Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
SCORE 66 1445 C St Se, Washington, Dc 20003 Three geotechnical soil borings with a truck-mounted drill rig approximately 6 inches in diameter and feet in depth. One test pit approximately 4 feet in width, 6 feet in length, and 4 feet in depth. Six environmental borings installed with a geoprobe direct-push drill approximately 2. 25 inches in diameter and 25 feet in depth. Up to three environmental borings may be converted to temporary groundwater sampling points. All well materials to be removed within 24 hours, and the borings grouted with a bentonite slurry upon completion. Date: April 30, 2014 Contractor: Ecs Capitol Ser Scott Rasmussen Client: District Of Columbia Public Schools Belilta Asfaw | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1400227 | |||||
SCORE 66 2701 Naylor Rd Se, Washington, Dc 20020 Twenty-four geotechnical soil borings with an atv- or truck-mounted drill rig by hollow-auger stem method. Four borings to a depth of feet, ten to a depth of feet, and ten to a depth of 8 feet below existing site grades. All with an approximate 6 inch diameter. Date: June 16, 2014 Contractor: Ecs Capitol Ser Scott Rasmussen Client: District Of Columbia Public Schools Ramon Santos | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1400329 | |||||
SCORE 66 2351 Raynolds Pl Se, Washington, Dc 20020 Ten geotechnical soil borings with an atv-mounted hollow stem auger drill rig. All borings approximately 6 inches in diameter and one to a depth of 15 feet, three to a depth of feet, five to a depth of 65 feet, and one to a depth of feet. Drilling activities will occur on the lot specified on this permit as well as lots 0147, 0150, 0151, 0806, 0809, and 08 of square 5742 all lots are owned by mr. Waldman. Date: April 10, 2014 Contractor: Ecs Capitol Ser Scott Rasmussen Client: Gerald Waldman | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1400228 | |||||
SCORE 66 701 Mississippi Ave Se, Washington, Dc 20032 Twenty geotechnical soil borings with a drill rig by hollow-auger stem method approximately 6 inches in diameter, ten to a depth of feet, and the remaining ten to a depth of 8 feet. 8 deep borings will be infiltration test points. All borings will be abandoned in accordance with ddoe requirements. All drill cuttings will be immediately containerized to prevent soil from migrating off the site and into the nearby waterbody. "on line" Date: February 19, 2014 Contractor: Ecs Capitol Ser Scott Rasmussen Client: Districtof Columbia Tom Engers | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1400161 | |||||
SCORE 66 901 G St Nw, Washington, Dc 20001 Six geotechnical soil borings by hollow auger stem method with a drill rig. All six soil borings are approximately 6 inches in diameter and feet in depth. Date: March 31, 2014 Contractor: Ecs Capitol Ser Scott Rasmussen Client: District Of Columbia Darryn Martin | Permit type: Miscellaneous | Permit status: Permit issued | Permit id: Sb1400211 |