Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
SCORE 88 Vacuum excavate 2 test holes on various utilities for ddots south capitol street project Date: July 31, 2013 Contractor: Dace Edwards Permit type: Excavation; boring test pit (each addl) | Permit status: Cancel/withdrawn | Expiration date: September 11, 2014 | |||||
SCORE 88 Excavation; boring test pit (each addl) Contractor: Dace Edwards Permit status: 3 | Expiration date: September 11, 2014 | Permit id: 0 | |||||
SCORE 88 Vacuum excavate 2 test holes on various utilities for ddots south capitol street project Contractor: Dace Edwards Permit status: Cancel/withdrawn | Expiration date: September 11, 2014 | Permit id: 0 | |||||
SCORE 88 Excavation; boring test pit (each addl) Contractor: Dace Edwards Permit status: 3 | Expiration date: September 11, 2014 | Permit id: 0 | |||||
SCORE 88 Vacuum excavate 2 test holes on various utilities for ddots south capitol street project Contractor: Dace Edwards Permit status: Cancel/withdrawn | Expiration date: September 11, 2014 | Permit id: 0 | |||||
SCORE 89 Manhole access 11 days Date: January 16, 2015 Contractor: Impregilohealyparsons Jv Permit status: Permit expired | Expiration date: February 1, 2015 | Permit id: Pa10173301 | |||||
1st- extension of permit number pa59663:(59663r1=64967); refer to approved traffic control plan (tcp) for permitted hours of work; tcp expiration date same as public space permit expiration date; one (1) geotechnical boring identified as arc-21 that is approximately 8 inches in diameter and approximately 1 feet deep. A monitoring well or vibrating piezometer may be installed in the boring; attached plans and conditions are part of this permit Date: August 16, 2011 Permit type: Excavation; boring test pit (single) | Permit status: Permit expired | Expiration date: November 11, 2011 | Permit id: Pa59663-R1 | |||||
SCORE 79 Twenty (20) direct-push borings that are 2-inches in diameter and 16 feet deep. Nine borings (sb1 thru sb9) are located in roadway and grassed areas east of s. Capitol st se northbound lanes in lots 0944, 0943, and 0921, square 5861. Eleven borings are located in grassed areas to the south of s. Capitol street se and suitland pkwy intersection, south of lot 0921, square 5861. Inspection fees and deposit fees to be waived per mr. Amaya and mr. Schoon direction. Date: February 24, 2010 Contractor: Janet Frey Permit type: Excavation; boring test pit (single), excavation; boring test pit (each addl) | Permit status: Cancel/withdrawn | Expiration date: June 1, 2010 | |||||
SCORE 89 Eighteen (18) direct-push borings that are 2-inches in diameter and 16 feet deep. Five borings (sb1 thru sb5) are located in grassed areas east of s. Capitoal st. Se northbound lanes in lots 0944, 0943, and 0921, square 5861. Thirteen borings are located in grassed areas to the south of s. Capitoal st se and suitland pkway intersection, south of lot 0921, square 5861 (sb6 thru sb18). Hours permitted to work are between 9:30am to 3:30pm monday thru friday. Date: March 3, 2010 Contractor: Urs Permit type: Excavation; boring test pit (single), excavation; boring test pit (each addl) | Permit status: Permit expired | Expiration date: April 29, 2010 | Permit id: Pa54256 | |||||
SCORE 79 Six (6) geotechnical borings that are 6-8 inches in diameter and 40- feet deep. Two borings (sb-1 and sb-2) are in grassed areas in lot 0942, square 5861, and four borings (sb-3 through sb-6) are in grassed areas in lot 0921 and south of lot 0921, square 5861. All borings are located to the east of the northbound lanes of s. Capitol st. Se near its intersection with suitland parkway. Hours permitted to work are between 9: am to 3: pm monday thru friday. Date: March 10, 2010 Contractor: Urs Corp Client: Siva Balu | Permit type: Excavation; boring test pit (single), excavation; boring test pit (each addl) | Permit status: Permit expired | Expiration date: May 6, 2010 | Permit id: Pa54363 | |||||
SCORE 79 Six (6) geotechnical borings that are 6-8 inches in diameter and 40- feet deep. Two borings (sb-1 and sb-2) are in grassed areas in lot 0942, square 5861, and four borings (sb-3 through sb-6) are in grassed areas in lot 0921 and south of lot 0921, square 5861. All borings are located to the east of the northbound lanes of s. Capitol st. Se near its intersection with suitland parkway. Date: April 21, 2010 Contractor: Urs Corp Client: Siva Balu | Permit type: Excavation; boring test pit (single), excavation; boring test pit (each addl) | Permit status: Permit expired | Expiration date: June 20, 2010 | Permit id: Pa54363-R1 | |||||
One (1) geotechnical boring that is 8 inches in diameter and approximately 1 feet deep. The boring is located on the shoulder along howard road se, next to its intersection with the exit ramp from anacostia freeway se. Attached plans and conditions are part of this permit; traffic control plan (tcp) expiration date same as public space permit expiration date Date: July 20, 2010 Permit type: Excavation; boring test pit (single) | Permit status: Permit expired | Expiration date: October 9, 2010 | Permit id: Pa56675 | |||||
One (1) geotechnical boring that is approximately 8 inches in diamter and approximately 1 feet deep. The borign is located in a grassed area to the north of the westbound lanes of suitland parkway se, next to its underpass of anacostia freeway (south of lot 0089, square 5861). Attached plans and conditions are part of this permit; traffic control plan (tcp) expiration date same as public space permit expiration date; must contact system inspection oversight division (siod) before start of work and before permanent restoration of public space at 202-645-7050; must apply and obtain occupancy permit before start of work. Date: August 19, 2010 Permit type: Excavation; boring test pit (single) | Permit status: Permit expired | Expiration date: December 20, 2010 | Permit id: Pa57268 | |||||
1st - extension of permit number pa 56673; one (1) geotechnical boring that is 8 inches in diameter and approximately 1 feet deep. The boring is located on the shoulder along howard road se, next to its intersection with the exit ramp from anacostia freeway se. Attached plans and conditions are part of this permit; traffic control plan (tcp) expiration date same as public space permit expiration date Date: September 22, 2010 Permit type: Excavation; boring test pit (single) | Permit status: Cancel/withdrawn | Expiration date: February 10, 2011 | |||||
Refer to approved traffic control plan (tcp) for permitted hours of work; tcp expiration date same as public space permit expiration date; two (2) geotechnial borings, identified as arc-18 and arc-19, that are approximately 8 inches in diameter and approximately 155 feet deep and 1 feet deep, respectively. The borings are located in the grass on the north side of the parking garage entrance road at the anacostia metro station. Both are located in lot 0817, square 5788; attached plans and conditions are part of this permit; must contact system inspection oversight division (siod) before start of work and before permanent restoration of public space at 202-645-7050 Date: November 4, 2010 Permit type: Excavation; boring test pit (single), excavation; boring test pit (each addl) | Permit status: Permit expired | Expiration date: May 29, 2011 | Permit id: Pa58439 | |||||
Refer to approved traffic control plan (tcp) for permitted hours of work; tcp expiration date same as public space permit expiration date; one (1) geotechnical boring identified as arc-21 that is approximately 8 inches in diameter and approximately 1 feet deep. A monitoring well or vibrating piezometer may be installed in the boring; attached plans and conditions are part of this permit; must contact system inspection oversight division (siod) before start of work and before permanent restoration of public space at 202-645-7050 Date: January 25, 2011 Permit type: Excavation; boring test pit (single) | Permit status: Permit expired | Expiration date: August 13, 2011 | Permit id: Pa59663 |