Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
SCORE 82 Date: July 8, 2014 Contractor: Jackson Synergy Construction Client: Jackson Synergy Construct | Permit type: Alteration permit | Permit status: Completed | Completion date: April 18, 2016 | Permit id: 547780 | |||||
SCORE 82 2018 Watkins St Philadelphia Pa 191452017 Construct a 8 x two story addition on rear of a single family dwelling. (see ap #477118 for plans) Date: June 25, 2013 Contractor: Jackson Synergy Construction Client: Claiborne James E | Permit type: Zoning permit | Permit status: Completed | Completion date: June 25, 2013 | Permit id: 479282 | |||||
SCORE 82 2018 Watkins St Philadelphia Pa 191452017 Rehab single family home and build a 8x two story addition on rear as per plans Date: June 25, 2013 Contractor: Jackson Synergy Construction Client: Claiborne James E | Permit type: Alteration permit | Permit status: Completed | Completion date: April 22, 2014 | Permit id: 477118 | |||||
SCORE 82 Date: September 3, 2013 Contractor: Jackson Synergy Construction Client: Claiborne James E | Permit type: Alteration permit | Permit status: Completed | Completion date: October 30, 2013 | Permit id: 492461 | |||||
SCORE 82 2012 Titan St Philadelphia Pa 191464334 Erection of one story addition above the existing two story attached single family dwelling. Date: May 27, 2014 Contractor: Jackson Synergy Construction Client: Evose John Devose Erica C | Permit type: Zoning permit | Permit status: Completed | Completion date: July 7, 2014 | Permit id: 529706 | |||||
SCORE 82 Date: July 14, 2014 Contractor: Jackson Synergy Construction Client: Evose John Devose Erica C | Permit type: Addition permit | Permit status: Expired | Completion date: February 29, 2016 | Permit id: 529703 | |||||
SCORE 82 2618 Sears St Philadelphia Pa 191463833 9 square feet of interior alterations & roof recover - single family dwelling - applicant agrees to limit the construction to comply with ez permit standard for interior alterations, dated jan 2011. Deviations from this standard will result in the revocation of this permit and imposition of further penalties. Separate permits required for plumbing, electric and hvac. Call inspector at district office at least 24 hours prior to starting work. The listed general contractor, jackson synergy construction llc, has no employees as per notarized letter. All sub-contractors are to be licensed in the city of philadelphia, and listed on permit. A sub-contractors list is to be given to the inspector before any work starts. Date: June 17, 2014 Contractor: Jackson Synergy Construction Client: Goodwin Jamily | Permit type: Alteration permit | Permit status: Completed | Completion date: October 5, 2015 | Permit id: 539270 | |||||
SCORE 82 9 S 12th St Philadelphia Pa 191473603 Masonry front wall - remove existing 3 story front masonry wall. Replace with new 8 inch masonry wall, (4" brick & 4" block) on existing foundation. Windows and door same location & shall comply with the 2009 international energy efficiency code, u factor of . 35, and with emergency egress standards as per irc. New door opening for 36 inch door. Horizontal reinforcement (durawall) every 24 inches. Install returns into party walls for structural connection. Flash and seal roof to new front. Install 2 x 4 frame wall, r-19 insulation and sheetrock on interior front wall for finish. No other work allowed under this permit. The listed general contractor, jackson synergy construction llc, has no employees as per notarized letter. All sub-contractors are to be licensed in the city of philadelphia, and listed on permit. A sub-contractors list is to be given to the inspector before any work starts. Date: July 23, 2014 Contractor: Jackson Synergy Construction Client: Marp Pa Llc | Permit type: Alteration permit | Permit status: Completed | Completion date: August 18, 2015 | Permit id: 551153 | |||||
SCORE 82 1922 Watkins St Philadelphia Pa 191452015 11 square feet of interior alterations & roof recover - single family dwelling - applicant agrees to limit the construction to comply with ez permit standard for interior alterations, dated jan 2011. Deviations from this standard will result in the revocation of this permit and imposition of further penalties. Separate permits required for plumbing, electric and hvac. Call inspector at district office at least 24 hours prior to starting work. The listed general contractor, jackson synergy construction llc, has no employees as per notarized letter. All sub-contractors are to be licensed in the city of philadelphia, and listed on permit. A sub-contractors list is to be given to the inspector before any work starts. Date: June 17, 2014 Contractor: Jackson Synergy Construction Client: Marp Pa Llc | Permit type: Alteration permit | Permit status: Completed | Completion date: April 18, 2016 | Permit id: 539266 | |||||
SCORE 82 Date: June 25, 2014 Contractor: Jackson Synergy Construction Client: Ellis Mccoy Ada | Permit type: Use permit | Permit status: Completed | Completion date: June 25, 2014 | Permit id: 545483 | |||||
SCORE 82 908 S 12th St Philadelphia Pa 191473603 Masonry front wall with veneer - remove existing brick front wall, 4 square feet. Frame new front wall with 2 x 6 studs and plywood sheathing. New framing to be structurally fastened to existing party walls and inspected prior to starting brickwork. Foundation wall to extend to first floor at 8 inch width. Start 4 inch brick veneer at first floor level, install brick ties every 32 inches, vertical and horizontal. Physically tie in every 4 feet at adjoining wall. Windows and door same location. Install capping, flashing and weep holes as per code requirements. Date: June 25, 2014 Contractor: Jackson Synergy Construction Client: Ellis Mccoy Ada | Permit type: Alteration permit | Permit status: Completed | Completion date: August 8, 2014 | Permit id: 545403 | |||||
SCORE 82 Date: July 1, 2014 Contractor: Jackson Synergy Construction Client: Lopez Daniel | Permit type: Alteration permit | Permit status: Completed | Completion date: September 9, 2014 | Permit id: 546742 | |||||
SCORE 82 Date: September 22, 2014 Contractor: Jackson Synergy Construction Client: Sumner Micah Sumner Celina | Permit type: Alteration permit | Permit status: Completed | Completion date: August 10, 2015 | Permit id: 563218 | |||||
SCORE 82 508 Independence St Philadelphia Pa 191260000 Alterations sheetrock flooring. Total rehab.-sfd interior alterations - single family dwelling - applicant agrees to limit the construction to comply with ez permit standard for interior alterations. Separate permits required for plumbing, electric and hvac Date: July 25, 2013 Contractor: Jackson Synergy Construction Client: Miller Frank Dempsey-Miller Kimberley | Permit type: Alteration permit | Permit status: Completed | Completion date: January 21, 2015 | Permit id: 485362 | |||||
SCORE 82 508 Independence St Philadelphia Pa 191260000 Roof repairs to comply dangerous case. New plywood sheathing and new roof covering Date: July 19, 2013 Contractor: Jackson Synergy Construction Client: Miller Frank Dempsey-Miller Kimberley | Permit type: Alteration permit | Permit status: Completed | Completion date: July 25, 2013 | Permit id: 484138 | |||||
SCORE 82 1631 S Bancroft St Philadelphia Pa 191451507 For the erection of a roof deck and roof deck access pilot house accessory to an attached single family dwelling. Size and location as shown on submitted plan. Date: September 24, 2014 Contractor: Jackson Synergy Construction Client: Jograj Courtney Jograj Sherrie | Permit type: Zoning permit | Permit status: Completed | Completion date: September 24, 2014 | Permit id: 556337 | |||||
SCORE 82 1312 S Bancroft St Philadelphia Pa 191464719 9 square feet of interior alterations - single family dwelling - applicant agrees to limit the construction to comply with ez permit standard for interior alterations, dated feb. 2007. Deviations from this standard will result in the revocation of this permit and imposition of further penalties. Licensed contractor to be listed on permit separate permits required for plumbing, electric and hvac. Call inspector at district office at least 24 hours prior to starting work. Date: July 10, 2014 Contractor: Jackson Synergy Construction Client: Fernandez-Vina Elizabeth Mussell Adam S | Permit type: Alteration permit | Permit status: Completed | Completion date: March 13, 2015 | Permit id: 548570 | |||||
SCORE 82 1631 S Bancroft St Philadelphia Pa 191451507 For the erection of a roof deck and roof deck access pilot house accessory to an attached single family dwelling; for the interior alteration per submitted plan. Separate permits required for electric; plumbing and mechanical. Date: September 24, 2014 Contractor: Jackson Synergy Construction Client: Jograj Courtney Jograj Sherrie | Permit type: Alteration permit | Permit status: Expired | Completion date: August 4, 2017 | Permit id: 556340 | |||||
SCORE 82 Date: July 3, 2014 Contractor: Jackson Synergy Construction Client: Jograj Courtney Jograj Sherrie | Permit type: Alteration permit | Permit status: Completed | Completion date: July 15, 2015 | Permit id: 547251 | |||||
SCORE 82 5042 Baltimore Ave Philadelphia Pa 191433302 Make safe permit application in response to unsafe violations. To comply violation, completed work is to be inspected and approved as an appropriate repair to each violation. No engineers report submitted. Licensed contractor to assume responsibility of work. No other work this permit. Separate permits required for renovation. Contact streets department for dumpster and or footway closure permits. Date: July 2, 2014 Contractor: Jackson Synergy Construction Client: Jones And Piner Real Esta | Permit type: Alteration permit | Permit status: Completed | Completion date: August 22, 2014 | Permit id: 546741 |