Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
SCORE 96 Date: June 3, 2009 Contractor: John Finnerty Client: Williamson Scottie A Booker Sulan | Permit type: Electrical permit | Permit status: Completed | Completion date: March 17, 2011 | Permit id: 212647 | |||||
SCORE 96 20406 S 13th St Philadelphia Pa 191075408 Install (9) new 6- 1500w 240v baseboard heaters on unit thermostats, one on every 3rd floor, total of (9) to keep temp. For sprinkler piping in tower to prevent freezing, as per 2005 nec (cc dist) Date: May 8, 2008 Contractor: John Finnerty Client: Chancellor Associates Lp | Permit type: Electrical permit | Permit status: Completed | Completion date: June 27, 2008 | Permit id: 150994 | |||||
SCORE 96 126 N 10th St Philadelphia Pa 191072308 Wire in hp fire pump, wire in 3 4 hp jockey pump as per 2008 nec (cc district) commercial Date: January 24, 2012 Contractor: John Finnerty Client: Chin Edwin J | Permit type: Electrical permit | Permit status: Completed | Completion date: June 28, 2012 | Permit id: 378825 | |||||
SCORE 96 2123 Delancey Pl Philadelphia Pa 191036511 Existing service is 200a 1-phase 120 240v. Rewire all rooms to 2002 nec for lights, receptacles, switches, gfci protection, arc-fault protection, dedicated circuits, 2 heaters & a c units. Date: February 2, 2007 Contractor: John Finnerty Client: Tseng Vincent Suen Mainland Geoffrey | Permit type: Electrical permit | Permit status: Completed | Completion date: August 13, 2007 | Permit id: 54533 | |||||
SCORE 96 1428 W Cumberland St Philadelphia Pa 191324020 100a service to temporary work trailer from 5 22 12 to 8 22 12 as per 2008 nec must purchase new permit after 8 22 12 (north dist) Date: May 22, 2012 Contractor: John Finnerty Client: Talford Marie | Permit type: Electrical permit | Permit status: Completed | Completion date: July 9, 2012 | Permit id: 406582 | |||||
SCORE 96 130103 Locust St Philadelphia Pa 191075405 Rewire existing service with plans provided as per 2008 nec (cc dist) Date: April 14, 2011 Contractor: John Finnerty Client: The Cove Inc | Client Company: Frank Palumbo | Permit type: Electrical permit | Permit status: Completed | Completion date: June 30, 2011 | Permit id: 334392 | |||||
SCORE 96 831 N Newkirk St Philadelphia Pa 191301707 Wire kitchen to code and install 2 lights and 2 undercab lights. Wire bathroom with gfi circuit and new ceiling light and vanity light. (cc dist) Date: March 13, 2008 Contractor: John Finnerty Client: Clarke Michael S | Permit type: Electrical permit | Permit status: Expired | Completion date: March 13, 2008 | Permit id: 138130 | |||||
SCORE 96 292735 E Victoria St Philadelphia Pa 191340000 100a service to temporary work trailer from 5 22 12 to 8 22 12 as per 2008 nec must purchase new permit after 8 22 12 (east dist)(lot) Date: May 22, 2012 Contractor: John Finnerty Client: Nello Construction Co Inc | Permit type: Electrical permit | Permit status: Expired | Completion date: May 22, 2012 | Permit id: 406574 | |||||
SCORE 96 2845 E Westmoreland St Philadelphia Pa 191345900 Install a 2 amp service & panel with a ground rod as per 2005 nec Date: December 19, 2007 Contractor: John Finnerty Client: Richmond Holdings Llc | Permit type: Electrical permit | Permit status: Completed | Completion date: April 20, 2011 | Permit id: 122055 | |||||
SCORE 96 18 W Willow Grove Ave Philadelphia Pa 191183952 Rewire tenant lights and miscellenous service as per 2005 nec (north dist) Date: September 2, 2009 Contractor: John Finnerty Client: Ron Stone Phoenixville | Permit type: Electrical permit | Permit status: Completed | Completion date: July 7, 2010 | Permit id: 233222 | |||||
SCORE 96 1206 Walnut St Philadelphia Pa 191075401 Wire in 20hp fire pump, controller, pressure maintenance pump as per 2008 nec(mixed use)(cc dist) Date: June 18, 2012 Contractor: John Finnerty Client Company: 1206 Walnut St Llc | Permit type: Electrical permit | Permit status: Completed | Completion date: July 9, 2012 | Permit id: 401326 | |||||
SCORE 96 45 N 3rd St Philadelphia Pa 191062221 Wire lighting, receptacles, feeds to machines and all other on blue prints provided per 2005 nec (cc dist) Date: November 29, 2007 Contractor: John Finnerty Client: Bedrock Old City Partnersllc | Client Company: Iron Stone | Permit type: Electrical permit | Permit status: Completed | Completion date: June 27, 2008 | Permit id: 113542 | |||||
SCORE 96 101 Walnut St Philadelphia Pa 191063011 Rewire: 2 bedrooms, kitchen living rm, dining rm, hallway, 3 baths for switches, receptacles, recessed light trims, floor receptacles, label panel, test out everything, as per 2005 nec (cc dist) Date: June 12, 2009 Contractor: John Finnerty Client: Chen Dietrich Simpkins Fiona | Permit type: Electrical permit | Permit status: Completed | Completion date: October 15, 2009 | Permit id: 216963 | |||||
SCORE 96 315 Arch St Philadelphia Pa 191061810 Heat trace plumbing in back unheated stair tower basement to 8th floors as per 2008 nec (apts) Date: October 4, 2012 Contractor: John Finnerty Client: Lesko Kenneth | Permit type: Electrical permit | Permit status: Expired | Completion date: December 5, 2012 | Permit id: 431113 | |||||
SCORE 96 39 City Ave Philadelphia Pa 191312905 Wire in electric, five pump to buildings, madison, jefferson,adams,washington (75 hp 3 phase 208v) as per plans 2008 nec (west district) Date: July 20, 2010 Contractor: John Finnerty Client: Post Presidential Propert | Permit type: Electrical permit | Permit status: Completed | Completion date: August 19, 2010 | Permit id: 281307 | |||||
SCORE 96 4328 Osage Ave Philadelphia Pa 191043906 Replace existing 8 meter service 60amp with 8 meter servcie 300amp 220v meters, no electric heat, no electric hot water heater, no electric cooking no laundry as per 2005 nec (west district) Date: July 6, 2009 Contractor: John Finnerty Client: University City | Permit type: Electrical permit | Permit status: Completed | Completion date: December 9, 2009 | Permit id: 224923 | |||||
SCORE 96 20 Poplar St Philadelphia Pa 191301427 Install 6 witches, 12 recepts, 110v sprinkler bell switche 50amp ac unt, - 110v smoke detectors, 3 exhaust fans, 2 outside lights and 100amp service as per 2005 nec (cc district) Date: July 6, 2009 Contractor: John Finnerty Client: Baxter I Partnership | Permit type: Electrical permit | Permit status: Completed | Completion date: January 20, 2011 | Permit id: 224924 | |||||
SCORE 96 Date: April 27, 2010 Contractor: John Finnerty Client: Farmbry Larry W Farmbry Deidre R | Permit type: Electrical permit | Permit status: Completed | Completion date: July 20, 2010 | Permit id: 269375 | |||||
SCORE 96 101 Walnut St Philadelphia Pa 191063011 Check all rough wiring previously installed and final out devices, change wiring to new layout (in kitchen for counter top), as per 2008 nec (cc dist) Date: February 8, 2011 Contractor: John Finnerty Permit type: Electrical permit | Permit status: Completed | Completion date: April 26, 2011 | Permit id: 313470 | |||||
SCORE 96 4401 Osage Ave Philadelphia Pa 191043917 Replace (9) meter fuses meter main breakers with new 1 amp, 9 meter main disconnect and install (9) panels and install wiring to old circuits at "j" box, off existing 4 amp main fused disconnect, as per 2005 nec (west dist) Date: May 8, 2008 Contractor: John Finnerty Client: University City Housing Co | Client Company: A Co-Partnership | Permit type: Electrical permit | Permit status: Completed | Completion date: June 27, 2008 | Permit id: 150998 | |||||
SCORE 96 1212 Ellsworth St Philadelphia Pa 191474511 Rewire building for new layout as per 2005 nec and addition to existing fire alarm system as per nfpa-72 (south dist) Date: September 2, 2009 Contractor: John Finnerty Client: Roscioli Kenneth Pannell Ellen C | Permit type: Electrical permit | Permit status: Expired | Completion date: September 2, 2009 | Permit id: 233221 | |||||
SCORE 96 23 Locust St Philadelphia Pa 191035513 Remove old feed and rotary phase changer and install new main disconnect, rotary phase changer and wiring between as per 2008 nec (cc dist) Date: March 3, 2011 Contractor: John Finnerty Permit type: Electrical permit | Permit status: Completed | Completion date: May 18, 2011 | Permit id: 326469 | |||||
SCORE 96 131416 S Howard St Philadelphia Pa 191476130 Electrical service , fire pump, rough & final wire 3rd-4th floor for lights, recpt as per blue print provided as per nec 2008. No type mi cable is to be installed on this permit (no longer ul listed). Date: December 20, 2012 Contractor: John Finnerty Client: Adamo Luigi | Permit type: Electrical permit | Permit status: Expired | Completion date: December 20, 2012 | Permit id: 440345 | |||||
SCORE 96 319 E Lehigh Ave Philadelphia Pa 191251015 Add 1 recepts off existing power in 6 rooms using wiremold (6 recepts total) as per 2005 nec (east district) Date: May 7, 2009 Contractor: John Finnerty Client: Adams Family Management I | Permit type: Electrical permit | Permit status: Completed | Completion date: December 2, 2009 | Permit id: 214588 | |||||
SCORE 96 452737 Lancaster Ave Philadelphia Pa 191314618 Install 1 amp service and meter to separate power to area in buildings existing 1 amp panel (west dist) Date: September 15, 2010 Contractor: John Finnerty Client: Haba Walnut Street Lp | Permit type: Electrical permit | Permit status: Completed | Completion date: January 20, 2011 | Permit id: 301262 | |||||
SCORE 96 122729 Christian St Philadelphia Pa 191473611 Wire 3 units and house wiring.( 3 amp svs, 4 panels, outside lts, recepts, sws, outlets.) fire alarm system (south dist) Date: January 18, 2008 Contractor: John Finnerty Client: Siligato Anthony Siligato Joseph | Permit type: Electrical permit | Permit status: Completed | Completion date: June 17, 2008 | Permit id: 120436 | |||||
SCORE 96 130103 Locust St Philadelphia Pa 191075405 Relocate switches, receptacles & lighting. Replace existing recessed lights with 2x2 lay-ins. Date: May 25, 2011 Contractor: John Finnerty Client: The Cove Inc | Client Company: Frank Palumbo | Permit type: Electrical permit | Permit status: Completed | Completion date: June 20, 2011 | Permit id: 341374 | |||||
SCORE 96 62 Ogontz Ave Philadelphia Pa 191411413 Throughout---only replacing 4 existing fire alarm bells with horn strobes, relocate 2 pull stations. Existing esl 18 panel to remain.. Certify as required by code. Date: November 25, 2009 Contractor: John Finnerty Client: Blackwell Dorothy | Permit type: Electrical permit | Permit status: Completed | Completion date: January 12, 2010 | Permit id: 250043 | |||||
SCORE 96 4923 Merion Ave Philadelphia Pa 191314610 Install overhead 1 phase 120 240v 2 amp service to building, as per 2005 nec (west dist) Date: May 8, 2008 Contractor: John Finnerty Client: T&g Real Estate Holdings | Permit type: Electrical permit | Permit status: Completed | Completion date: June 27, 2008 | Permit id: 150999 | |||||
SCORE 96 153133 Locust St Philadelphia Pa 191023721 Wire in for fire pump 75 hp blue print provided as per 2008 nec and nfpa-72 (cc dist) Date: February 4, 2011 Contractor: John Finnerty Client: M Lp | Permit type: Electrical permit | Permit status: Completed | Completion date: March 21, 2011 | Permit id: 318873 | |||||
SCORE 96 Date: March 17, 2011 Contractor: John Finnerty Client: M Lp | Permit type: Electrical permit | Permit status: Completed | Completion date: April 26, 2011 | Permit id: 330445 | |||||
SCORE 96 171418 Memphis St Philadelphia Pa 191252704 Install temp light strings per floor, through out total, temp recepts 6 per fl through out total, install 12 circuit 60amp sub-panel ec 5 total, install 4 - 250w flood lights at parking lot, 4 total (east district) Date: August 27, 2007 Contractor: John Finnerty Client: Baver Stormy L | Permit type: Electrical permit | Permit status: Expired | Completion date: August 27, 2007 | Permit id: 99198 | |||||
SCORE 96 121 W Logan St Philadelphia Pa 191443619 Replace existing 3 gang meter socket with 4 gang meter socket. All (1 amp), 1 phase 120 240v, replace existing 1 amp service feed with 2 amp service cable feeder and properly grounded, as per 2005 nec (north dist) Date: December 2, 2008 Contractor: John Finnerty Client: Poland Joseph | Permit type: Electrical permit | Permit status: Completed | Completion date: January 16, 2009 | Permit id: 190861 | |||||
SCORE 96 523 N 40th St Philadelphia Pa 191044649 Customer bought house 90% completed on renovation and had no permit when tried to complete, going through house and check or replace wiring as needed per 2008 nec (west dist) Date: August 17, 2010 Contractor: John Finnerty Client: Haba Walnut Street Lp | Permit type: Electrical permit | Permit status: Completed | Completion date: December 8, 2010 | Permit id: 296754 | |||||
SCORE 96 521 N 40th St Philadelphia Pa 191044649 Customer bought house 90% completed on renovation and had no permit when tried to complete, going through house and check or replace wiring as needed per 2008 nec (west dist) Date: August 17, 2010 Contractor: John Finnerty Client: Haba Walnut Street Lp | Permit type: Electrical permit | Permit status: Completed | Completion date: October 21, 2010 | Permit id: 296756 | |||||
SCORE 96 911 Arch St Philadelphia Pa 191072404 Wire is single phrase 15 hp fire pump, controller, single phrase 1 hp pressure maintainance pump as per 2008 nec for a mixed use (office apts) Date: May 24, 2012 Contractor: John Finnerty Client: Kao Group Limited Partner | Permit type: Electrical permit | Permit status: Completed | Completion date: June 21, 2012 | Permit id: 404699 | |||||
SCORE 96 10129 Bustleton Ave Philadelphia Pa 191163718 Install 2 amp service, check old wiring in kitchen, dining room, living room and bedrooms as per 2008 nec (east dist) Date: September 1, 2010 Contractor: John Finnerty Client: Caushi Asqeri Caushi Florika | Permit type: Electrical permit | Permit status: Expired | Completion date: September 1, 2010 | Permit id: 299263 | |||||
SCORE 96 314 Cambridge St Philadelphia Pa 191231547 Rewiring ceiling kitchen light from existing switch,run oven 50amp 240volts line,install dish washer outlet,power to gas cooktop,under cab light, wire kitchen plate heater,1 20amp,microwave line,1 quad receptacle,1 gfci receptacle,1fridge receptacle,and remove old wiring as per 2008 nec Date: December 15, 2010 Contractor: John Finnerty Client: Kennedy Maura | Permit type: Electrical permit | Permit status: Expired | Completion date: March 21, 2011 | Permit id: 316651 | |||||
SCORE 96 1525 S 61st St Philadelphia Pa 191393008 Wire in 25 hp fire pump, install new wiring from existing mete to new pump location, wire in 3 4 hp jockey pump as per 2008 nec (west district) apts (25) Date: January 24, 2012 Contractor: John Finnerty Client: N Louhr-Ii Lp | Permit type: Electrical permit | Permit status: Completed | Completion date: June 28, 2012 | Permit id: 378820 | |||||
SCORE 96 19 Bainbridge St Philadelphia Pa 191461808 Add meter and main disconnect, 1 phase, 1 amp 120 240v, disconnect and pick up sub panel going to 1st floor rear apartment, as per 2005 nec (south dist) Date: May 8, 2008 Contractor: John Finnerty Client: Moore Properties Ltd | Client Company: Best City Homes | Permit type: Electrical permit | Permit status: Completed | Completion date: June 27, 2008 | Permit id: 150997 | |||||
SCORE 96 220612 Blair St Philadelphia Pa 191252002 Total re-wire of 13 unit apartment building, install all lighting, recepts, switches as per 2002 nec , install 800amp service Date: February 9, 2007 Contractor: John Finnerty Client: Grandpa Walkers Llc | Permit type: Electrical permit | Permit status: Completed | Completion date: September 4, 2008 | Permit id: 34503 | |||||
SCORE 96 204246 Amber St Philadelphia Pa 191251933 Change of contractor to existing permit for 2nd floor 2 units wiring (no fire alarm). Common exits of 2nd floor areas (east dist) Date: November 29, 2007 Contractor: John Finnerty Client: Starlin Todd P | Permit type: Electrical permit | Permit status: Expired | Completion date: March 31, 2008 | Permit id: 113535 | |||||
SCORE 96 204246 Amber St Philadelphia Pa 191251933 This permit amends per #233221 due to incorrect address & owner. Work descrition unchanged from original permit. Date: December 29, 2009 Contractor: John Finnerty Client: Starlin Todd P | Permit type: Electrical permit | Permit status: Expired | Completion date: December 29, 2009 | Permit id: 255161 |