SCORE 82 1732 N 29th St Philadelphia Pa 191212719 Install new 100amp service,new branch circuit wiring,new lights(20),new plugs(10),new switches(15),new smoke detector and new grounding system as per nec 2008 (north district) all work done by fishing only ![]() ![]() Client: Amante Investment Group | Permit type: Electrical permit | Permit status: Active | Completion date: July 25, 2017 | Permit id: 802594 | |||||
SCORE 82 1933 W Pacific St Philadelphia Pa 191403913 Run new circuit. Install new smoke detectors. Run new grounding system and new plug and switch as per 2008 nec ![]() ![]() Client: Watson Joel C | Permit type: Electrical permit | Permit status: Expired | Completion date: December 22, 2016 | Permit id: 745341 | |||||
SCORE 82 2421 E Cumberland St Philadelphia Pa 191253104 Total rewire, run branch circuit for smoke detector. Install new grounding system as per nec 2008. Code, install new 2 amp service & 200amp panel box. ![]() ![]() Client: Fox Development Corp | Permit type: Electrical permit | Permit status: Active | Completion date: November 21, 2017 | Permit id: 833971 | |||||
SCORE 82 8 S 12th St Philadelphia Pa 191472603 Fishing branch circuit in walls install new lights, new smoke detectors lines,install 2 new panel box, new plugs and switches tr rated as per 2008 nec (south district) ![]() ![]() Client: Cornerstone Urban Project | Permit type: Electrical permit | Permit status: Active | Completion date: October 11, 2017 | Permit id: 823025 | |||||
SCORE 82 8 S 12th St Philadelphia Pa 191472603 Install 1-2 amp service cable wire, new 2 amp panel box, new circuit panel a new grounding system per 2008 code ![]() ![]() Client: Cornerstone Urban Project | Permit type: Electrical permit | Permit status: Active | Completion date: August 18, 2017 | Permit id: 809712 | |||||
SCORE 82 2034 Mercy St Philadelphia Pa 191452807 Install new panel box & new grounding stysem & install outlets, & switches, ceiling fans & lights, wire kitchen ckts & branch ckts as per nec 2008 south district ![]() ![]() Client: Barton Irene E Matthew B D F | Permit type: Electrical permit | Permit status: Completed | Completion date: October 3, 2016 | Permit id: 711164 | |||||
SCORE 82 25 S Gross St Philadelphia Pa 191423114 Install new 1 amp service. Install ne ground rod, install new grounding system, run new lines for smoke detector & branch circuit as per 2008 nec (west district) ![]() ![]() Client: Rivera Ligia | Permit type: Electrical permit | Permit status: Expired | Completion date: March 10, 2017 | Permit id: 763799 | |||||
SCORE 82 7056 Greenhill Rd Philadelphia Pa 191512321 Install new 1 amp service, wire recepticals, switches, smoke detectors. New branch circuit new grounding system as per 2008 nec ![]() ![]() Client: Tzinger Yosef Y | Permit type: Electrical permit | Permit status: Expired | Completion date: August 3, 2017 | Permit id: 792968 | |||||
SCORE 82 7056 Greenhill Rd Philadelphia Pa 191512321 Install new 2 amp service, wire receptacels, switches, smoke detectors. New branch circuit new grounding system as per 2008 nec ![]() ![]() Client: Tzinger Yosef Y | Permit type: Electrical permit | Permit status: Active | Completion date: August 3, 2017 | Permit id: 805254 | |||||
SCORE 82 6034 Kershaw St Philadelphia Pa 191514423 Install new branch circuit throughout, install new smoke detector circuit, install new grounding system as per nec code 2008, install new 1 amp service ![]() ![]() Client: Bsd Ya Llc | Permit type: Electrical permit | Permit status: Active | Completion date: September 11, 2017 | Permit id: 815141 | |||||
SCORE 82 404951 Market St Philadelphia Pa 191043031 Wire throughout,change out 100amp sub panel,change out 200amp panel with main break per 2008 nec (grocery store)install fire alarm system complete per nfpa 72 ![]() ![]() Client: Harmen Properties Llc | Permit type: Electrical permit | Permit status: Active | Completion date: November 7, 2017 | Permit id: 749097 | |||||
SCORE 82 6239 Washington Ave Philadelphia Pa 191432916 Install new 100amp service,new grounding system,new branch circuit,smoke detector,install new plugs,switches,new fixture and door bell as per 2008 nec (west district) ![]() ![]() Client: Nti Properties Llc | Permit type: Electrical permit | Permit status: Expired | Completion date: May 30, 2017 | Permit id: 787673 | |||||
SCORE 82 1632 N 3rd St Philadelphia Pa 191223003 Install new branch circuit new panel box install new outlet and switches install new grounding system as per code nec 2008 install new smoke detector ![]() ![]() Client: Purcell Christopher | Permit type: Electrical permit | Permit status: Expired | Completion date: March 27, 2017 | Permit id: 769639 | |||||
SCORE 82 6114 Sansom St Philadelphia Pa 191393049 Install new 1 amp service,branch system, new grounding system, smoke detectors, receptacles and 15 switches ![]() ![]() Client: Agl Capital Investments L | Permit type: Electrical permit | Permit status: Expired | Completion date: October 21, 2016 | Permit id: 731013 | |||||
SCORE 82 7819 Temple Rd Philadelphia Pa 191502109 Install new 1 amp service,branch system, new grounding system, smoke detectors, receptacles and 15 switches ![]() ![]() Client: Right Time Re Llc | Permit type: Electrical permit | Permit status: Expired | Completion date: March 30, 2017 | Permit id: 730993 | |||||
SCORE 82 W Sharpnack St Philadelphia Pa 191192720 100amp service, grounding system, run new branch circuit, smoke detector as per nec 2008 north district ![]() ![]() Client: Mamo Genet | Permit type: Electrical permit | Permit status: Active | Completion date: November 28, 2017 | Permit id: 834901 | |||||
SCORE 82 1809 S Taylor St Philadelphia Pa 191451814 Run new branch circuit, install new smoke detector. Install new grounding system as per nec 2008 code. Install new 100amp service & panel box. ![]() ![]() Client: Wntown Digs Llc | Permit type: Electrical permit | Permit status: Active | Completion date: November 21, 2017 | Permit id: 833975 | |||||
SCORE 82 131 E Upsal St Philadelphia Pa 191192340 Replace 100amp with 200amp service , 200amp panel & grounding install branch ckts in kitchen area, install 10-lights, 15-recepts, outlet, & switches as per nec 2008 north district ![]() ![]() Client: Prec Homes Ii Lp | Permit type: Electrical permit | Permit status: Completed | Completion date: April 25, 2017 | Permit id: 711153 | |||||
SCORE 82 1721 S 5th St Philadelphia Pa 191481848 Install new branch circuit, new grounding system, new hardwire smoke detector, new plugs and switch, new lights, upgrade service from 100amp to 200amp as per nec 2008 code (south district) ![]() ![]() Client: Boyd Emmitt L Boyd Nicolette O | Permit type: Electrical permit | Permit status: Active | Completion date: November 30, 2017 | Permit id: 792525 | |||||
SCORE 82 2317 W Thompson St Philadelphia Pa 191214712 Install new 1 amp service install new grounding system as per nec 2008. Install replacement light fixtures, install replacment outlets ![]() ![]() Client: Alvin Flamer Dorothy B | Permit type: Electrical permit | Permit status: Active | Completion date: December 1, 2017 | Permit id: 835969 | |||||
SCORE 82 28 W Stiles St Philadelphia Pa 191210000 Change lights fixture, run new branch circuit, install new grounding system and install new plugs and switches as per nec code 2008 (sfd)north district ![]() ![]() Client: Kennedy Dia | Permit type: Electrical permit | Permit status: Expired | Completion date: December 20, 2016 | Permit id: 744888 | |||||
SCORE 82 4326 Wyalusing Ave Philadelphia Pa 191041227 Install new 200amp servcie,install new grounding system. Install new panel and meter socket per 2008 nec (sfd) ![]() ![]() Client: East Parkside Properties | Permit type: Electrical permit | Permit status: Active | Completion date: September 26, 2017 | Permit id: 819111 | |||||
SCORE 82 1833 S 22nd St Philadelphia Pa 191451939 200amp service with 1-meter box, panel, grounding system & total rewire lights & plugs, smoke detectors as per nec 2008 south district ![]() ![]() Client: Jackson Elizabeth | Permit type: Electrical permit | Permit status: Active | Completion date: November 28, 2017 | Permit id: 834898 | |||||
SCORE 82 3031 N 24th St Philadelphia Pa 191321311 Run new branch circuits,install new ground system,install new hard wired smoke and install (1)200amp service system. Install 15 outlets, lights and 18 switches per 2008 nec (sfd) ![]() ![]() Client: Candio Jeanne L | Client Company: Candio Jeanne L. | Permit type: Electrical permit | Permit status: Active | Completion date: August 3, 2017 | Permit id: 804868 | |||||
SCORE 82 26 Catharine St Philadelphia Pa 191462312 Total re-wire, 200a service, 40- circuit panel; wire dishwasher, disposal and central air ... In accordance with 2008 nec for a one family building ![]() ![]() Client: Sembhi Tarvinder Sembhi Harnaik | Permit type: Electrical permit | Permit status: Active | Completion date: August 23, 2017 | Permit id: 810683 | |||||
SCORE 82 3526 N 17th St Philadelphia Pa 191404002 Install new recepts and grounding system and new panel box and general wiring throughout as per 2008 nec (north district) ![]() ![]() Permit type: Electrical permit | Permit status: Expired | Completion date: December 5, 2016 | Permit id: 741140 | |||||
SCORE 82 1244 S 23rd St Philadelphia Pa 191464133 Install new grounding system as per code 2008 nec. Install and run circuit fix smoke detector and move outlets as per code article 2 outlet spacing install new tr rated outlets and change out all lights and switches. Per 2008 nec. ![]() ![]() Client: Buck Exteriors Llc | Permit type: Electrical permit | Permit status: Expired | Completion date: May 31, 2017 | Permit id: 777669 | |||||
SCORE 82 27 N 58th St Philadelphia Pa 191392410 Rewire run new branch circuit new smoke detectors,new plugs and switches. New 200amp service cable and new grounding per 2008 nec (sfd) ![]() ![]() Client: Belize Capital Llc | Permit type: Electrical permit | Permit status: Active | Completion date: September 19, 2017 | Permit id: 817158 | |||||
SCORE 82 703 S 55th St Philadelphia Pa 191432505 Install new 1 amp service,branch system, new grounding system, smoke detectors, receptacles and 15 switches ![]() ![]() Client: Avigdor Investments Llc | Permit type: Electrical permit | Permit status: Expired | Completion date: October 21, 2016 | Permit id: 731014 | |||||
SCORE 82 615 Pierce St Philadelphia Pa 191481719 Install new 100amp service,run smoke detectors lines,install 6 new branch circuits,install new grounding system. Install 12 new lights, plugs and 12 switches per 2008 nec (sfd) ![]() ![]() Client: Williams Vanessa | Permit type: Electrical permit | Permit status: Active | Completion date: June 14, 2017 | Permit id: 792017 | |||||
SCORE 82 48 E Logan St Philadelphia Pa 191443017 Upgrade service to 100amp,new grounding system,new branch circuits and new recepts and lights and smokes as per 2008 nec (north district) ![]() ![]() Client: Littlepage Garnett C | Permit type: Electrical permit | Permit status: Expired | Completion date: December 5, 2016 | Permit id: 741139 | |||||
SCORE 82 64951 N 35th St Philadelphia Pa 191041942 Install new plugs and switches,run new branch circuits,install new panel and grounding system with new fixtures as per 2008 nec (west district) ![]() ![]() Client: Twin Properties Llc | Permit type: Electrical permit | Permit status: Expired | Completion date: November 3, 2016 | Permit id: 734320 | |||||
SCORE 82 22 Ellsworth St Philadelphia Pa 191462812 Install new 100amp panel with grounding system and branch circuits for 10-lights and 15-plugs and smokes as per 2008 nec (south district) ![]() ![]() Client: Poirette-Lanteaume Nichollarson Micaela | Permit type: Electrical permit | Permit status: Completed | Completion date: August 14, 2017 | Permit id: 741138 | |||||
SCORE 82 404951 Market St Philadelphia Pa 191043031 Install 2 amp service meter socket 18x18x6" service end box only as per 2008 nec (west district) ![]() ![]() Client: Harmen Properties Llc | Permit type: Electrical permit | Permit status: Completed | Completion date: November 7, 2017 | Permit id: 823027 | |||||
SCORE 82 1321 N Myrtlewood St Philadelphia Pa 191214516 Install new panel change seu cable from and to 100amp. Install new plugs 10, switch 12, smoke detectors and new grounding system as per nec 2008 ![]() ![]() Client: Sweetinvestt Llc | Permit type: Electrical permit | Permit status: Expired | Completion date: January 9, 2017 | Permit id: 748713 | |||||
SCORE 82 528 Moore St Philadelphia Pa 191481829 Change out old plug and install tr type plugs. Install fixtures change panel box to 200amp. Install new grounding system run washer,dryer a c lines and install breakers per 2008 nec (sfd) ![]() ![]() Client: Street Rachel | Permit type: Electrical permit | Permit status: Abandoned | Completion date: October 20, 2017 | Permit id: 806429 | |||||
SCORE 82 6615 Gerry St Philadelphia Pa 191382613 Install new 1 amp service,branch system, new grounding system, smoke detectors, receptacles and 15 switches ![]() ![]() Client: Sv Pa Phi 1 Llc | Permit type: Electrical permit | Permit status: Expired | Completion date: October 21, 2016 | Permit id: 730992 | |||||
SCORE 82 2127 Fernon St Philadelphia Pa 191451302 Install new grounding system as per nec 2008 code, install new branch circuit run new smoke. Circuit new switch and plugs, new 1 amp service. ![]() ![]() Client: Mundle Paul Mundle Ann-Marie | Permit type: Electrical permit | Permit status: Active | Completion date: August 25, 2017 | Permit id: 811451 | |||||
SCORE 82 ![]() ![]() Client: Purcell Christopher | Permit type: Electrical permit | Permit status: Expired | Completion date: March 27, 2017 | Permit id: 769642 | |||||
SCORE 82 3143 W Dakota St Philadelphia Pa 191323313 Install 200amp service,new panel box and new grounding per 2008 nec (sfd) ![]() ![]() Client: Mc Fadden Elder Mc Fadden Joeann | Permit type: Electrical permit | Permit status: Active | Completion date: November 16, 2017 | Permit id: 832848 | |||||
SCORE 82 25 S Gross St Philadelphia Pa 191423114 Install 100amp service, install new grounding system & rewire throughout as per nec 2008 west district ![]() ![]() Client: Rivera Ligia | Permit type: Electrical permit | Permit status: Expired | Completion date: March 13, 2017 | Permit id: 766174 | |||||
SCORE 82 2554 Sepviva St Philadelphia Pa 191250000 Install (1)200amp,install new grounding system,new smoke detectors hard wire,new branch circuits, switch,15 plugs,12 lights and bond all gas pipes per 2008 nec (sfd) ![]() ![]() Client: Simons Harry | Permit type: Electrical permit | Permit status: Active | Completion date: August 3, 2017 | Permit id: 805070 | |||||
SCORE 82 412 Greenwich St Philadelphia Pa 191476523 Install 4 recess can lights run new line for refrigerator ,dishwasher,counter top in kitchen per 2008 nec (sfd) ![]() ![]() Client: Wescott Lynanne S | Permit type: Electrical permit | Permit status: Completed | Completion date: November 7, 2017 | Permit id: 816406 | |||||
SCORE 82 6613 Gerry St Philadelphia Pa 191382613 Install new 1 amp service,branch system, new grounding system, smoke detectors, receptacles and 15 switches ![]() ![]() Client: Sv Pa Phi 1 Llc | Permit type: Electrical permit | Permit status: Expired | Completion date: October 21, 2016 | Permit id: 730988 | |||||
SCORE 82 1765 N 29th St Philadelphia Pa 191212718 Fishing wires and install outlets and lights. Install new grounding system,install new smoke detectors, new plugs and switches. Install new 200amp service per 2008 nec (sfd) ![]() ![]() Client: Wims & Partners Realty Gr | Client Company: Wims& Partners Realty Gro | Permit type: Electrical permit | Permit status: Active | Completion date: September 21, 2017 | Permit id: 817163 | |||||
SCORE 82 5929 Larchwood Ave Philadelphia Pa 191431115 Run new circuit. Install new smoke detectors. Run new grounding system and new plug and switch as per 2008 nec ![]() ![]() Client: Martin Grace E | Permit type: Electrical permit | Permit status: Expired | Completion date: December 22, 2016 | Permit id: 745344 | |||||
SCORE 82 3046 Redner St Philadelphia Pa 191213510 Install new 1 amp service replace lights, outlets and switches, install new grounding system as per nec 2008 code north district ![]() ![]() Client: Hightower Nathaniel | Permit type: Electrical permit | Permit status: Active | Completion date: December 1, 2017 | Permit id: 836244 | |||||
SCORE 82 2013 N Gratz St Philadelphia Pa 191211511 Install new plugs and switches tk related new circuit for smoke detectors new branch circuits throughout. New 1 amp new grounding system total rewire as per 2008 nec. ![]() ![]() Client: Cooper Shirley | Permit type: Electrical permit | Permit status: Expired | Completion date: April 24, 2017 | Permit id: 777662 | |||||
SCORE 82 25 Ingersoll St Philadelphia Pa 191214718 Total rewire, new fixtures, new plug and switches, new 2 amp service, new grounding system as per nfc 2008 code (sfd) ![]() ![]() Client: Fenix Property Group Ii L | Permit type: Electrical permit | Permit status: Active | Completion date: September 21, 2017 | Permit id: 818198 | |||||
SCORE 82 7438 Rockwell Ave Philadelphia Pa 191113008 Install new seu cable install new panel box, install new breakers, install new grounding system as per nec 2008 code, change out all plugs and switches. ![]() ![]() Client: Lee Nicole | Client Company: Nicole Lee | Permit type: Electrical permit | Permit status: Active | Completion date: August 16, 2017 | Permit id: 808625 | |||||
SCORE 82 60 Cobbs Creek Pkwy Philadelphia Pa 191432327 Run new circuit. Install new smoke detectors. Run new grounding system and new plug and switch as per 2008 ![]() ![]() Client: Jacay Holdings Llc | Permit type: Electrical permit | Permit status: Expired | Completion date: December 22, 2016 | Permit id: 745343 | |||||
SCORE 82 390006 Chestnut St Philadelphia Pa 191043111 Install led drop ceiling light install new plugs 25 install new switches new exit emergency lights 2 install 5 wall pack emergency light and 3 6" recess fan light ![]() ![]() Client: Aimco Chestnut Hall Ltd Partnership | Client Company: Ryan, Llc | Permit type: Electrical permit | Permit status: Active | Completion date: September 8, 2017 | Permit id: 814592 | |||||
SCORE 82 1508 N Myrtlewood St Philadelphia Pa 191213634 Install new 100amp service, new branch circuit wiring,new lights(10),new plugs(15),new smoke detector(6) and new grounding system as per nec 2008 (north district) ![]() ![]() Permit type: Electrical permit | Permit status: Active | Completion date: July 25, 2017 | Permit id: 802592 | |||||
SCORE 82 2224 Cross St Philadelphia Pa 191464203 Total rewire, install new 200amp service and new grounding system as per nec 2008 south district ![]() ![]() Permit type: Electrical permit | Permit status: Active | Completion date: August 31, 2017 | Permit id: 812530 | |||||
SCORE 82 1314 E Oxford St Philadelphia Pa 191253217 Install new lights, new plugs and switches run some new wire, install new grounding and panel and smoke detectors ![]() ![]() Client: Pak Andrei G | Permit type: Electrical permit | Permit status: Active | Completion date: August 2, 2017 | Permit id: 755165 | |||||
SCORE 82 2226 Oakford St Philadelphia Pa 191464223 Install new branch circuit, new smoke detector new grounding system new plug new lights 12, new switches 15 and new 1 amp service as per nec 2008 ![]() ![]() Client: Specialized Ira Services Qnp 401k Td 100-856 | Client Company: Csc Ingeo | Permit type: Electrical permit | Permit status: Active | Completion date: July 26, 2017 | Permit id: 803025 | |||||
SCORE 82 2144 Medary Ave Philadelphia Pa 191382540 Install new fixtures, install new outlets,install new panel and breakers, new smoke detectors and new grounding system per 2008 nec (sfd)east district ![]() ![]() Client: Yaya Holdings Llc | Permit type: Electrical permit | Permit status: Active | Completion date: November 30, 2017 | Permit id: 743805 | |||||
SCORE 82 349 E Armat St Philadelphia Pa 191441300 Upgrade service to 200amp, run broad circuit install new smoke detector and new grounding system and install outlets, 12 switch and lights 5 as per 2008 nec ![]() ![]() Client: Tarlton Properties Inc | Permit type: Electrical permit | Permit status: Expired | Completion date: January 9, 2017 | Permit id: 748716 | |||||
SCORE 82 6114 Chancellor St Philadelphia Pa 191393702 Install new 1 amp service,branch system, new grounding system, smoke detectors, receptacles and 15 switches ![]() ![]() Client: Stevenson John Hugh | Permit type: Electrical permit | Permit status: Expired | Completion date: October 21, 2016 | Permit id: 731011 | |||||
SCORE 82 6312 N Norwood St Philadelphia Pa 191382530 Replace 1 service, grounding system, fishing wire for 28-plug, 10-switches, smoke detector and 10-lights as per nec 2008 north district ![]() ![]() Client: Avc 2 Property Investment | Permit type: Electrical permit | Permit status: Expired | Completion date: December 15, 2016 | Permit id: 743765 | |||||
SCORE 82 2615 N 9th St Philadelphia Pa 191331919 Install new 200amp service branch circuit smoke detectors circuit grounding system as per nec 2008 code install new 200amp service cable ![]() ![]() Client: Weir Rohan Anthony | Permit type: Electrical permit | Permit status: Expired | Completion date: April 24, 2017 | Permit id: 777665 | |||||
SCORE 82 2528 N 30th St Philadelphia Pa 191323004 Install new grounding system, hard wire smoke detector. Grounding water heater, grounding gas line as per 2008 nec. ![]() ![]() Client: Rayton Kijuana | Permit type: Electrical permit | Permit status: Active | Completion date: September 14, 2017 | Permit id: 816005 | |||||
SCORE 82 94 Lansford St Philadelphia Pa 191142626 Install 1 hardwired smoke,remove 1 outlet over baseboard heater,install 1 gfci in kitchen run line for refrigerator,install 1 outside wall lights and gfci outlet and install intersystem ground bar per 2008 nec (sfd) ![]() ![]() Client: Balilaj Maksim | Permit type: Electrical permit | Permit status: Active | Completion date: September 15, 2017 | Permit id: 816407 | |||||
SCORE 82 2119 Ruffner St Philadelphia Pa 191402817 Install new service 200ap new branch circuit and smoke detectors and new switches and plugs and new grounding system as per nec 2008 code ![]() ![]() Client: Wilson Tyrone | Permit type: Electrical permit | Permit status: Expired | Completion date: April 24, 2017 | Permit id: 777664 | |||||
SCORE 82 5538 Broomall St Philadelphia Pa 191434009 Install new branch circuit,12 new lights,20,new plug,new grounding system new panel and new smoke detector as per nec 2008 (west district) ![]() ![]() Client: S Dioses Llc | Permit type: Electrical permit | Permit status: Expired | Completion date: December 15, 2016 | Permit id: 743767 | |||||
SCORE 82 952 Allengrove St Philadelphia Pa 191242410 Run new branch circuit, run circuit for smoke detector and install new 100amp service and install new ground rod and water main ground system as per nec 2008 (east district) ![]() ![]() Client: Wls Nest Properties Llc | Permit type: Electrical permit | Permit status: Active | Completion date: October 17, 2017 | Permit id: 824689 | |||||
SCORE 82 2127 Bainbridge St Philadelphia Pa 191461205 Install 1-2 amp 3 meter outlet equipment new grounding system as per nec 2008 code install new branch circuit outlets 15 switches 15 lights new smoke detector and 1 house panel ![]() ![]() Client: Stein Mark Susanin Elizabeth | Permit type: Electrical permit | Permit status: Abandoned | Completion date: September 8, 2017 | Permit id: 803715 | |||||
SCORE 82 6746 N Bouvier St Philadelphia Pa 191262610 Install 1-2 amp service, new grounding system as per nec 2008 code, complete re-wire, smoke detectors and new lights, plugs ![]() ![]() Client: Jones Harriett E Jones Harry H | Permit type: Electrical permit | Permit status: Active | Completion date: December 1, 2017 | Permit id: 835971 | |||||
SCORE 82 3501 Bowman St Philadelphia Pa 191291510 Run new circuit, install new gate opening box controller and install new breaker for gate ![]() ![]() Client: Tiger Real Estate Inc | Permit type: Electrical permit | Permit status: Active | Completion date: August 31, 2017 | Permit id: 812525 | |||||
SCORE 82 12 E Pike St Philadelphia Pa 191245520 Fishing wires for plug and switches and light and smoke detectors install 1-100amp panel box and load side seu #2 cable and new grounding system as per nec 2008 code east district ![]() ![]() Client: Eutsche Bank National Tr | Permit type: Electrical permit | Permit status: Active | Completion date: December 14, 2017 | Permit id: 839429 | |||||
SCORE 82 57 N Yewdall St Philadelphia Pa 191392540 On an existing 100amp service,run new branch circuit,grounding system and wire to recepts,switches,lights,fixtures,smokes and co detectors as per 2008 nec (west district) ![]() ![]() Client: Sinyangwe Henry | Permit type: Electrical permit | Permit status: Active | Completion date: December 5, 2017 | Permit id: 836998 |