Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
SCORE 93 2536 Page St Philadelphia Pa 191215207 Masonry front wall - remove existing 2 story front masonry wall. Replace with new 8 inch masonry wall, (4" brick & 4" block) on existing foundation. Windows and door same location & shall comply with the 2009 international energy efficiency code, u factor of . 35, and with emergency egress standards as per irc. New door opening for 36 inch door. Horizontal reinforcement (durawall) every 24 inches. Install returns into party walls for structural connection. Flash and seal roof to new front. Install 2 x 4 frame wall, r-19 insulation and sheetrock on interior front wall for finish. No other work allowed under this permit. Date: September 29, 2014 Contractor: Champs Angels Construction Client: Gadson Michael Harkness Charlane | Permit type: Alteration permit | Permit status: Completed | Completion date: July 9, 2015 | Permit id: 563214 | |||||
SCORE 93 645 N 39th St Philadelphia Pa 191041856 Make safe permit. Remove all deteriorated materials in the roof and wall areas. Retsore masony wall with masonry, replace roof rafters, 1 2 cdx sheathing and roof covering to resort roof to a weather tight condition. Remove and replace floor joist and 3 4 t&g plywood at 2nd floor rear. Maitain propoerty from trespass by sealing windows and doors or replace as needed. Separate permits required for interior alterations post this permit post the project informations sign Date: September 2, 2015 Contractor: Champs Angels Construction Client: Black George D | Permit type: Alteration permit | Permit status: Expired | Completion date: February 22, 2017 | Permit id: 636422 | |||||
SCORE 93 35 Spring Garden St Philadelphia Pa 191042408 Make safe as as per violation# 460516. Remove (2) small part of block facade to access tree growing through structure. Replace to make safe as per engineer report. Contact streets department for a footway closure. Call and complete an intial inspection prior to start of work. Date: January 30, 2015 Contractor: Champs Angels Construction Client: Gardiner Antoine | Permit type: Alteration permit | Permit status: Expired | Completion date: April 22, 2015 | Permit id: 587831 | |||||
SCORE 93 35 Spring Garden St Philadelphia Pa 191042408 Make safe permit - for repair of exterior walls roof as per engineers report prepared by alex y. Rong, p. E., to resolve case # 460516 . Abutting sidewalk must be closed with fencing a minimum of 6 in height. Separate streets department permit required for sidewalk closure. A separate permit is required for any additional alterations that are not specifically addressed on case 460516. Date: May 13, 2015 Contractor: Champs Angels Construction Client: Gardiner Antoine | Permit type: Alteration permit | Permit status: Expired | Completion date: January 31, 2017 | Permit id: 609214 | |||||
SCORE 93 2059 Mountain St Philadelphia Pa 191451427 For the complete demolition of a two-story structure- hand methods only, as per plan. A covered walkway or sidewalk closure shall be required within 6 feet of building facade in accordance with section 3306 of the ibc. Separate building and or streets department permits may be required. Any deviation will require an amended building permit. Date: November 6, 2017 Contractor: Champs Angels Construction Client: Tjokronolo Dunung G Khawaja Atif | Permit type: Demolition permit | Permit status: Active | Completion date: November 6, 2017 | Permit id: 820733 | |||||
SCORE 93 137 Kingsley St Philadelphia Pa 19127 Ez permit ductwork & warm-air appliances- for the installation of new ductwork, high efficiency ac appliances as per attached standard. Deviations from this standard will result in permit revocation and require submission of construction plans. Date: September 23, 2015 Contractor: Champs Angels Construction Permit type: Mechanical permit | Permit status: Completed | Completion date: January 2, 2016 | Permit id: 640976 | |||||
SCORE 93 252 N Peach St Philadelphia Pa 191391409 Make safe permit - for replace fractured rear wall (no engineer? S report) to resolve case #428079. Abutting sidewalk must be closed with fencing a minimum of 6? In height. Separate streets department permit required for sidewalk closure. A separate permit is required for any additional alterations that are not specifically addressed on case #428079. Date: September 15, 2015 Contractor: Champs Angels Construction Client: Whitaker Vanessa | Permit type: Alteration permit | Permit status: Expired | Completion date: September 30, 2016 | Permit id: 638529 | |||||
SCORE 93 135 Kingsley St Philadelphia Pa 191271708 Installation of a 100,0 btu direct vent 90+ goodman gas furnace and 3 ton a c. Including all ducts registers and refrigerant piping. Date: December 24, 2014 Contractor: Champs Angels Construction Client: Caracausa Desantis Acquisitions Lp | Permit type: Mechanical permit | Permit status: Expired | Completion date: March 24, 2017 | Permit id: 581685 | |||||
SCORE 93 2112 Latona St Philadelphia Pa 191464311 For the erection of an addition on the third floor level with a roof deck over the third story portion accessed by a roof deck access structure on an existing two story attached structure. Structure for use as a single family dwelling. All work to be done per approved plans. If field conditions vary contact design engineer prior to the start of any work. Separate permits required for mechanical, electrical, and plumbing work. Date: August 18, 2017 Contractor: Champs Angels Construction Client: Kauffman David Kauffman Pamela L | Permit type: Addition permit | Permit status: Active | Completion date: October 31, 2017 | Permit id: 794256 | |||||
SCORE 93 141 Kingsley St Philadelphia Pa 19127 Ez permit ductwork & warm-air appliances- for the installation of new ductwork, high efficiency ac appliances as per attached standard. Deviations from this standard will result in permit revocation and require submission of construction plans. Date: September 23, 2015 Contractor: Champs Angels Construction Permit type: Mechanical permit | Permit status: Completed | Completion date: January 2, 2016 | Permit id: 640981 | |||||
SCORE 93 1517 North St Philadelphia Pa 191303405 5 square feet of interior alterations - single family dwelling - applicant agrees to limit the construction to comply with ez permit standard for interior alterations, dated feb. 2007. Deviations from this standard will result in the revocation of this permit and imposition of further penalties. Licensed contractor to be listed on permit separate permits required for plumbing, electric and hvac. Call inspector at district office at least 24 hours prior to starting work. Date: August 1, 2013 Contractor: Champs Angels Construction Client: Bahgat Tarek Ahmed Bahgat Amy M | Permit type: Alteration permit | Permit status: Completed | Completion date: August 4, 2014 | Permit id: 486703 | |||||
SCORE 93 139 Kingsley St Philadelphia Pa 19127 Ez permit ductwork & warm-air appliances- for the installation of new ductwork, high efficiency ac appliances as per attached standard. Deviations from this standard will result in permit revocation and require submission of construction plans. Date: September 23, 2015 Contractor: Champs Angels Construction Permit type: Mechanical permit | Permit status: Completed | Completion date: January 2, 2016 | Permit id: 640980 | |||||
SCORE 93 3443 N Carlisle St Philadelphia Pa 191405108 Replacement of deteriorated portions of front porch and rear shed. No complete removal. No change in size or location Date: August 29, 2017 Contractor: Champs Angels Construction Client: Walnut 191 Holdings Llc | Permit type: Alteration permit | Permit status: Completed | Completion date: September 20, 2017 | Permit id: 812423 | |||||
SCORE 93 8136 Ardleigh St Philadelphia Pa 191183412 Ez permit ductwork & warm-air appliances- for the installation of new ductwork, registers grilles diffusers, and warm-air appliances as per attached standard. Deviations from this standard will result in permit revocation and require submission of construction plans. Date: March 7, 2016 Contractor: Champs Angels Construction Client: Poblenz Ann Theres | Permit type: Mechanical permit | Permit status: Expired | Completion date: November 13, 2016 | Permit id: 674633 |