story single family dwelling with cellar and roof deck accessed by a roof deck access structure; bay at 2nd and 3rd floors; deck at third floor rear, as per approved plans, Date: April 3, 2017 Contractor: Tbc Llc Permit type: New construction permit | Permit status: Active | Completion date: September 29, 2017 | Permit id: 765621 | |||||
SCORE 89 614 N 16th St Philadelphia Pa 191303410 For the construction of a three-story structure to be used as a three-family dwelling, as per approved plans. Date: January 5, 2017 Contractor: Tbc Llc Client: Siobhan Trainor | Permit type: New construction permit | Permit status: Active | Completion date: October 6, 2017 | Permit id: 729729 | |||||
SCORE 89 Date: April 11, 2014 Contractor: Tbc Llc Client: Beacon Of Arch Street Llc | Permit type: New construction permit | Permit status: Completed | Completion date: September 28, 2016 | Permit id: 514863 | |||||
SCORE 89 12 Ritner St Philadelphia Pa 191480000 Interior alterations to include drywall throughout, moisture resistant drywall in the bathroom and kitchen, new windows and doors in existing opening. Applicant agrees to limit the construction to comply with ez permit standard for interior alterations, dated january 2011. Deviation from the standard will result in revocation of this permit and imposition of further penalties. Separate permits required for plumbing, electrical and mechanical work Date: February 17, 2016 Contractor: Tbc Llc Client: Mcknown Michael | Permit type: Alteration permit | Permit status: Completed | Completion date: August 25, 2016 | Permit id: 670253 | |||||
SCORE 89 2043 Bainbridge St Philadelphia Pa 191461308 Interior alterations to include drywall, sheet rock throughout the bathroom and kitchen, new windows and doors in existing opening. Applicant agrees to limit the construction to comply with ez permit standard for interior alterations, dated january 2011. Deviation from the standard will result in revocation of this permit and imposition of further penalties. Separate permits required for plumbing, electrical and mechanical work Date: June 1, 2017 Contractor: Tbc Llc Permit type: Alteration permit | Permit status: Active | Completion date: October 19, 2017 | Permit id: 788373 | |||||
SCORE 89 1501 S Broad St Philadelphia Pa 191476206 Make safe permit to comply case #442636 according to engineers report Date: June 19, 2015 Contractor: Tbc Llc Client: Barbieri Craig Barbieri Elissa | Permit type: Alteration permit | Permit status: Completed | Completion date: September 16, 2016 | Permit id: 618891 | |||||
SCORE 89 Date: December 8, 2017 Contractor: Tbc Llc Client: Maneri Anthony L Amelia H W | Permit type: Demolition permit | Permit status: Active | Completion date: December 12, 2017 | Permit id: 838032 |