Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
SCORE 91 Date: May 15, 2001 Contractor: R And T Construction Permit status: Permit issued | Permit id: 10252678601 | |||||
SCORE 91 Date: January 9, 2004 Contractor: R And T Construction Permit status: Permit issued | Permit id: 40175983301 | |||||
SCORE 91 Date: September 5, 2007 Contractor: R And T Construction Permit status: Permit issued | Permit id: 10487885701 | |||||
SCORE 91 Date: October 6, 2006 Contractor: R And T Construction Permit status: Permit issued | Permit id: 10440825903 | |||||
SCORE 91 Date: October 6, 2006 Contractor: R And T Construction Permit status: Permit issued | Permit id: 10457528301 | |||||
SCORE 91 Date: December 27, 2007 Contractor: R And T Construction Permit status: Permit issued | Permit id: 11003036901 | |||||
SCORE 91 Date: September 14, 2006 Contractor: R And T Construction Permit status: Permit issued | Permit id: 10453349901 | |||||
SCORE 91 4 Stoner Rd, Asheville, Nc 28803 Install brick veneer.; recd amendment to remove and rebuild existing steps;cah; october 24, 2007 11:27:48 am ssalyer created no charge fire permit per jeff payne;sls; building safety comments proper non-combustible lintels are required to support brick work above openings. Be prepared to document the adequacy of the lintel used in a particular location if so requested by the field inspector. Expansion joints shall be provided where required (aci 530/asce5/tms402). Call jim reato at redacted phone number to schedule inspection. To activate subcontractors permits call redacted phone number.; planning level one approved fairmont baptist church replacement of 2 landings. Pmd; building safety comments amended 7/16/02 to include replacement of two sets of stairs. Coordinate safety issues with the field inspector. If building is to be ocupied then two acceptable Client: Fairmont Miss. Bapt. | Permit type: Com: remodel | Permit status: Closed | Current use: Commercial | Permit id: 02-02136 | Parcel: 16682 | |||||
SCORE 91 301 Pearson Dr, Asheville, Nc 28801 Residential chimney repairs;scc; 8/9/04 3:45:23 pm, residential chimney repairs. Issued by ssb.; demolition and rebuild of chimney with new flue. Inspection required: for final inspection contact the building inspector, maro slaughter at redacted phone number. The contractor must provide means of access to the roof for the building inspector. Recommend calling for inspection before removing the scaffolding. Proper cricket and flashing shall be installed in accordance with the code. Aluminimum flashing is not permitted except for counterflashing. Ess Client: Konz Chimney | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 04-03490 | Parcel: 19951 | |||||
SCORE 91 21 Edwin Pl, Asheville, Nc 28801 Rebuild deteriorated chimney. Clc; building safety comments see the review comments sheet for additional information and requirements. For building inspections call maro slaughter at redacted phone number. All subcontractors need to complete trade application for project. Subcontractors need to either visit the permit office or fax copy of application to (828)redacted phone number for activation of electrical, plumbing and mechanical permits. Client: Unitarian Church | Permit type: Com: remodel | Permit status: Closed | Current use: Commercial | Permit id: 05-04842 | Parcel: 23495 | |||||
SCORE 91 Date: January 9, 2004 Contractor: R And T Construction Permit status: Permit issued | Permit id: 40175983301 |