SCORE 96 18837 Colima Rd La Puente Ca 91744 Add 1 layer to existing one layer with class a fire rated pvc cool roof (durolast),approx 70 sf. Applicant: Premium Roof Services Inc | Permit status: Finaled | Completion date: February 27, 2015 | Permit id: 1412030075 | |||||
SCORE 96 27524 The Old Rd Los Angeles Ca Re-roof restaurant - add (1) layer durofold (3/8") over (e) roof, install duro last pvc 2,0 sq ft Engineer: N, A | Applicant: Premium Roof Services | Permit status: Finaled | Completion date: September 6, 2012 | Expiration date: July 11, 2013 | Permit id: 1207110059 | |||||
SCORE 96 18837 Colima Rd La Puente Ca Add 1 layer to existing one layer with class a fire rated pvc cool roof (durolast), approx 70 sf. Applicant: Premium Roof Services Inc | Permit status: Finaled | Completion date: February 27, 2015 | Expiration date: December 3, 2015 | Permit id: 1412030075 | |||||
SCORE 96 1425 Cuyamaca Ave Spring Valley Ca 91977 Res reroof; 1600sf if a re-roof project is proposed, the following specifications apply. Existing roofing material tile proposed roofing material comp shingles manufacturer owens corning brand and model true definition - duration (amber) color (if cool roof required) built-up roofing assembly system number per attached listing report (if applicable) specific exemption from cool roof requirements (if applicable) na required building inspector field verification (if applicable) yes note self-certification of interior attic by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Residential alteration-addn | Permit status: Completed | Completion date: December 13, 2016 | Permit id: Pds2016-Resalt- | |||||
SCORE 96 3352 Bonita Mesa Rd Bonita Ca 91902 46 sf reroof for existing sfd. If a re-roof project is proposed, the following specifications apply. Existing roofing material asphalt shingles proposed roofing material asphalt shingles manufacturer owens-corning brand and model trudefinition duration sierra grey color (if cool roof required) n a built-up roofing assembly system number per attached listing report (if applicable) n a specific exemption from cool roof requirements (if applicable) climate zone 7 required building inspector field verification (if applicable) n a note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Residential alteration-addn | Permit status: Completed | Completion date: May 7, 2015 | Permit id: Pds2015-Resalt- | |||||
SCORE 96 5209 Nannette St Bonita Ca 91902 40 sf reroof for existing sfd. If a re-roof project is proposed, the following specifications apply. Existing roofing material asphalt shingles (35 sf) and built-up (500sf) proposed roofing material asphalt shingles (35 sf) and single-ply thermoplastic (500sf) manufacturer shinges - owens corning, thermoplastic - duro-last brand and model shingles - tru definition duration desert tan thermpolastic - single ply pvc color (if cool roof required) n a thermoplastic roofing assembly system number per attached listing report (if applicable) 54 specific exemption from cool roof requirements (if applicable) climate zone 7 required building inspector field verification (if applicable) n a note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Residential alteration-addn | Permit status: Completed | Completion date: May 7, 2015 | Permit id: Pds2015-Resalt- | |||||
SCORE 96 1218 Buena Vista Ave Spring Valley Ca 91977 2500sf reroof for existing sfd. If a re-roof project is proposed, the following specifications apply. Existing roofing material shingles proposed roofing material shingles manufacturer owens corning brand and model tru definition duration color (if cool roof required) shasta white built-up roofing assembly system number per attached listing report (if applicable) na specific exemption from cool roof requirements (if applicable) na required building inspector field verification (if applicable) note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Residential alteration-addn | Permit status: Completed | Completion date: May 23, 2016 | Permit id: Pds2016-Resalt- | |||||
SCORE 96 3338 S Bonita St Spring Valley Ca 91977 2600sf re-roof for existing sfd if a re-roof project is proposed, the following specifications apply. Existing roofing material to be removed (comp shingle) proposed roofing material comp shingle manufacturer owens corning brand and model oakridge color (if cool roof required) shasta white built-up roofing assembly system number per attached listing report (if applicable) specific exemption from cool roof requirements (if applicable) required building inspector field verification (if applicable) note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Residential alteration-addn | Permit status: Completed | Completion date: April 14, 2015 | Permit id: Pds2015-Resalt- | |||||
SCORE 96 82 Loma View Ct Spring Valley Ca 91977 26 sf re-roof for existing patio and sfd. If a re-roof project is proposed, the following specifications apply. Existing roofing material tile main house built-up patio proposed roofing material tile main house built-up patio manufacturer eagle main house duro last patio brand and model capistrano main house color (if cool roof required) kona red main house bright white patio built-up roofing assembly system number per attached listing report (if applicable) n a specific exemption from cool roof requirements (if applicable) n a required building inspector field verification (if applicable) n a note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Residential alteration-addn | Permit status: Completed | Completion date: March 24, 2015 | Permit id: Pds2015-Resalt- | |||||
SCORE 96 107 Eureka Rd Spring Valley Ca 91978 22 sf re-roof for existing sfd. If a re-roof project is proposed, the following specifications apply. Existing roofing material asphalt shingle proposed roofing material asphalt shingle manufacturer owens-corning brand and model oakridge color (if cool roof required) shasta white built-up roofing assembly system number per attached listing report (if applicable) n a specific exemption from cool roof requirements (if applicable) n a required building inspector field verification (if applicable) n a note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Residential alteration-addn | Permit status: Completed | Completion date: March 30, 2015 | Permit id: Pds2015-Resalt- | |||||
SCORE 96 9553 Chimney Rock Ln El Cajon Ca 92021 2700sqft re-roof () for existing sfd. If a re-roof project is proposed, the following specifications apply. Existing roofing material concrete tile proposed roofing material concrete tile manufacturer eagle brand and model capistrano color (if cool roof required) brown built-up roofing assembly system number per attached listing report (if applicable) n a specific exemption from cool roof requirements (if applicable) n a required building inspector field verification (if applicable) n a note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Residential alteration-addn | Permit status: Completed | Completion date: February 24, 2015 | Permit id: Pds2015-Resalt- | |||||
SCORE 96 9164 Berkview Ln Spring Valley Ca 91977 2300sqft re-roof () for existing sfd. If a re-roof project is proposed, the following specifications apply. Existing roofing material asphalt shingles proposed roofing material asphalt shingles manufacturer owens corning brand and model truder duration color (if cool roof required) shasta white built-up roofing assembly system number per attached listing report (if applicable) n a specific exemption from cool roof requirements (if applicable) n a required building inspector field verification (if applicable) n a note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Residential alteration-addn | Permit status: Completed | Completion date: January 26, 2015 | Permit id: Pds2015-Resalt- | |||||
SCORE 96 15921 Wood Rock Ln Ramona Ca 92065 - 38 sqft re-roof for exising sfd if a re-roof project is proposed, the following specifications apply. Existing roofing material comp shinlges proposed roofing material comp shingles manufacturer true def brand and model duration color (if cool roof required) shasta white built-up roofing assembly system number per attached listing report (if applicable) n a specific exemption from cool roof requirements (if applicable) n a required building inspector field verification (if applicable) note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Residential alteration-addn | Permit status: Completed | Completion date: December 26, 2014 | Permit id: Pds2014-Resalt- | |||||
SCORE 96 3681 El Canto Dr Spring Valley Ca 91977 17 sf partial reroof for existing sfd. If a re-roof project is proposed, the following specifications apply. Existing roofing material comp proposed roofing material comp specific exemption from cool roof requirements (if applicable) not ducts in attic. Required building inspector field verification (if applicable) required note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Residential alteration-addn | Permit status: Completed | Completion date: January 30, 2015 | Permit id: Pds2014-Resalt- | |||||
SCORE 96 1337 Northview Dr El Cajon Ca 92019 - 40 sqft reroof for existing sfd if a re-roof project is proposed, the following specifications apply. Existing roofing material comp proposed roofing material comp manufacturer ownes brand and model trve definition durations color (if cool roof required) shasta white built-up roofing assembly system number per attached listing report (if applicable) n a specific exemption from cool roof requirements (if applicable) n a required building inspector field verification (if applicable) n a note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Residential alteration-addn | Permit status: Completed | Completion date: November 21, 2014 | Permit id: Pds2014-Resalt- | |||||
SCORE 96 2117 Elva St El Cajon Ca 92019 - 23 sqft re-roof for existing sfd. If a re-roof project is proposed, the following specifications apply. Existing roofing material tile proposed roofing material tile manufacturer boral brand and model casa grande blend color (if cool roof required) villa 9 built-up roofing assembly system number per attached listing report (if applicable) n a specific exemption from cool roof requirements (if applicable) n a required building inspector field verification (if applicable) n a note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Residential alteration-addn | Permit status: Completed | Completion date: November 21, 2014 | Permit id: Pds2014-Resalt- | |||||
SCORE 96 56 Cancha De Golf Rancho Santa Fe Ca 92067 , reroof, comp shingles slope area, 65 sf and flat 29 sf- icc #esr-1660. Reroof is for all 4 units of this condo building, addresses are 125, 127, 129, and 131 cancha de golf, (apn 302-120-22-17. 18, 19, and 20). Address assigned by county is 56 cancha de golf. If a re-roof project is proposed, the following specifications apply. Existing roofing material comp shingles proposed roofing material comp shingles slope area flat portion icc#esr 16 manufacturer owens corning brand and model thru def duration color (if cool roof required) brown wood built-up roofing assembly system number per attached listing report (if applicable) specific exemption from cool roof requirements (if applicable) install radiant barier required building inspector field verification (if applicable) install radiant barrier note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the b Permit type: Residential alteration-addn | Permit status: Completed | Completion date: November 10, 2014 | Permit id: Pds2014-Resalt- | |||||
SCORE 96 3025 Millar Ranch Rd Spring Valley Ca 91978 4400sqft re-roof () from asphalt shingles to asphalt shingles (crrc 0890-0008) class a) for existing sfd. If a re-roof project is proposed, the following specifications apply. Existing roofing material asphalt shingles proposed roofing material asphalt shingles manufacturer owens corning brand and model trudefinition duration color (if cool roof required) shasta white built-up roofing assembly system number per attached listing report (if applicable) specific exemption from cool roof requirements (if applicable) required building inspector field verification (if applicable) note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Residential alteration-addn | Permit status: Completed | Completion date: September 25, 2014 | Permit id: Pds2014-Resalt- | |||||
SCORE 96 56 Cancha De Golf Rancho Santa Fe Ca 920914428 , reroof, shingles, 10,8 sq ft, icc# esr-1372. Reroof is for all 4 units of this condo building, addresses are 225, 227, 229 and 231 via osuna, (apn 302-120-22-09,10,11,12). Address assigned by county is 56 cancha de golf. Your project may need to comply with cool roof requirements based on the 2008 building energy efficiency standards. Products required to comply must be labeled by the cool roof rating council (crrc), listed in the crrcs rated product directory (www. Coolroofs. Org), and tested for solar reflectance and thermal emittance. Your building inspector will check for compliance at inspection. Permit type: Residential alteration-addn | Permit status: Completed | Completion date: March 19, 2013 | Permit id: Pds2013-Resalt- | |||||
SCORE 96 25328 Poderio Dr Ramona Ca 92065 2700sf re-roof for existing sfd if a re-roof project is proposed, the following specifications apply. Existing roofing material conc tile proposed roofing material comp shingle manufacturer owens corning brand and model true dech color (if cool roof required) amber built-up roofing assembly system number per attached listing report (if applicable) specific exemption from cool roof requirements (if applicable) required building inspector field verification (if applicable) old roof completely removed note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Residential alteration-addn | Permit status: Completed | Completion date: July 22, 2016 | Permit id: Pds2016-Resalt- | |||||
SCORE 96 326 Paraiso Ave Spring Valley Ca 91977 23 sf re-roof for existing sfd. If a re-roof project is proposed, the following specifications apply. Existing roofing material comp proposed roofing material comp manufacturer owens-corning brand and model true def duration color (if cool roof required) amber built-up roofing assembly system number per attached listing report (if applicable) n a specific exemption from cool roof requirements (if applicable) n a crrc# = 0890-0009 required building inspector field verification (if applicable) n a note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Residential alteration-addn | Permit status: Completed | Completion date: September 25, 2015 | Permit id: Pds2015-Resalt- | |||||
SCORE 96 161 Valle De Oro Ca Res reroof () 64 sf if a re-roof project is proposed, the following specifications apply. Existing roofing material built up proposed roofing material ib roof system and gaf (for garage area ul er 1306-02) manufacturer ib roofing (ic# esr-2852) and aaf brand and model ib cool roof crrc 06640-0004. Color (if cool roof required) bright white built-up roofing assembly system number per attached listing report (if applicable) ul er 1306-02 specific exemption from cool roof requirements (if applicable) n a required building inspector field verification (if applicable) n a note self-certification for interior attic by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Residential alteration-addn | Permit status: Completed | Completion date: November 7, 2016 | Permit id: Pds2016-Resalt- | |||||
SCORE 96 3715 Putter Dr Bonita Ca 91902 Res reroof 47 sf - wooden shakes to asphalt shingles if a re-roof project is proposed, the following specifications apply. Existing roofing material wood shakes proposed roofing material asphalt shingles manufacturer owens corning brand and model trudefinition color (if cool roof required) na built-up roofing assembly system number per attached listing report (if applicable) na specific exemption from cool roof requirements (if applicable) zone 7 required building inspector field verification (if applicable) note self-certification of interior attic by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Residential alteration-addn | Permit status: Completed | Completion date: November 7, 2016 | Permit id: Pds2016-Resalt- | |||||
SCORE 96 5411 Mirar Ct Bonita Ca 91902 Wood shake to light conc. Icc#esr-19 () your project may need to comply with cool roof requirements based on the 2008 building energy efficiency standards. Products required to comply must be labeled by the cool roof rating council (crrc), listed in the crrcs rated product directory (www. Coolroofs. Org), and tested for solar reflectance and thermal emittance. Your building inspector will check for compliance at inspection. Permit type: Residential alteration-addn | Permit status: Completed | Completion date: September 29, 2015 | Permit id: Pds2013-Resalt- | |||||
SCORE 96 10321 Loma Rancho Dr Spring Valley Ca 91978 18 sf () reroof, comp to comp if a re-roof project is proposed, the following specifications apply. Existing roofing material comp proposed roofing material comp manufacturer owens corning brand and model durationtru-def color (if cool roof required) ornage amber built-up roofing assembly system number per attached listing report (if applicable) ac-438 specific exemption from cool roof requirements (if applicable) required building inspector field verification (if applicable) cool roof-0890-0009 note self-certification by a licensed contractor is acceptable for all associated interior work a if a signed letter on company letterhead is provided to the building inspector at time of inspection. Permit type: Residential alteration-addn | Permit status: Completed | Completion date: May 6, 2016 | Permit id: Pds2016-Resalt- | |||||
SCORE 96 4444 Topa Topa Dr La Mesa Ca 91941 29 sf re-roof for (e) sfd if a re-roof project is proposed, the following specifications apply. Existing roofing material asphalt shingle proposed roofing material asphalt shingle manufacturer owens corning brand and model true def color (if cool roof required) antique silver built-up roofing assembly system number per attached listing report (if applicable) specific exemption from cool roof requirements (if applicable) required building inspector field verification (if applicable) note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Residential alteration-addn | Permit status: Completed | Completion date: May 6, 2016 | Permit id: Pds2016-Resalt- | |||||
SCORE 96 12782 Jackson Hill Way El Cajon Ca 92021 Re-roof shinkle to shinkle your project may need to comply with cool roof requirements based on the 2008 building energy efficiency standards. Products required to comply must be labeled by the cool roof rating council (crrc), listed in the crrcs rated product directory (www. Coolroofs. Org), and tested for solar reflectance and thermal emittance. Your building inspector will check for compliance at inspection. Permit type: Residential alteration-addn | Permit status: Issued invalid expired | Permit id: Pds2013-Resalt- | |||||
SCORE 96 161 Valle De Oro Ca San Diego Ca Res reroof () 64 sf if a re-roof project is proposed, the following specifications apply. Existing roofing material built up proposed roofing material ib roof system and gaf (for garage area ul er 1306-02) manufacturer ib roofing (ic# esr-2852) and aaf brand and model ib cool roof crrc 06640-0004. Color (if cool roof required) bright white built-up roofing assembly system number per attached listing report (if applicable) ul er 1306-02 specific exemption from cool roof requirements (if applicable) n a required building inspector field verification (if applicable) n a note self-certification for interior attic by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Addn | Permit status: Completed | Completion date: November 7, 2016 | Permit id: Pds2016-Resalt- | |||||
SCORE 96 9837 Circa Valle Verde El Cajon Ca 92021 Re-roof if a re-roof project is proposed, the following specifications apply. Existing roofing material concrete tile proposed roofing material concrete tile manufacturer eagle brand and model capistrano color (if cool roof required) tuscan blend crrc#0918-0085 built-up roofing assembly system number per attached listing report (if applicable) n a specific exemption from cool roof requirements (if applicable) no required building inspector field verification (if applicable) yes note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Addn | Permit status: Issued | Permit id: Pds2017-Resalt- | |||||
SCORE 96 842 Ramona Ave Spring Valley Ca 91977 24 sq ft re-roof for sfd if a re-roof project is proposed, the following specifications apply. Existing roofing material shingles proposed roofing material shingles manufacturer owens corning brand and model trudefinition color (if cool roof required) na built-up roofing assembly system number per attached listing report (if applicable) na specific exemption from cool roof requirements (if applicable) no ducts in attic required building inspector field verification (if applicable) yes note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Addn | Permit status: Completed | Completion date: April 27, 2017 | Permit id: Pds2017-Resalt- | |||||
SCORE 96 1614 Woodrun Pl El Cajon Ca 92019 12 sqft re-roof if a re-roof project is proposed, the following specifications apply. Existing roofing material concrete tile proposed roofing material re-use tile & replace underlayment manufacturer n a brand and model n a color (if cool roof required) n a built-up roofing assembly system number per attached listing report (if applicable) n a specific exemption from cool roof requirements (if applicable) n a required building inspector field verification (if applicable) yes note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Addn | Permit status: Completed | Completion date: April 27, 2017 | Permit id: Pds2017-Resalt- | |||||
SCORE 96 5635 Loping Ln Bonita Ca 91902 If a re-roof project is proposed, the following specifications apply. Existing roofing material concrete tiles proposed roofing material concrete tiles manufacturer eagle brand and model ponderosa color (if cool roof required) arcadia, crrc product id#0918-0043 built-up roofing assembly system number per attached listing report (if applicable) n a specific exemption from cool roof requirements (if applicable) no required building inspector field verification (if applicable) yes note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Addn | Permit status: Completed | Completion date: July 21, 2017 | Permit id: Pds2017-Resalt- | |||||
SCORE 96 3964 Acacia Ave Bonita Ca 91902 Res re-roof if a re-roof project is proposed, the following specifications apply. Existing roofing material comp shingles proposed roofing material comp shingles manufacturer owens-corning brand and model tru-def color (if cool roof required) built-up roofing assembly system number per attached listing report (if applicable) n a specific exemption from cool roof requirements (if applicable) cz7 required building inspector field verification (if applicable) note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Addn | Permit status: Completed | Completion date: October 16, 2017 | Permit id: Pds2017-Resalt- | |||||
SCORE 96 12782 Jackson Hill Way, El Cajon, Ca 92021 Re-roof shinkle to shinkle your project may need to comply with cool roof requirements based on the 2008 building energy efficiency standards. Products required to comply must be labeled by the cool roof rating council (crrc), listed in the crrcs rated product directory (www. Coolroofs. Org), and tested for solar reflectance and thermal emittance. Your building inspector will check for compliance at inspection. Permit type: Residential alterati | Permit status: Issued | Permit id: Pds2013-Resalt- | Parcel: 400-390-11-00 | |||||
SCORE 96 56 Cancha De Golf, Rancho Santa Fe, Ca 92091 4428 Hra, reroof, shingles, 10,8 sq ft, icc# esr-1372. Reroof is for all 4 units of this condo building, addresses are 225, 227, 229 and 231 via osuna, (apn: 302-120-22-09,10,11,12). Address assigned by county is 56 cancha de golf. Your project may need to comply with cool roof requirements based on the 2008 building energy efficiency standards. Products required to comply must be labeled by the cool roof rating council (crrc), listed in the crrcs rated product directory (www. Coolroofs. Org), and tested for solar reflectance and thermal emittance. Your building inspector will check for compliance at inspection. Permit type: Residential alterati | Permit status: Completed | Permit id: Pds2013-Resalt- | Parcel: 302-120-22-09 | |||||
SCORE 96 1218 Buena Vista Ave, Spring Valley, Ca 91977 2500sf reroof for existing sfd. If a re-roof project is proposed, the following specifications apply. Existing roofing material shingles proposed roofing material shingles manufacturer owens corning brand and model tru definition duration color (if cool roof required) shasta white built-up roofing assembly system number per attached listing report (if applicable) na specific exemption from cool roof requirements (if applicable) na required building inspector field verification (if applicable) note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Misc. (antennas, tennis cts, gazebo) | Permit status: Completed | Permit id: Pds2016-Resalt- | Parcel: 5793641500 | |||||
SCORE 96 25328 Poderio Dr, Ramona, Ca 92065 2700sf re-roof for existing sfd if a re-roof project is proposed, the following specifications apply. Existing roofing material conc tile proposed roofing material comp shingle manufacturer owens corning brand and model true dech color (if cool roof required) amber built-up roofing assembly system number per attached listing report (if applicable) specific exemption from cool roof requirements (if applicable) required building inspector field verification (if applicable) old roof completely removed note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Misc. (antennas, tennis cts, gazebo) | Permit status: Issued | Permit id: Pds2016-Resalt- | Parcel: 2885812200 | |||||
SCORE 96 10321 Loma Rancho Dr, Spring Valley, Ca 91978 18 sf () reroof, comp to comp if a re-roof project is proposed, the following specifications apply. Existing roofing material comp proposed roofing material comp manufacturer owens corning brand and model durationtru-def color (if cool roof required) ornage amber built-up roofing assembly system number per attached listing report (if applicable) ac-438 specific exemption from cool roof requirements (if applicable) required building inspector field verification (if applicable) cool roof-0890-0009 note self-certification by a licensed contractor is acceptable for all associated interior work a if a signed letter on company letterhead is provided to the building inspector at time of inspection. Permit type: Misc. (antennas, tennis cts, gazebo) | Permit status: Completed | Permit id: Pds2016-Resalt- | Parcel: 5051540400 | |||||
SCORE 96 4444 Topa Topa Dr, La Mesa, Ca 91941 29 sf re-roof for (e) sfd if a re-roof project is proposed, the following specifications apply. Existing roofing material asphalt shingle proposed roofing material asphalt shingle manufacturer owens corning brand and model true def color (if cool roof required) antique silver built-up roofing assembly system number per attached listing report (if applicable) specific exemption from cool roof requirements (if applicable) required building inspector field verification (if applicable) note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Misc. (antennas, tennis cts, gazebo) | Permit status: Completed | Permit id: Pds2016-Resalt- | |||||
SCORE 96 56 Cancha De Golf, Rancho Santa Fe, Ca 920914428 , reroof, shingles, 10,8 sq ft, icc# esr-1372. Reroof is for all 4 units of this condo building, addresses are 225, 227, 229 and 231 via osuna, (apn 302-120-22-09,10,11,12). Address assigned by county is 56 cancha de golf. Your project may need to comply with cool roof requirements based on the 2008 building energy efficiency standards. Products required to comply must be labeled by the cool roof rating council (crrc), listed in the crrcs rated product directory (www. Coolroofs. Org), and tested for solar reflectance and thermal emittance. Your building inspector will check for compliance at inspection. Permit type: Misc. (antennas, tennis cts, gazebo) | Permit status: Completed | Permit id: Pds2013-Resalt- | Parcel: 3021202209 | |||||
SCORE 96 1425 Cuyamaca Ave, Spring Valley, Ca 91977 Res reroof; 1600sf if a re-roof project is proposed, the following specifications apply. Existing roofing material tile proposed roofing material comp shingles manufacturer owens corning brand and model true definition - duration (amber) color (if cool roof required) built-up roofing assembly system number per attached listing report (if applicable) specific exemption from cool roof requirements (if applicable) na required building inspector field verification (if applicable) yes note self-certification of interior attic by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Misc. (antennas, tennis cts, gazebo) | Permit status: Issued | Permit id: Pds2016-Resalt- | Parcel: 5793990400 | |||||
SCORE 96 161 Valle De Oro, Ca Res reroof () 64 sf if a re-roof project is proposed, the following specifications apply. Existing roofing material built up proposed roofing material ib roof system and gaf (for garage area ul er 1306-02) manufacturer ib roofing (ic# esr-2852) and aaf brand and model ib cool roof crrc 06640-0004. Color (if cool roof required) bright white built-up roofing assembly system number per attached listing report (if applicable) ul er 1306-02 specific exemption from cool roof requirements (if applicable) n a required building inspector field verification (if applicable) n a note self-certification for interior attic by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Misc. (antennas, tennis cts, gazebo) | Permit status: Completed | Permit id: Pds2016-Resalt- | Parcel: 2681804300 | |||||
SCORE 96 3715 Putter Dr, Bonita, Ca 91902 Res reroof 47 sf - wooden shakes to asphalt shingles if a re-roof project is proposed, the following specifications apply. Existing roofing material wood shakes proposed roofing material asphalt shingles manufacturer owens corning brand and model trudefinition color (if cool roof required) na built-up roofing assembly system number per attached listing report (if applicable) na specific exemption from cool roof requirements (if applicable) zone 7 required building inspector field verification (if applicable) note self-certification of interior attic by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Misc. (antennas, tennis cts, gazebo) | Permit status: Completed | Permit id: Pds2016-Resalt- | Parcel: 5702503100 | |||||
SCORE 96 326 Paraiso Ave, Spring Valley, Ca 91977 23 sf hra re-roof for existing sfd. If a re-roof project is proposed, the following specifications apply. Existing roofing material: comp proposed roofing material: comp manufacturer: owens-corning brand and model: true def duration color (if cool roof required): amber built-up roofing assembly system number per attached listing report (if applicable): n a specific exemption from cool roof requirements (if applicable): n a crrc# = 0890-0009 required building inspector field verification (if applicable): n a note: self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Misc. (antennas, tennis cts, gazebo) | Permit status: Completed | Permit id: Pds2015-Resalt- | Parcel: 584-582-07-00 | |||||
SCORE 96 5209 Nannette St, Bonita, Ca 91902 40 sf hra reroof for existing sfd. If a re-roof project is proposed, the following specifications apply. Existing roofing material: asphalt shingles (35 sf) and built-up (500sf) proposed roofing material: asphalt shingles (35 sf) and single-ply thermoplastic (500sf) manufacturer: shinges - owens corning, thermoplastic - duro-last brand and model: shingles - tru definition duration desert tan thermpolastic - single ply pvc color (if cool roof required): n a thermoplastic roofing assembly system number per attached listing report (if applicable): 54 specific exemption from cool roof requirements (if applicable): climate zone 7 required building inspector field verification (if applicable): n a note: self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Misc. (antennas, tennis cts, gazebo) | Permit status: Completed | Permit id: Pds2015-Resalt- | Parcel: 590-020-04-00 | |||||
SCORE 96 3352 Bonita Mesa Rd, Bonita, Ca 91902 46 sf hra reroof for existing sfd. If a re-roof project is proposed, the following specifications apply. Existing roofing material: asphalt shingles proposed roofing material: asphalt shingles manufacturer: owens-corning brand and model: trudefinition duration sierra grey color (if cool roof required): n a built-up roofing assembly system number per attached listing report (if applicable): n a specific exemption from cool roof requirements (if applicable): climate zone 7 required building inspector field verification (if applicable): n a note: self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Misc. (antennas, tennis cts, gazebo) | Permit status: Completed | Permit id: Pds2015-Resalt- | Parcel: 570-090-26-00 | |||||
SCORE 96 3338 S Bonita St, Spring Valley, Ca 91977 2600sf re-roof for existing sfd if a re-roof project is proposed, the following specifications apply. Existing roofing material: to be removed (comp shingle) proposed roofing material: comp shingle manufacturer: owens corning brand and model: oakridge color (if cool roof required): shasta white built-up roofing assembly system number per attached listing report (if applicable): specific exemption from cool roof requirements (if applicable): required building inspector field verification (if applicable): note: self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Misc. (antennas, tennis cts, gazebo) | Permit status: Completed | Permit id: Pds2015-Resalt- | Parcel: 504-093-30-00 | |||||
SCORE 96 82 Loma View Ct, Spring Valley, Ca 91977 26 sf re-roof for existing patio and sfd. If a re-roof project is proposed, the following specifications apply. Existing roofing material: tile main house built-up patio proposed roofing material: tile main house built-up patio manufacturer: eagle main house duro last patio brand and model: capistrano main house color (if cool roof required): kona red main house bright white patio built-up roofing assembly system number per attached listing report (if applicable): n a specific exemption from cool roof requirements (if applicable): n a required building inspector field verification (if applicable): n a note: self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Misc. (antennas, tennis cts, gazebo) | Permit status: Completed | Permit id: Pds2015-Resalt- | Parcel: 586-285-56-00 | |||||
SCORE 96 107 Eureka Rd, Spring Valley, Ca 91978 22 sf hra re-roof for existing sfd. If a re-roof project is proposed, the following specifications apply. Existing roofing material: asphalt shingle proposed roofing material: asphalt shingle manufacturer: owens-corning brand and model: oakridge color (if cool roof required): shasta white built-up roofing assembly system number per attached listing report (if applicable): n a specific exemption from cool roof requirements (if applicable): n a required building inspector field verification (if applicable): n a note: self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Misc. (antennas, tennis cts, gazebo) | Permit status: Completed | Permit id: Pds2015-Resalt- | Parcel: 505-164-17-00 | |||||
SCORE 96 56 Cancha De Golf, Rancho Santa Fe, Ca 92067 Hra, reroof, comp shingles slope area, 65 sf and flat 29 sf- icc #esr-1660. Reroof is for all 4 units of this condo building, addresses are 125, 127, 129, and 131 cancha de golf, (apn: 302-120-22-17. 18, 19, and 20). Address assigned by county is 56 cancha de golf. If a re-roof project is proposed, the following specifications apply. Existing roofing material: comp shingles proposed roofing material: comp shingles slope area flat portion icc#esr 1660 manufacturer: owens corning brand and model: thru def duration color (if cool roof required): brown wood built-up roofing assembly system number per attached listing report (if applicable): specific exemption from cool roof requirements (if applicable): install radiant barier required building inspector field verification (if applicable): install radiant barrier note: self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the Permit type: Misc. (antennas, tennis cts, gazebo) | Permit status: Completed | Permit id: Pds2014-Resalt- | Parcel: 302-120-22-18 | |||||
SCORE 96 3025 Millar Ranch Rd, Spring Valley, Ca 91978 4400sqft re-roof (hra) from asphalt shingles to asphalt shingles (crrc 0890-0008) class a) for existing sfd. If a re-roof project is proposed, the following specifications apply. Existing roofing material: asphalt shingles proposed roofing material: asphalt shingles manufacturer: owens corning brand and model: trudefinition duration color (if cool roof required): shasta white built-up roofing assembly system number per attached listing report (if applicable): specific exemption from cool roof requirements (if applicable): required building inspector field verification (if applicable): note: self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Misc. (antennas, tennis cts, gazebo) | Permit status: Completed | Permit id: Pds2014-Resalt- | Parcel: 596-010-67-00 | |||||
SCORE 96 5411 Mirar Ct, Bonita, Ca 91902 Wood shake to light conc. Icc#esr-19 (hra) your project may need to comply with cool roof requirements based on the 2008 building energy efficiency standards. Products required to comply must be labeled by the cool roof rating council (crrc), listed in the crrcs rated product directory (www. Coolroofs. Org), and tested for solar reflectance and thermal emittance. Your building inspector will check for compliance at inspection. Permit type: Misc. (antennas, tennis cts, gazebo) | Permit status: Completed | Permit id: Pds2013-Resalt- | Parcel: 590-241-21-00 | |||||
SCORE 96 3681 El Canto Dr, Spring Valley, Ca 91977 17 sf partial reroof for existing sfd. If a re-roof project is proposed, the following specifications apply. Existing roofing material: comp proposed roofing material: comp specific exemption from cool roof requirements (if applicable): not ducts in attic. Required building inspector field verification (if applicable): required note: self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Misc. (antennas, tennis cts, gazebo) | Permit status: Completed | Permit id: Pds2014-Resalt- | Parcel: 501-272-13-00 | |||||
SCORE 96 9164 Berkview Ln, Spring Valley, Ca 91977 2300sqft re-roof (hra) for existing sfd. If a re-roof project is proposed, the following specifications apply. Existing roofing material: asphalt shingles proposed roofing material: asphalt shingles manufacturer: owens corning brand and model: truder duration color (if cool roof required): shasta white built-up roofing assembly system number per attached listing report (if applicable): n a specific exemption from cool roof requirements (if applicable): n a required building inspector field verification (if applicable): n a note: self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Misc. (antennas, tennis cts, gazebo) | Permit status: Completed | Permit id: Pds2015-Resalt- | Parcel: 578-342-13-00 | |||||
SCORE 96 9553 Chimney Rock Ln, El Cajon, Ca 92021 2700sqft re-roof (hra) for existing sfd. If a re-roof project is proposed, the following specifications apply. Existing roofing material: concrete tile proposed roofing material: concrete tile manufacturer: eagle brand and model: capistrano color (if cool roof required): brown built-up roofing assembly system number per attached listing report (if applicable): n a specific exemption from cool roof requirements (if applicable):n a required building inspector field verification (if applicable): n a note: self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Misc. (antennas, tennis cts, gazebo) | Permit status: Completed | Permit id: Pds2015-Resalt- | Parcel: 396-080-29-00 | |||||
SCORE 96 15921 Wood Rock Ln, Ramona, Ca 92065 Hra- 38 sqft re-roof for exising sfd if a re-roof project is proposed, the following specifications apply. Existing roofing material: comp shinlges proposed roofing material: comp shingles manufacturer: true def brand and model: duration color (if cool roof required): shasta white built-up roofing assembly system number per attached listing report (if applicable): n a specific exemption from cool roof requirements (if applicable): n a required building inspector field verification (if applicable): note: self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Misc. (antennas, tennis cts, gazebo) | Permit status: Completed | Permit id: Pds2014-Resalt- | Parcel: 283-032-81-00 | |||||
SCORE 96 2117 Elva St, El Cajon, Ca 92019 Hra- 23 sqft re-roof for existing sfd. If a re-roof project is proposed, the following specifications apply. Existing roofing material: tile proposed roofing material: tile manufacturer: boral brand and model: casa grande blend color (if cool roof required): villa 900 built-up roofing assembly system number per attached listing report (if applicable): n a specific exemption from cool roof requirements (if applicable): n a required building inspector field verification (if applicable): n a note: self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Misc. (antennas, tennis cts, gazebo) | Permit status: Completed | Permit id: Pds2014-Resalt- | Parcel: 518-142-07-00 | |||||
SCORE 96 9837 Circa Valle Verde, El Cajon, Ca 92021 Re-roof if a re-roof project is proposed, the following specifications apply. Existing roofing material concrete tile proposed roofing material concrete tile manufacturer eagle brand and model capistrano color (if cool roof required) tuscan blend crrc#0918-0085 built-up roofing assembly system number per attached listing report (if applicable) n a specific exemption from cool roof requirements (if applicable) no required building inspector field verification (if applicable) yes note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Misc. (antennas, tennis cts, gazebo) | Permit status: Issued | Permit id: Pds2017-Resalt- | Parcel: 3961933000 | |||||
SCORE 96 3964 Acacia Ave, Bonita, Ca 91902 Res re-roof if a re-roof project is proposed, the following specifications apply. Existing roofing material comp shingles proposed roofing material comp shingles manufacturer owens-corning brand and model tru-def color (if cool roof required) built-up roofing assembly system number per attached listing report (if applicable) n a specific exemption from cool roof requirements (if applicable) cz7 required building inspector field verification (if applicable) note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Misc. (antennas, tennis cts, gazebo) | Permit status: Issued | Permit id: Pds2017-Resalt- | Parcel: 5930711700 | |||||
SCORE 96 5635 Loping Ln, Bonita, Ca 91902 If a re-roof project is proposed, the following specifications apply. Existing roofing material concrete tiles proposed roofing material concrete tiles manufacturer eagle brand and model ponderosa color (if cool roof required) arcadia, crrc product id#0918-0043 built-up roofing assembly system number per attached listing report (if applicable) n a specific exemption from cool roof requirements (if applicable) no required building inspector field verification (if applicable) yes note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Misc. (antennas, tennis cts, gazebo) | Permit status: Completed | Permit id: Pds2017-Resalt- | Parcel: 5903500700 | |||||
SCORE 96 1614 Woodrun Pl, El Cajon, Ca 92019 12 sqft re-roof if a re-roof project is proposed, the following specifications apply. Existing roofing material concrete tile proposed roofing material re-use tile & replace underlayment manufacturer n a brand and model n a color (if cool roof required) n a built-up roofing assembly system number per attached listing report (if applicable) n a specific exemption from cool roof requirements (if applicable) n a required building inspector field verification (if applicable) yes note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Misc. (antennas, tennis cts, gazebo) | Permit status: Completed | Permit id: Pds2017-Resalt- | Parcel: 5182023716 | |||||
SCORE 96 842 Ramona Ave, Spring Valley, Ca 91977 24 sq ft re-roof for sfd if a re-roof project is proposed, the following specifications apply. Existing roofing material shingles proposed roofing material shingles manufacturer owens corning brand and model trudefinition color (if cool roof required) na built-up roofing assembly system number per attached listing report (if applicable) na specific exemption from cool roof requirements (if applicable) no ducts in attic required building inspector field verification (if applicable) yes note self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Misc. (antennas, tennis cts, gazebo) | Permit status: Completed | Permit id: Pds2017-Resalt- | Parcel: 5843304300 | |||||
SCORE 96 161 Valle De Oro, Ca San Diego Ca Res reroof () 64 sf if a re-roof project is proposed, the following specifications apply. Existing roofing material built up proposed roofing material ib roof system and gaf (for garage area ul er 1306-02) manufacturer ib roofing (ic# esr-2852) and aaf brand and model ib cool roof crrc 06640-0004. Color (if cool roof required) bright white built-up roofing assembly system number per attached listing report (if applicable) ul er 1306-02 specific exemption from cool roof requirements (if applicable) n a required building inspector field verification (if applicable) n a note self-certification for interior attic by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Misc. (antennas, tennis cts, gazebo) | Permit status: Completed | Permit id: Pds2016-Resalt- | Parcel: 2681804300 | |||||
SCORE 96 1337 Northview Dr, El Cajon, Ca 92019 Hra- 40 sqft reroof for existing sfd if a re-roof project is proposed, the following specifications apply. Existing roofing material: comp proposed roofing material: comp manufacturer: ownes brand and model: trve definition durations color (if cool roof required): shasta white built-up roofing assembly system number per attached listing report (if applicable): n a specific exemption from cool roof requirements (if applicable): n a required building inspector field verification (if applicable): n a note: self-certification by a licensed contractor is acceptable if a signed letter on company letterhead is provided to the building inspector. Permit type: Misc. (antennas, tennis cts, gazebo) | Permit status: Completed | Permit id: Pds2014-Resalt- | Parcel: 514-030-38-00 |