SCORE 75 1997-2003 Commonweal Brighton Ma 02135 2001 comm ave. Unit 34b i ran a 60a feeder from the main metering area in the basement to the 6th floor for a panel upgrade. All tenants have is 1 20a circuit for entire apartment. Also i ran 4 circuits. 2 for a c units in bedrooms which are 15a on an afci and 2 20a circuits for kitchen outlets an Client: Reservoir Heigh | Permit type: Electrical | Current use: Other | Permit id: E255278 | Parcel: 2147483647 | |||||
SCORE 75 1997 2003 Commonwealth Av Brighton Ma 02135 2001 comm ave. Unit 34b i ran a 60a feeder from the main metering area in the basement to the 6th floor for a panel upgrade. All tenants have is 1 20a circuit for entire apartment. Also i ran 4 circuits. 2 for ac units in bedrooms which are 15a on an afci and 2 20a circuits for kitchen outlets and future dishwasher(which is boxed below the sink) installed all new panel and removed old fuse box. New circuit is run in all pipe through stairwell and changed over to flex in basement and above panel. Permit type: Electrical | Permit status: Expired | Current use: Other | Permit id: E255278 | |||||
SCORE 75 1997 2003 Commonweal Brighton Ma 02135 2001 comm ave. Unit 34b /i ran a 60a feeder from the main metering area in the basement to the 6th floor for a panel upgrade. All tenants have is 1 20a circuit for entire apartment. Also i ran 4 circuits. 2 for a/c units in bedrooms which are 15a on an afci and 2 20a circuits for kitchen outlets and future dishwasher(which is boxed below the sink) installed all new panel and removed old fuse box. New circuit is run in all pipe through stairwell and changed over to flex in basement and above panel. Permit type: Electrical | Permit status: Expired | Current use: Other | Permit id: E255278 | |||||
SCORE 75 19972003 Commonweal Brighton Ma 02135 2001 comm ave. Unit 34b i ran a 60a feeder from the main metering area in the basement to the 6th floor for a panel upgrade. All tenants have is 1 20a circuit for entire apartment. Also i ran 4 circuits. 2 for a c units in bedrooms which are 15a on an afci and 2 20a circuits for kitchen outlets and future dishwasher(which is boxed below the sink) installed all new panel and removed old fuse box. New circuit is run in all pipe through stairwell and changed over to flex in basement and above panel. Client: Reservoir Heights Condo Tr | Permit type: Electrical | Permit status: Expired | Current use: Other | Permit id: E255278 | Parcel: 2205081000 | |||||
SCORE 75 6 Albano St Roslindale Ma 02131 2nd floor bedroom hallway and bathroom rewiring includes one new 15 a circuit for bathroom hall and bedroom lighting utilized existing amp circuit dedicated for bathroom placed new 15 amp circuit on an afci in panel in basement. Installed bath fan shower light (on gfci) 3 new recess in hall way also ran a 3 wire to basement for future smoke detector updating wired in smokes in hallway and bedrooms that were accessible during remodeling. Client: Bouvier Douglas F | Permit type: Electrical | Permit status: Open | Current use: 1-2fam | Permit id: E631777 | Parcel: 1804596000 | |||||
SCORE 75 1997 2003 Commonweal Brighton Ma 2001 comm ave. Unit 34b /i ran a 60a feeder from the main metering area in the basement to the 6th floor for a panel upgrade. All tenants have is 1 20a circuit for entire apartment. Also i ran 4 circuits. 2 for a/c units in bedrooms which are 15a on an afci and 2 20a circuits for kitchen outlets and future dishwasher(which is boxed below the sink) installed all new panel and removed old fuse box. New circuit is run in all pipe through stairwell and changed over to flex in basement and above panel. Permit type: Electrical permit | Expiration date: December 21, 2013 | Current use: Other | Permit id: E255278 | |||||
SCORE 75 19972003 Commonweal Brighton Ma 2001 comm ave. Unit 34b i ran a 60a feeder from the main metering area in the basement to the 6th floor for a panel upgrade. All tenants have is 1 20a circuit for entire apartment. Also i ran 4 circuits. 2 for a c units in bedrooms which are 15a on an afci and 2 20a circuits for kitchen outlets and future dishwasher(which is boxed below the sink) installed all new panel and removed old fuse box. New circuit is run in all pipe through stairwell and changed over to flex in basement and above panel. Client: Reservoir Heights Condo Tr | Permit type: Electrical permit | Expiration date: December 21, 2013 | Current use: Other | Permit id: E255278 | Parcel: 2205081000 | |||||
SCORE 75 6 Albano St Roslindale Ma 2nd floor bedroom hallway and bathroom rewiring includes one new 15 a circuit for bathroom hall and bedroom lighting utilized existing amp circuit dedicated for bathroom placed new 15 amp circuit on an afci in panel in basement. Installed bath fan shower light (on gfci) 3 new recess in hall way also ran a 3 wire to basement for future smoke detector updating wired in smokes in hallway and bedrooms that were accessible during remodeling. Client: Bouvier Douglas F | Permit type: Electrical permit | Expiration date: March 12, 2017 | Current use: 1-2fam | Permit id: E631777 | Parcel: 1804596000 |