Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Renovating cabret hall amll existing space ground level adding (2) av units and resetting existing devices no new walls cosmetic updates only doc20110715 Date: July 15, 2011 Permit status: Na | Permit id: Bfdf84329 | Parcel: 2102473001 | |||||
Cutting &; welding;to fit pipe to existing condenser water supply &; return piping (dpl 5-31-2015) for each separate location bfd paid detail required Date: February 5, 2015 Permit status: Na | Permit id: Cbw444690 | |||||
Welding only of racks from the pot washing machine bfd paid detail required Date: January 13, 2015 Permit status: Na | Permit id: Cbw439801 | |||||
Renovation work to include demolition and installation of new finishes drywall ceilings and carpet Date: June 8, 2011 Permit status: Na | Permit id: Fdc79886 | |||||
Welding only to repair garbage;disposal bowl bfd paid detail required Date: September 21, 2011 Permit status: Na | Permit id: Cbw95626 | |||||
Welding only of hot well that is leaking onto burn-out bfd paid detail required Date: October 25, 2013 Permit status: Na | Permit id: Cbw295935 | |||||
Welding pipes for hot water pump relocations bfd paid detail required Date: July 12, 2012 Permit status: Na | Permit id: Cbw161479 | |||||
SCORE 99 Temporary bagging of smoke detectors for dust control during construction Date: June 9, 2011 Contractor: John Moriarty Permit status: Na | Permit id: Bsd79616 | |||||
Welding only for installation of new ductwork &; fan to existing kitchen;exhaust hood (dpl) bfd paid detail required Date: August 1, 2011 Permit status: Na | Permit id: Cbw88322 | |||||
Burning/cutting/welding for installation of new stuctural support steel dpl5/15 bfd paid detail required Date: February 25, 2015 Permit status: Na | Permit id: Cbw448846 | |||||
Cutting/welding of feet of 6 inch pipe that provides heat &; hot water in winter &; chilled water in summer bfd paid detail required Date: May 11, 2015 Permit status: Na | Permit id: Cbw468703 | |||||
SCORE 82 Electrical fire alarms Client: Boston College Trs Of | Permit type: Fire alarm | Permit status: Expired | Current use: Comm | Permit id: Efa83503 | Parcel: 2102473001 | |||||
SCORE 99 Addies loft cafĂ remodel Permit type: Electrical | Permit status: Expired | Current use: Comm | Permit id: E373773 | |||||
SCORE 80 Remove and replace an existing cooling tower unit on roof of corcoran commons. Disconnect exiting cws&r piping make-up water drains and valves to unit at roof level. Replace & connect new piping and appurtenances at roof level. Disconnect power & control wiring to unit. Install new feeders from the existing mcca through the existing vfd to the new cooling tower fans. Rework existing steel dunnage to new load points and vibration isolators. Permit type: Renovations - exterior | Permit status: Expired | Current use: Comm | Permit id: Sf444249 | |||||
SCORE 89 General renovation of existing addies loft eatery in corcoran hall boston college. Scope of work consists of new finishes including gypsum drywall 1/2 walls acoustical ceiling tiles floor tiles and paint/interior coatings. Also included is the installation of a new rolling grille minor electrical work with replacement lighting and new millwork base cabinet fixtures. Permit type: Renovations -interior nsc | Permit status: Expired | Current use: Other | Permit id: Sf369770 | |||||
SCORE 99 Disconnect existing line and low voltage for existing dry cooler and reconnect line and low voltage for new dry cooler unit Permit type: Electrical | Permit status: Open | Current use: Other | Permit id: E544002 | |||||
SCORE 100 Remove existing epdm membrane existing insulation to remain. Install 1. 5" insulation over existing insulation and install new adhered epdm roof system. Permit type: Roofing | Permit status: Expired | Current use: Mixed | Permit id: Sf474538 | |||||
SCORE 100 Low voltage - corcoran commons security system Permit type: Electrical | Permit status: Expired | Current use: Comm | Permit id: Elv465468 | |||||
SCORE 96 Disconnect power going to rooftop unit. Re-connect power to new rooftop unit via new 60a disconnect. Permit type: Electrical | Permit status: Expired | Current use: Comm | Permit id: E446574 | |||||
SCORE 84 Wire two variable frequency drives on existing a/c pump motors. Permit type: Electrical | Permit status: Expired | Current use: Comm | Permit id: E62295 | |||||
SCORE 100 Remove existing epdm membrane existing insulation to remain. Install 1. 5" insulation over existing insulation and install new adhered epdm roof system. Client: Boston College Trs Of | Permit type: Roofing | Permit status: Expired | Current use: Mixed | Permit id: Sf474598 | Parcel: 2102473001 | |||||
SCORE 100 Replace existing conduits wiring in garage due to currosin Client: Boston College Trs Of | Permit type: Electrical | Permit status: Expired | Current use: Comm | Permit id: E373926 | Parcel: 2102473001 | |||||
SCORE 100 Furnish and install water piping and indirect drain for existing sink and glass filler Permit type: Plumbing | Permit status: Expired | Current use: Other | Permit id: Pl373476 | |||||
SCORE 100 Replace ceiling light fixture in each room qty 150 Permit type: Electrical | Permit status: Expired | Current use: Other | Permit id: E271440 | |||||
SCORE 97 Corcoran commons install and wire low voltage control panel with (1) amp 1 volt circuit and (6)low voltage devices. Permit type: Electrical | Permit status: Expired | Current use: Comm | Permit id: E18895 | |||||
SCORE 82 Renovation cabinet hall vancher slice building ground level Client: Boston College Trs Of | Permit type: Electrical | Permit status: Expired | Current use: Comm | Permit id: E83104 | Parcel: 2102473001 | |||||
SCORE 100 Replace existing parking garage light fixtures with led fixtures. Fixtures provided by others. Client: Boston College Trs Of | Permit type: Electrical | Permit status: Expired | Current use: Comm | Permit id: E383933 | Parcel: 2102473001 | |||||
SCORE 100 Minor interior finishes and upgrades to vanderslice-caberet room boston college. All work will be in compliance with 7 cmr 527 cmr 521 cmr no changes to egree or life safety systems. Client: Boston College Trs Of | Permit type: Renovations -interior nsc | Permit status: Expired | Current use: 1-7fam | Permit id: Sf75892 | Parcel: 2102473001 | |||||
SCORE 100 In existing dormitory #857/1992; replace (179) surface incandescent light fixtures. Client: Boston College Trs Of | Permit type: Electrical | Permit status: Expired | Current use: Comm | Permit id: E272435 | Parcel: 2102473001 |