SCORE

DARREN CHAPMAN

ABOUT DARREN CHAPMAN

Darren Chapman specializes in:

Darren Chapman offers services:

Based on the information received from , associated with Darren Chapman over the past .

If you are considering hiring Darren Chapman for your home renovation project, we recommend using our bidding system to get competitive quotes.




QUALITY


Darren Chapman has CheckPermit score of which places them above % of local contractors.
We usually recommend hiring a contractor with a rank of 75 or above.

ACTIVITY



AVERAGE PROJECT COST



PERMITS VALUATION



PROJECTS PER TOWN:



SERVICES
Find out the best time of the year to complete your project on a minimal budget.
Get several free quotes from best contractors in your area.

REQUEST A QUOTE
Explore CheckPermit
Our dataset includes 30 milion building permits across 4 million addresses in US.

We analyzed and ranked over 1 million home remodeling contractors based on official government sources.

Every contractor's rank is calculated based on official government records.
PROJECT IMAGES



RECENT PROJECTS


Content Date Cost Contractor Rank Address Contractor
SCORE
100
Date:  July 8, 2011
Value:   $3,000
Contractor: Darren Chapman

Client: Chapman Darren L | Permit id: 671
2011/07/08300010087 George St Arlington MaDarren Chapman
SCORE
100
Date:  January 11, 2010
Value:   $1
Contractor: Darren Chapman

Client: Hoener Clayton | Permit type: Plumbing | Current use: 1-7fam | Permit id: Pl10680 | Parcel: 1904571000
2010/01/1111002 Wayburn Rd Jamaica Plain Ma 02130Darren Chapman
SCORE
100
Date:  February 11, 2010
Contractor: Darren Chapman

Client: Crowley Sean T | Permit type: Plumbing | Current use: 1-7fam | Permit id: Pl14018 | Parcel: 2002148000
2010/02/1101008 Oriole St West Roxbury Ma 02132Darren Chapman
SCORE
100
8 Oriole St West Roxbury Ma 02132
Replace water heater.
Date:  February 11, 2010
Contractor: Darren Chapman

Client: Crowley Sean T | Permit type: Gas | Current use: 1-7fam | Permit id: G14020 | Parcel: 2002148000
2010/02/1101008 Oriole St West Roxbury Ma 02132Darren Chapman
SCORE
100
40 Bourne St Jamaica Plain Ma 02130
Install new (nat. Grid freedom boiler # fcm120m - sidewall vented) boiler permit for gas piping and proper flue venting
Date:  April 1, 2010
Value:   $3,000
Contractor: Darren Chapman

Client: Knopf-Goldner M | Permit type: Gas | Current use: 1-2fam | Permit id: G19773 | Parcel: 1904531000
2010/04/01300010040 Bourne St Jamaica Plain Ma 02130Darren Chapman
SCORE
100
24 Westglow St Boston Ma 02122
Replace failed (chimney vented) water heater ruud 40 gallon gas
Date:  April 1, 2010
Value:   $800
Contractor: Darren Chapman

Client: Dutzik Anthony & Elise Henricks | Permit type: Plumbing | Current use: 1-2fam | Permit id: Pl19533 | Parcel: 1602047000
2010/04/0180010024 Westglow St Boston Ma 02122Darren Chapman
SCORE
100
40 Bourne St Jamaica Plain Ma 02130
Install boiler (watts) 911 valve & install an indirect fired (lochinvar sss051) water heater
Date:  April 1, 2010
Value:   $3,000
Contractor: Darren Chapman

Client: Knopf-Goldner M | Permit type: Plumbing | Current use: 1unit | Permit id: Pl19769 | Parcel: 1904531000
2010/04/01300010040 Bourne St Jamaica Plain Ma 02130Darren Chapman
SCORE
100
30 Mendum St Roslindale Ma 02131
Pipe in a new gas fireplace
Date:  April 27, 2010
Value:   $1,000
Contractor: Darren Chapman

Client: Glidden Kenneth | Permit type: Gas | Current use: 1-2fam | Permit id: G23291 | Parcel: 2005333000
2010/04/27100010030 Mendum St Roslindale Ma 02131Darren Chapman
SCORE
100
11 Rhoda St West Roxbury Ma 02132
Repalce failed gas furnace new condensing 90% lennox g61mpv-36b-071 furnace (70 000btu input)
Date:  April 27, 2010
Value:   $4,500
Contractor: Darren Chapman

Client: Moran Jennifer | Permit type: Gas | Current use: 1-2fam | Permit id: G22544 | Parcel: 2005703000
2010/04/27450010011 Rhoda St West Roxbury Ma 02132Darren Chapman
SCORE
100
632 W Roxbury Pk West Roxbury Ma 02132
Replace exisitng boiler with new lochinvar kbn151 (151 000mbh input) side wall vented - condesning modulating hydronic boiler
Date:  October 7, 2010
Value:   $9,000
Contractor: Darren Chapman

Permit type: Gas | Current use: 1-2fam | Permit id: G45131
2010/10/079000100632 W Roxbury Pk West Roxbury Ma 02132Darren Chapman
SCORE
100
57 Burroughs St Jamaica Plain Ma 02130
Install new watts 911 backflow device for new boiler installation (see gas permit) also install new lochinvar sit040indirect fired domestic hot water heater
Date:  February 18, 2011
Value:   $500
Contractor: Darren Chapman

Client: Elliott William | Permit type: Plumbing | Current use: 1-2fam | Permit id: Pl64645 | Parcel: 1901913004
2011/02/1850010057 Burroughs St Jamaica Plain Ma 02130Darren Chapman
SCORE
100
57 Burroughs St Jamaica Plain Ma 02130
Replace existing atmospheric gas boiler with new high effeciency lochinvar kbn151 90% effecient boiler - side wall vented
Date:  February 18, 2011
Value:   $8,000
Contractor: Darren Chapman

Client: Elliott William | Permit type: Gas | Permit status: Expired | Current use: 1-2fam | Permit id: G64649 | Parcel: 1901913004
2011/02/18800010057 Burroughs St Jamaica Plain Ma 02130Darren Chapman
SCORE
100
8 Rutland Sq Roxbury Ma 02118
Gas fitting nipples valve etc for new furnace installation (replacement) installing lennox ml180-090p48b... 90mbh input furnace
Date:  April 14, 2011
Value:   $250
Contractor: Darren Chapman

Client: Morrison Steven | Permit type: Gas | Current use: 1-4fam | Permit id: G72025 | Parcel: 402717010
2011/04/142501008 Rutland Sq Roxbury Ma 02118Darren Chapman
SCORE
100
25 Holbrook St Jamaica Plain Ma 02130
Remove old oil fired furnace and install new 97% high effeciency lennox furnace. Install lennox slp98uh090v48c - 90 000 btu
Date:  September 6, 2011
Value:   $8,000
Contractor: Darren Chapman

Client: Frank Eric | Permit type: Gas | Permit status: Expired | Current use: 1-2fam | Permit id: G91739 | Parcel: 1901792000
2011/09/06800010025 Holbrook St Jamaica Plain Ma 02130Darren Chapman
SCORE
100
186 W Brookline St Roxbury Ma 02118
Replace old rooftop unit with new 90 000mbh unput lennox 15gcsxav-36-090 rooftop heat cool unit
Date:  September 15, 2011
Value:   $3,500
Contractor: Darren Chapman

Client: Minturn Robert B Jr | Permit type: Gas | Permit status: Expired | Current use: 1-2fam | Permit id: G92552 | Parcel: 0400524000
2011/09/153500100186 W Brookline St Roxbury Ma 02118Darren Chapman
SCORE
100
15 Zamora St Jamaica Plain Ma 02130
Replace old chimney vented furnace with new pvc / direct vented lennox furnace - model el195uh135xe60d ... 135mbh input
Date:  October 18, 2011
Value:   $4,000
Contractor: Darren Chapman

Client: Smith Floria W | Permit type: Gas | Permit status: Expired | Current use: 1-2fam | Permit id: G98649 | Parcel: 1002192000
2011/10/18400010015 Zamora St Jamaica Plain Ma 02130Darren Chapman
SCORE
100
27 Sunnyside St Jamaica Plain Ma 02130
Repalce old chimney vented furnace with new lennox slp98uh090v48c side wall vented 90% high effeceincy gas furnace. 90mbh input
Date:  October 18, 2011
Value:   $5,000
Contractor: Darren Chapman

Client: Cape Edmund | Permit type: Gas | Current use: 1-2fam | Permit id: G99872 | Parcel: 1001966000
2011/10/18500010027 Sunnyside St Jamaica Plain Ma 02130Darren Chapman
SCORE
100
29 Aldworth St Jamaica Plain Ma 02130
Replace two very old oil fired gurney hydronic boilers. Replace with 2 new lochinvar kbn151 94% side wall vented hydronic boilers. - related gas fitting... 2 ea. @ 151 000 input
Date:  November 9, 2011
Value:   $15,000
Contractor: Darren Chapman

Client: Fay John J Jr | Permit type: Gas | Permit status: Expired | Current use: 1-2fam | Permit id: G103481 | Parcel: 1901725000
2011/11/091500010029 Aldworth St Jamaica Plain Ma 02130Darren Chapman
SCORE
100
29 Aldworth St Jamaica Plain Ma 02130
Install two new lochinvar sit040 indirect fired ss water heaters (with two safety mix valves) as part of boiler installation listed on app# g103481
Date:  November 9, 2011
Value:   $5,000
Contractor: Darren Chapman

Client: Fay John J Jr | Permit type: Plumbing | Permit status: Expired | Current use: 1-2fam | Permit id: Pl103485 | Parcel: 1901725000
2011/11/09500010029 Aldworth St Jamaica Plain Ma 02130Darren Chapman
SCORE
100
620 E Sixth St South Boston Ma 02127
Replace existing boiler with new lochinvar kbn106 high effeciency gas boiler. Include a lochinvar sit030 indirect fired domestic hot water heater adn safety mix valve. Minor water piping to accomodate this new water heater and boiler backflow preventer (watts 911)
Date:  August 30, 2012
Value:   $1,500
Contractor: Darren Chapman

Client: Morgan Joan F | Permit type: Plumbing | Current use: 1-2fam | Permit id: Pl174589 | Parcel: 602436000
2012/08/301500100620 E Sixth St South Boston Ma 02127Darren Chapman
SCORE
100
450 Walk Hill St Dorchester Ma 02126
Install water heater and modified piping for new lochinvar sit040 40 gallon indirect hot watewr heater. Install watts 911s backflow boielr feed device for new lochinvar whn110 gas boiler
Date:  November 12, 2012
Value:   $1,500
Contractor: Darren Chapman

Permit type: Plumbing | Current use: 1-2fam | Permit id: Pl181199
2012/11/121500100450 Walk Hill St Dorchester Ma 02126Darren Chapman
SCORE
100
450 Walk Hill St Dorchester Ma 02126
Remove and dispose of failed trianco heatmaker boiler and indirect glass lined hot water heater. Install a new lochinvar whn110 (110 00 btu input) high effeciency - side wall vented boiler and matching stianless steel indirect water heater model number sit040 - 40 gallon indirect
Date:  November 12, 2012
Value:   $1,500
Contractor: Darren Chapman

Permit type: Gas | Current use: 1-2fam | Permit id: G181198
2012/11/121500100450 Walk Hill St Dorchester Ma 02126Darren Chapman
SCORE
100
50 Garden St Boston Ma 02114
1)run new gas service from existing meter location at front of property down a long outdoor corridor to a new boiler room space at rear of building. Total developed length approx. 100 feet - using 1-1 4 sched 40 steel 2)connect new gas line to a new lochivnar kbn211 condensing modulating high e
Date:  January 22, 2013
Value:   $3,500
Contractor: Darren Chapman

Client: Pci Management Llc | Permit type: Gas | Current use: 1-4fam | Permit id: G200135 | Parcel: 502152000
2013/01/22350010050 Garden St Boston Ma 02114Darren Chapman
SCORE
100
1960 Commonwealth Av Brighton Ma 02135
Repalce failed furnace with new lennoxml180uh070e36b chimney vented (80% category i) furnace
Date:  March 27, 2013
Value:   $4,500
Contractor: Darren Chapman

Permit type: Gas | Current use: Multi | Permit id: G230333
2013/03/2745001001960 Commonwealth Av Brighton Ma 02135Darren Chapman
SCORE
100
143 Perham St West Roxbury Ma 02132
Rough in for basment bath group and laundry. Also replace chimney vented gas water heater with 60 gallon indirect fired stainless steel water heater
Date:  June 27, 2013
Value:   $1,000
Contractor: Darren Chapman

Client: Sullivan Richar | Permit type: Plumbing | Current use: 1-2fam | Permit id: Pl230141 | Parcel: 2008271000
2013/06/271000100143 Perham St West Roxbury Ma 02132Darren Chapman
SCORE
100
143 Perham St West Roxbury Ma 02132
Remove existing chimney vented boiler. Install new lochinvar kbn151 side wall vented category iv 95% high effeciency ss gas boiler
Date:  July 9, 2013
Value:   $5,000
Contractor: Darren Chapman

Client: Sullivan Richar | Permit type: Gas | Current use: 1-2fam | Permit id: G230152 | Parcel: 2008271000
2013/07/095000100143 Perham St West Roxbury Ma 02132Darren Chapman
SCORE
100
9 Concord Sq Roxbury Ma 02118
Replace failed burnham boiler with new lochinvar kbn211 boiler and also install new lochinvar sit080 indirect fired domestic hot water heater
Date:  August 15, 2013
Value:   $1,500
Contractor: Darren Chapman

Client: 9 Concord Sq Condo Trust | Permit type: Gas | Permit status: Expired | Current use: 1-4fam | Permit id: G274907 | Parcel: 0402665000
2013/08/1515001009 Concord Sq Roxbury Ma 02118Darren Chapman
SCORE
100
107 Greaton Rd West Roxbury Ma 02132
Remove and dispose of old cast iron gas converted chimney vented boiler. Supply and install a new lochinvar kbn151 (150 000 btu input) gas high effeciency side wall vented boiler - with a new lochinvar sit040 - 40 gallon ss indirect fired domestic hot water heater
Date:  August 15, 2013
Value:   $500
Contractor: Darren Chapman

Client: Herring Nancy | Permit type: Gas | Current use: 1-2fam | Permit id: G262993 | Parcel: 2006123000
2013/08/15500100107 Greaton Rd West Roxbury Ma 02132Darren Chapman
SCORE
100
107 Greaton Rd West Roxbury Ma 02132
Plumbing permit for minor water piping to backflow preventer for boielr and water piping for indirect fired water heater
Date:  August 15, 2013
Value:   $1,500
Contractor: Darren Chapman

Client: Herring Nancy | Permit type: Plumbing | Current use: 1-2fam | Permit id: Pl262994 | Parcel: 2006123000
2013/08/151500100107 Greaton Rd West Roxbury Ma 02132Darren Chapman
SCORE
100
16-24 Union Park St Roxbury Ma 02118
Remove and dispose of existing weil mclain chimney vented atmospheric gas boiler. Install a new lochinvar kbn211 (210 00 btu input) high effeceincy gas boiler. Line chimney with approved fas n seal ss chimney liner (3) also install a lochinvar sit080 80 gallon ss indirect fired domestic hot wat
Date:  August 15, 2013
Value:   $1,500
Contractor: Darren Chapman

Client: Deluca Patricia J | Permit type: Gas | Current use: 1-4fam | Permit id: G262657 | Parcel: 305961000
2013/08/15150010016-24 Union Park St Roxbury Ma 02118Darren Chapman
SCORE
100
16-24 Union Park St Roxbury Ma 02118
Install new lochinvar sit080 - 80 gallon ss indirect water heater (along with new boiler and new boiler watts 911 backflow device
Date:  August 15, 2013
Value:   $4,000
Contractor: Darren Chapman

Client: Deluca Patricia J | Permit type: Plumbing | Current use: 1-4fam | Permit id: Pl262679 | Parcel: 305961000
2013/08/15400010016-24 Union Park St Roxbury Ma 02118Darren Chapman
SCORE
100
9 Concord Sq Roxbury Ma 02118
Remove and dispose of failed burnham boiler (backflow preventer) and obsolete rheem water heater - install new lochinvar kbn211 boiler and lochinvar sit080 - indirect water heater (permit for watts backflo boielr feeder and water piping indirect water heater)
Date:  August 16, 2013
Value:   $5,000
Contractor: Darren Chapman

Client: 9 Concord Sq Condo Trust | Permit type: Plumbing | Permit status: Expired | Current use: 1-4fam | Permit id: Pl274915 | Parcel: 0402665000
2013/08/1650001009 Concord Sq Roxbury Ma 02118Darren Chapman
SCORE
100
13-15 Worcester Sq Roxbury Ma 02118
Remove and dispose of two existing atmospheric gas boilers (burnham) supply and install two new lochivnar kbn286 boilers with two new sit080 indirect fired domestic hot water heaters... Include twin stainless steel chimney liners (one for each boiler) total gas input = 572 000 btus
Date:  August 16, 2013
Value:   $1,500
Contractor: Darren Chapman

Client: 13-15 Worcester Sq Inc Llc | Permit type: Gas | Current use: 1-4fam | Permit id: G275508 | Parcel: 801510010
2013/08/16150010013-15 Worcester Sq Roxbury Ma 02118Darren Chapman
SCORE
100
13-15 Worcester Sq Roxbury Ma 02118
As part of boiler replacemnt efforts... Replace two existing chimney vent 75 gallon water heaters and install twin lochinvar sit080 ss indirect fired water heaters and related water piping
Date:  August 16, 2013
Value:   $7,500
Contractor: Darren Chapman

Client: 13-15 Worcester Sq Inc Llc | Permit type: Plumbing | Current use: 1-4fam | Permit id: Pl275579 | Parcel: 801510010
2013/08/16750010013-15 Worcester Sq Roxbury Ma 02118Darren Chapman
SCORE
100
995 Centre St Jamaica Plain Ma 02130
Add new natural gas services and install a new lochinvar kbn151 high effeciency gas boiler (side wall vented) - also see plumbing permit for boiler backflow device and a lochinvar sit080 - 80 gallon indirect fired domestic hot water heater
Date:  October 7, 2013
Value:   $10,000
Contractor: Darren Chapman

Client: Doty Constance | Permit type: Gas | Permit status: Expired | Current use: 1-2fam | Permit id: G291699 | Parcel: 1902502010
2013/10/0710000100995 Centre St Jamaica Plain Ma 02130Darren Chapman
SCORE
100
995 Centre St Jamaica Plain Ma 02130
Install new lochinvar kbn151 high effeciency gas boiler (watts 911 backflow device) and water piping to and from new lochinvar sit080 - 80 gallon ss indirect fired domestic hot water heater
Date:  October 10, 2013
Value:   $5,000
Contractor: Darren Chapman

Client: Doty Constance | Permit type: Plumbing | Permit status: Expired | Current use: 1-2fam | Permit id: Pl291704 | Parcel: 1902502010
2013/10/105000100995 Centre St Jamaica Plain Ma 02130Darren Chapman
SCORE
100
50 Monmouth St East Boston Ma 02128
Install two indirect fired water heaters and two boielr backflow devices
Date:  October 10, 2013
Value:   $5,000
Contractor: Darren Chapman

Client: Bonney | Permit type: Plumbing | Current use: 1-2fam | Permit id: Pl291752 | Parcel: 102751000
2013/10/10500010050 Monmouth St East Boston Ma 02128Darren Chapman
SCORE
100
50 Monmouth St East Boston Ma 02128
Two new lohcinvar high effeciency - side wall vented gas boilers. First floor to recieve a lochinvar kbn106 (106 000 btu input) boiler. Second floor to recieve a lochinvar kbn151 (151 000 btu input) boiler.
Date:  October 10, 2013
Value:   $10,000
Contractor: Darren Chapman

Client: Bonney | Permit type: Gas | Current use: 1-2fam | Permit id: G291737 | Parcel: 102751000
2013/10/101000010050 Monmouth St East Boston Ma 02128Darren Chapman
SCORE
100
86 Moss Hill Rd Jamaica Plain Ma 02130
Permit for new boiler backflow device (watts 911) and for new indirect fired domestic hot water heater
Date:  October 24, 2013
Value:   $1,500
Contractor: Darren Chapman

Client: Durrane Walter | Permit type: Plumbing | Current use: 1-2fam | Permit id: Pl295325 | Parcel: 1902475000
2013/10/24150010086 Moss Hill Rd Jamaica Plain Ma 02130Darren Chapman
SCORE
100
86 Moss Hill Rd Jamaica Plain Ma 02130
Remove and dispose of failed cast iron chimney vented boiler. Supply and install a new lochivnar kbn151 (151 000 btu input) high effeciency side wall vented boiler. See alos plumbing permit for backflow device and lochivnar sit040 - 40 gallon ss indirect fired domestic hot water heater
Date:  October 24, 2013
Value:   $1,500
Contractor: Darren Chapman

Client: Durrane Walter | Permit type: Gas | Permit status: Expired | Current use: 1-2fam | Permit id: G295319 | Parcel: 1902475000
2013/10/24150010086 Moss Hill Rd Jamaica Plain Ma 02130Darren Chapman
SCORE
100
120 Salem St Boston Ma 02113
Replace failed gas boiler with new twin new lochivar kbn151 (151 000 btu input) high effeceincy boilers. New boilers to be properly vented via twin new 3 ss chimney liners (liners by billy sweet chimney sweeps)
Date:  January 13, 2014
Value:   $2,500
Contractor: Darren Chapman

Client: 120 Salem Realty Trust | Permit type: Gas | Current use: Mixed | Permit id: G318444 | Parcel: 301335000
2014/01/132500100120 Salem St Boston Ma 02113Darren Chapman
SCORE
100
120 Salem St Boston Ma 02113
Plumbing pemrit for twin new lochinvar boilers - backflow preventer and 119 gallon ss indirect water heater
Date:  January 14, 2014
Value:   $5,500
Contractor: Darren Chapman

Client: 120 Salem Realty Trust | Permit type: Plumbing | Current use: Mixed | Permit id: Pl318447 | Parcel: 301335000
2014/01/145500100120 Salem St Boston Ma 02113Darren Chapman
SCORE
100
80-82 A St South Boston Ma 02127
Address we have is 52 athens st #4 per richard chung (it person @ isd) use 80a st as athens ais on corner with a st.... Remove existing weather king furnace - install new 95% afue lennox gas furnace (45mbh input) - sidewall vented direct vent appliance
Date:  January 22, 2014
Value:   $5,500
Contractor: Darren Chapman

Client: 80 A St Condo | Permit type: Gas | Current use: Multi | Permit id: G319153 | Parcel: 601197010
2014/01/22550010080-82 A St South Boston Ma 02127Darren Chapman
SCORE
100
138-144 Lincoln St Boston Ma 02111
Install new furnace - lennox ml180uh110p48c - chimney vented 80% unit for the fifth floor living space. Also install lennox ml180uh110p48c furnace for the sixth floor living space.
Date:  February 6, 2014
Value:   $15,000
Contractor: Darren Chapman

Client: Rosenberg Lewis | Permit type: Gas | Current use: 1-4fam | Permit id: G315878 | Parcel: 304329000
2014/02/0615000100138-144 Lincoln St Boston Ma 02111Darren Chapman
SCORE
100
31 Parkton Rd Jamaica Plain Ma 02130
Delete existing steam boiler and steam piping infrastructure. Supply and install a new lennox el195uh070xe36b (70 000 btu input) gas furnace - side wall vented...
Date:  February 26, 2014
Value:   $6,500
Contractor: Darren Chapman

Client: Moynihan John | Permit type: Gas | Permit status: Expired | Current use: 1-3fam | Permit id: G322097 | Parcel: 1002126000
2014/02/26650010031 Parkton Rd Jamaica Plain Ma 02130Darren Chapman
SCORE
100
67-69 Brookley Rd Jamaica Plain Ma 02130
Remove and dispose of four chimney vented domestic hot water heaters. Supply and install four - lochinvar sit040 - 40 gallon indirect fired ss water heaters. Also see gas permit fro four lochihnvar boilers - kbn081 - 81 000 btus each (plumbing permit for four watts 911 backflow devices one for eac
Date:  March 18, 2014
Value:   $10,000
Contractor: Darren Chapman

Client: Blake Peter | Permit type: Plumbing | Current use: 1-4fam | Permit id: Pl343610 | Parcel: 1102684000
2014/03/181000010067-69 Brookley Rd Jamaica Plain Ma 02130Darren Chapman
SCORE
100
67-69 Brookley Rd Jamaica Plain Ma 02130
Gas permit for four lochinvar kbn081 (81 000 btus input each. Replace four old cast iron chimney vented small boilers and install new sidewall vented high effeceincy boilers and four lochivnar sit040 (40 gallon) indirect water heaters (see also plumbing permit app # pl343610 fro water heater and boi
Date:  March 18, 2014
Value:   $20,000
Contractor: Darren Chapman

Client: Blake Peter | Permit type: Gas | Current use: 1-4fam | Permit id: G343618 | Parcel: 1102684000
2014/03/182000010067-69 Brookley Rd Jamaica Plain Ma 02130Darren Chapman
SCORE
100
228-230 Beacon St Boston Ma 02116
Please note that work is at 230 beacon st - computer did not allow #230 beacon used 232 replace old cast iron boiler with new lochinvar ftxl high efficiency boiler. Boiler is to be vented to roof via ss (fas n seal) approved flue piping system. Gas infrastructure (for old boiler) already i
Date:  September 22, 2014
Value:   $15,000
Contractor: Darren Chapman

Client: Beacon Waterside Condo | Permit type: Gas | Current use: 1-4fam | Permit id: G408727 | Parcel: 502624000
2014/09/2215000100228-230 Beacon St Boston Ma 02116Darren Chapman
SCORE
100
760 Tremont St Roxbury Ma 02118
Install new lochinvar ss indirect water heater model; sit030 - 30 gallon unit also install watts 911s combination fill and backflow device for new boiler feed
Date:  December 18, 2014
Contractor: Darren Chapman

Client: 760 Tremont St Condo Assoc | Permit type: Plumbing | Current use: 1-4fam | Permit id: Pl434111 | Parcel: 900679000
2014/12/180100760 Tremont St Roxbury Ma 02118Darren Chapman
SCORE
100
760 Tremont St Roxbury Ma 02118
Install new lennox gwm-100ie -100 000 btu sidewall vented boiler with an indirect fired ss water heater
Date:  December 18, 2014
Value:   $550
Contractor: Darren Chapman

Client: 760 Tremont St Condo Assoc | Permit type: Gas | Current use: 1-4fam | Permit id: G434109 | Parcel: 900679000
2014/12/18550100760 Tremont St Roxbury Ma 02118Darren Chapman
SCORE
100
8 Oriole St Roxbury Ma 02132
Replace water heater.
Date:  February 11, 2010
Contractor: Darren Chapman

Permit type: Gas | Permit status: Expired | Current use: 1-7fam | Permit id: G14020 | Parcel: 2002148000
2010/02/1101008 Oriole St Roxbury Ma 02132Darren Chapman
SCORE
100
11 Rhoda St Roxbury Ma 02132
Repalce failed gas furnace new condensing 90% lennox g61mpv-36b-071 furnace ( 000btu input)
Date:  April 27, 2010
Value:   $4,500
Contractor: Darren Chapman

Permit type: Gas | Permit status: Expired | Current use: 1-2fam | Permit id: G22544 | Parcel: 2005703000
2010/04/27450010011 Rhoda St Roxbury Ma 02132Darren Chapman
SCORE
100
6 Brigham St Boston Ma 02128
Repalce water heater with new ruud pvp side wall vented gallon wh
Date:  February 9, 2011
Value:   $1,200
Contractor: Darren Chapman

Permit type: Plumbing | Permit status: Expired | Current use: 1-3fam | Permit id: Pl63283 | Parcel: 0104600000
2011/02/0912001006 Brigham St Boston Ma 02128Darren Chapman
SCORE
100
6 Brigham St Boston Ma 02128
Repalce old atmospheric furnace with new lennox g61mpv-60c-091 side wall / direct vented condensing furnace
Date:  February 9, 2011
Value:   $5,000
Contractor: Darren Chapman

Permit type: Gas | Permit status: Expired | Current use: 1-3fam | Permit id: G63282 | Parcel: 0104600000
2011/02/0950001006 Brigham St Boston Ma 02128Darren Chapman
SCORE
100
632 W Roxbury Pk Roxbury Ma 02132
Replace exisitng boiler with new lochinvar kbn151 (151 000mbh input) side wall vented - condesning / modulating hydronic boiler
Date:  October 7, 2010
Value:   $9,000
Contractor: Darren Chapman

Permit type: Gas | Permit status: Expired | Current use: 1-2fam | Permit id: G45131
2010/10/079000100632 W Roxbury Pk Roxbury Ma 02132Darren Chapman
SCORE
100
Bourne St Jamaica Plain Ma 02130
Install boiler (watts) 911 valve & install an indirect fired (lochinvar sss051) water heater
Date:  April 1, 2010
Value:   $3,000
Contractor: Darren Chapman

Permit type: Plumbing | Permit status: Expired | Current use: 1unit | Permit id: Pl19769 | Parcel: 1904531000
2010/04/013000100Bourne St Jamaica Plain Ma 02130Darren Chapman
SCORE
100
8 Oriole St Roxbury Ma 02132
Replace 1 fixture.
Date:  February 11, 2010
Contractor: Darren Chapman

Permit type: Plumbing | Permit status: Expired | Current use: 1-7fam | Permit id: Pl14018 | Parcel: 2002148000
2010/02/1101008 Oriole St Roxbury Ma 02132Darren Chapman
SCORE
100
Bourne St Jamaica Plain Ma 02130
Install new (nat. Grid / freedom boiler # fcm120m - sidewall vented) boiler permit for gas piping and proper flue venting
Date:  April 1, 2010
Value:   $3,000
Contractor: Darren Chapman

Permit type: Gas | Permit status: Expired | Current use: 1-2fam | Permit id: G19773 | Parcel: 1904531000
2010/04/013000100Bourne St Jamaica Plain Ma 02130Darren Chapman
SCORE
100
6 E Sixth St Boston Ma 02127
Replace existing boiler with new lochinvar kbn106 high effeciency gas boiler. Include a lochinvar sit0 indirect fired domestic hot water heater adn safety mix valve. Minor water piping to accomodate this new water heater and boiler backflow preventer (watts 911)
Date:  August 30, 2012
Value:   $1,500
Contractor: Darren Chapman

Permit type: Plumbing | Permit status: Expired | Current use: 1-2fam | Permit id: Pl174589 | Parcel: 0602436000
2012/08/3015001006 E Sixth St Boston Ma 02127Darren Chapman
SCORE
100
663a E Fifth St Boston Ma 02127
Correct pvc flue piping that is not per code or manufacturers specifications
Date:  October 31, 2012
Value:   $3,600
Contractor: Darren Chapman

Permit type: Gas | Permit status: Expired | Current use: 1-3fam | Permit id: G189931
2012/10/313600100663a E Fifth St Boston Ma 02127Darren Chapman
SCORE
100
143 Perham St Roxbury Ma 02132
Rough in for basment bath group and laundry. Also replace chimney vented gas water heater with gallon indirect fired stainless steel water heater
Date:  June 27, 2013
Value:   $1,000
Contractor: Darren Chapman

Permit type: Plumbing | Permit status: Expired | Current use: 1-2fam | Permit id: Pl230141 | Parcel: 2008271000
2013/06/271000100143 Perham St Roxbury Ma 02132Darren Chapman
SCORE
100
143 Perham St Roxbury Ma 02132
Remove existing chimney vented boiler. Install new lochinvar kbn151 side wall vented category iv 95% high effeciency ss gas boiler
Date:  July 9, 2013
Value:   $5,000
Contractor: Darren Chapman

Permit type: Gas | Permit status: Expired | Current use: 1-2fam | Permit id: G230152 | Parcel: 2008271000
2013/07/095000100143 Perham St Roxbury Ma 02132Darren Chapman
SCORE
100
107 Greaton Rd Roxbury Ma 02132
Remove and dispose of old cast iron gas converted chimney vented boiler. Supply and install a new lochinvar kbn151 (1 0 btu input) gas / high effeciency side wall vented boiler - with a new lochinvar sit0 - gallon ss indirect fired domestic hot water heater
Date:  August 15, 2013
Value:   $500
Contractor: Darren Chapman

Permit type: Gas | Permit status: Expired | Current use: 1-2fam | Permit id: G262993 | Parcel: 2006123000
2013/08/15500100107 Greaton Rd Roxbury Ma 02132Darren Chapman
SCORE
100
107 Greaton Rd Roxbury Ma 02132
Plumbing permit for minor water piping to backflow preventer for boielr and water piping for indirect fired water heater
Date:  August 15, 2013
Value:   $1,500
Contractor: Darren Chapman

Permit type: Plumbing | Permit status: Expired | Current use: 1-2fam | Permit id: Pl262994 | Parcel: 2006123000
2013/08/151500100107 Greaton Rd Roxbury Ma 02132Darren Chapman
SCORE
100
16 24 Union Park St Roxbury Ma 02118
Remove and dispose of existing weil mclain chimney vented / atmospheric gas boiler. Install a new lochinvar kbn211 (2 btu input) high effeceincy gas boiler. Line chimney with approved fas n seal ss chimney liner (3") also install a lochinvar sit0 / gallon ss indirect fired domestic hot water heater
Date:  August 15, 2013
Value:   $1,500
Contractor: Darren Chapman

Permit type: Gas | Permit status: Expired | Current use: 1-4fam | Permit id: G262657 | Parcel: 0305961000
2013/08/15150010016 24 Union Park St Roxbury Ma 02118Darren Chapman
SCORE
100
16 24 Union Park St Roxbury Ma 02118
Install new lochinvar sit0 - gallon ss indirect water heater (along with new boiler and new boiler watts 911 backflow device
Date:  August 15, 2013
Value:   $4,000
Contractor: Darren Chapman

Permit type: Plumbing | Permit status: Expired | Current use: 1-4fam | Permit id: Pl262679 | Parcel: 0305961000
2013/08/15400010016 24 Union Park St Roxbury Ma 02118Darren Chapman
SCORE
100
13 15 Worcester Sq Roxbury Ma 02118
Remove and dispose of two existing atmospheric gas boilers (burnham) supply and install two new lochivnar kbn286 boilers with two new sit0 indirect fired domestic hot water heaters... Include twin stainless steel chimney liners (one for each boiler) total gas input = 572 0 btus
Date:  August 16, 2013
Value:   $1,500
Contractor: Darren Chapman

Permit type: Gas | Permit status: Expired | Current use: 1-4fam | Permit id: G275508 | Parcel: 0801510010
2013/08/16150010013 15 Worcester Sq Roxbury Ma 02118Darren Chapman
SCORE
100
13 15 Worcester Sq Roxbury Ma 02118
As part of boiler replacemnt efforts... Replace two existing chimney vent 75 gallon water heaters and install twin lochinvar sit0 ss indirect fired water heaters and related water piping
Date:  August 16, 2013
Value:   $7,500
Contractor: Darren Chapman

Permit type: Plumbing | Permit status: Expired | Current use: 1-4fam | Permit id: Pl275579 | Parcel: 0801510010
2013/08/16750010013 15 Worcester Sq Roxbury Ma 02118Darren Chapman
SCORE
100
Monmouth St Boston Ma 02128
Install two indirect fired water heaters and two boielr backflow devices
Date:  October 10, 2013
Value:   $5,000
Contractor: Darren Chapman

Permit type: Plumbing | Permit status: Expired | Current use: 1-2fam | Permit id: Pl291752 | Parcel: 0102751000
2013/10/105000100Monmouth St Boston Ma 02128Darren Chapman
SCORE
100
Monmouth St Boston Ma 02128
Two new lohcinvar high effeciency - side wall vented gas boilers. First floor to recieve a lochinvar kbn106 (106 0 btu input) boiler. Second floor to recieve a lochinvar kbn151 (151 0 btu input) boiler.
Date:  October 10, 2013
Value:   $10,000
Contractor: Darren Chapman

Permit type: Gas | Permit status: Expired | Current use: 1-2fam | Permit id: G291737 | Parcel: 0102751000
2013/10/1010000100Monmouth St Boston Ma 02128Darren Chapman
SCORE
100
80 82 A St Boston Ma 02127
Address we have is 52 athens st #4 per richard chung (it person @ isd) use 80a st as athens ais on corner with a st.... Remove existing weather king furnace - install new 95% afue lennox gas furnace (45mbh input) - sidewall vented / direct vent appliance
Date:  January 22, 2014
Value:   $5,500
Contractor: Darren Chapman

Permit type: Gas | Permit status: Expired | Current use: Multi | Permit id: G319153 | Parcel: 0601197010
2014/01/22550010080 82 A St Boston Ma 02127Darren Chapman
SCORE
100
138 144 Lincoln St Boston Ma 02111
Install new furnace - lennox ml180uh110p48c - chimney vented 80% unit for the fifth floor living space. Also install lennox ml180uh110p48c furnace for the sixth floor living space.
Date:  February 6, 2014
Value:   $15,000
Contractor: Darren Chapman

Client: Rosenberg Lewis | Permit type: Gas | Permit status: Expired | Current use: 1-4fam | Permit id: G315878 | Parcel: 0304329000
2014/02/0615000100138 144 Lincoln St Boston Ma 02111Darren Chapman
SCORE
100
67 69 Brookley Rd Jamaica Plain Ma 02130
Remove and dispose of four chimney vented domestic hot water heaters. Supply and install four - lochinvar sit0 - gallon indirect fired ss water heaters. Also see gas permit fro four lochihnvar boilers - kbn081 - 81 0 btus each (plumbing permit for four watts 911 backflow devices one for each boiler)
Date:  March 18, 2014
Value:   $10,000
Contractor: Darren Chapman

Permit type: Plumbing | Permit status: Expired | Current use: 1-4fam | Permit id: Pl343610 | Parcel: 1102684000
2014/03/181000010067 69 Brookley Rd Jamaica Plain Ma 02130Darren Chapman
SCORE
100
67 69 Brookley Rd Jamaica Plain Ma 02130
Gas permit for four lochinvar kbn081 (81 0 btus input each. Replace four old cast iron chimney vented small boilers and install new sidewall vented high effeceincy boilers and four lochivnar sit0 ( gallon) indirect water heaters (see also plumbing permit app # pl3436 fro water heater and boiler backflow device permit)
Date:  March 18, 2014
Value:   $20,000
Contractor: Darren Chapman

Permit type: Gas | Permit status: Expired | Current use: 1-4fam | Permit id: G343618 | Parcel: 1102684000
2014/03/182000010067 69 Brookley Rd Jamaica Plain Ma 02130Darren Chapman
SCORE
100
Martin St Roxbury Ma 02132
Add small 1/2 bathroom to first floor
Date:  August 20, 2015
Value:   $1,500
Contractor: Darren Chapman

Permit type: Plumbing | Permit status: Open | Current use: 1-2fam | Permit id: Pl508389 | Parcel: 2002005000
2015/08/201500100Martin St Roxbury Ma 02132Darren Chapman
SCORE
100
228 2 Beacon St Boston Ma 02116
Please note that work is at 2 beacon st - computer did not allow #2 beacon / used 232 replace old cast iron boiler with new lochinvar ftxl high efficiency boiler. Boiler is to be vented to roof via ss (fas n seal) approved flue piping system. Gas infrastructure (for old boiler) already in place... (combustion air from side wall of building / pvc intake)
Date:  September 22, 2014
Value:   $15,000
Contractor: Darren Chapman

Client: Beacon Waterside Condo Trust | Permit type: Gas | Permit status: Expired | Current use: 1-4fam | Permit id: G408727 | Parcel: 0502624000
2014/09/2215000100228 2 Beacon St Boston Ma 02116Darren Chapman
SCORE
100
7 Tremont St Roxbury Ma 02118
Install new lennox gwm-100ie -1 0 btu sidewall vented boiler with an indirect fired ss water heater
Date:  December 18, 2014
Value:   $550
Contractor: Darren Chapman

Permit type: Gas | Permit status: Expired | Current use: 1-4fam | Permit id: G434109 | Parcel: 0900679000
2014/12/185501007 Tremont St Roxbury Ma 02118Darren Chapman
SCORE
100
7 Tremont St Roxbury Ma 02118
Install new lochinvar ss indirect water heater model; sit0 - gallon unit also install watts 911s combination fill and backflow device for new boiler feed
Date:  December 18, 2014
Contractor: Darren Chapman

Permit type: Plumbing | Permit status: Expired | Current use: 1-4fam | Permit id: Pl434111 | Parcel: 0900679000
2014/12/1801007 Tremont St Roxbury Ma 02118Darren Chapman
SCORE
100
16 24 Union Park St Boston Ma 02118
Remove and dispose of existing weil mclain chimney vented / atmospheric gas boiler. Install a new lochinvar kbn211 (2 btu input) high effeceincy gas boiler. Line chimney with approved fas n seal ss chimney liner (3") also install a lochinvar sit0 / gallon ss indirect fired domestic hot water heater
Date:  August 15, 2013
Value:   $1,500
Contractor: Darren Chapman

Permit type: Gas | Permit status: Expired | Current use: 1-4fam | Permit id: G262657 | Parcel: 0305961000
2013/08/15150010016 24 Union Park St Boston Ma 02118Darren Chapman
SCORE
100
16 24 Union Park St Boston Ma 02118
Install new lochinvar sit0 - gallon ss indirect water heater (along with new boiler and new boiler watts 911 backflow device
Date:  August 15, 2013
Value:   $4,000
Contractor: Darren Chapman

Permit type: Plumbing | Permit status: Expired | Current use: 1-4fam | Permit id: Pl262679 | Parcel: 0305961000
2013/08/15400010016 24 Union Park St Boston Ma 02118Darren Chapman
SCORE
100
13 15 Worcester Sq Boston Ma 02118
Remove and dispose of two existing atmospheric gas boilers (burnham) supply and install two new lochivnar kbn286 boilers with two new sit0 indirect fired domestic hot water heaters... Include twin stainless steel chimney liners (one for each boiler) total gas input = 572 0 btus
Date:  August 16, 2013
Value:   $1,500
Contractor: Darren Chapman

Permit type: Gas | Permit status: Expired | Current use: 1-4fam | Permit id: G275508 | Parcel: 0801510010
2013/08/16150010013 15 Worcester Sq Boston Ma 02118Darren Chapman
SCORE
100
13 15 Worcester Sq Boston Ma 02118
As part of boiler replacemnt efforts... Replace two existing chimney vent 75 gallon water heaters and install twin lochinvar sit0 ss indirect fired water heaters and related water piping
Date:  August 16, 2013
Value:   $7,500
Contractor: Darren Chapman

Permit type: Plumbing | Permit status: Expired | Current use: 1-4fam | Permit id: Pl275579 | Parcel: 0801510010
2013/08/16750010013 15 Worcester Sq Boston Ma 02118Darren Chapman
SCORE
100
80 82 A St South Boston Ma 02127
Address we have is 52 athens st #4 per richard chung (it person @ isd) use 80a st as athens ais on corner with a st.... Remove existing weather king furnace - install new 95% afue lennox gas furnace (45mbh input) - sidewall vented / direct vent appliance
Date:  January 22, 2014
Value:   $5,500
Contractor: Darren Chapman

Client: A St Condo | Permit type: Gas | Permit status: Expired | Current use: Multi | Permit id: G319153 | Parcel: 0601197010
2014/01/22550010080 82 A St South Boston Ma 02127Darren Chapman
SCORE
100
67 69 Brookley Rd Boston Ma 02130
Remove and dispose of four chimney vented domestic hot water heaters. Supply and install four - lochinvar sit0 - gallon indirect fired ss water heaters. Also see gas permit fro four lochihnvar boilers - kbn081 - 81 0 btus each (plumbing permit for four watts 911 backflow devices / one for each boiler)
Date:  March 18, 2014
Value:   $10,000
Contractor: Darren Chapman

Client: Blake Peter | Permit type: Plumbing | Permit status: Expired | Current use: 1-4fam | Permit id: Pl343610 | Parcel: 1102684000
2014/03/181000010067 69 Brookley Rd Boston Ma 02130Darren Chapman
SCORE
100
67 69 Brookley Rd Boston Ma 02130
Gas permit for four lochinvar kbn081 (81 0 btus input each. Replace four old cast iron chimney vented small boilers and install new sidewall vented high effeceincy boilers and four lochivnar sit0 ( gallon) indirect water heaters (see also plumbing permit app # pl3436 fro water heater and boiler backflow device permit)
Date:  March 18, 2014
Value:   $20,000
Contractor: Darren Chapman

Client: Blake Peter | Permit type: Gas | Permit status: Expired | Current use: 1-4fam | Permit id: G343618 | Parcel: 1102684000
2014/03/182000010067 69 Brookley Rd Boston Ma 02130Darren Chapman
SCORE
100
3032 Hutchings St Dorchester Ma 02121
Replacement of gas furnace
Date:  January 10, 2017
Value:   $500
Contractor: Darren Chapman

Client: Smith Daniel | Permit type: Gas | Permit status: Open | Current use: 1-2fam | Permit id: G671388 | Parcel: 1202309000
2017/01/105001003032 Hutchings St Dorchester Ma 02121Darren Chapman
SCORE
100
211 W Second St South Boston Ma 02127
Replacement of gas furnace
Date:  January 10, 2017
Value:   $500
Contractor: Darren Chapman

Client: Two 11 W Second St Condo Tr | Permit type: Gas | Permit status: Open | Current use: 1-3fam | Permit id: G671393 | Parcel: 0601502000
2017/01/10500100211 W Second St South Boston Ma 02127Darren Chapman
SCORE
100
58 Child St Hyde Park Ma 02136
Replace gas boiler with khn-155
Date:  January 26, 2017
Value:   $500
Contractor: Darren Chapman

Client: Oreilly Kathleen M | Permit type: Gas | Permit status: Open | Current use: 1-2fam | Permit id: G675991 | Parcel: 1811615000
2017/01/2650010058 Child St Hyde Park Ma 02136Darren Chapman
SCORE
100
58 Child St Hyde Park Ma 02136
Replace backflow on boiler and install indirect water heater
Date:  January 26, 2017
Value:   $1,000
Contractor: Darren Chapman

Client: Oreilly Kathleen M | Permit type: Plumbing | Permit status: Open | Current use: 1-2fam | Permit id: Pl675989 | Parcel: 1811615000
2017/01/26100010058 Child St Hyde Park Ma 02136Darren Chapman
SCORE
100
Date:  January 26, 2017
Value:   $500
Contractor: Darren Chapman

Permit type: Gas | Permit status: Open | Current use: Multi | Permit id: G675999
2017/01/2650010019 Commonwealth Av Brighton Ma 02135Darren Chapman
SCORE
100
6668 School St Boston Ma 02119
Replace furnace with a direct vented furnace
Date:  November 22, 2016
Value:   $500
Contractor: Darren Chapman

Client: Fripp James N | Permit type: Gas | Permit status: Open | Current use: 1-2fam | Permit id: G659338 | Parcel: 1101472000
2016/11/225001006668 School St Boston Ma 02119Darren Chapman
SCORE
100
189199 Forest Hills Boston Ma 02130
Replace 3-boilers 3- backflow preventers bldg. Four 195 197 and 199
Date:  September 6, 2016
Value:   $500
Contractor: Darren Chapman

Client: Forest Hills Housing Inc | Permit type: Plumbing | Permit status: Open | Current use: Multi | Permit id: Pl633664 | Parcel: 1102926000
2016/09/06500100189199 Forest Hills Boston Ma 02130Darren Chapman
SCORE
100
Date:  May 11, 2017
Value:   $500
Contractor: Darren Chapman

Client: One 14 Commonwealth Condo Tr | Permit type: Gas | Permit status: Open | Current use: Multi | Permit id: G707755 | Parcel: 0501357000
2017/05/11500100114 Commonwealth Av Boston Ma 02116Darren Chapman
SCORE
100
114 Commonwealth Av Boston Ma 02116
Replace cross connection for boiler and install indirect water heater
Date:  May 11, 2017
Value:   $1,500
Contractor: Darren Chapman

Client: One 14 Commonwealth Condo Tr | Permit type: Plumbing | Permit status: Open | Current use: Multi | Permit id: Pl707757 | Parcel: 0501357000
2017/05/111500100114 Commonwealth Av Boston Ma 02116Darren Chapman
SCORE
100
844 Metropolitan Av Hyde Park Ma 02136
Cross connections device for boiler also install indirect water heater
Date:  May 11, 2017
Value:   $1,000
Contractor: Darren Chapman

Client: Lee Perry T | Permit type: Plumbing | Permit status: Open | Current use: 1-2fam | Permit id: Pl707753 | Parcel: 1811085000
2017/05/111000100844 Metropolitan Av Hyde Park Ma 02136Darren Chapman
SCORE
100
Date:  May 11, 2017
Value:   $500
Contractor: Darren Chapman

Client: Lee Perry T | Permit type: Gas | Permit status: Open | Current use: 1-2fam | Permit id: G707752 | Parcel: 1811085000
2017/05/11500100844 Metropolitan Av Hyde Park Ma 02136Darren Chapman
SCORE
100
362 Arborway Boston Ma 02130
Remove existing water heater and replace with indirect fired hot water heater. Lochinvar sit080
Date:  June 13, 2017
Value:   $1,500
Contractor: Darren Chapman

Client: Fingerman David A | Permit type: Plumbing | Permit status: Open | Current use: 1-2fam | Permit id: Pl719673 | Parcel: 1103379000
2017/06/131500100362 Arborway Boston Ma 02130Darren Chapman
SCORE
100
83 Elm St Boston Ma 02130
Replace old furnace with new gas furnace
Date:  June 15, 2017
Value:   $500
Contractor: Darren Chapman

Client: Brooker Robert E Iii | Permit type: Gas | Permit status: Open | Current use: 1-2fam | Permit id: G720725 | Parcel: 1901302010
2017/06/1550010083 Elm St Boston Ma 02130Darren Chapman
SCORE
100
Date:  March 9, 2017
Value:   $500
Contractor: Darren Chapman

Client: Minturn Robert B Jr | Permit type: Gas | Permit status: Open | Current use: 1-3fam | Permit id: G686458 | Parcel: 0400524000
2017/03/09500100186 W Brookline St Boston Ma 02118Darren Chapman
SCORE
100
939961 Tremont St Mission Hill Ma 02120
Replace cross connection device
Date:  June 29, 2017
Value:   $500
Contractor: Darren Chapman

Client: Madison Davenport Inc | Permit type: Plumbing | Permit status: Open | Current use: Multi | Permit id: Pl726010 | Parcel: 0901335050
2017/06/29500100939961 Tremont St Mission Hill Ma 02120Darren Chapman
SCORE
100
228 W Canton St Boston Ma 02116
Replacing gas boiler
Date:  June 29, 2017
Value:   $500
Contractor: Darren Chapman

Client: Two 28 W Canton St Condo Tr | Permit type: Gas | Permit status: Open | Current use: 1-3fam | Permit id: G725990 | Parcel: 0400694000
2017/06/29500100228 W Canton St Boston Ma 02116Darren Chapman
SCORE
100
228 W Canton St Boston Ma 02116
Cross connection device
Date:  July 13, 2017
Value:   $500
Contractor: Darren Chapman

Client: Two 28 W Canton St Condo Tr | Permit type: Plumbing | Permit status: Open | Current use: 1-3fam | Permit id: Pl725992 | Parcel: 0400694000
2017/07/13500100228 W Canton St Boston Ma 02116Darren Chapman
SCORE
100
Date:  July 13, 2017
Value:   $500
Contractor: Darren Chapman

Client: Madison Davenport Inc | Permit type: Gas | Permit status: Open | Current use: Multi | Permit id: G726007 | Parcel: 0901335050
2017/07/13500100939961 Tremont St Mission Hill Ma 02120Darren Chapman
SCORE
100
44 White St East Boston Ma 02128
Replace gas roof top unit
Date:  July 14, 2017
Value:   $500
Contractor: Darren Chapman

Client: Gray Allyson | Permit type: Gas | Permit status: Open | Current use: 1-3fam | Permit id: G730345 | Parcel: 0103418000
2017/07/1450010044 White St East Boston Ma 02128Darren Chapman
SCORE
100
Cedar Lane Wy Boston Ma 02108
Replace gas furnace
Date:  July 19, 2017
Value:   $500
Contractor: Darren Chapman

Client: Gaud Susan M Trsts | Permit type: Gas | Permit status: Open | Current use: 1-3fam | Permit id: G729303 | Parcel: 0501774000
2017/07/19500100Cedar Lane Wy Boston Ma 02108Darren Chapman
SCORE
100
9 Upton St Boston Ma 02118
Replace gas furnace
Date:  July 19, 2017
Value:   $500
Contractor: Darren Chapman

Client: Nine Upton St Condo Trust | Permit type: Gas | Permit status: Open | Current use: 1-3fam | Permit id: G729286 | Parcel: 0306954000
2017/07/195001009 Upton St Boston Ma 02118Darren Chapman
SCORE
100
247 Commonwealth Av Boston Ma 02116
Replacement of furnace in basement
Date:  September 21, 2016
Value:   $500
Contractor: Darren Chapman

Client: Two 47 Commonwealth Avenue | Permit type: Gas | Permit status: Open | Current use: 1-4fam | Permit id: G636319 | Parcel: 0503393000
2016/09/21500100247 Commonwealth Av Boston Ma 02116Darren Chapman
SCORE
100
Date:  September 21, 2016
Value:   $500
Contractor: Darren Chapman

Client: Ten-Twelve Colgate Road | Permit type: Plumbing | Permit status: Open | Current use: 1-3fam | Permit id: Pl637071 | Parcel: 1902913000
2016/09/215001001012 Colgate Rd Roslindale Ma 02131Darren Chapman
SCORE
100
1012 Colgate Rd Roslindale Ma 02131
Replace failed gas (steam) boiler...
Date:  September 27, 2016
Value:   $500
Contractor: Darren Chapman

Client: Ten-Twelve Colgate Road | Permit type: Gas | Permit status: Open | Current use: 1-3fam | Permit id: G634267 | Parcel: 1902913000
2016/09/275001001012 Colgate Rd Roslindale Ma 02131Darren Chapman
SCORE
100
75 Revere St Boston Ma 02114
Install new lochinvar sit51 stainless steel indirect fired domestic hot water heater
Date:  September 21, 2010
Value:   $2,500
Contractor: Darren Chapman

Client: Moran William K | Permit type: Plumbing | Current use: 1-2fam | Permit id: Pl43410 | Parcel: 502025000
2010/09/21250010075 Revere St Boston Ma 02114Darren Chapman
SCORE
100
Washington St Brighton Ma 02135
Replacement of roof top unit
Date:  October 18, 2016
Value:   $24,820
Contractor: Darren Chapman

Client: Bnai Brith Sr Citizens | Permit type: Gas | Permit status: Open | Current use: Multi | Permit id: G646554 | Parcel: 2101991000
2016/10/1824820100Washington St Brighton Ma 02135Darren Chapman
SCORE
100
34 Arborway Boston Ma 02130
Replace gas boiler with 95% lochinvar boiler and indirect gallon water heater
Date:  October 26, 2016
Value:   $21,800
Contractor: Darren Chapman

Client: Butts Jeff | Permit type: Gas | Permit status: Open | Current use: 1-2fam | Permit id: G650351 | Parcel: 1901591000
2016/10/262180010034 Arborway Boston Ma 02130Darren Chapman
SCORE
100
34 Arborway Boston Ma 02130
Back-flow for boiler and indirect water heater
Date:  October 26, 2016
Value:   $12,800
Contractor: Darren Chapman

Client: Butts Jeff | Permit type: Plumbing | Permit status: Open | Current use: 1-2fam | Permit id: Pl650352 | Parcel: 1901591000
2016/10/261280010034 Arborway Boston Ma 02130Darren Chapman
SCORE
100
Date:  November 1, 2016
Value:   $500
Contractor: Darren Chapman

Permit type: Gas | Permit status: Open | Current use: 1-2fam | Permit id: G652788
2016/11/015001003535c Middle St South Boston Ma 02125Darren Chapman
SCORE
100
234236 S Huntington Boston Ma 02130
Install a new 296 0 frunace & 000btu ruud water heater
Date:  May 9, 2016
Value:   $1,500
Contractor: Darren Chapman

Client: Two-34-236 S Huntington Av | Permit type: Gas | Permit status: Expired | Current use: Multi | Permit id: G588797 | Parcel: 1001784000
2016/05/091500100234236 S Huntington Boston Ma 02130Darren Chapman
SCORE
100
234236 S Huntington Boston Ma 02130
Install new gallon ruud chimney vented glass lined water heater
Date:  May 9, 2016
Value:   $1,500
Contractor: Darren Chapman

Client: Two-34-236 S Huntington Av | Permit type: Plumbing | Permit status: Expired | Current use: Multi | Permit id: Pl588796 | Parcel: 1001784000
2016/05/091500100234236 S Huntington Boston Ma 02130Darren Chapman
SCORE
100
4 Walk Hill St Dorchester Ma 02126
Remove and dispose of failed trianco "heatmaker" boiler and indirect glass lined hot water heater. Install a new lochinvar whn1 (1 btu input) high effeciency - side wall vented boiler and matching stianless steel indirect water heater model number sit0 - gallon indirect
Date:  November 12, 2012
Value:   $1,500
Contractor: Darren Chapman

Permit type: Gas | Permit status: Expired | Current use: 1-2fam | Permit id: G181198
2012/11/1215001004 Walk Hill St Dorchester Ma 02126Darren Chapman
SCORE
100
19 Louisburg Sq Boston Ma 02108
Replace 20 year old gas boielr with twin new burnham p205 130 000 btu input boilers
Date:  September 17, 2014
Value:   $1,000
Contractor: Darren Chapman

Client: Smith Linda K | Permit type: Gas | Permit status: Expired | Current use: 1-2fam | Permit id: G404282 | Parcel: 0501651110
2014/09/17100010019 Louisburg Sq Boston Ma 02108Darren Chapman
SCORE
100
75 Revere St Boston Ma 02114
Install a new buderus gb142 45 - 94% effecient boiler. 167 000 rated input
Date:  September 21, 2010
Value:   $7,500
Contractor: Darren Chapman

Client: Moran William K | Permit type: Gas | Permit status: Expired | Current use: 1-2fam | Permit id: G43400 | Parcel: 0502025000
2010/09/21750010075 Revere St Boston Ma 02114Darren Chapman
SCORE
100
19 Commonwealth Av Brighton Ma 02135
Repalce failed furnace with new lennoxml180uh070e36b chimney vented (80% category i) furnace
Date:  March 27, 2013
Value:   $4,500
Contractor: Darren Chapman

Permit type: Gas | Permit status: Expired | Current use: Multi | Permit id: G230333
2013/03/27450010019 Commonwealth Av Brighton Ma 02135Darren Chapman
SCORE
100
107 Greaton Rd Boston Ma 02132
Plumbing permit for minor water piping to backflow preventer for boielr and water piping for indirect fired water heater
Date:  August 15, 2013
Value:   $1,500
Contractor: Darren Chapman

Client: Herring Nancy | Permit type: Plumbing | Permit status: Expired | Current use: 1-2fam | Permit id: Pl262994 | Parcel: 2006123000
2013/08/151500100107 Greaton Rd Boston Ma 02132Darren Chapman
SCORE
100
19 Louisburg Sq Boston Ma 02108
Replacing heating boiler - new backflow device shall be installed (twin new burnham p205 boilers) - see also gas permit # g404282
Date:  September 17, 2014
Value:   $1,000
Contractor: Darren Chapman

Client: Smith Linda K | Permit type: Plumbing | Current use: 1-2fam | Permit id: Pl404284 | Parcel: 501651110
2014/09/17100010019 Louisburg Sq Boston Ma 02108Darren Chapman
SCORE
100
4 Walk Hill St Dorchester Ma 02126
Install water heater and modified piping for new lochinvar sit0 gallon indirect hot watewr heater. Install watts 911s backflow boielr feed device for new lochinvar whn1 gas boiler
Date:  November 12, 2012
Value:   $1,500
Contractor: Darren Chapman

Permit type: Plumbing | Permit status: Expired | Current use: 1-2fam | Permit id: Pl181199
2012/11/1215001004 Walk Hill St Dorchester Ma 02126Darren Chapman
SCORE
100
632 W Roxbury Pk Boston Ma 02132
Replace exisitng boiler with new lochinvar kbn151 (151 000mbh input) side wall vented - condesning / modulating hydronic boiler
Date:  October 7, 2010
Value:   $9,000
Contractor: Darren Chapman

Permit type: Gas | Permit status: Expired | Current use: 1-2fam | Permit id: G45131
2010/10/079000100632 W Roxbury Pk Boston Ma 02132Darren Chapman
SCORE
100
107 Greaton Rd Boston Ma 02132
Remove and dispose of old cast iron gas converted chimney vented boiler. Supply and install a new lochinvar kbn151 (1 0 btu input) gas / high effeciency side wall vented boiler - with a new lochinvar sit0 - gallon ss indirect fired domestic hot water heater
Date:  August 15, 2013
Value:   $500
Contractor: Darren Chapman

Client: Herring Nancy | Permit type: Gas | Permit status: Expired | Current use: 1-2fam | Permit id: G262993 | Parcel: 2006123000
2013/08/15500100107 Greaton Rd Boston Ma 02132Darren Chapman
SCORE
100
186 W Brookline St Boston Ma 02118
Replace old rooftop unit with new 000mbh unput lennox 15gcsxav-36-0 rooftop heat cool unit
Date:  September 15, 2011
Value:   $3,500
Contractor: Darren Chapman

Client: Minturn Robert B Jr | Permit type: Gas | Permit status: Expired | Current use: 1-2fam | Permit id: G92552 | Parcel: 0400524000
2011/09/153500100186 W Brookline St Boston Ma 02118Darren Chapman
SCORE
100
1315 Worcester Sq Boston Ma 02118
As part of boiler replacemnt efforts... Replace two existing chimney vent 75 gallon water heaters and install twin lochinvar sit0 ss indirect fired water heaters and related water piping
Date:  August 16, 2013
Value:   $7,500
Contractor: Darren Chapman

Client: Thirteen-15 Worcester Sq | Permit type: Plumbing | Permit status: Expired | Current use: 1-4fam | Permit id: Pl275579 | Parcel: 0801510010
2013/08/1675001001315 Worcester Sq Boston Ma 02118Darren Chapman
SCORE
100
4 Monument Sq Charlestown Ma 02129
Remove and dispose of old oil fired boiler. Install new gas service for new gas fired boiler - lochinvar kbn211 (211 000 btu input)... Gas pipipng will be less than ten feet developed length from exterior meter to interior boiler location...
Date:  August 16, 2013
Value:   $1,500
Contractor: Darren Chapman

Client: Carlton House Condominium Tr | Permit type: Gas | Permit status: Expired | Current use: 1-4fam | Permit id: G275390 | Parcel: 0203387000
2013/08/1615001004 Monument Sq Charlestown Ma 02129Darren Chapman
SCORE
100
Monmouth St East Boston Ma 02128
Install two indirect fired water heaters and two boielr backflow devices
Date:  October 10, 2013
Value:   $5,000
Contractor: Darren Chapman

Client: Bonney Jonathan R | Permit type: Plumbing | Permit status: Expired | Current use: 1-2fam | Permit id: Pl291752 | Parcel: 0102751000
2013/10/105000100Monmouth St East Boston Ma 02128Darren Chapman
SCORE
100
8 Oriole St Boston Ma 02132
Replace 1 fixture.
Date:  February 11, 2010
Contractor: Darren Chapman

Client: Crowley Sean T | Permit type: Plumbing | Permit status: Expired | Current use: 1-7fam | Permit id: Pl14018 | Parcel: 2002148000
2010/02/1101008 Oriole St Boston Ma 02132Darren Chapman
SCORE
100
4 Boylston Pl Boston Ma 02116
Remove two oil fired boilers and oil storage tanks install one lochinvar kbn400 (399 000 btu input) hydronic boiler - side wall vanted to private courtyard area install one burnham k5006snei (401 000 btu input) steam boiler chimney vented
Date:  July 17, 2012
Value:   $1,500
Contractor: Darren Chapman

Client: The Tavern Club | Permit type: Gas | Permit status: Expired | Current use: 7more | Permit id: G156619 | Parcel: 0500038000
2012/07/1715001004 Boylston Pl Boston Ma 02116Darren Chapman
SCORE
100
28 Marlborough St Boston Ma 02116
Replace existing boiler with new buderus g234x55 atmospheric gas boiler 228 000 input cast iron boiler
Date:  November 2, 2010
Value:   $8,000
Contractor: Darren Chapman

Client: 28 Marlborough St Condo Trust | Permit type: Gas | Permit status: Expired | Current use: 1-4fam | Permit id: G49792 | Parcel: 0502842000
2010/11/02800010028 Marlborough St Boston Ma 02116Darren Chapman
SCORE
100
1624 Union Park St Boston Ma 02118
Install new lochinvar sit0 - gallon ss indirect water heater (along with new boiler and new boiler watts 911 backflow device
Date:  August 15, 2013
Value:   $4,000
Contractor: Darren Chapman

Permit type: Plumbing | Permit status: Expired | Current use: 1-4fam | Permit id: Pl262679 | Parcel: 0305961000
2013/08/1540001001624 Union Park St Boston Ma 02118Darren Chapman
SCORE
100
105 Radcliffe St Dorchester Ma 02121
Replace oil fired furnace with new lennox el296uh110xv48c gas - direct / sidewall vented furnace
Date:  December 6, 2012
Value:   $5,000
Contractor: Darren Chapman

Client: Courtney Alfonzia | Permit type: Gas | Permit status: Expired | Current use: 1-3fam | Permit id: G196766 | Parcel: 1402361000
2012/12/065000100105 Radcliffe St Dorchester Ma 02121Darren Chapman
SCORE
100
484 Beacon St Boston Ma 02115
Replace failed heater unit with new htp "versa-hydro" dhw / space heating combination system
Date:  December 15, 2011
Value:   $500
Contractor: Darren Chapman

Client: Chapin Stewart | Permit type: Gas | Permit status: Expired | Current use: 1-4fam | Permit id: G109539 | Parcel: 0503688004
2011/12/15500100484 Beacon St Boston Ma 02115Darren Chapman
SCORE
100
34 Warren Av Boston Ma 02116
Replace a failed rooftop gas / electric rooftop heat / cool unit. Install carrier 48hced08aa2a5-0a0a0.... 7. 5ton
Date:  September 6, 2011
Value:   $12,000
Contractor: Darren Chapman

Permit type: Gas | Permit status: Expired | Current use: Comm | Permit id: G91736
2011/09/061200010034 Warren Av Boston Ma 02116Darren Chapman
SCORE
100
24 Westglow St Dorchester Ma 02122
Replace failed (chimney vented) water heater ruud gallon gas
Date:  April 1, 2010
Value:   $800
Contractor: Darren Chapman

Client: Henricks Elise M | Permit type: Plumbing | Permit status: Expired | Current use: 1-2fam | Permit id: Pl19533 | Parcel: 1602047000
2010/04/0180010024 Westglow St Dorchester Ma 02122Darren Chapman
SCORE
100
Garden St Boston Ma 02114
1)run new gas service from existing meter location at front of property down a long outdoor "corridor" to a new boiler room space at rear of building. Total developed length approx. 1 feet - using 1-1/4" sched steel 2)connect new gas line to a new lochivnar kbn211 condensing modulating high effeciency boiler 3)boiler is to be vented with polymer liner (manufacturer approved) inno-flue... Liner to be installed by billy sweet chimney sweeps
Date:  January 22, 2013
Value:   $3,500
Contractor: Darren Chapman

Client: Pci Management Llc | Permit type: Gas | Permit status: Expired | Current use: 1-4fam | Permit id: G200135 | Parcel: 0502152000
2013/01/223500100Garden St Boston Ma 02114Darren Chapman
SCORE
100
2282 Beacon St Boston Ma 02116
Please note that work is at 2 beacon st - computer did not allow #2 beacon used 232 replace old cast iron boiler with new lochinvar ftxl high efficiency boiler. Boiler is to be vented to roof via ss (fas n seal) approved flue piping system. Gas infrastructure (for old boiler) already in place... (combustion air from side wall of building pvc intake)
Date:  September 22, 2014
Value:   $15,000
Contractor: Darren Chapman

Client: Viola Frank L Trst | Permit type: Gas | Permit status: Expired | Current use: 1-4fam | Permit id: G408727 | Parcel: 0502624000
2014/09/22150001002282 Beacon St Boston Ma 02116Darren Chapman
SCORE
100
663a E Fifth St South Boston Ma 02127
Correct pvc flue piping that is not per code or manufacturers specifications
Date:  October 31, 2012
Value:   $3,600
Contractor: Darren Chapman

Permit type: Gas | Current use: 1-3fam | Permit id: G189931
2012/10/313600100663a E Fifth St South Boston Ma 02127Darren Chapman
SCORE
100
8 Rutland Sq Boston Ma 02118
Gas fitting nipples valve etc for new furnace installation (replacement) installing lennox ml180-090p48b... 90mbh input furnace
Date:  April 14, 2011
Value:   $250
Contractor: Darren Chapman

Client: Eight Rutland Sq #2 Llc | Permit type: Gas | Permit status: Expired | Current use: 1-4fam | Permit id: G72025 | Parcel: 0402717010
2011/04/142501008 Rutland Sq Boston Ma 02118Darren Chapman
SCORE
100
86 Moss Hill Rd Boston Ma 02130
Remove and dispose of failed cast iron / chimney vented boiler. Supply and install a new lochivnar kbn151 (151 0 btu input) high effeciency side wall vented boiler. See alos plumbing permit for backflow device and lochivnar sit0 - gallon ss indirect fired domestic hot water heater
Date:  October 24, 2013
Value:   $1,500
Contractor: Darren Chapman

Client: Greene Mary Louise | Permit type: Gas | Permit status: Expired | Current use: 1-2fam | Permit id: G295319 | Parcel: 1902475000
2013/10/24150010086 Moss Hill Rd Boston Ma 02130Darren Chapman
SCORE
100
9 Concord Sq Boston Ma 02118
Replace failed burnham boiler with new lochinvar kbn211 boiler and also install new lochinvar sit0 indirect fired domestic hot water heater
Date:  August 15, 2013
Value:   $1,500
Contractor: Darren Chapman

Client: Nine Concord Sq Condo Tr | Permit type: Gas | Permit status: Expired | Current use: 1-4fam | Permit id: G274907 | Parcel: 0402665000
2013/08/1515001009 Concord Sq Boston Ma 02118Darren Chapman
SCORE
100
8082 A St South Boston Ma 02127
Address we have is 52 athens st #4 per richard chung (it person @ isd) use 80a st as athens ais on corner with a st.... Remove existing weather king furnace - install new 95% afue lennox gas furnace (45mbh input) - sidewall vented direct vent appliance
Date:  January 22, 2014
Value:   $5,500
Contractor: Darren Chapman

Client: Eighty A Street Condo Tr | Permit type: Gas | Permit status: Expired | Current use: Multi | Permit id: G319153 | Parcel: 0601197010
2014/01/2255001008082 A St South Boston Ma 02127Darren Chapman
SCORE
100
1624 Union Park St Boston Ma 02118
Remove and dispose of existing weil mclain chimney vented atmospheric gas boiler. Install a new lochinvar kbn211 (2 btu input) high effeceincy gas boiler. Line chimney with approved fas n seal ss chimney liner (3") also install a lochinvar sit0 gallon ss indirect fired domestic hot water heater
Date:  August 15, 2013
Value:   $1,500
Contractor: Darren Chapman

Permit type: Gas | Permit status: Expired | Current use: 1-4fam | Permit id: G262657 | Parcel: 0305961000
2013/08/1515001001624 Union Park St Boston Ma 02118Darren Chapman
SCORE
100
25 Wales St Dorchester Ma 02124
Replace existing utica steam boiler with new utica peg187c steam boiler (187 000btu input)
Date:  August 3, 2011
Value:   $4,500
Contractor: Darren Chapman

Client: Austin Richard C Ts | Permit type: Gas | Permit status: Expired | Current use: 1-2fam | Permit id: G77580 | Parcel: 1401943000
2011/08/03450010025 Wales St Dorchester Ma 02124Darren Chapman
SCORE
100
Date:  April 1, 2010
Value:   $5,000
Contractor: Darren Chapman

Permit type: Gas | Current use: Mixed | Permit id: G19530
2010/04/015000100450c Walk Hill St Mattapan Ma 02126Darren Chapman
SCORE
100
34 Myrtle St Boston Ma 02114
Install hydronic heating and refrigeration cooling lines with an air handler to facilitate adding and autonomous dedicated heating cooiling system for penthouse unit # 5 @ 34 myrtle st. Boston
Date:  May 19, 2010
Value:   $15,000
Contractor: Darren Chapman

Client: West End Trust | Permit type: Other | Current use: 5unit | Permit id: Sf26537 | Parcel: 501880000
2010/05/191500010034 Myrtle St Boston Ma 02114Darren Chapman
SCORE
100
25 Holbrook St Boston Ma 02130
Remove old oil fired furnace and install new 97% high effeciency lennox furnace. Install lennox slp98uh090v48c - 0 btu
Date:  September 6, 2011
Value:   $8,000
Contractor: Darren Chapman

Client: Frank Eric Ts | Permit type: Gas | Permit status: Expired | Current use: 1-2fam | Permit id: G91739 | Parcel: 1901792000
2011/09/06800010025 Holbrook St Boston Ma 02130Darren Chapman
SCORE
100
6 E Sixth St South Boston Ma 02127
Replace existing boiler with new lochinvar kbn106 high effeciency gas boiler. Include a lochinvar sit0 indirect fired domestic hot water heater adn safety mix valve. Minor water piping to accomodate this new water heater and boiler backflow preventer (watts 911)
Date:  August 30, 2012
Value:   $1,500
Contractor: Darren Chapman

Client: Landry Nicholas J | Permit type: Plumbing | Permit status: Expired | Current use: 1-2fam | Permit id: Pl174589 | Parcel: 0602436000
2012/08/3015001006 E Sixth St South Boston Ma 02127Darren Chapman
SCORE
100
42 Irving St Boston Ma 02114
Boiler replacement - new watts 911 backflow
Date:  May 14, 2015
Contractor: Darren Chapman

Client: Walton Nathaniel Y | Permit type: Plumbing | Permit status: Expired | Current use: 1-2fam | Permit id: Pl470465 | Parcel: 0300217000
2015/05/14010042 Irving St Boston Ma 02114Darren Chapman
SCORE
100
15 Zamora St Boston Ma 02130
Replace old chimney vented furnace with new pvc / direct vented lennox furnace - model el195uh135xe60d ... 135mbh input
Date:  October 18, 2011
Value:   $4,000
Contractor: Darren Chapman

Client: Washington David R Ts | Permit type: Gas | Permit status: Expired | Current use: 1-2fam | Permit id: G98649 | Parcel: 1002192000
2011/10/18400010015 Zamora St Boston Ma 02130Darren Chapman
SCORE
100
18881892 Washington Boston Ma 02118
Replace existing rooftop unit with new lennox kga092s4bm 7. 5 ton gas electric unit
Date:  June 16, 2016
Value:   $750
Contractor: Darren Chapman

Client: Bean Marilyn B | Permit type: Gas | Permit status: Expired | Current use: Comm | Permit id: G602002 | Parcel: 0801838000
2016/06/1675010018881892 Washington Boston Ma 02118Darren Chapman
SCORE
100
86 Moss Hill Rd Boston Ma 02130
Permit for new boiler backflow device (watts 911) and for new indirect fired domestic hot water heater
Date:  October 24, 2013
Value:   $1,500
Contractor: Darren Chapman

Client: Greene Mary Louise | Permit type: Plumbing | Permit status: Expired | Current use: 1-2fam | Permit id: Pl295325 | Parcel: 1902475000
2013/10/24150010086 Moss Hill Rd Boston Ma 02130Darren Chapman
SCORE
100
34 Myrtle St Boston Ma 02114
Gas piping needs to support a new / dedicated boiler for an autonomous hydro-air heating system dedicated for the "penthouse" unit # 5 @ 34 myrtle st.
Date:  May 19, 2010
Value:   $2,500
Contractor: Darren Chapman

Client: West End Trust | Permit type: Gas | Permit status: Expired | Current use: 1unit | Permit id: G25554 | Parcel: 0501880000
2010/05/19250010034 Myrtle St Boston Ma 02114Darren Chapman
SCORE
100
5 Prescott St Charlestown Ma 02129
Replace existing 80% gas furnace with new high effeceincy carrier furnace. Install carrier 58uvb080-1-14 - 80mbh input furnace
Date:  April 4, 2011
Value:   $9,000
Contractor: Darren Chapman

Client: 5 Prescott St Condo | Permit type: Gas | Current use: 1-2fam | Permit id: G69224 | Parcel: 203776000
2011/04/0490001005 Prescott St Charlestown Ma 02129Darren Chapman
SCORE
100
56 Pinckney St Boston Ma 02114
Replace chimney vented water heater.
Date:  February 4, 2010
Contractor: Darren Chapman

Client: Bordewick James R Jr | Permit type: Plumbing | Current use: 1-7fam | Permit id: Pl13595 | Parcel: 501664000
2010/02/04010056 Pinckney St Boston Ma 02114Darren Chapman
SCORE
100
31 Parkton Rd Boston Ma 02130
Delete existing steam boiler and steam piping infrastructure. Supply and install a new lennox el195uh070xe36b ( 0 btu input) gas furnace - side wall vented...
Date:  February 26, 2014
Value:   $6,500
Contractor: Darren Chapman

Client: Parkton Road Llc | Permit type: Gas | Permit status: Expired | Current use: 1-3fam | Permit id: G322097 | Parcel: 1002126000
2014/02/26650010031 Parkton Rd Boston Ma 02130Darren Chapman
SCORE
100
189199 Forest Hills Boston Ma 02130
Replace three boilers 3-backflow preventers bldg. Three #189 191 and 193
Date:  September 6, 2016
Value:   $500
Contractor: Darren Chapman

Client: Forest Hills Housing Inc | Permit type: Plumbing | Permit status: Open | Current use: Multi | Permit id: Pl633659 | Parcel: 1102926000
2016/09/06500100189199 Forest Hills Boston Ma 02130Darren Chapman
SCORE
100
4 Monument Sq Charlestown Ma 02129
Remove and dispose of existing indirect (oil) fired water heater. Supply and install a new superstor ssu119 indirect fired water heater along with a new lochinvar kbn211 hot water boiler (backflow device)
Date:  August 16, 2013
Value:   $5,000
Contractor: Darren Chapman

Client: Carlton House Condominium Tr | Permit type: Plumbing | Current use: 1-4fam | Permit id: Pl275398 | Parcel: 203387000
2013/08/1650001004 Monument Sq Charlestown Ma 02129Darren Chapman
SCORE
100
6769 Brookley Rd Boston Ma 02130
Remove and dispose of four chimney vented domestic hot water heaters. Supply and install four - lochinvar sit0 - gallon indirect fired ss water heaters. Also see gas permit fro four lochihnvar boilers - kbn081 - 81 0 btus each (plumbing permit for four watts 911 backflow devices one for each boiler)
Date:  March 18, 2014
Value:   $10,000
Contractor: Darren Chapman

Client: Kilgore James R | Permit type: Plumbing | Permit status: Expired | Current use: 1-4fam | Permit id: Pl343610 | Parcel: 1102684000
2014/03/18100001006769 Brookley Rd Boston Ma 02130Darren Chapman
SCORE
100
Bourne St Boston Ma 02130
Install boiler (watts) 911 valve & install an indirect fired (lochinvar sss051) water heater
Date:  April 1, 2010
Value:   $3,000
Contractor: Darren Chapman

Client: Knopf-Goldner Mark A | Permit type: Plumbing | Permit status: Expired | Current use: 1unit | Permit id: Pl19769 | Parcel: 1904531000
2010/04/013000100Bourne St Boston Ma 02130Darren Chapman
SCORE
100
484 Beacon St Boston Ma 02115
Repalce existing heating unit with new htp - versa-hydro system. System is heating boiler and dhw production device 199 00 input se gas permit # g109539
Date:  December 15, 2011
Value:   $1,500
Contractor: Darren Chapman

Client: Chapin Stewart | Permit type: Plumbing | Permit status: Expired | Current use: 1-4fam | Permit id: Pl109544 | Parcel: 0503688004
2011/12/151500100484 Beacon St Boston Ma 02115Darren Chapman
SCORE
100
1 Salem St Boston Ma 02113
Plumbing pemrit for twin new lochinvar boilers - backflow preventer and 119 gallon ss indirect water heater
Date:  January 14, 2014
Value:   $5,500
Contractor: Darren Chapman

Client: Yip Collin Chun Yin Ts | Permit type: Plumbing | Permit status: Expired | Current use: Mixed | Permit id: Pl318447 | Parcel: 0301335000
2014/01/1455001001 Salem St Boston Ma 02113Darren Chapman
SCORE
100
7 Tremont St Boston Ma 02118
Install new lochinvar ss indirect water heater model; sit0 - gallon unit also install watts 911s combination fill and backflow device for new boiler feed
Date:  December 18, 2014
Contractor: Darren Chapman

Client: Seven Tremont St Condo | Permit type: Plumbing | Permit status: Expired | Current use: 1-4fam | Permit id: Pl434111 | Parcel: 0900679000
2014/12/1801007 Tremont St Boston Ma 02118Darren Chapman
SCORE
100
1315 Worcester Sq Boston Ma 02118
Remove and dispose of two existing atmospheric gas boilers (burnham) supply and install two new lochivnar kbn286 boilers with two new sit0 indirect fired domestic hot water heaters... Include twin stainless steel chimney liners (one for each boiler) total gas input = 572 0 btus
Date:  August 16, 2013
Value:   $1,500
Contractor: Darren Chapman

Client: Thirteen-15 Worcester Sq | Permit type: Gas | Permit status: Expired | Current use: 1-4fam | Permit id: G275508 | Parcel: 0801510010
2013/08/1615001001315 Worcester Sq Boston Ma 02118Darren Chapman
SCORE
100
995 Centre St Boston Ma 02130
Install new lochinvar kbn151 high effeciency gas boiler (watts 911 backflow device) and water piping to and from new lochinvar sit0 - gallon ss indirect fired domestic hot water heater
Date:  October 10, 2013
Value:   $5,000
Contractor: Darren Chapman

Client: Doty Constance | Permit type: Plumbing | Permit status: Expired | Current use: 1-2fam | Permit id: Pl291704 | Parcel: 1902502010
2013/10/105000100995 Centre St Boston Ma 02130Darren Chapman
SCORE
100
57 Burroughs St Boston Ma 02130
Replace existing atmospheric gas boiler with new high effeciency lochinvar kbn151 90% effecient boiler - side wall vented
Date:  February 18, 2011
Value:   $8,000
Contractor: Darren Chapman

Client: Monica Petri Trust | Permit type: Gas | Permit status: Expired | Current use: 1-2fam | Permit id: G64649 | Parcel: 1901913004
2011/02/18800010057 Burroughs St Boston Ma 02130Darren Chapman
SCORE
100
2 Wayburn Rd Boston Ma 02130
Replace one fixture.
Date:  January 11, 2010
Value:   $1
Contractor: Darren Chapman

Client: Hoener Clayton A | Permit type: Plumbing | Permit status: Expired | Current use: 1-7fam | Permit id: Pl10680 | Parcel: 1904571000
2010/01/1111002 Wayburn Rd Boston Ma 02130Darren Chapman
SCORE
100
138144 Lincoln St Boston Ma 02111
Install new furnace - lennox ml180uh110p48c - chimney vented 80% unit for the fifth floor living space. Also install lennox ml180uh110p48c furnace for the sixth floor living space.
Date:  February 6, 2014
Value:   $15,000
Contractor: Darren Chapman

Client: Lrjr Llc | Permit type: Gas | Permit status: Expired | Current use: 1-4fam | Permit id: G315878 | Parcel: 0304329000
2014/02/0615000100138144 Lincoln St Boston Ma 02111Darren Chapman
SCORE
100
7 Tremont St Boston Ma 02118
Install new lennox gwm-100ie -1 0 btu sidewall vented boiler with an indirect fired ss water heater
Date:  December 18, 2014
Value:   $550
Contractor: Darren Chapman

Client: Seven Tremont St Condo | Permit type: Gas | Permit status: Expired | Current use: 1-4fam | Permit id: G434109 | Parcel: 0900679000
2014/12/185501007 Tremont St Boston Ma 02118Darren Chapman
SCORE
100
Martin St Boston Ma 02132
Add small 1/2 bathroom to first floor
Date:  August 20, 2015
Value:   $1,500
Contractor: Darren Chapman

Client: Ayoub Gretchen T | Permit type: Plumbing | Permit status: Expired | Current use: 1-2fam | Permit id: Pl508389 | Parcel: 2002005000
2015/08/201500100Martin St Boston Ma 02132Darren Chapman
SCORE
100
6 Brigham St East Boston Ma 02128
Repalce water heater with new ruud pvp40 side wall vented 40 gallon wh
Date:  February 9, 2011
Value:   $1,200
Contractor: Darren Chapman

Client: Tremaine Russell F Ts | Permit type: Plumbing | Permit status: Expired | Current use: 1-3fam | Permit id: Pl63283 | Parcel: 0104600000
2011/02/0912001006 Brigham St East Boston Ma 02128Darren Chapman
SCORE
100
9 Concord Sq Boston Ma 02118
Remove and dispose of failed burnham boiler (backflow preventer) and obsolete rheem water heater - install new lochinvar kbn211 boiler and lochinvar sit0 - indirect water heater (permit for watts backflo boielr feeder and water piping / indirect water heater)
Date:  August 16, 2013
Value:   $5,000
Contractor: Darren Chapman

Client: Nine Concord Sq Condo Tr | Permit type: Plumbing | Permit status: Expired | Current use: 1-4fam | Permit id: Pl274915 | Parcel: 0402665000
2013/08/1650001009 Concord Sq Boston Ma 02118Darren Chapman
SCORE
100
1 Acorn St Boston Ma 02108
Replace 30 year old furnace with new chimney vented lennox gas furnace model # sl280uh135v60d / ... 135 0 btu input
Date:  August 13, 2015
Value:   $7,500
Contractor: Darren Chapman

Client: Roosevelt Candace C | Permit type: Gas | Permit status: Expired | Current use: 1-2fam | Permit id: G504394 | Parcel: 0501530000
2015/08/1375001001 Acorn St Boston Ma 02108Darren Chapman
SCORE
100
16 Durham St Boston Ma 02115
Replace existing boiler with new burnham p205 cast boielr chimney vented. Also see plumbing permit for watts boielr backflow device and new superstor ssu80 indirect water heater and realted potable piping...
Date:  October 7, 2013
Value:   $7,500
Contractor: Darren Chapman

Client: 16 Durham Condo Trust | Permit type: Gas | Permit status: Expired | Current use: 1-4fam | Permit id: G291714 | Parcel: 0400862000
2013/10/07750010016 Durham St Boston Ma 02115Darren Chapman
SCORE
100
3 Stoughton Street P Dorchester Ma 02125
Replace old chimney vented furnace with new sidewall (pvc) vented 0 btu lennox unit lennox slp98uh-070xv36b (97%afue)
Date:  May 31, 2016
Value:   $750
Contractor: Darren Chapman

Client: Boswell Zachary K | Permit type: Gas | Permit status: Expired | Current use: 1-2fam | Permit id: G597182 | Parcel: 1301366000
2016/05/317501003 Stoughton Street P Dorchester Ma 02125Darren Chapman
SCORE
100
189199 Forest Hills Boston Ma 02130
Remove and dispose of 3 existing 4th floor boilers supply and install 3 new lochinvar khn series gas boilers for "building group 4 195 197 199 forest hills 195 forest hills = khn285 197 forest hills = khn285 199 forest hills = khn155
Date:  September 6, 2016
Value:   $500
Contractor: Darren Chapman

Client: Forest Hills Housing Inc | Permit type: Gas | Permit status: Open | Current use: Multi | Permit id: G633641 | Parcel: 1102926000
2016/09/06500100189199 Forest Hills Boston Ma 02130Darren Chapman
SCORE
100
15 Jacob St Dorchester Ma 02124
Replace existing furnace with new lennox el296uh0415xv36 - 50mbh gas fired direct vented / sidewall vented furnace
Date:  December 6, 2012
Value:   $5,000
Contractor: Darren Chapman

Client: Daley Delcia I | Permit type: Gas | Permit status: Expired | Current use: 1-3fam | Permit id: G196773 | Parcel: 1403726000
2012/12/06500010015 Jacob St Dorchester Ma 02124Darren Chapman
SCORE
100
19 Charles River Sq Boston Ma 02114
Replace failed gas furnace with new gas furnace... 80% / chimney vented lennox sl280uh110v60c gas furnace
Date:  January 20, 2015
Contractor: Darren Chapman

Client: Nessen Beatrice | Permit type: Gas | Permit status: Expired | Current use: Multi | Permit id: G441176 | Parcel: 0502453000
2015/01/20010019 Charles River Sq Boston Ma 02114Darren Chapman
SCORE
100
29 Aldworth St Boston Ma 02130
Replace two very old oil fired "gurney" hydronic boilers. Replace with 2 new lochinvar kbn151 94% side wall vented hydronic boilers. - related gas fitting... 2 ea. @ 151 0 input
Date:  November 9, 2011
Value:   $15,000
Contractor: Darren Chapman

Client: Twenty 9 Aldworth St Condo | Permit type: Gas | Permit status: Expired | Current use: 1-2fam | Permit id: G103481 | Parcel: 1901725000
2011/11/091500010029 Aldworth St Boston Ma 02130Darren Chapman
SCORE
100
16 Durham St Boston Ma 02115
Water piping for a new superstor ssu80 indirect water heater and a watts boiler feed backflow device...
Date:  October 10, 2013
Value:   $5,000
Contractor: Darren Chapman

Client: 16 Durham Condo Trust | Permit type: Plumbing | Permit status: Expired | Current use: 1-4fam | Permit id: Pl291719 | Parcel: 0400862000
2013/10/10500010016 Durham St Boston Ma 02115Darren Chapman
SCORE
100
57 Burroughs St Boston Ma 02130
Install new watts 911 backflow device for new boiler installation (see gas permit) also install new lochinvar sit040indirect fired domestic hot water heater
Date:  February 18, 2011
Value:   $500
Contractor: Darren Chapman

Client: Monica Petri Trust | Permit type: Plumbing | Permit status: Expired | Current use: 1-2fam | Permit id: Pl64645 | Parcel: 1901913004
2011/02/1850010057 Burroughs St Boston Ma 02130Darren Chapman
SCORE
100
4 Boylston Pl Boston Ma 02116
Plumbing permit for backflow / boiler feed devices for two new boilers. One hydronic boiler = lochinvar kbn4 and one steam boiler = burnham k5006snei lochinvar to have watts backflow burnham to have backflow m/m water feeder / lwco
Date:  July 17, 2012
Value:   $1,500
Contractor: Darren Chapman

Client: The Tavern Club | Permit type: Plumbing | Permit status: Expired | Current use: Mixed | Permit id: Pl156608 | Parcel: 0500038000
2012/07/1715001004 Boylston Pl Boston Ma 02116Darren Chapman
SCORE
100
27 Devens St Charlestown Ma 02129
Install two new lochinvar kbn501 - condensing gas boilers as per norian-siani designs...
Date:  August 8, 2014
Value:   $5,000
Contractor: Darren Chapman

Client: Prot Epis Church Trs | Permit type: Gas | Current use: Comm | Permit id: G392220 | Parcel: 203782000
2014/08/08500010027 Devens St Charlestown Ma 02129Darren Chapman
SCORE
100
34 Myrtle St Boston Ma 02114
Plumbing permit for hydronic boiler backflow device - boiler is to support a dedicated / autonomous hydro-air heating system for the "penthouse" unit #5 @ 34 myrtle st.
Date:  May 19, 2010
Value:   $500
Contractor: Darren Chapman

Client: West End Trust | Permit type: Plumbing | Permit status: Expired | Current use: 1unit | Permit id: Pl25564 | Parcel: 0501880000
2010/05/1950010034 Myrtle St Boston Ma 02114Darren Chapman
SCORE
100
177181 Forest Hills Boston Ma 02130
3 watts 911s (or equivalent) boiler feed backflow devices (one pre boiler) 3 lochinvar boilers to be installed at "building 1" (177 179 181 forest hills st - j. P.)
Date:  September 6, 2016
Value:   $500
Contractor: Darren Chapman

Client: Forest Hills Housing Inc | Permit type: Plumbing | Permit status: Open | Current use: Multi | Permit id: Pl633644 | Parcel: 1102926000
2016/09/06500100177181 Forest Hills Boston Ma 02130Darren Chapman
SCORE
100
143 Perham St Boston Ma 02132
Rough in for basment bath group and laundry. Also replace chimney vented gas water heater with gallon indirect fired stainless steel water heater
Date:  June 27, 2013
Value:   $1,000
Contractor: Darren Chapman

Client: Iorio Alexander M | Permit type: Plumbing | Permit status: Expired | Current use: 1-2fam | Permit id: Pl230141 | Parcel: 2008271000
2013/06/271000100143 Perham St Boston Ma 02132Darren Chapman
SCORE
100
232 Beacon St Boston Ma 02116
Please note that work is at 230 beacon st - computer did not recognize #230 beacon as part of boiler replacement work install new backflow preventer and repalce glass lined chimney vented water heater with new ss indirect fired domestic hot water heater
Date:  September 22, 2014
Value:   $5,000
Contractor: Darren Chapman

Client: Arostegui - Ham Viviana Ts | Permit type: Plumbing | Permit status: Expired | Current use: 1-4fam | Permit id: Pl408729 | Parcel: 0502625000
2014/09/225000100232 Beacon St Boston Ma 02116Darren Chapman
SCORE
100
6 Brigham St East Boston Ma 02128
Repalce old atmospheric furnace with new lennox g61mpv-60c-091 side wall / direct vented condensing furnace
Date:  February 9, 2011
Value:   $5,000
Contractor: Darren Chapman

Client: Tremaine Russell F Ts | Permit type: Gas | Permit status: Expired | Current use: 1-3fam | Permit id: G63282 | Parcel: 0104600000
2011/02/0950001006 Brigham St East Boston Ma 02128Darren Chapman
SCORE
100
247 Commonwealth Av Boston Ma 02116
Gas fit for new furnace. New furnace to be lennox slp98uh135xv60d direct vented high efficiency gas unit... 135 000 btu input
Date:  August 18, 2014
Value:   $5,000
Contractor: Darren Chapman

Client: 247 Commonwealth Ave Condo Tr | Permit type: Gas | Permit status: Expired | Current use: 1-4fam | Permit id: G393146 | Parcel: 0503393000
2014/08/185000100247 Commonwealth Av Boston Ma 02116Darren Chapman
SCORE
100
34 Myrtle St Boston Ma 02114
Replace old economite gas conversion burner in very old smith mills boiler - using new carlin 250mbh input gas conversion burner
Date:  November 9, 2010
Value:   $4,000
Contractor: Darren Chapman

Client: West End Trust | Permit type: Gas | Permit status: Expired | Current use: 1-4fam | Permit id: G50295 | Parcel: 0501880000
2010/11/09400010034 Myrtle St Boston Ma 02114Darren Chapman
SCORE
100
27 Sunnyside St Boston Ma 02130
Repalce old chimney vented furnace with new lennox slp98uh090v48c side wall vented 90% high effeceincy gas furnace. 90mbh input
Date:  October 18, 2011
Value:   $5,000
Contractor: Darren Chapman

Client: Burgess Jane A | Permit type: Gas | Permit status: Expired | Current use: 1-2fam | Permit id: G99872 | Parcel: 1001966000
2011/10/18500010027 Sunnyside St Boston Ma 02130Darren Chapman
SCORE
100
995 Centre St Boston Ma 02130
Add new natural gas services and install a new lochinvar kbn151 high effeciency gas boiler (side wall vented) - also see plumbing permit for boiler backflow device and a lochinvar sit0 - gallon indirect fired domestic hot water heater
Date:  October 7, 2013
Value:   $10,000
Contractor: Darren Chapman

Client: Doty Constance | Permit type: Gas | Permit status: Expired | Current use: 1-2fam | Permit id: G291699 | Parcel: 1902502010
2013/10/0710000100995 Centre St Boston Ma 02130Darren Chapman
SCORE
100
29 Aldworth St Boston Ma 02130
Install two new lochinvar sit0 indirect fired ss water heaters (with two safety mix valves) as part of boiler installation listed on app# g103481
Date:  November 9, 2011
Value:   $5,000
Contractor: Darren Chapman

Client: Twenty 9 Aldworth St Condo | Permit type: Plumbing | Permit status: Expired | Current use: 1-2fam | Permit id: Pl103485 | Parcel: 1901725000
2011/11/09500010029 Aldworth St Boston Ma 02130Darren Chapman
SCORE
100
234 Beacon St Boston Ma 02116
Convert oil burner to new gas burner (beckett 600 000 btu input burner)- includes new gas fitting from boiler room burner to new meter location on dartmouth st side of building
Date:  October 7, 2013
Value:   $12,000
Contractor: Darren Chapman

Client: Two 34 Beacon St Condo Tr | Permit type: Gas | Permit status: Expired | Current use: Multi | Permit id: G291683 | Parcel: 0502626000
2013/10/0712000100234 Beacon St Boston Ma 02116Darren Chapman
SCORE
100
42 Irving St Boston Ma 02114
Remove existing problematic weil mclain gas boiler and install new lochinvar kbn151 151 0 btu input high efficeincy sidewall vented gas boiler
Date:  May 14, 2015
Contractor: Darren Chapman

Client: Walton Nathaniel Y | Permit type: Gas | Permit status: Expired | Current use: 1-2fam | Permit id: G470461 | Parcel: 0300217000
2015/05/14010042 Irving St Boston Ma 02114Darren Chapman
SCORE
100
11 Rhoda St Boston Ma 02132
Repalce failed gas furnace new condensing 90% lennox g61mpv-36b-071 furnace ( 000btu input)
Date:  April 27, 2010
Value:   $4,500
Contractor: Darren Chapman

Client: Moran Jennifer | Permit type: Gas | Permit status: Expired | Current use: 1-2fam | Permit id: G22544 | Parcel: 2005703000
2010/04/27450010011 Rhoda St Boston Ma 02132Darren Chapman
SCORE
100
39 W Cedar St Boston Ma 02114
Permit to replace boiler feed / watts backflow device (911s) as we replace existing failed boiler with new lennox gwb-07e gas fired boiler
Date:  April 11, 2011
Value:   $500
Contractor: Darren Chapman

Client: Minton Therese S | Permit type: Plumbing | Permit status: Expired | Current use: 1-3fam | Permit id: Pl71031 | Parcel: 0501857000
2011/04/1150010039 W Cedar St Boston Ma 02114Darren Chapman
SCORE
100
6769 Brookley Rd Boston Ma 02130
Gas permit for four lochinvar kbn081 (81 0 btus input each. Replace four old cast iron chimney vented small boilers and install new sidewall vented high effeceincy boilers and four lochivnar sit0 ( gallon) indirect water heaters (see also plumbing permit app # pl3436 fro water heater and boiler backflow device permit)
Date:  March 18, 2014
Value:   $20,000
Contractor: Darren Chapman

Client: Kilgore James R | Permit type: Gas | Permit status: Expired | Current use: 1-4fam | Permit id: G343618 | Parcel: 1102684000
2014/03/18200001006769 Brookley Rd Boston Ma 02130Darren Chapman
SCORE
100
1 Murdock Te Brighton Ma 02135
Plumbing pemit for boiler replacement backflow device - see also gas permit for same...
Date:  February 18, 2011
Value:   $750
Contractor: Darren Chapman

Client: Erlacher Heidi A | Permit type: Plumbing | Current use: 1-2fam | Permit id: Pl63936 | Parcel: 2147483647
2011/02/187501001 Murdock Te Brighton Ma 02135Darren Chapman
SCORE
100
1 Salem St Boston Ma 02113
Replace failed gas boiler with new twin / new lochivar kbn151 (151 0 btu input) high effeceincy boilers. New boilers to be properly vented via twin new 3" ss chimney liners (liners by billy sweet chimney sweeps)
Date:  January 13, 2014
Value:   $2,500
Contractor: Darren Chapman

Client: Yip Collin Chun Yin Ts | Permit type: Gas | Permit status: Expired | Current use: Mixed | Permit id: G318444 | Parcel: 0301335000
2014/01/1325001001 Salem St Boston Ma 02113Darren Chapman
SCORE
100
Monmouth St East Boston Ma 02128
Two new lohcinvar high effeciency - side wall vented gas boilers. First floor to recieve a lochinvar kbn106 (106 0 btu input) boiler. Second floor to recieve a lochinvar kbn151 (151 0 btu input) boiler.
Date:  October 10, 2013
Value:   $10,000
Contractor: Darren Chapman

Client: Bonney Jonathan R | Permit type: Gas | Permit status: Expired | Current use: 1-2fam | Permit id: G291737 | Parcel: 0102751000
2013/10/1010000100Monmouth St East Boston Ma 02128Darren Chapman
SCORE
100
1 Murdock Te Brighton Ma 02135
Gas fitting and pvc venting (sidewall) for boiler replacement. New boiler to be lochinvar kbn151.... 150mbh input
Date:  February 18, 2011
Value:   $750
Contractor: Darren Chapman

Client: Erlacher Heidi A | Permit type: Gas | Permit status: Expired | Current use: 1-2fam | Permit id: G63932 | Parcel: 2147483647
2011/02/187501001 Murdock Te Brighton Ma 02135Darren Chapman
SCORE
100
183187 Forest Hills Boston Ma 02130
Replace 3-boilers 3-backflow bldg. Two 183 185 and 187
Date:  September 6, 2016
Value:   $500
Contractor: Darren Chapman

Client: Forest Hills Housing Inc | Permit type: Plumbing | Permit status: Open | Current use: Multi | Permit id: Pl633655 | Parcel: 1102926000
2016/09/06500100183187 Forest Hills Boston Ma 02130Darren Chapman
SCORE
100
Bourne St Boston Ma 02130
Install new (nat. Grid / freedom boiler # fcm120m - sidewall vented) boiler permit for gas piping and proper flue venting
Date:  April 1, 2010
Value:   $3,000
Contractor: Darren Chapman

Client: Knopf-Goldner Mark A | Permit type: Gas | Permit status: Expired | Current use: 1-2fam | Permit id: G19773 | Parcel: 1904531000
2010/04/013000100Bourne St Boston Ma 02130Darren Chapman
SCORE
100
189199 Forest Hills Boston Ma 02130
Remove and dispose of 3 existing 4th floor boilers supply and install 2 lochinvar khn199 boilers & 1 lochinvar khn285 189 forest hills st = khn199 191 forest hills st = khn285 193 forest hills st = khn199
Date:  September 6, 2016
Value:   $500
Contractor: Darren Chapman

Client: Forest Hills Housing Inc | Permit type: Gas | Permit status: Open | Current use: Multi | Permit id: G633636 | Parcel: 1102926000
2016/09/06500100189199 Forest Hills Boston Ma 02130Darren Chapman
SCORE
100
8 Oriole St Boston Ma 02132
Replace water heater.
Date:  February 11, 2010
Contractor: Darren Chapman

Client: Crowley Sean T | Permit type: Gas | Permit status: Expired | Current use: 1-7fam | Permit id: G14020 | Parcel: 2002148000
2010/02/1101008 Oriole St Boston Ma 02132Darren Chapman
SCORE
100
Mendum St Roslindale Ma 02131
Pipe in a new gas fireplace
Date:  April 27, 2010
Value:   $1,000
Contractor: Darren Chapman

Client: Glidden Kenneth A Etal | Permit type: Gas | Permit status: Expired | Current use: 1-2fam | Permit id: G23291 | Parcel: 2005333000
2010/04/271000100Mendum St Roslindale Ma 02131Darren Chapman
SCORE
100
183187 Forest Hills Boston Ma 02130
Remove and dispose of 3 gas boilers; supply and install 3 new lochinvar boilers in "building 2" block 183 forest hills st = lochinvar khn285 185 forest hills st = lochinvar khn285 187 forest hills st = lochinvar khn199
Date:  September 6, 2016
Value:   $500
Contractor: Darren Chapman

Client: Forest Hills Housing Inc | Permit type: Gas | Permit status: Open | Current use: Multi | Permit id: G633630 | Parcel: 1102926000
2016/09/06500100183187 Forest Hills Boston Ma 02130Darren Chapman
SCORE
100
143 Perham St Boston Ma 02132
Remove existing chimney vented boiler. Install new lochinvar kbn151 side wall vented category iv 95% high effeciency ss gas boiler
Date:  July 9, 2013
Value:   $5,000
Contractor: Darren Chapman

Client: Iorio Alexander M | Permit type: Gas | Permit status: Expired | Current use: 1-2fam | Permit id: G230152 | Parcel: 2008271000
2013/07/095000100143 Perham St Boston Ma 02132Darren Chapman
SCORE
100
39 W Cedar St Boston Ma 02114
Nipple fit (gas) to replace existing failed lennox boiler with new / same lennox boiler model number gwb-07e (37 500btu input)
Date:  April 11, 2011
Value:   $500
Contractor: Darren Chapman

Client: Minton Therese S | Permit type: Gas | Permit status: Expired | Current use: 1-3fam | Permit id: G71028 | Parcel: 0501857000
2011/04/1150010039 W Cedar St Boston Ma 02114Darren Chapman
SCORE
100
177181 Forest Hills Boston Ma 02130
Remove and dispose of existing high efficiency gas boiler. Supply and install new lochinvar khn155 high efficiency gas boiler for building 177 remove and dispose of existing high efficiency gas boiler. Supply and install new lochinvar khn285 high efficiency gas boiler for buildings 179 & 181 3 boilers for 177-181 forest hill st "building 1"
Date:  September 6, 2016
Value:   $500
Contractor: Darren Chapman

Client: Forest Hills Housing Inc | Permit type: Gas | Permit status: Open | Current use: Multi | Permit id: G633624 | Parcel: 1102926000
2016/09/06500100177181 Forest Hills Boston Ma 02130Darren Chapman
SCORE
100
27 Devens St Charlestown Ma 02129
Backflow preventers for twin boiler feeds (two lochinvar kbn501 boilers)
Date:  August 8, 2014
Value:   $5,000
Contractor: Darren Chapman

Client: Prot Epis Church Trs | Permit type: Plumbing | Current use: Comm | Permit id: Pl392233 | Parcel: 203782000
2014/08/08500010027 Devens St Charlestown Ma 02129Darren Chapman
SCORE
100
28 Marlborough St Boston Ma
Replace existing boiler with new buderus g234x55 atmospheric gas boiler 228 0 input cast iron boiler
Date:  November 2, 2010
Value:   $8,000
Contractor: Darren Chapman

Permit type: Gas permit | Expiration date: May 2, 2011 | Current use: 1-4fam | Permit id: G49792 | Parcel: 0502842000
2010/11/02800010028 Marlborough St Boston MaDarren Chapman
SCORE
100
42 Irving St Boston Ma
Boiler replacement - new watts 911 backflow
Date:  May 14, 2015
Contractor: Darren Chapman

Client: Fitzgerald John I | Permit type: Plumbing permit | Expiration date: November 14, 2015 | Current use: 1-2fam | Permit id: Pl470465 | Parcel: 0300217000
2015/05/14010042 Irving St Boston MaDarren Chapman
SCORE
100
42 Irving St Boston Ma
Remove existing problematic weil mclain gas boiler and install new lochinvar kbn151 151 0 btu input high efficeincy sidewall vented gas boiler
Date:  May 14, 2015
Contractor: Darren Chapman

Client: Fitzgerald John I | Permit type: Gas permit | Expiration date: November 14, 2015 | Current use: 1-2fam | Permit id: G470461 | Parcel: 0300217000
2015/05/14010042 Irving St Boston MaDarren Chapman
SCORE
100
29 Aldworth St Boston Ma
Replace two very old oil fired "gurney" hydronic boilers. Replace with 2 new lochinvar kbn151 94% side wall vented hydronic boilers. - related gas fitting... 2 ea. @ 151 0 input
Date:  November 9, 2011
Value:   $15,000
Contractor: Darren Chapman

Client: Fay John J Jr | Permit type: Gas permit | Expiration date: May 9, 2012 | Current use: 1-2fam | Permit id: G103481 | Parcel: 1901725000
2011/11/091500010029 Aldworth St Boston MaDarren Chapman
SCORE
100
34 Myrtle St Boston Ma
Replace old economite gas conversion burner in very old smith mills boiler - using new carlin 250mbh input gas conversion burner
Date:  November 9, 2010
Value:   $4,000
Contractor: Darren Chapman

Client: West End Trust | Permit type: Gas permit | Expiration date: May 9, 2011 | Current use: 1-4fam | Permit id: G50295 | Parcel: 0501880000
2010/11/09400010034 Myrtle St Boston MaDarren Chapman
SCORE
100
Monmouth St East Boston Ma
Two new lohcinvar high effeciency - side wall vented gas boilers. First floor to recieve a lochinvar kbn106 (106 0 btu input) boiler. Second floor to recieve a lochinvar kbn151 (151 0 btu input) boiler.
Date:  October 10, 2013
Value:   $10,000
Contractor: Darren Chapman

Client: Bonney | Permit type: Gas permit | Expiration date: April 10, 2014 | Current use: 1-2fam | Permit id: G291737 | Parcel: 0102751000
2013/10/1010000100Monmouth St East Boston MaDarren Chapman
SCORE
100
13 15 Worcester Sq Boston Ma
Remove and dispose of two existing atmospheric gas boilers (burnham) supply and install two new lochivnar kbn286 boilers with two new sit0 indirect fired domestic hot water heaters... Include twin stainless steel chimney liners (one for each boiler) total gas input = 572 0 btus
Date:  August 16, 2013
Value:   $1,500
Contractor: Darren Chapman

Permit type: Gas permit | Expiration date: February 16, 2014 | Current use: 1-4fam | Permit id: G275508 | Parcel: 0801510010
2013/08/16150010013 15 Worcester Sq Boston MaDarren Chapman
SCORE
100
Monmouth St East Boston Ma
Install two indirect fired water heaters and two boielr backflow devices
Date:  October 10, 2013
Value:   $5,000
Contractor: Darren Chapman

Client: Bonney | Permit type: Plumbing permit | Expiration date: April 10, 2014 | Current use: 1-2fam | Permit id: Pl291752 | Parcel: 0102751000
2013/10/105000100Monmouth St East Boston MaDarren Chapman
SCORE
100
27 Devens St Charlestown Ma
Install two new lochinvar kbn501 - condensing gas boilers as per norian-siani designs...
Date:  August 8, 2014
Value:   $5,000
Contractor: Darren Chapman

Client: Prot Epis Church Trs | Permit type: Gas permit | Expiration date: February 8, 2015 | Current use: Comm | Permit id: G392220 | Parcel: 0203782000
2014/08/08500010027 Devens St Charlestown MaDarren Chapman
SCORE
100
19 Louisburg Sq Boston Ma
Replace year old gas boielr with twin new burnham p205 1 0 btu input boilers
Date:  September 17, 2014
Value:   $1,000
Contractor: Darren Chapman

Client: Smith Linda K | Permit type: Gas permit | Expiration date: March 17, 2015 | Current use: 1-2fam | Permit id: G404282 | Parcel: 0501651110
2014/09/17100010019 Louisburg Sq Boston MaDarren Chapman
SCORE
100
228 2 Beacon St Boston Ma
Please note that work is at 2 beacon st - computer did not allow #2 beacon / used 232 replace old cast iron boiler with new lochinvar ftxl high efficiency boiler. Boiler is to be vented to roof via ss (fas n seal) approved flue piping system. Gas infrastructure (for old boiler) already in place... (combustion air from side wall of building / pvc intake)
Date:  September 22, 2014
Value:   $15,000
Contractor: Darren Chapman

Client: Beacon Waterside Condo Trust | Permit type: Gas permit | Expiration date: March 22, 2015 | Current use: 1-4fam | Permit id: G408727 | Parcel: 0502624000
2014/09/2215000100228 2 Beacon St Boston MaDarren Chapman
SCORE
100
67 69 Brookley Rd Boston Ma
Remove and dispose of four chimney vented domestic hot water heaters. Supply and install four - lochinvar sit0 - gallon indirect fired ss water heaters. Also see gas permit fro four lochihnvar boilers - kbn081 - 81 0 btus each (plumbing permit for four watts 911 backflow devices / one for each boiler)
Date:  March 18, 2014
Value:   $10,000
Contractor: Darren Chapman

Client: Blake Peter | Permit type: Plumbing permit | Expiration date: September 18, 2014 | Current use: 1-4fam | Permit id: Pl343610 | Parcel: 1102684000
2014/03/181000010067 69 Brookley Rd Boston MaDarren Chapman
SCORE
100
9 Concord Sq Boston Ma
Replace failed burnham boiler with new lochinvar kbn211 boiler and also install new lochinvar sit0 indirect fired domestic hot water heater
Date:  August 15, 2013
Value:   $1,500
Contractor: Darren Chapman

Permit type: Gas permit | Expiration date: February 15, 2014 | Current use: 1-4fam | Permit id: G274907 | Parcel: 0402665000
2013/08/1515001009 Concord Sq Boston MaDarren Chapman
SCORE
100
4 Walk Hill St Dorchester Ma
Remove and dispose of failed trianco "heatmaker" boiler and indirect glass lined hot water heater. Install a new lochinvar whn1 (1 btu input) high effeciency - side wall vented boiler and matching stianless steel indirect water heater model number sit0 - gallon indirect
Date:  November 12, 2012
Value:   $1,500
Contractor: Darren Chapman

Permit type: Gas permit | Expiration date: May 12, 2013 | Current use: 1-2fam | Permit id: G181198
2012/11/1215001004 Walk Hill St Dorchester MaDarren Chapman
SCORE
100
1 Murdock Te Brighton Ma
Gas fitting and pvc venting (sidewall) for boiler replacement. New boiler to be lochinvar kbn151.... 150mbh input
Date:  February 18, 2011
Value:   $750
Contractor: Darren Chapman

Client: Erlacher Heidi | Permit type: Gas permit | Expiration date: August 18, 2011 | Current use: 1-2fam | Permit id: G63932 | Parcel: 2202002000
2011/02/187501001 Murdock Te Brighton MaDarren Chapman
SCORE
100
67 69 Brookley Rd Boston Ma
Gas permit for four lochinvar kbn081 (81 0 btus input each. Replace four old cast iron chimney vented small boilers and install new sidewall vented high effeceincy boilers and four lochivnar sit0 ( gallon) indirect water heaters (see also plumbing permit app # pl3436 fro water heater and boiler backflow device permit)
Date:  March 18, 2014
Value:   $20,000
Contractor: Darren Chapman

Client: Blake Peter | Permit type: Gas permit | Expiration date: September 18, 2014 | Current use: 1-4fam | Permit id: G343618 | Parcel: 1102684000
2014/03/182000010067 69 Brookley Rd Boston MaDarren Chapman
SCORE
100
27 Devens St Charlestown Ma
Backflow preventers for twin boiler feeds (two lochinvar kbn501 boilers)
Date:  August 8, 2014
Value:   $5,000
Contractor: Darren Chapman

Client: Prot Epis Church Trs | Permit type: Plumbing permit | Expiration date: February 8, 2015 | Current use: Comm | Permit id: Pl392233 | Parcel: 0203782000
2014/08/08500010027 Devens St Charlestown MaDarren Chapman
SCORE
100
4 Walk Hill St Dorchester Ma
Install water heater and modified piping for new lochinvar sit0 gallon indirect hot watewr heater. Install watts 911s backflow boielr feed device for new lochinvar whn1 gas boiler
Date:  November 12, 2012
Value:   $1,500
Contractor: Darren Chapman

Permit type: Plumbing permit | Expiration date: May 12, 2013 | Current use: 1-2fam | Permit id: Pl181199
2012/11/1215001004 Walk Hill St Dorchester MaDarren Chapman
SCORE
100
31 Parkton Rd Boston Ma
Delete existing steam boiler and steam piping infrastructure. Supply and install a new lennox el195uh070xe36b ( 0 btu input) gas furnace - side wall vented...
Date:  February 26, 2014
Value:   $6,500
Contractor: Darren Chapman

Client: Moynihan John | Permit type: Gas permit | Expiration date: August 26, 2014 | Current use: 1-3fam | Permit id: G322097 | Parcel: 1002126000
2014/02/26650010031 Parkton Rd Boston MaDarren Chapman
SCORE
100
247 Commonwealth Av Boston Ma
Gas fit for new furnace. New furnace to be lennox slp98uh135xv60d direct vented high efficiency gas unit... 135 0 btu input
Date:  August 18, 2014
Value:   $5,000
Contractor: Darren Chapman

Permit type: Gas permit | Expiration date: February 18, 2015 | Current use: 1-4fam | Permit id: G393146 | Parcel: 0503393000
2014/08/185000100247 Commonwealth Av Boston MaDarren Chapman
SCORE
100
663a E Fifth St South Boston Ma
Correct pvc flue piping that is not per code or manufacturers specifications
Date:  October 31, 2012
Value:   $3,600
Contractor: Darren Chapman

Permit type: Gas permit | Expiration date: April 30, 2013 | Current use: 1-3fam | Permit id: G189931
2012/10/313600100663a E Fifth St South Boston MaDarren Chapman
SCORE
100
6 E Sixth St South Boston Ma
Replace existing boiler with new lochinvar kbn106 high effeciency gas boiler. Include a lochinvar sit0 indirect fired domestic hot water heater adn safety mix valve. Minor water piping to accomodate this new water heater and boiler backflow preventer (watts 911)
Date:  August 30, 2012
Value:   $1,500
Contractor: Darren Chapman

Client: Morgan Joan F | Permit type: Plumbing permit | Expiration date: February 28, 2013 | Current use: 1-2fam | Permit id: Pl174589 | Parcel: 0602436000
2012/08/3015001006 E Sixth St South Boston MaDarren Chapman
SCORE
100
143 Perham St Boston Ma
Remove existing chimney vented boiler. Install new lochinvar kbn151 side wall vented category iv 95% high effeciency ss gas boiler
Date:  July 9, 2013
Value:   $5,000
Contractor: Darren Chapman

Client: Sullivan Richar | Permit type: Gas permit | Expiration date: January 9, 2014 | Current use: 1-2fam | Permit id: G230152 | Parcel: 2008271000
2013/07/095000100143 Perham St Boston MaDarren Chapman
SCORE
100
7 Tremont St Boston Ma
Install new lennox gwm-100ie -1 0 btu sidewall vented boiler with an indirect fired ss water heater
Date:  December 18, 2014
Value:   $550
Contractor: Darren Chapman

Permit type: Gas permit | Expiration date: June 18, 2015 | Current use: 1-4fam | Permit id: G434109 | Parcel: 0900679000
2014/12/185501007 Tremont St Boston MaDarren Chapman
SCORE
100
86 Moss Hill Rd Boston Ma
Permit for new boiler backflow device (watts 911) and for new indirect fired domestic hot water heater
Date:  October 24, 2013
Value:   $1,500
Contractor: Darren Chapman

Client: Durrane Walter | Permit type: Plumbing permit | Expiration date: April 24, 2014 | Current use: 1-2fam | Permit id: Pl295325 | Parcel: 1902475000
2013/10/24150010086 Moss Hill Rd Boston MaDarren Chapman
SCORE
100
4 Monument Sq Charlestown Ma
Remove and dispose of existing indirect (oil) fired water heater. Supply and install a new superstor ssu119 indirect fired water heater along with a new lochinvar kbn211 hot water boiler (backflow device)
Date:  August 16, 2013
Value:   $5,000
Contractor: Darren Chapman

Client: Carlton House Condo | Permit type: Plumbing permit | Expiration date: February 16, 2014 | Current use: 1-4fam | Permit id: Pl275398 | Parcel: 0203387000
2013/08/1650001004 Monument Sq Charlestown MaDarren Chapman
SCORE
100
143 Perham St Boston Ma
Rough in for basment bath group and laundry. Also replace chimney vented gas water heater with gallon indirect fired stainless steel water heater
Date:  June 27, 2013
Value:   $1,000
Contractor: Darren Chapman

Client: Sullivan Richar | Permit type: Plumbing permit | Expiration date: December 27, 2013 | Current use: 1-2fam | Permit id: Pl230141 | Parcel: 2008271000
2013/06/271000100143 Perham St Boston MaDarren Chapman
SCORE
100
25 Holbrook St Boston Ma
Remove old oil fired furnace and install new 97% high effeciency lennox furnace. Install lennox slp98uh090v48c - 0 btu
Date:  September 6, 2011
Value:   $8,000
Contractor: Darren Chapman

Client: Frank Eric | Permit type: Gas permit | Expiration date: March 6, 2012 | Current use: 1-2fam | Permit id: G91739 | Parcel: 1901792000
2011/09/06800010025 Holbrook St Boston MaDarren Chapman
SCORE
100
16 24 Union Park St Boston Ma
Install new lochinvar sit0 - gallon ss indirect water heater (along with new boiler and new boiler watts 911 backflow device
Date:  August 15, 2013
Value:   $4,000
Contractor: Darren Chapman

Permit type: Plumbing permit | Expiration date: February 15, 2014 | Current use: 1-4fam | Permit id: Pl262679 | Parcel: 0305961000
2013/08/15400010016 24 Union Park St Boston MaDarren Chapman
SCORE
100
29 Aldworth St Boston Ma
Install two new lochinvar sit0 indirect fired ss water heaters (with two safety mix valves) as part of boiler installation listed on app# g103481
Date:  November 9, 2011
Value:   $5,000
Contractor: Darren Chapman

Client: Fay John J Jr | Permit type: Plumbing permit | Expiration date: May 9, 2012 | Current use: 1-2fam | Permit id: Pl103485 | Parcel: 1901725000
2011/11/09500010029 Aldworth St Boston MaDarren Chapman
SCORE
100
80 82 A St South Boston Ma
Address we have is 52 athens st #4 per richard chung (it person @ isd) use 80a st as athens ais on corner with a st.... Remove existing weather king furnace - install new 95% afue lennox gas furnace (45mbh input) - sidewall vented / direct vent appliance
Date:  January 22, 2014
Value:   $5,500
Contractor: Darren Chapman

Client: A St Condo | Permit type: Gas permit | Expiration date: July 22, 2014 | Current use: Multi | Permit id: G319153 | Parcel: 0601197010
2014/01/22550010080 82 A St South Boston MaDarren Chapman
SCORE
100
19 Louisburg Sq Boston Ma
Replacing heating boiler - new backflow device shall be installed (twin new burnham p205 boilers) - see also gas permit # g404282
Date:  September 17, 2014
Value:   $1,000
Contractor: Darren Chapman

Client: Smith Linda K | Permit type: Plumbing permit | Expiration date: March 17, 2015 | Current use: 1-2fam | Permit id: Pl404284 | Parcel: 0501651110
2014/09/17100010019 Louisburg Sq Boston MaDarren Chapman
SCORE
100
6 Brigham St East Boston Ma
Repalce water heater with new ruud pvp side wall vented gallon wh
Date:  February 9, 2011
Value:   $1,200
Contractor: Darren Chapman

Client: Tremaine Russell F | Permit type: Plumbing permit | Expiration date: August 9, 2011 | Current use: 1-3fam | Permit id: Pl63283 | Parcel: 0104600000
2011/02/0912001006 Brigham St East Boston MaDarren Chapman
SCORE
100
995 Centre St Boston Ma
Add new natural gas services and install a new lochinvar kbn151 high effeciency gas boiler (side wall vented) - also see plumbing permit for boiler backflow device and a lochinvar sit0 - gallon indirect fired domestic hot water heater
Date:  October 7, 2013
Value:   $10,000
Contractor: Darren Chapman

Client: Doty Constance | Permit type: Gas permit | Expiration date: April 7, 2014 | Current use: 1-2fam | Permit id: G291699 | Parcel: 1902502010
2013/10/0710000100995 Centre St Boston MaDarren Chapman
SCORE
100
995 Centre St Boston Ma
Install new lochinvar kbn151 high effeciency gas boiler (watts 911 backflow device) and water piping to and from new lochinvar sit0 - gallon ss indirect fired domestic hot water heater
Date:  October 10, 2013
Value:   $5,000
Contractor: Darren Chapman

Client: Doty Constance | Permit type: Plumbing permit | Expiration date: April 10, 2014 | Current use: 1-2fam | Permit id: Pl291704 | Parcel: 1902502010
2013/10/105000100995 Centre St Boston MaDarren Chapman
SCORE
100
19 Commonwealth Av Brighton Ma
Repalce failed furnace with new lennoxml180uh070e36b chimney vented (80% category i) furnace
Date:  March 27, 2013
Value:   $4,500
Contractor: Darren Chapman

Permit type: Gas permit | Expiration date: September 27, 2013 | Current use: Multi | Permit id: G230333
2013/03/27450010019 Commonwealth Av Brighton MaDarren Chapman
SCORE
100
7 Tremont St Boston Ma
Install new lochinvar ss indirect water heater model; sit0 - gallon unit also install watts 911s combination fill and backflow device for new boiler feed
Date:  December 18, 2014
Contractor: Darren Chapman

Permit type: Plumbing permit | Expiration date: June 18, 2015 | Current use: 1-4fam | Permit id: Pl434111 | Parcel: 0900679000
2014/12/1801007 Tremont St Boston MaDarren Chapman
SCORE
100
5 Prescott St Charlestown Ma
Replace existing 80% gas furnace with new high effeceincy carrier furnace. Install carrier 58uvb080-1-14 - 80mbh input furnace
Date:  April 4, 2011
Value:   $9,000
Contractor: Darren Chapman

Permit type: Gas permit | Expiration date: October 4, 2011 | Current use: 1-2fam | Permit id: G69224 | Parcel: 0203776000
2011/04/0490001005 Prescott St Charlestown MaDarren Chapman
SCORE
100
107 Greaton Rd Boston Ma
Plumbing permit for minor water piping to backflow preventer for boielr and water piping for indirect fired water heater
Date:  August 15, 2013
Value:   $1,500
Contractor: Darren Chapman

Client: Herring Nancy | Permit type: Plumbing permit | Expiration date: February 15, 2014 | Current use: 1-2fam | Permit id: Pl262994 | Parcel: 2006123000
2013/08/151500100107 Greaton Rd Boston MaDarren Chapman
SCORE
100
25 Wales St Dorchester Ma
Replace existing utica steam boiler with new utica peg187c steam boiler (187 000btu input)
Date:  August 3, 2011
Value:   $4,500
Contractor: Darren Chapman

Client: Austin Richard | Permit type: Gas permit | Expiration date: February 3, 2012 | Current use: 1-2fam | Permit id: G77580 | Parcel: 1401943000
2011/08/03450010025 Wales St Dorchester MaDarren Chapman
SCORE
100
1 Murdock Te Brighton Ma
Plumbing pemit for boiler replacement backflow device - see also gas permit for same...
Date:  February 18, 2011
Value:   $750
Contractor: Darren Chapman

Client: Erlacher Heidi | Permit type: Plumbing permit | Expiration date: August 18, 2011 | Current use: 1-2fam | Permit id: Pl63936 | Parcel: 2202002000
2011/02/187501001 Murdock Te Brighton MaDarren Chapman
SCORE
100
186 W Brookline St Boston Ma
Replace old rooftop unit with new 000mbh unput lennox 15gcsxav-36-0 rooftop heat cool unit
Date:  September 15, 2011
Value:   $3,500
Contractor: Darren Chapman

Client: Minturn Robert B Jr | Permit type: Gas permit | Expiration date: March 15, 2012 | Current use: 1-2fam | Permit id: G92552 | Parcel: 0400524000
2011/09/153500100186 W Brookline St Boston MaDarren Chapman
SCORE
100
16 24 Union Park St Boston Ma
Remove and dispose of existing weil mclain chimney vented / atmospheric gas boiler. Install a new lochinvar kbn211 (2 btu input) high effeceincy gas boiler. Line chimney with approved fas n seal ss chimney liner (3") also install a lochinvar sit0 / gallon ss indirect fired domestic hot water heater
Date:  August 15, 2013
Value:   $1,500
Contractor: Darren Chapman

Permit type: Gas permit | Expiration date: February 15, 2014 | Current use: 1-4fam | Permit id: G262657 | Parcel: 0305961000
2013/08/15150010016 24 Union Park St Boston MaDarren Chapman
SCORE
100
8 Rutland Sq Boston Ma
Gas fitting nipples valve etc for new furnace installation (replacement) installing lennox ml180-090p48b... 90mbh input furnace
Date:  April 14, 2011
Value:   $250
Contractor: Darren Chapman

Client: Morrison Steven | Permit type: Gas permit | Expiration date: October 14, 2011 | Current use: 1-4fam | Permit id: G72025 | Parcel: 0402717010
2011/04/142501008 Rutland Sq Boston MaDarren Chapman
SCORE
100
4 Monument Sq Charlestown Ma
Remove and dispose of old oil fired boiler. Install new gas service for new gas fired boiler - lochinvar kbn211 (211 0 btu input)... Gas pipipng will be less than ten feet developed length from exterior meter to interior boiler location...
Date:  August 16, 2013
Value:   $1,500
Contractor: Darren Chapman

Client: Carlton House Condo | Permit type: Gas permit | Expiration date: February 16, 2014 | Current use: 1-4fam | Permit id: G275390 | Parcel: 0203387000
2013/08/1615001004 Monument Sq Charlestown MaDarren Chapman
SCORE
100
247 Commonwealth Av Boston Ma
Replacement of furnace in basement
Date:  September 21, 2016
Value:   $500
Contractor: Darren Chapman

Client: Two 47 Commonwealth Avenue | Permit type: Gas permit | Expiration date: March 21, 2017 | Current use: 1-4fam | Permit id: G636319 | Parcel: 0503393000
2016/09/21500100247 Commonwealth Av Boston MaDarren Chapman
SCORE
100
1012 Colgate Rd Roslindale Ma
Backflow for boiler
Date:  September 21, 2016
Value:   $500
Contractor: Darren Chapman

Client: Ten-Twelve Colgate Road | Permit type: Plumbing permit | Expiration date: March 21, 2017 | Current use: 1-3fam | Permit id: Pl637071 | Parcel: 1902913000
2016/09/215001001012 Colgate Rd Roslindale MaDarren Chapman
SCORE
100
1012 Colgate Rd Roslindale Ma
Replace failed gas (steam) boiler...
Date:  September 27, 2016
Value:   $500
Contractor: Darren Chapman

Client: Ten-Twelve Colgate Road | Permit type: Gas permit | Expiration date: March 27, 2017 | Current use: 1-3fam | Permit id: G634267 | Parcel: 1902913000
2016/09/275001001012 Colgate Rd Roslindale MaDarren Chapman
SCORE
100
Washington St Brighton Ma
Replacement of roof top unit
Date:  October 18, 2016
Value:   $24,820
Contractor: Darren Chapman

Client: Bnai Brith Sr Citizens | Permit type: Gas permit | Expiration date: April 18, 2017 | Current use: Multi | Permit id: G646554 | Parcel: 2101991000
2016/10/1824820100Washington St Brighton MaDarren Chapman
SCORE
100
34 Arborway Boston Ma
Back-flow for boiler and indirect water heater
Date:  October 26, 2016
Value:   $12,800
Contractor: Darren Chapman

Client: Butts Jeff | Permit type: Plumbing permit | Expiration date: April 26, 2017 | Current use: 1-2fam | Permit id: Pl650352 | Parcel: 1901591000
2016/10/261280010034 Arborway Boston MaDarren Chapman
SCORE
100
34 Arborway Boston Ma
Replace gas boiler with 95% lochinvar boiler and indirect gallon water heater
Date:  October 26, 2016
Value:   $21,800
Contractor: Darren Chapman

Client: Butts Jeff | Permit type: Gas permit | Expiration date: April 26, 2017 | Current use: 1-2fam | Permit id: G650351 | Parcel: 1901591000
2016/10/262180010034 Arborway Boston MaDarren Chapman
SCORE
100
3535c Middle St South Boston Ma
Replacing roof top unit
Date:  November 1, 2016
Value:   $500
Contractor: Darren Chapman

Permit type: Gas permit | Expiration date: May 1, 2017 | Current use: 1-2fam | Permit id: G652788
2016/11/015001003535c Middle St South Boston MaDarren Chapman
SCORE
100
234236 S Huntington Boston Ma
Install new gallon ruud chimney vented glass lined water heater
Date:  May 9, 2016
Value:   $1,500
Contractor: Darren Chapman

Client: Two-34-236 S Huntington Av | Permit type: Plumbing permit | Expiration date: November 9, 2016 | Current use: Multi | Permit id: Pl588796 | Parcel: 1001784000
2016/05/091500100234236 S Huntington Boston MaDarren Chapman
SCORE
100
234236 S Huntington Boston Ma
Install a new 296 0 frunace & 000btu ruud water heater
Date:  May 9, 2016
Value:   $1,500
Contractor: Darren Chapman

Client: Two-34-236 S Huntington Av | Permit type: Gas permit | Expiration date: November 9, 2016 | Current use: Multi | Permit id: G588797 | Parcel: 1001784000
2016/05/091500100234236 S Huntington Boston MaDarren Chapman
SCORE
100
189199 Forest Hills Boston Ma
Replace three boilers 3-backflow preventers bldg. Three #189 191 and 193
Date:  September 6, 2016
Value:   $500
Contractor: Darren Chapman

Client: Forest Hills Housing Inc | Permit type: Plumbing permit | Expiration date: March 6, 2017 | Current use: Multi | Permit id: Pl633659 | Parcel: 1102926000
2016/09/06500100189199 Forest Hills Boston MaDarren Chapman
SCORE
100
189199 Forest Hills Boston Ma
Remove and dispose of 3 existing 4th floor boilers supply and install 3 new lochinvar khn series gas boilers for "building group 4 195 197 199 forest hills 195 forest hills = khn285 197 forest hills = khn285 199 forest hills = khn155
Date:  September 6, 2016
Value:   $500
Contractor: Darren Chapman

Client: Forest Hills Housing Inc | Permit type: Gas permit | Expiration date: March 6, 2017 | Current use: Multi | Permit id: G633641 | Parcel: 1102926000
2016/09/06500100189199 Forest Hills Boston MaDarren Chapman
SCORE
100
177181 Forest Hills Boston Ma
Remove and dispose of existing high efficiency gas boiler. Supply and install new lochinvar khn155 high efficiency gas boiler for building 177 remove and dispose of existing high efficiency gas boiler. Supply and install new lochinvar khn285 high efficiency gas boiler for buildings 179 & 181 3 boilers for 177-181 forest hill st "building 1"
Date:  September 6, 2016
Value:   $500
Contractor: Darren Chapman

Client: Forest Hills Housing Inc | Permit type: Gas permit | Expiration date: March 6, 2017 | Current use: Multi | Permit id: G633624 | Parcel: 1102926000
2016/09/06500100177181 Forest Hills Boston MaDarren Chapman
SCORE
100
183187 Forest Hills Boston Ma
Remove and dispose of 3 gas boilers; supply and install 3 new lochinvar boilers in "building 2" block 183 forest hills st = lochinvar khn285 185 forest hills st = lochinvar khn285 187 forest hills st = lochinvar khn199
Date:  September 6, 2016
Value:   $500
Contractor: Darren Chapman

Client: Forest Hills Housing Inc | Permit type: Gas permit | Expiration date: March 6, 2017 | Current use: Multi | Permit id: G633630 | Parcel: 1102926000
2016/09/06500100183187 Forest Hills Boston MaDarren Chapman
SCORE
100
183187 Forest Hills Boston Ma
Replace 3-boilers 3-backflow bldg. Two 183 185 and 187
Date:  September 6, 2016
Value:   $500
Contractor: Darren Chapman

Client: Forest Hills Housing Inc | Permit type: Plumbing permit | Expiration date: March 6, 2017 | Current use: Multi | Permit id: Pl633655 | Parcel: 1102926000
2016/09/06500100183187 Forest Hills Boston MaDarren Chapman
SCORE
100
1624 Union Park St Boston Ma
Install new lochinvar sit0 - gallon ss indirect water heater (along with new boiler and new boiler watts 911 backflow device
Date:  August 15, 2013
Value:   $4,000
Contractor: Darren Chapman

Permit type: Plumbing permit | Expiration date: February 15, 2014 | Current use: 1-4fam | Permit id: Pl262679 | Parcel: 0305961000
2013/08/1540001001624 Union Park St Boston MaDarren Chapman
SCORE
100
1624 Union Park St Boston Ma
Remove and dispose of existing weil mclain chimney vented atmospheric gas boiler. Install a new lochinvar kbn211 (2 btu input) high effeceincy gas boiler. Line chimney with approved fas n seal ss chimney liner (3") also install a lochinvar sit0 gallon ss indirect fired domestic hot water heater
Date:  August 15, 2013
Value:   $1,500
Contractor: Darren Chapman

Permit type: Gas permit | Expiration date: February 15, 2014 | Current use: 1-4fam | Permit id: G262657 | Parcel: 0305961000
2013/08/1515001001624 Union Park St Boston MaDarren Chapman
SCORE
100
6769 Brookley Rd Boston Ma
Gas permit for four lochinvar kbn081 (81 0 btus input each. Replace four old cast iron chimney vented small boilers and install new sidewall vented high effeceincy boilers and four lochivnar sit0 ( gallon) indirect water heaters (see also plumbing permit app # pl3436 fro water heater and boiler backflow device permit)
Date:  March 18, 2014
Value:   $20,000
Contractor: Darren Chapman

Client: Kilgore James R | Permit type: Gas permit | Expiration date: September 18, 2014 | Current use: 1-4fam | Permit id: G343618 | Parcel: 1102684000
2014/03/18200001006769 Brookley Rd Boston MaDarren Chapman
SCORE
100
8082 A St South Boston Ma
Address we have is 52 athens st #4 per richard chung (it person @ isd) use 80a st as athens ais on corner with a st.... Remove existing weather king furnace - install new 95% afue lennox gas furnace (45mbh input) - sidewall vented direct vent appliance
Date:  January 22, 2014
Value:   $5,500
Contractor: Darren Chapman

Client: Eighty A Street Condo Tr | Permit type: Gas permit | Expiration date: July 22, 2014 | Current use: Multi | Permit id: G319153 | Parcel: 0601197010
2014/01/2255001008082 A St South Boston MaDarren Chapman
SCORE
100
189199 Forest Hills Boston Ma
Remove and dispose of 3 existing 4th floor boilers supply and install 2 lochinvar khn199 boilers & 1 lochinvar khn285 189 forest hills st = khn199 191 forest hills st = khn285 193 forest hills st = khn199
Date:  September 6, 2016
Value:   $500
Contractor: Darren Chapman

Client: Forest Hills Housing Inc | Permit type: Gas permit | Expiration date: March 6, 2017 | Current use: Multi | Permit id: G633636 | Parcel: 1102926000
2016/09/06500100189199 Forest Hills Boston MaDarren Chapman
SCORE
100
18881892 Washington Boston Ma
Replace existing rooftop unit with new lennox kga092s4bm 7. 5 ton gas electric unit
Date:  June 16, 2016
Value:   $750
Contractor: Darren Chapman

Client: Bean Marilyn B | Permit type: Gas permit | Expiration date: December 16, 2016 | Current use: Comm | Permit id: G602002 | Parcel: 0801838000
2016/06/1675010018881892 Washington Boston MaDarren Chapman
SCORE
100
6769 Brookley Rd Boston Ma
Remove and dispose of four chimney vented domestic hot water heaters. Supply and install four - lochinvar sit0 - gallon indirect fired ss water heaters. Also see gas permit fro four lochihnvar boilers - kbn081 - 81 0 btus each (plumbing permit for four watts 911 backflow devices one for each boiler)
Date:  March 18, 2014
Value:   $10,000
Contractor: Darren Chapman

Client: Kilgore James R | Permit type: Plumbing permit | Expiration date: September 18, 2014 | Current use: 1-4fam | Permit id: Pl343610 | Parcel: 1102684000
2014/03/18100001006769 Brookley Rd Boston MaDarren Chapman
SCORE
100
2282 Beacon St Boston Ma
Please note that work is at 2 beacon st - computer did not allow #2 beacon used 232 replace old cast iron boiler with new lochinvar ftxl high efficiency boiler. Boiler is to be vented to roof via ss (fas n seal) approved flue piping system. Gas infrastructure (for old boiler) already in place... (combustion air from side wall of building pvc intake)
Date:  September 22, 2014
Value:   $15,000
Contractor: Darren Chapman

Client: Viola Frank L Trst | Permit type: Gas permit | Expiration date: March 22, 2015 | Current use: 1-4fam | Permit id: G408727 | Parcel: 0502624000
2014/09/22150001002282 Beacon St Boston MaDarren Chapman
SCORE
100
177181 Forest Hills Boston Ma
3 watts 911s (or equivalent) boiler feed backflow devices (one pre boiler) 3 lochinvar boilers to be installed at "building 1" (177 179 181 forest hills st - j. P.)
Date:  September 6, 2016
Value:   $500
Contractor: Darren Chapman

Client: Forest Hills Housing Inc | Permit type: Plumbing permit | Expiration date: March 6, 2017 | Current use: Multi | Permit id: Pl633644 | Parcel: 1102926000
2016/09/06500100177181 Forest Hills Boston MaDarren Chapman
SCORE
100
1315 Worcester Sq Boston Ma
Remove and dispose of two existing atmospheric gas boilers (burnham) supply and install two new lochivnar kbn286 boilers with two new sit0 indirect fired domestic hot water heaters... Include twin stainless steel chimney liners (one for each boiler) total gas input = 572 0 btus
Date:  August 16, 2013
Value:   $1,500
Contractor: Darren Chapman

Client: Thirteen-15 Worcester Sq | Permit type: Gas permit | Expiration date: February 16, 2014 | Current use: 1-4fam | Permit id: G275508 | Parcel: 0801510010
2013/08/1615001001315 Worcester Sq Boston MaDarren Chapman
SCORE
100
189199 Forest Hills Boston Ma
Replace 3-boilers 3- backflow preventers bldg. Four 195 197 and 199
Date:  September 6, 2016
Value:   $500
Contractor: Darren Chapman

Client: Forest Hills Housing Inc | Permit type: Plumbing permit | Expiration date: March 6, 2017 | Current use: Multi | Permit id: Pl633664 | Parcel: 1102926000
2016/09/06500100189199 Forest Hills Boston MaDarren Chapman
SCORE
100
844 Metropolitan Av Hyde Park Ma
Cross connections device for boiler also install indirect water heater
Date:  May 11, 2017
Value:   $1,000
Contractor: Darren Chapman

Client: Lee Perry T | Permit type: Plumbing permit | Expiration date: November 11, 2017 | Current use: 1-2fam | Permit id: Pl707753 | Parcel: 1811085000
2017/05/111000100844 Metropolitan Av Hyde Park MaDarren Chapman
SCORE
100
Date:  May 11, 2017
Value:   $500
Contractor: Darren Chapman

Client: Lee Perry T | Permit type: Gas permit | Expiration date: November 11, 2017 | Current use: 1-2fam | Permit id: G707752 | Parcel: 1811085000
2017/05/11500100844 Metropolitan Av Hyde Park MaDarren Chapman
SCORE
100
114 Commonwealth Av Boston Ma
Replace cross connection for boiler and install indirect water heater
Date:  May 11, 2017
Value:   $1,500
Contractor: Darren Chapman

Client: One 14 Commonwealth Condo Tr | Permit type: Plumbing permit | Expiration date: November 11, 2017 | Current use: Multi | Permit id: Pl707757 | Parcel: 0501357000
2017/05/111500100114 Commonwealth Av Boston MaDarren Chapman
SCORE
100
Date:  May 11, 2017
Value:   $500
Contractor: Darren Chapman

Client: One 14 Commonwealth Condo Tr | Permit type: Gas permit | Expiration date: November 11, 2017 | Current use: Multi | Permit id: G707755 | Parcel: 0501357000
2017/05/11500100114 Commonwealth Av Boston MaDarren Chapman
SCORE
100
362 Arborway Boston Ma
Remove existing water heater and replace with indirect fired hot water heater. Lochinvar sit080
Date:  June 13, 2017
Value:   $1,500
Contractor: Darren Chapman

Client: Fingerman David A | Permit type: Plumbing permit | Expiration date: December 13, 2017 | Current use: 1-2fam | Permit id: Pl719673 | Parcel: 1103379000
2017/06/131500100362 Arborway Boston MaDarren Chapman
SCORE
100
6668 School St Boston Ma
Replace furnace with a direct vented furnace
Date:  November 22, 2016
Value:   $500
Contractor: Darren Chapman

Client: Fripp James N | Permit type: Gas permit | Expiration date: May 22, 2017 | Current use: 1-2fam | Permit id: G659338 | Parcel: 1101472000
2016/11/225001006668 School St Boston MaDarren Chapman
SCORE
100
484 Beacon St Boston Ma
Replace failed heater unit with new htp "versa-hydro" dhw / space heating combination system
Date:  December 15, 2011
Value:   $500
Contractor: Darren Chapman

Client: Chapin Stewart | Permit type: Gas permit | Expiration date: June 15, 2012 | Current use: 1-4fam | Permit id: G109539 | Parcel: 0503688004
2011/12/15500100484 Beacon St Boston MaDarren Chapman
SCORE
100
6 Brigham St East Boston Ma
Repalce old atmospheric furnace with new lennox g61mpv-60c-091 side wall / direct vented condensing furnace
Date:  February 9, 2011
Value:   $5,000
Contractor: Darren Chapman

Client: Tremaine Russell F Ts | Permit type: Gas permit | Expiration date: August 9, 2011 | Current use: 1-3fam | Permit id: G63282 | Parcel: 0104600000
2011/02/0950001006 Brigham St East Boston MaDarren Chapman
SCORE
100
Bourne St Boston Ma
Install new (nat. Grid / freedom boiler # fcm120m - sidewall vented) boiler permit for gas piping and proper flue venting
Date:  April 1, 2010
Value:   $3,000
Contractor: Darren Chapman

Client: Knopf-Goldner Mark A | Permit type: Gas permit | Expiration date: October 1, 2010 | Current use: 1-2fam | Permit id: G19773 | Parcel: 1904531000
2010/04/013000100Bourne St Boston MaDarren Chapman
SCORE
100
27 Sunnyside St Boston Ma
Repalce old chimney vented furnace with new lennox slp98uh090v48c side wall vented 90% high effeceincy gas furnace. 90mbh input
Date:  October 18, 2011
Value:   $5,000
Contractor: Darren Chapman

Client: Burgess Jane A | Permit type: Gas permit | Expiration date: April 18, 2012 | Current use: 1-2fam | Permit id: G99872 | Parcel: 1001966000
2011/10/18500010027 Sunnyside St Boston MaDarren Chapman
SCORE
100
15 Zamora St Boston Ma
Replace old chimney vented furnace with new pvc / direct vented lennox furnace - model el195uh135xe60d ... 135mbh input
Date:  October 18, 2011
Value:   $4,000
Contractor: Darren Chapman

Client: Washington David R Ts | Permit type: Gas permit | Expiration date: April 18, 2012 | Current use: 1-2fam | Permit id: G98649 | Parcel: 1002192000
2011/10/18400010015 Zamora St Boston MaDarren Chapman
SCORE
100
484 Beacon St Boston Ma
Repalce existing heating unit with new htp - versa-hydro system. System is heating boiler and dhw production device 199 input /se gas permit # g109539
Date:  December 15, 2011
Value:   $1,500
Contractor: Darren Chapman

Client: Chapin Stewart | Permit type: Plumbing permit | Expiration date: June 15, 2012 | Current use: 1-4fam | Permit id: Pl109544 | Parcel: 0503688004
2011/12/151500100484 Beacon St Boston MaDarren Chapman
SCORE
100
39 W Cedar St Boston Ma
Permit to replace boiler feed / watts backflow device (911s) as we replace existing failed boiler with new lennox gwb-07e gas fired boiler
Date:  April 11, 2011
Value:   $500
Contractor: Darren Chapman

Client: Minton Therese S | Permit type: Plumbing permit | Expiration date: October 11, 2011 | Current use: 1-3fam | Permit id: Pl71031 | Parcel: 0501857000
2011/04/1150010039 W Cedar St Boston MaDarren Chapman
SCORE
100
232 Beacon St Boston Ma
Please note that work is at 2 beacon st - computer did not recognize #2 beacon as part of boiler replacement work install new backflow preventer and repalce glass lined / chimney vented water heater with new ss indirect fired domestic hot water heater
Date:  September 22, 2014
Value:   $5,000
Contractor: Darren Chapman

Client: Arostegui - Ham Viviana Ts | Permit type: Plumbing permit | Expiration date: March 22, 2015 | Current use: 1-4fam | Permit id: Pl408729 | Parcel: 0502625000
2014/09/225000100232 Beacon St Boston MaDarren Chapman
SCORE
100
15 Jacob St Dorchester Ma
Replace existing furnace with new lennox el296uh0415xv36 - 50mbh gas fired direct vented / sidewall vented furnace
Date:  December 6, 2012
Value:   $5,000
Contractor: Darren Chapman

Client: Daley Delcia I | Permit type: Gas permit | Expiration date: June 6, 2013 | Current use: 1-3fam | Permit id: G196773 | Parcel: 1403726000
2012/12/06500010015 Jacob St Dorchester MaDarren Chapman
SCORE
100
83 Elm St Boston Ma
Replace old furnace with new gas furnace
Date:  June 15, 2017
Value:   $500
Contractor: Darren Chapman

Client: Brooker Robert E Iii | Permit type: Gas permit | Expiration date: December 15, 2017 | Current use: 1-2fam | Permit id: G720725 | Parcel: 1901302010
2017/06/1550010083 Elm St Boston MaDarren Chapman
SCORE
100
939961 Tremont St Mission Hill Ma
Replace cross connection device
Date:  June 29, 2017
Value:   $500
Contractor: Darren Chapman

Client: Madison Davenport Inc | Permit type: Plumbing permit | Expiration date: December 29, 2017 | Current use: Multi | Permit id: Pl726010 | Parcel: 0901335050
2017/06/29500100939961 Tremont St Mission Hill MaDarren Chapman
SCORE
100
228 W Canton St Boston Ma
Replacing gas boiler
Date:  June 29, 2017
Value:   $500
Contractor: Darren Chapman

Client: Two 28 W Canton St Condo Tr | Permit type: Gas permit | Expiration date: December 29, 2017 | Current use: 1-3fam | Permit id: G725990 | Parcel: 0400694000
2017/06/29500100228 W Canton St Boston MaDarren Chapman
SCORE
100
3032 Hutchings St Dorchester Ma
Replacement of gas furnace
Date:  January 10, 2017
Value:   $500
Contractor: Darren Chapman

Client: Smith Daniel | Permit type: Gas permit | Expiration date: July 10, 2017 | Current use: 1-2fam | Permit id: G671388 | Parcel: 1202309000
2017/01/105001003032 Hutchings St Dorchester MaDarren Chapman
SCORE
100
211 W Second St South Boston Ma
Replacement of gas furnace
Date:  January 10, 2017
Value:   $500
Contractor: Darren Chapman

Client: Two 11 W Second St Condo Tr | Permit type: Gas permit | Expiration date: July 10, 2017 | Current use: 1-3fam | Permit id: G671393 | Parcel: 0601502000
2017/01/10500100211 W Second St South Boston MaDarren Chapman
SCORE
100
186 W Brookline St Boston Ma
Replace gas furnace
Date:  March 9, 2017
Value:   $500
Contractor: Darren Chapman

Client: Minturn Robert B Jr | Permit type: Gas permit | Expiration date: September 9, 2017 | Current use: 1-3fam | Permit id: G686458 | Parcel: 0400524000
2017/03/09500100186 W Brookline St Boston MaDarren Chapman
SCORE
100
228 W Canton St Boston Ma
Cross connection device
Date:  July 13, 2017
Value:   $500
Contractor: Darren Chapman

Client: Two 28 W Canton St Condo Tr | Permit type: Plumbing permit | Expiration date: January 13, 2018 | Current use: 1-3fam | Permit id: Pl725992 | Parcel: 0400694000
2017/07/13500100228 W Canton St Boston MaDarren Chapman
SCORE
100
Date:  July 13, 2017
Value:   $500
Contractor: Darren Chapman

Client: Madison Davenport Inc | Permit type: Gas permit | Expiration date: January 13, 2018 | Current use: Multi | Permit id: G726007 | Parcel: 0901335050
2017/07/13500100939961 Tremont St Mission Hill MaDarren Chapman
SCORE
100
44 White St East Boston Ma
Replace gas roof top unit
Date:  July 14, 2017
Value:   $500
Contractor: Darren Chapman

Client: Gray Allyson | Permit type: Gas permit | Expiration date: January 14, 2018 | Current use: 1-3fam | Permit id: G730345 | Parcel: 0103418000
2017/07/1450010044 White St East Boston MaDarren Chapman
SCORE
100
19 Commonwealth Av Brighton Ma
Replace gas furnace
Date:  January 26, 2017
Value:   $500
Contractor: Darren Chapman

Client: Parklake Realty Corp | Permit type: Gas permit | Expiration date: July 26, 2017 | Current use: Multi | Permit id: G675999 | Parcel: 2102469000
2017/01/2650010019 Commonwealth Av Brighton MaDarren Chapman
SCORE
100
9 Upton St Boston Ma
Replace gas furnace
Date:  July 19, 2017
Value:   $500
Contractor: Darren Chapman

Client: Nine Upton St Condo Trust | Permit type: Gas permit | Expiration date: January 19, 2018 | Current use: 1-3fam | Permit id: G729286 | Parcel: 0306954000
2017/07/195001009 Upton St Boston MaDarren Chapman
SCORE
100
Cedar Lane Wy Boston Ma
Replace gas furnace
Date:  July 19, 2017
Value:   $500
Contractor: Darren Chapman

Client: Gaud Susan M Trsts | Permit type: Gas permit | Expiration date: January 19, 2018 | Current use: 1-3fam | Permit id: G729303 | Parcel: 0501774000
2017/07/19500100Cedar Lane Wy Boston MaDarren Chapman
SCORE
100
34 Warren Av Boston Ma
Replace a failed rooftop gas / electric rooftop heat / cool unit. Install carrier 48hced08aa2a5-0a0a0.... 7. 5ton
Date:  September 6, 2011
Value:   $12,000
Contractor: Darren Chapman

Permit type: Gas permit | Expiration date: March 6, 2012 | Current use: Comm | Permit id: G91736
2011/09/061200010034 Warren Av Boston MaDarren Chapman
SCORE
100
Garden St Boston Ma
1)run new gas service from existing meter location at front of property down a long outdoor "corridor" to a new boiler room space at rear of building. Total developed length approx. 1 feet - using 1-1/4" sched steel 2)connect new gas line to a new lochivnar kbn211 condensing modulating high effeciency boiler 3)boiler is to be vented with polymer liner (manufacturer approved) inno-flue... Liner to be installed by billy sweet chimney sweeps
Date:  January 22, 2013
Value:   $3,500
Contractor: Darren Chapman

Client: Pci Management Llc | Permit type: Gas permit | Expiration date: July 22, 2013 | Current use: 1-4fam | Permit id: G200135 | Parcel: 0502152000
2013/01/223500100Garden St Boston MaDarren Chapman
SCORE
100
107 Greaton Rd Boston Ma
Remove and dispose of old cast iron gas converted chimney vented boiler. Supply and install a new lochinvar kbn151 (1 0 btu input) gas / high effeciency side wall vented boiler - with a new lochinvar sit0 - gallon ss indirect fired domestic hot water heater
Date:  August 15, 2013
Value:   $500
Contractor: Darren Chapman

Client: Herring Nancy | Permit type: Gas permit | Expiration date: February 15, 2014 | Current use: 1-2fam | Permit id: G262993 | Parcel: 2006123000
2013/08/15500100107 Greaton Rd Boston MaDarren Chapman
SCORE
100
16 Durham St Boston Ma
Water piping for a new superstor ssu indirect water heater and a watts boiler feed / backflow device...
Date:  October 10, 2013
Value:   $5,000
Contractor: Darren Chapman

Client: Forkner Peter C | Permit type: Plumbing permit | Expiration date: April 10, 2014 | Current use: 1-4fam | Permit id: Pl291719 | Parcel: 0400862000
2013/10/10500010016 Durham St Boston MaDarren Chapman
SCORE
100
Martin St Boston Ma
Add small 1/2 bathroom to first floor
Date:  August 20, 2015
Value:   $1,500
Contractor: Darren Chapman

Client: Ayoub Gretchen T | Permit type: Plumbing permit | Expiration date: February 20, 2016 | Current use: 1-2fam | Permit id: Pl508389 | Parcel: 2002005000
2015/08/201500100Martin St Boston MaDarren Chapman
SCORE
100
1 Salem St Boston Ma
Replace failed gas boiler with new twin / new lochivar kbn151 (151 0 btu input) high effeceincy boilers. New boilers to be properly vented via twin new 3" ss chimney liners (liners by billy sweet chimney sweeps)
Date:  January 13, 2014
Value:   $2,500
Contractor: Darren Chapman

Client: Yip Collin Chun Yin Ts | Permit type: Gas permit | Expiration date: July 13, 2014 | Current use: Mixed | Permit id: G318444 | Parcel: 0301335000
2014/01/1325001001 Salem St Boston MaDarren Chapman
SCORE
100
16 Durham St Boston Ma
Replace existing boiler with new burnham p205 cast boielr / chimney vented. Also see plumbing permit for watts boielr backflow device and new superstor ssu indirect water heater and realted potable piping...
Date:  October 7, 2013
Value:   $7,500
Contractor: Darren Chapman

Client: Forkner Peter C | Permit type: Gas permit | Expiration date: April 7, 2014 | Current use: 1-4fam | Permit id: G291714 | Parcel: 0400862000
2013/10/07750010016 Durham St Boston MaDarren Chapman
SCORE
100
4 Boylston Pl Boston Ma
Remove two oil fired boilers and oil storage tanks install one lochinvar kbn4 (399 0 btu input) hydronic boiler - side wall vanted to "private courtyard area" install one burnham k5006snei (401 0 btu input) steam boiler / chimney vented
Date:  July 17, 2012
Value:   $1,500
Contractor: Darren Chapman

Client: The Tavern Club | Permit type: Gas permit | Expiration date: January 17, 2013 | Current use: 7more | Permit id: G156619 | Parcel: 0500038000
2012/07/1715001004 Boylston Pl Boston MaDarren Chapman
SCORE
100
86 Moss Hill Rd Boston Ma
Remove and dispose of failed cast iron / chimney vented boiler. Supply and install a new lochivnar kbn151 (151 0 btu input) high effeciency side wall vented boiler. See alos plumbing permit for backflow device and lochivnar sit0 - gallon ss indirect fired domestic hot water heater
Date:  October 24, 2013
Value:   $1,500
Contractor: Darren Chapman

Client: Greene Mary Louise | Permit type: Gas permit | Expiration date: April 24, 2014 | Current use: 1-2fam | Permit id: G295319 | Parcel: 1902475000
2013/10/24150010086 Moss Hill Rd Boston MaDarren Chapman
SCORE
100
105 Radcliffe St Dorchester Ma
Replace oil fired furnace with new lennox el296uh110xv48c gas - direct / sidewall vented furnace
Date:  December 6, 2012
Value:   $5,000
Contractor: Darren Chapman

Client: Courtney Alfonzia | Permit type: Gas permit | Expiration date: June 6, 2013 | Current use: 1-3fam | Permit id: G196766 | Parcel: 1402361000
2012/12/065000100105 Radcliffe St Dorchester MaDarren Chapman
SCORE
100
4 Boylston Pl Boston Ma
Plumbing permit for backflow / boiler feed devices for two new boilers. One hydronic boiler = lochinvar kbn4 and one steam boiler = burnham k5006snei lochinvar to have watts backflow burnham to have backflow m/m water feeder / lwco
Date:  July 17, 2012
Value:   $1,500
Contractor: Darren Chapman

Client: The Tavern Club | Permit type: Plumbing permit | Expiration date: January 17, 2013 | Current use: Mixed | Permit id: Pl156608 | Parcel: 0500038000
2012/07/1715001004 Boylston Pl Boston MaDarren Chapman
SCORE
100
19 Charles River Sq Boston Ma
Replace failed gas furnace with new gas furnace... 80% / chimney vented lennox sl280uh110v60c gas furnace
Date:  January 20, 2015
Contractor: Darren Chapman

Client: Nessen Beatrice | Permit type: Gas permit | Expiration date: July 20, 2015 | Current use: Multi | Permit id: G441176 | Parcel: 0502453000
2015/01/20010019 Charles River Sq Boston MaDarren Chapman
SCORE
100
234 Beacon St Boston Ma
Convert oil burner to new gas burner (beckett 6 0 btu input burner)- includes new gas fitting from boiler room / burner to new meter location on dartmouth st side of building
Date:  October 7, 2013
Value:   $12,000
Contractor: Darren Chapman

Client: Two 34 Beacon St Condo Tr | Permit type: Gas permit | Expiration date: April 7, 2014 | Current use: Multi | Permit id: G291683 | Parcel: 0502626000
2013/10/0712000100234 Beacon St Boston MaDarren Chapman
SCORE
100
39 W Cedar St Boston Ma
Nipple fit (gas) to replace existing failed lennox boiler with new / same lennox boiler model number gwb-07e (37 500btu input)
Date:  April 11, 2011
Value:   $500
Contractor: Darren Chapman

Client: Minton Therese S | Permit type: Gas permit | Expiration date: October 11, 2011 | Current use: 1-3fam | Permit id: G71028 | Parcel: 0501857000
2011/04/1150010039 W Cedar St Boston MaDarren Chapman
SCORE
100
9 Concord Sq Boston Ma
Remove and dispose of failed burnham boiler (backflow preventer) and obsolete rheem water heater - install new lochinvar kbn211 boiler and lochinvar sit0 - indirect water heater (permit for watts backflo boielr feeder and water piping / indirect water heater)
Date:  August 16, 2013
Value:   $5,000
Contractor: Darren Chapman

Client: Nine Concord Sq Condo Tr | Permit type: Plumbing permit | Expiration date: February 16, 2014 | Current use: 1-4fam | Permit id: Pl274915 | Parcel: 0402665000
2013/08/1650001009 Concord Sq Boston MaDarren Chapman
SCORE
100
57 Burroughs St Boston Ma
Install new watts 911 backflow device for new boiler installation (see gas permit) also install new lochinvar sit040indirect fired domestic hot water heater
Date:  February 18, 2011
Value:   $500
Contractor: Darren Chapman

Client: Elliott William | Permit type: Plumbing permit | Expiration date: August 18, 2011 | Current use: 1-2fam | Permit id: Pl64645 | Parcel: 1901913004
2011/02/1850010057 Burroughs St Boston MaDarren Chapman
SCORE
100
Bourne St Boston Ma
Install boiler (watts) 911 valve & install an indirect fired (lochinvar sss051) water heater
Date:  April 1, 2010
Value:   $3,000
Contractor: Darren Chapman

Client: Knopf-Goldner M | Permit type: Plumbing permit | Expiration date: October 1, 2010 | Current use: 1unit | Permit id: Pl19769 | Parcel: 1904531000
2010/04/013000100Bourne St Boston MaDarren Chapman
SCORE
100
450c Walk Hill St Mattapan Ma
Replace failed boiler
Date:  April 1, 2010
Value:   $5,000
Contractor: Darren Chapman

Permit type: Gas permit | Expiration date: October 1, 2010 | Current use: Mixed | Permit id: G19530
2010/04/015000100450c Walk Hill St Mattapan MaDarren Chapman
SCORE
100
75 Revere St Boston Ma
Install new lochinvar sit51 stainless steel indirect fired domestic hot water heater
Date:  September 21, 2010
Value:   $2,500
Contractor: Darren Chapman

Client: Moran William K | Permit type: Plumbing permit | Expiration date: March 21, 2011 | Current use: 1-2fam | Permit id: Pl43410 | Parcel: 0502025000
2010/09/21250010075 Revere St Boston MaDarren Chapman
SCORE
100
8 Oriole St Boston Ma
Replace water heater.
Date:  February 11, 2010
Contractor: Darren Chapman

Client: Crowley Sean T | Permit type: Gas permit | Expiration date: August 11, 2010 | Current use: 1-7fam | Permit id: G14020 | Parcel: 2002148000
2010/02/1101008 Oriole St Boston MaDarren Chapman
SCORE
100
2 Wayburn Rd Boston Ma
Replace one fixture.
Date:  January 11, 2010
Value:   $1
Contractor: Darren Chapman

Client: Hoener Clayton | Permit type: Plumbing permit | Expiration date: July 11, 2010 | Current use: 1-7fam | Permit id: Pl10680 | Parcel: 1904571000
2010/01/1111002 Wayburn Rd Boston MaDarren Chapman
SCORE
100
13 15 Worcester Sq Boston Ma
As part of boiler replacemnt efforts... Replace two existing chimney vent 75 gallon water heaters and install twin lochinvar sit0 ss indirect fired water heaters and related water piping
Date:  August 16, 2013
Value:   $7,500
Contractor: Darren Chapman

Permit type: Plumbing permit | Expiration date: February 16, 2014 | Current use: 1-4fam | Permit id: Pl275579 | Parcel: 0801510010
2013/08/16750010013 15 Worcester Sq Boston MaDarren Chapman
SCORE
100
1 Salem St Boston Ma
Plumbing pemrit for twin new lochinvar boilers - backflow preventer and 119 gallon ss indirect water heater
Date:  January 14, 2014
Value:   $5,500
Contractor: Darren Chapman

Permit type: Plumbing permit | Expiration date: July 14, 2014 | Current use: Mixed | Permit id: Pl318447 | Parcel: 0301335000
2014/01/1455001001 Salem St Boston MaDarren Chapman
SCORE
100
24 Westglow St Dorchester Ma
Replace failed (chimney vented) water heater ruud gallon gas
Date:  April 1, 2010
Value:   $800
Contractor: Darren Chapman

Permit type: Plumbing permit | Expiration date: October 1, 2010 | Current use: 1-2fam | Permit id: Pl19533 | Parcel: 1602047000
2010/04/0180010024 Westglow St Dorchester MaDarren Chapman
SCORE
100
56 Pinckney St Boston Ma
Replace chimney vented water heater.
Date:  February 4, 2010
Contractor: Darren Chapman

Client: Bordewick James R Jr | Permit type: Plumbing permit | Expiration date: August 4, 2010 | Current use: 1-7fam | Permit id: Pl13595 | Parcel: 0501664000
2010/02/04010056 Pinckney St Boston MaDarren Chapman
SCORE
100
Mendum St Roslindale Ma
Pipe in a new gas fireplace
Date:  April 27, 2010
Value:   $1,000
Contractor: Darren Chapman

Client: Glidden Kenneth | Permit type: Gas permit | Expiration date: October 27, 2010 | Current use: 1-2fam | Permit id: G23291 | Parcel: 2005333000
2010/04/271000100Mendum St Roslindale MaDarren Chapman
SCORE
100
138 144 Lincoln St Boston Ma
Install new furnace - lennox ml180uh110p48c - chimney vented 80% unit for the fifth floor living space. Also install lennox ml180uh110p48c furnace for the sixth floor living space.
Date:  February 6, 2014
Value:   $15,000
Contractor: Darren Chapman

Client: Rosenberg Lewis | Permit type: Gas permit | Expiration date: August 6, 2014 | Current use: 1-4fam | Permit id: G315878 | Parcel: 0304329000
2014/02/0615000100138 144 Lincoln St Boston MaDarren Chapman
SCORE
100
8 Oriole St Boston Ma
Replace 1 fixture.
Date:  February 11, 2010
Contractor: Darren Chapman

Client: Crowley Sean T | Permit type: Plumbing permit | Expiration date: August 11, 2010 | Current use: 1-7fam | Permit id: Pl14018 | Parcel: 2002148000
2010/02/1101008 Oriole St Boston MaDarren Chapman
SCORE
100
11 Rhoda St Boston Ma
Repalce failed gas furnace new condensing 90% lennox g61mpv-36b-071 furnace ( 000btu input)
Date:  April 27, 2010
Value:   $4,500
Contractor: Darren Chapman

Client: Moran Jennifer | Permit type: Gas permit | Expiration date: October 27, 2010 | Current use: 1-2fam | Permit id: G22544 | Parcel: 2005703000
2010/04/27450010011 Rhoda St Boston MaDarren Chapman
SCORE
100
34 Myrtle St Boston Ma
Install hydronic heating and refrigeration cooling lines with an air handler to facilitate adding and autonomous dedicated heating cooiling system for penthouse unit # 5 @ 34 myrtle st. Boston
Date:  May 19, 2010
Value:   $15,000
Contractor: Darren Chapman

Client: West End Trust | Permit type: Short form bldg permit | Expiration date: November 19, 2010 | Current use: 5unit | Permit id: Sf26537 | Parcel: 0501880000
2010/05/191500010034 Myrtle St Boston MaDarren Chapman
SCORE
100
3 Stoughton Street P Dorchester Ma
Replace old chimney vented furnace with new sidewall (pvc) vented 0 btu lennox unit lennox slp98uh-070xv36b (97%afue)
Date:  May 31, 2016
Value:   $750
Contractor: Darren Chapman

Client: Boswell Zachary K | Permit type: Gas permit | Expiration date: November 30, 2016 | Current use: 1-2fam | Permit id: G597182 | Parcel: 1301366000
2016/05/317501003 Stoughton Street P Dorchester MaDarren Chapman
SCORE
100
1315 Worcester Sq Boston Ma
As part of boiler replacemnt efforts... Replace two existing chimney vent 75 gallon water heaters and install twin lochinvar sit0 ss indirect fired water heaters and related water piping
Date:  August 16, 2013
Value:   $7,500
Contractor: Darren Chapman

Client: Thirteen-15 Worcester Sq | Permit type: Plumbing permit | Expiration date: February 16, 2014 | Current use: 1-4fam | Permit id: Pl275579 | Parcel: 0801510010
2013/08/1675001001315 Worcester Sq Boston MaDarren Chapman
SCORE
100
138144 Lincoln St Boston Ma
Install new furnace - lennox ml180uh110p48c - chimney vented 80% unit for the fifth floor living space. Also install lennox ml180uh110p48c furnace for the sixth floor living space.
Date:  February 6, 2014
Value:   $15,000
Contractor: Darren Chapman

Client: Lrjr Llc | Permit type: Gas permit | Expiration date: August 6, 2014 | Current use: 1-4fam | Permit id: G315878 | Parcel: 0304329000
2014/02/0615000100138144 Lincoln St Boston MaDarren Chapman
SCORE
100
34 Myrtle St Boston Ma
Plumbing permit for hydronic boiler backflow device - boiler is to support a dedicated / autonomous hydro-air heating system for the "penthouse" unit #5 @ 34 myrtle st.
Date:  May 19, 2010
Value:   $500
Contractor: Darren Chapman

Client: West End Trust | Permit type: Plumbing permit | Expiration date: November 19, 2010 | Current use: 1unit | Permit id: Pl25564 | Parcel: 0501880000
2010/05/1950010034 Myrtle St Boston MaDarren Chapman
SCORE
100
1 Acorn St Boston Ma
Replace 30 year old furnace with new chimney vented lennox gas furnace model # sl280uh135v60d / ... 135 0 btu input
Date:  August 13, 2015
Value:   $7,500
Contractor: Darren Chapman

Client: Roosevelt Candace C | Permit type: Gas permit | Expiration date: February 13, 2016 | Current use: 1-2fam | Permit id: G504394 | Parcel: 0501530000
2015/08/1375001001 Acorn St Boston MaDarren Chapman
SCORE
100
57 Burroughs St Boston Ma
Replace existing atmospheric gas boiler with new high effeciency lochinvar kbn151 90% effecient boiler - side wall vented
Date:  February 18, 2011
Value:   $8,000
Contractor: Darren Chapman

Client: Monica Petri Trust | Permit type: Gas permit | Expiration date: August 18, 2011 | Current use: 1-2fam | Permit id: G64649 | Parcel: 1901913004
2011/02/18800010057 Burroughs St Boston MaDarren Chapman
SCORE
100
58 Child St Hyde Park Ma
Replace backflow on boiler and install indirect water heater
Date:  January 26, 2017
Value:   $1,000
Contractor: Darren Chapman

Client: Oreilly Kathleen M | Permit type: Plumbing permit | Expiration date: July 26, 2017 | Current use: 1-2fam | Permit id: Pl675989 | Parcel: 1811615000
2017/01/26100010058 Child St Hyde Park MaDarren Chapman
SCORE
100
58 Child St Hyde Park Ma
Replace gas boiler with khn-155
Date:  January 26, 2017
Value:   $500
Contractor: Darren Chapman

Client: Oreilly Kathleen M | Permit type: Gas permit | Expiration date: July 26, 2017 | Current use: 1-2fam | Permit id: G675991 | Parcel: 1811615000
2017/01/2650010058 Child St Hyde Park MaDarren Chapman
SCORE
100
75 Revere St Boston Ma
Install a new buderus gb142/45 - 94% effecient boiler. 167 0 rated input
Date:  September 21, 2010
Value:   $7,500
Contractor: Darren Chapman

Client: Moran William K | Permit type: Gas permit | Expiration date: March 21, 2011 | Current use: 1-2fam | Permit id: G43400 | Parcel: 0502025000
2010/09/21750010075 Revere St Boston MaDarren Chapman
SCORE
100
632 W Roxbury Pk Boston Ma
Replace exisitng boiler with new lochinvar kbn151 (151 000mbh input) side wall vented - condesning / modulating hydronic boiler
Date:  October 7, 2010
Value:   $9,000
Contractor: Darren Chapman

Permit type: Gas permit | Expiration date: April 7, 2011 | Current use: 1-2fam | Permit id: G45131
2010/10/079000100632 W Roxbury Pk Boston MaDarren Chapman
SCORE
100
34 Myrtle St Boston Ma
Gas piping needs to support a new / dedicated boiler for an autonomous hydro-air heating system dedicated for the "penthouse" unit # 5 @ 34 myrtle st.
Date:  May 19, 2010
Value:   $2,500
Contractor: Darren Chapman

Client: West End Trust | Permit type: Gas permit | Expiration date: November 19, 2010 | Current use: 1unit | Permit id: G25554 | Parcel: 0501880000
2010/05/19250010034 Myrtle St Boston MaDarren Chapman
BEST LOCAL CONTRACTORS




Contractor Rank Contractor Details Number of Projects Avg. Project Cost Years in Business Photos
Need a Contractor ?
Just fill out a form below and get several free quotes from best local contractors in your area.