Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
SCORE 84 5 599 Block Of Pennsylvania Avenue Nw Washington Dc Additional permitting through the national park services was required and has now been issued. An existing steam and condensate line approximately ft from the curb line along pennsylvania ave. Will be electronically located. Approximately 35 locations will be identified where access will be required to the existing concrete conduit housing the steam and condensate lines. Test pits will be performed by non-destructive excavation with a vacuum excavator. Holes will be approximately 18"x18" and 8 deep to expose and provide access to an existing concrete conduit for a steam line. Foam insulation will be injected into the conduit, encasing the existing steam and condensate lines. The holes will be closed up and the disturbed area will be restored in kind. ![]() ![]() Client: Greg Westphal | Permit type: Excavation; boring test pit (each addl), excavation; boring test pit (single) | Permit status: Permit expired | Expiration date: May 19, 2016 | Permit id: Pa118820 | |||||
SCORE 84 5 599 Block Of Pennsylvania Avenue Nw Washington Dc Reference permit tracking number 1188 - requested dates have expired, permit was previously approved pending payment. Additional permitting through the national park services was required and has now been issued. No suspended roadway letter needed an existing steam and condensate line approximately ft from the curb line along pennsylvania ave. Will be electronically located. Approximately 35 locations will be identified where access will be required to the existing concrete conduit housing the steam and condensate lines. Test pits will be performed by non-destructive excavation with a vacuum excavator. Holes will be approximately 18"x18" and 8 deep to expose and provide access to an existing concrete conduit for a steam line. Foam insulation will be injected into the conduit, encasing the existing steam and condensate lines. The holes will be closed up and the disturbed area will be restored in kind. ![]() ![]() Client: Greg Westphal | Permit type: Excavation; boring test pit (each addl), excavation; boring test pit (single) | Permit status: Cancel/withdrawn | Expiration date: April 22, 2016 | |||||
SCORE 84 5 599 Block Of Pennsylvania Avenue Nw Washington Dc Reference permit tracking number 1188 - requested dates have expired, permit was previously approved pending payment. Additional permitting through the national park services was required and has now been issued. No suspended roadway letter needed an existing steam and condensate line approximately ft from the curb line along pennsylvania ave. Will be electronically located. Approximately 35 locations will be identified where access will be required to the existing concrete conduit housing the steam and condensate lines. Test pits will be performed by non-destructive excavation with a vacuum excavator. Holes will be approximately 18"x18" and 8 deep to expose and provide access to an existing concrete conduit for a steam line. Foam insulation will be injected into the conduit, encasing the existing steam and condensate lines. The holes will be closed up and the disturbed area will be restored in kind. ![]() ![]() Client: Greg Westphal | Permit type: Excavation; boring test pit (each addl), excavation; boring test pit (single) | Permit status: Cancel/withdrawn | Expiration date: April 22, 2016 | |||||
SCORE 84 5 599 Block Of Pennsylvania Avenue Nw Washington Dc Excavation; boring test pit (each addl), excavation; boring test pit (single) ![]() Permit status: 3 | Expiration date: April 22, 2016 | Permit id: 0 | |||||
SCORE 84 ![]() Permit status: Withdrawn | Expiration date: May 1, 2016 | Permit id: 0 | |||||
SCORE 84 ![]() Permit status: Withdrawn | Expiration date: May 1, 2016 | Permit id: 0 | |||||
SCORE 84 5 599 Block Of Pennsylvania Avenue Nw Washington Dc Additional permitting through the national park services was required and has now been issued. An existing steam and condensate line approximately ft from the curb line along pennsylvania ave. Will be electronically located. Approximately 35 locations will be identified where access will be required to the existing concrete conduit housing the steam and condensate lines. Test pits will be performed by non-destructive excavation with a vacuum excavator. Holes will be approximately 18"x18" and 8 deep to expose and provide access to an existing concrete conduit for a steam line. Foam insulation will be injected into the conduit, encasing the existing steam and condensate lines. The holes will be closed up and the disturbed area will be restored in kind. ![]() ![]() Client: Greg Westphal | Permit type: Excavation; boring test pit (each addl), excavation; boring test pit (single) | Permit status: Permit expired | Expiration date: May 19, 2016 | Permit id: Pa118820 | |||||
SCORE 84 5 599 Block Of Pennsylvania Avenue Nw Washington Dc Excavation; boring test pit (each addl), excavation; boring test pit (single) ![]() Permit status: 3 | Expiration date: April 22, 2016 | Permit id: 0 | |||||
SCORE 84 ![]() Permit status: Withdrawn | Expiration date: May 1, 2016 | Permit id: 0 | |||||
SCORE 84 ![]() ![]() Permit status: Permit expired | Expiration date: May 19, 2016 | Permit id: Pa10219132 | |||||
SCORE 84 ![]() Permit status: Withdrawn | Expiration date: May 1, 2016 | Permit id: 0 | |||||
SCORE 84 ![]() ![]() Client: Brian Coleman | Client Address: 1155-1205 Manhattan Avenue Brooklyn Ny 11222 | Client Phone: (718) 383-3935 | Client Company: Greenpoint Manufacturing & Desig | Permit status: Initial | Permit id: 320449010 | |||||
SCORE 84 ![]() ![]() Client: Brian Coleman | Client Address: 1155-1205 Manhattan Avenue Brooklyn Ny 11222 | Client Phone: (718) 383-3935 | Client Company: Greenpoint Manufacturing & Desig | Permit status: Initial | Permit id: 320449010 |