Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Electrical permit Date: January 14, 2011 Client: Vestrymen Christ Church Rector Church Wardens | Permit status: Completed | Permit id: 320834 | |||||
Electrical permit Date: January 5, 2010 Client: Vestrymen Christ Church Rector Church Wardens | Permit status: Completed | Permit id: 246798 | |||||
Alteration permit Date: August 31, 2015 Client: Vestrymen Christ Church Rector Church Wardens | Permit status: Completed | Permit id: 626740 | |||||
Administrative permit Date: June 14, 2010 Client: Vestrymen Christ Church Rector Church Wardens | Permit status: Completed | Permit id: 280671 | |||||
Alteration permit Date: August 31, 2015 Client: Vestrymen Christ Church Rector Church Wardens | Permit status: Completed | Permit id: 626740 | |||||
Administrative permit Date: June 14, 2010 Client: Vestrymen Christ Church Rector Church Wardens | Permit status: Completed | Permit id: 280671 | |||||
Electrical permit Date: January 14, 2011 Client: Vestrymen Christ Church Rector Church Wardens | Permit status: Completed | Permit id: 320834 | |||||
Electrical permit Date: January 5, 2010 Client: Vestrymen Christ Church Rector Church Wardens | Permit status: Completed | Permit id: 246798 | |||||
Extend existing low partition wall to ceiling with new interior glazing, and light refinishing in existing great hall mezzanine area Date: August 31, 2015 Client: Estrymen Christ Church Rector Church Wardens | Permit type: Alteration permit | Permit status: Completed | Completion date: January 21, 2016 | Permit id: 626740 | |||||
SCORE 81 Install (2) 2 amp, 3 phase 120 208 volts, 4 wire panels for future theater needs. 16 amp service existing, work to comply with 2008 nec, artical 230. 42 (cc dist) Date: January 14, 2011 Contractor: Edward Dixon Client: Estrymen Christ Church Rector Church Wardens | Permit type: Electrical permit | Permit status: Completed | Completion date: April 27, 2011 | Permit id: 320834 | |||||
SCORE 96 Modify existing fire alarm system as per nfpa-72 (cc dist) Date: January 5, 2010 Contractor: James Carrigan Inc Client: Estrymen Christ Church Rector Church Wardens | Permit type: Electrical permit | Permit status: Completed | Completion date: January 3, 2011 | Permit id: 246798 | |||||
SCORE 100 Ez permit sprinkler relocation (nfpa 13)- for the relocation of sprinkler heads as per attached standard. Deviations from this standard will result in permit revocation and require submission of construction plans. Date: June 14, 2017 Contractor: Oliver Sprinkler Co Inc Client: Estrymen Christ Church Rector Church Wardens | Permit type: Suppression permit | Permit status: Active | Completion date: June 15, 2017 | Permit id: 789302 | |||||
Requested lawful occupancy sings as part of prior renovations under ap219078 & 222721 Date: June 14, 2010 Client: Estrymen Christ Church Rector Church Wardens | Permit type: Administrative permit | Permit status: Completed | Completion date: June 21, 2010 | Permit id: 280671 | |||||
SCORE 100 For interior alterations to existing space to include structural work to create space for new organ, as per approved plans. Exterior work limited to restoration of two windows in tower, per plan. No change in occupancy classification Date: April 10, 2017 Contractor: Wolfe Scott Associates Inc Client: Estrymen Christ Church Rector Church Wardens | Permit type: Alteration permit | Permit status: Active | Completion date: October 23, 2017 | Permit id: 761556 | |||||
SCORE 100 Installation of 1 new split system a c unit 3 registers duct work to new pipe as per plan. Date: April 17, 2017 Contractor: Elliott Lewis Corporation Client: Estrymen Christ Church Rector Church Wardens | Permit type: Mechanical permit | Permit status: Active | Completion date: June 15, 2017 | Permit id: 765999 |