SCORE 82 1805 7th St Nw, Washington, Dc 20001 Fire water and domestic water tie ins to existing 8 inch water main at night. ![]() ![]() Client: Flippo Construction Company | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Ah1200518 |
SCORE 82 1805 7th St Nw, Washington, Dc 20001 Fire water and domestic water tie ins to existing 8 inch water main at night. ![]() ![]() Client: Flippo Construction Company | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Ah1200518 |
SCORE 82 40 4th Street Se Washington Dc 2nd - extension of permit number #pa60757: (60757r2=71142); refer to approved occupancy permit for permitted hours of work; tcp expiration date same as public space permit expiration date; flippo being treated as a utility co. Because this is a dc water various location water main replacement contract #090160; install water main,fire hydrant(s), valves, and reconnect house laterals;- 127(block) and 65 (block) galveston st sw, 159 (block)joliet st sw, 600(block) galveston st sw, 6 (block)elmira st se, 600(block) darrington st se, 6 (block)forrester st se, 4257 and 4275 (block) 6th street se, 606 and 626 (block)southern ave. Se., 2 (block) and 302 (block) atlantic st se, 401 (block)condon terr. Se., 40 (block) 4th street se.,; please read conditions. ![]() ![]() Client: Dc Water | Permit type: Excavation; water ml (trench), excavation; fire hydrant(s), excavation; multiple house connections (utility co. Only), excavation; valves (excavation) | Permit status: Permit expired | Expiration date: October 15, 2012 | Permit id: Pa60757-R2 |
SCORE 82 4401 3rd Street Se Washington Dc 2nd - extension of permit number #60959: (60959r2=71143); dc water various location water main replacement contract #6; refer to approved traffic control plan (tcp) for permitted hours of work; tcp expiration date same as public space permit expiration date; flippo construction is being treated as a utility co. Because this is a dc water small dia. Water main replacement contract #6(090160) ; install water main(s) , fire hydrant(s), valves, and reconnect house servce, etc., please read conditions. : - 44 block 3rd street se, 4 (block) atlantic ave. Se, 39 (block)1st street se, 114 (block)yuma street se, 38 (block) 2nd street se, 2 (block) wayne street se, 38 (block) 4th street se, 2 (block) mississippi ave se. ![]() ![]() Client: Dc Water | Permit type: Excavation; water ml (trench), excavation; fire hydrant(s), excavation; multiple house connections (utility co. Only), excavation; valves (excavation) | Permit status: Permit expired | Expiration date: October 15, 2012 | Permit id: Pa60959-R2 |
SCORE 82 4401 3rd Street Se Washington Dc 1st - extension of permit number #60959: (60959r1=66796); dc water various location water main replacement contract #6; refer to approved traffic control plan (tcp) for permitted hours of work; tcp expiration date same as public space permit expiration date; flippo construction is being treated as a utility co. Because this is a dc water small dia. Water main replacement contract #6(090160) ; install water main(s) , fire hydrant(s), valves, and reconnect house servce, etc., please read conditions. : - 44 block 3rd street se, 4 (block) atlantic ave. Se, 39 (block)1st street se, 114 (block)yuma street se, 38 (block) 2nd street se, 2 (block) wayne street se, 38 (block) 4th street se, 2 (block) mississippi ave se. ![]() ![]() Client: Dc Water | Permit type: Excavation; water ml (trench), excavation; fire hydrant(s), excavation; multiple house connections (utility co. Only), excavation; valves (excavation) | Permit status: Permit expired | Expiration date: April 18, 2012 | Permit id: Pa60959-R1 |
SCORE 82 18 Erie Street Se Washington Dc 1st - extension of permit number pa60268: (60268r1=66732); refer to approved traffic control plan (tcp) for permitted hours of work; tcp expiration date same as public space permit expiration date; install new 24" water main from 18th street se and erie street se to easement on private property to 24" water main on site; attached plans and conditions are part of this permit; please raed conditions. ![]() ![]() Permit type: Excavation; water ml (trench) | Permit status: Approved (pending payment | Expiration date: April 26, 2012 |
SCORE 82 40 4th Street Se Washington Dc 1st extension of permit number #pa60757: (60757r1=66532); refer to approved occupancy permit for permitted hours of work; tcp expiration date same as public space permit expiration date; flippo being treated as a utility co. Because this is a dc water various location water main replacement contract #090160; install water main,fire hydrant(s), valves, and reconnect house laterals;- 127(block) and 65 (block) galveston st sw, 159 (block)joliet st sw, 600(block) galveston st sw, 6 (block)elmira st se, 600(block) darrington st se, 6 (block)forrester st se, 4257 and 4275 (block) 6th street se, 606 and 626 (block)southern ave. Se., 2 (block) and 302 (block) atlantic st se, 401 (block)condon terr. Se., 40 (block) 4th street se.,; please read conditions. ![]() ![]() Client: Dc Water | Permit type: Excavation; water ml (trench), excavation; fire hydrant(s), excavation; multiple house connections (utility co. Only), excavation; valves (excavation) | Permit status: Permit expired | Expiration date: April 18, 2012 | Permit id: Pa60757-R1 |
SCORE 82 ![]() ![]() Permit status: Expired | Expiration date: September 30, 2011 | Permit id: Pa10024452 |
SCORE 82 ![]() ![]() Permit status: Expired | Expiration date: September 30, 2011 | Permit id: Pa10024541 |
SCORE 82 ![]() ![]() Permit status: Notpaid | Expiration date: October 31, 2011 | Permit id: 0 |
Contractor Rank | Contractor Details | Number of Projects | Avg. Project Cost | Years in Business | Photos |
---|---|---|---|---|---|
SCORE 100 | Washington Gas | 14,031 Projects | $12 Avg. Project Cost | 12 Years in Business | ![]() |
SCORE 100 | John Homick | 272 Projects | 7 Years in Business | ![]() | |
SCORE 99 | Long Fence | 547 Projects | 10 Years in Business | ![]() | |
SCORE 96 | Hanlon Design Build Hanlon Design Build | 59 Projects | $36 Avg. Project Cost | 6 Years in Business | ![]() |
SCORE 93 | Dci Dci | 501 Projects | $70 Avg. Project Cost | 5 Years in Business | ![]() |