SCORE 92 Date: April 14, 2014 Contractor: Beyonergy Electric Permit type: Electrical permit | Permit status: Complete | Permit id: Ew20140407921 | |||||
SCORE 92 2972 21st St San Francisco Ca Rewire entire unit (2 bathrooms 3 bedrooms kitchen living room hallway dining room laundry room and furnace). Approximately 15 circuits 48 lights 26 switches. Replace subpanel at existing location. Date: December 19, 2012 Contractor: Beyonergy Electric Permit type: Electrical permit | Permit status: Issued | Permit id: Ew20121219101 | |||||
SCORE 92 45 Joost Av San Francisco Ca Top floor: for all tasks below will use the existing bedrooms outlet circuits to feed the lights and switch: ? Replace knob and tube wiring with romex in front bedroom: one switch and one light. ? Replace knob and tube wiring with romex in hallway: two lights and two switches. ? Replace knob and tube wiring with romex in bathroom: one switch and one light. ? Replace knob and tube wiring with romex in rear bedroom: one light and one switch. ? Add one light and one switch in attic using one of the existing dedicated circuits in the rear bedroom for furnace. Add one light and one switch in attic. Date: December 27, 2011 Contractor: Beyonergy Electric Permit type: Electrical permit | Permit status: Issued | Permit id: Ew20111227561 | |||||
SCORE 92 926 Central Av San Francisco Ca Bathroom remodel #1: one fan three recessed lights one sconce one outlet one 20amp circuit one 15amp lighting circuit one 20amp circuit for radiant heat floors four switches. Bathroom remodel #2: one fan three recessed lights one sconce one outlet one 20amp circuit one 15amp lighting circuit one 20amp circuit for radiant heat floors one three way switch four switches. Install one new amp subpanel in bedroom. Date: April 29, 2012 Contractor: Beyonergy Electric Permit type: Electrical permit | Permit status: Issued | Permit id: Ew20120429642 | |||||
SCORE 92 926 Central Av San Francisco Ca ? Reconnect wires for lights in house. ? Add (2) motion sensor lights in back of house. Dining room: ? Run (1) 20amp dedicated circuit for heating pad. ? Run (1) 20amp circuit feeding kitchen countertop. ? Run (1) 20amp circuit feeding (5) to (6) outlets. ? Run (1) 15amp lighting circuit feeding (6) recessed lights (1) track light (1) ceiling fan and (1) ceiling light. ? Add (5) switches. Date: August 16, 2012 Contractor: Beyonergy Electric Permit type: Electrical permit | Permit status: Issued | Permit id: Ew20120816881 | |||||
SCORE 92 1963 15th St San Francisco Ca Laundry room: ? Add one (1) 50amp subpanel. ? Run one (1) 20amp dedicated circuit for washer and dryer. ? Add one (1) light and one (1) switch. Bathroom: ? Run one (1) 20amp circuit feeding one (1) gfci outlet one (1) switch one (1) light and one (1) exhaust fan. Kitchen: ? Run two (2) 20amp small appliance circuits outlet layout according to code. ? Run one (1) 20amp dedicated circuit for garbage disposal. ? Run one (1) 20amp dedicated circuit for dishwasher. ? Rewire one (1) light and one (2) switch. ? Add one (1) light and one (1) switch for pantry. Hallway: ? Add one (1) outlet and one (1) carbon monoxide smoke detector (hard wire with battery backup). Living room: ? Run one (1) 20amp circuit feeding 5-6 outlets. ? Rewire one (1) light and one (1) switch. Bedrooms: ? Run one (1) 20amp circuit feeding 5-6 outlets. ? Add one (1) carbon monoxide smoke detector (hard wire with battery backup). ? Rewire one (1) light and one (1) switch. Date: April 22, 2011 Contractor: Beyonergy Electric Permit type: Electrical permit | Permit status: Issued | Permit id: Ew20110422141 | |||||
SCORE 92 45 Joost Av San Francisco Ca To renew expired permit ew20111227561 (same scope of work) done by same contractor for final insp. Date: July 2, 2013 Contractor: Beyonergy Electric Permit type: Electrical permit | Permit status: Complete | Permit id: E201306251739 | |||||
SCORE 92 4466 24th St San Francisco Ca Install one light at rear of house with switch control in rear bedroom. Run one to two 20amp circuits and install 2-3 lights 1-2 switches and 4-5 outlets on deck. Date: March 25, 2011 Contractor: Beyonergy Electric Permit type: Electrical permit | Permit status: Issued | Permit id: Ew20110325701 | |||||
SCORE 92 29 21st St San Francisco Ca Upgrade 50amp subpanel at existing location. Rewire entire unit. New wiring for 3 bedrooms 1 office 1 full bathroom 1 half bathroom dining room living room kitchen and furnace room. Date: March 1, 2014 Contractor: Beyonergy Electric Permit type: Electrical permit | Permit status: Issued | Permit id: Ew20140301101 | |||||
SCORE 92 42 Pearl St San Francisco Ca Run one 20amp circuit feeding one outlet two sconces and one switch in bathroom. Install two wall lights at the front of the house with new wiring. Date: May 19, 2011 Contractor: Beyonergy Electric Permit type: Electrical permit | Permit status: Issued | Permit id: Ew20110519521 | |||||
SCORE 92 917 Fulton St San Francisco Ca Run one 20amp circuit feeding 1 outlet 1 switch and 3 sconces in bathroom. Replace light fixtures in closet and storage room according to condo conversion report. Date: May 6, 2011 Contractor: Beyonergy Electric Permit type: Electrical permit | Permit status: Issued | Permit id: Ew20110506421 | |||||
SCORE 92 1747 Waller St San Francisco Ca Bathroom: run one 20amp circuit feeding one outlet one fan one sconce two lights and three switches. Date: May 14, 2012 Contractor: Beyonergy Electric Permit type: Electrical permit | Permit status: Issued | Permit id: Ew20120514561 | |||||
SCORE 92 501 Darien Wy San Francisco Ca Subpanel upgrade: relocate outside closet. Bathroom remodel: run circuit(s) feeding (1) exhaust fan (4) lights (1) outlet and (4) switches. Date: May 29, 2012 Contractor: Beyonergy Electric Permit type: Electrical permit | Permit status: Issued | Permit id: Ew20120529521 | |||||
SCORE 92 192 Caine Av San Francisco Ca ? Service panel upgrade to 125amps ? Run one circuit feeding fireplace including installing switch. ? Run one 20amp circuit for garbage disposal and add one switch. Date: November 10, 2011 Contractor: Beyonergy Electric Permit type: Electrical permit | Permit status: Complete | Permit id: Ew20111101743 | |||||
SCORE 92 4631 18th St San Francisco Ca Unit 4631: ? Run one 20amp circuit feeding three outlets in living and three outlets in front bedroom. ? Run one 20amp circuit feeding three outlets in back bedroom. ? Run one 20amp circuit feeding two gfci in bathroom. ? Add one outlet behind stove. Relocate one switch in kitchen for ceiling light. Date: October 6, 2011 Contractor: Beyonergy Electric Permit type: Electrical permit | Permit status: Complete | Permit id: Ew20110926463 | |||||
SCORE 92 Unit 0 / 361 25th Av San Francisco Ca Add (1) 80amp subpanel. Rewire entire unit: 2 bedrooms 2 bathrooms living room dining room kitchen laundry area. 36 lights 18 switches 42 receptacles 3 smoke detectors 2 exhaust fans. Date: May 1, 2016 Contractor: Beyonergy Electric Permit type: Electrical permit | Permit status: Issued | Permit id: Ew201605017832 | |||||
SCORE 92 45 Joost Av San Francisco Ca Rewiring for ground floor: 2 bedrooms 1 play room 1 bathroom entry area 2 closets hallway and back porch. Add 2 outlets in garage. Total of 22 outlets 15 switches 22 lights 1 fan 3 smoke detectors. Contractor: Beyonergy Electric Permit type: Electrical permit | Permit status: Issued | Permit id: Ew20150910261 | |||||
SCORE 92 45 Joost Av San Francisco Ca Run 20amp circuits for washer and dryer in garage. Rewire 2 lights and 1 switch in lower room. Second floor/main: new wiring with lights and outlets for entrance library area hallway hallway closet front porch dining room sun run room and pantry area. Rewire kitchen with circuits. Third floor: new wiring for bathrooms; new wiring for hallway lights and outlets; add 2 lights and outlets for master bedrooms. Install smoke detectors. Date: December 26, 2013 Contractor: Beyonergy Electric Permit type: Electrical permit | Permit status: Issued | Permit id: Ew20131226901 | |||||
SCORE 92 Unit 0 / 361 25th Av San Francisco Ca New wiring for 14 recessed lights 3 switches 5 outlets in garage/ground floor. Date: June 5, 2016 Contractor: Beyonergy Electric Permit type: Electrical permit | Permit status: Issued | Permit id: Ew201606058540 | |||||
SCORE 92 919 Fulton St San Francisco Ca Code corrections for unit 919 and common area per condo conversion report: ? Replace the missing laundry box cover/s in the ceiling. ? Seal the unused opening/s in the laundry junction boxes and old main panel ? Replace the unapproved exposed splice wiring in the mid basement with an electrical installation suitable for the conditions of use ? Install a bonding conductor between the interior gas piping system and the grounding electrode conductor. Unit 919: ? Run one 20amp circuit feeding bathroom outlet three wall sconce lights and one switch. ? Remove exhaust fan. Kitchen: ? Run two (2) small appliance circuits for kitchen countertop outlet layout according to code. ? Run two (2) dedicated circuits for garbage disposal and dishwasher. Bedrooms: ? Replace the open-lamp type luminarie/s (light fixture) in the bedroom closet/s with an enclosed-lamp type. ? Replace the missing switch trim box cover/s in the closet. Backyard: ? Light outlet and hot tub outlet. Date: May 1, 2011 Contractor: Beyonergy Electric Permit type: Electrical permit | Permit status: Issued | Permit id: Ew20110501641 | |||||
SCORE 92 42 Pearl St San Francisco Ca Kitchen: ? Run two (2) 20amp small appliance circuits feeding countertops. ? Run one (1) 20amp dedicated circuit for garbage disposal. ? Run one (1) 20amp dedicated circuit for dishwasher. ? Run one (1) 20amp dedicated circuit for refrigerator. ? Run one (1) 20amp dedicated circuit for microwave. ? Run one (1) 15amp dedicated circuit for hood. ? Install one receptacle outlet for stove igniter. Ground floor/garage: ? Run one 20amp circuit feeding three light fixtures two three-way switches one one outlet for garage door opener. Date: May 16, 2011 Contractor: Beyonergy Electric Permit type: Electrical permit | Permit status: Issued | Permit id: Ew20110516602 | |||||
SCORE 92 1134 Church St San Francisco Ca (1) 50amp subpanel. Kitchen: (2) 20amp small appliance circuits; (2) 20amp circuits for dishwasher and garbage disposal; (1) 20amp dedicated circuit for refrigerator; (1) dedicated circuit for hood; (2) lights and (1) switch. Upper bathroom: (1) 20amp circuit for gfci outlet; new wiring for exhaust fan/light combo and (1) existing light and (3) switches; (1) 15amp for light circuit. Date: November 10, 2014 Contractor: Beyonergy Electric Permit type: Electrical permit | Permit status: Complete | Permit id: Ew20141002181 | |||||
SCORE 92 363 25th Av San Francisco Ca Add (1) 80amp subpanel. Rewire entire unit: 2 bedroom 2 bathrooms living room dining room kitchen laundry area. 38 lights switches 44 receptacles 3 smoke detectors 2 exhaust fans. Date: October 21, 2016 Contractor: Beyonergy Electric Permit type: Electrical permit | Permit status: Issued | Permit id: Ew201610211344 | |||||
SCORE 92 447 Vermont St San Francisco Ca Bathroom remodel: ? Run one (1) 20amp dedicated circuit for radiant heating. ? Run one (1) 20amp dedicated circuit for towel rack. ? Run one (1) 20amp circuit feeding two gfci outlets. ? Run one (1) 15amp circuit feeding center ceiling decorative light fixture one ceiling vent/exhaust van two sconces on the side of the mirror two 4? Recessed/pot lights over the bath and four switches. ? Run two (2) 60amp two-pole circuits feeding the tankless water heater. ? Add one (1) 100amp subpanel on ground floor. Date: September 1, 2011 Contractor: Beyonergy Electric Permit type: Electrical permit | Permit status: Issued | Permit id: Ew20110901541 |