Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
SCORE 89 Fire sprinkler monitoring system with elevator recall includes addition of 1 control panel 1 pull station 1 horn strobe 6 smoke detectors 2 heat detectors 2 monitor modules and 4 relays Current use: Office | Permit id: #200806124315 | |||||
SCORE 99 T-mobile proposes to remove 2 (e) antennas and replace with 2 new antennas 2 taller. The antennas will not increase in height on (e) bldg. No other changes are proposed at this time Date: March 27, 2009 Contractor: Undecided Undecided Current use: Office | Permit id: #200903275004 | |||||
SCORE 99 Interior demo only non structural partitions only per ab-017 Current use: Office | Permit id: #201107140188 | |||||
Replace extg damaged front entry storefront doors. Date: July 25, 2011 Value: $5,000 Current use: Office | Permit id: #201107250968 | |||||
SCORE 99 Ground floor lobby new partition & entry door new ada barrier upgrade bathroom to full accessibility. Current use: Office | Permit id: #201107261112 | |||||
SCORE 100 1st floor -installation of additional sprinkler head at the new soffit. Current use: Office | Permit id: #201108092039 | |||||
SCORE 99 2nd floor only: new partitions for office & new conference rooms new breakroom & appliances new flooring & wall finishes. Current use: Office | Permit id: #201203095798 | |||||
SCORE 100 2nd floor-fire sprinkler t. I-add 6 pendent sprinkler 3 new earthquake braces. T. I pa# 2012-0309-5798 Current use: Office | Permit id: #201204047488 | |||||
SCORE 99 Revision to pa# 2012-0309-5798-replace cover sheet remove note asking for fire alarm submittal on sheet a0. 1-note #3 Current use: Office | Permit id: #201205311578 | |||||
SCORE 82 To obtain final inspection for work approved under pa # 200806124315. All work is complete. Current use: Office | Permit id: #201206112327 | |||||
SCORE 96 Erect non-electric double faced projecting sign Current use: Office | Permit id: #201312234882 | |||||
SCORE 99 Ground floor lobby new partition & entry door new ada barrier upgrade bathroom to full accessibility. Permit type: Building permit | Expiration date: February 3, 2012 | Current use: Office | Permit id: #201107261112 | |||||
Permit to operate boiler Date: May 7, 2003 Permit status: Issued | Expiration date: May 7, 2003 | Permit id: 21128 | |||||
Permit to operate boiler Date: June 10, 2015 Permit status: Issued | Expiration date: June 10, 2015 | Permit id: 80672 | |||||
Permit to operate boiler Date: June 10, 2005 Permit status: Issued | Expiration date: June 10, 2005 | Permit id: 28703 | |||||
Permit to operate boiler Date: January 19, 2011 Permit status: Issued | Expiration date: January 19, 2011 | Permit id: 54852 | |||||
Permit to operate boiler Date: May 23, 2012 Permit status: Issued | Expiration date: May 23, 2012 | Permit id: 62157 | |||||
Permit to operate boiler Date: June 6, 2013 Permit status: Issued | Expiration date: June 6, 2013 | Permit id: 68327 | |||||
SCORE 95 Tenant improvement - 2nd floor. Install approximately (25) light fixtures (14) switches (30) wall receptacles and (1) floor receptacle. Date: March 27, 2012 Contractor: Corish Electric Corporation Permit type: Electrical permit | Permit status: Issued | Permit id: Ew20120327001 | |||||
SCORE 95 Data cabling - 2nd floor tenant approximately 1 cables Date: June 5, 2012 Contractor: Corish Electric Corporation Permit type: Electrical permit | Permit status: Complete | Permit id: Ew20120524941 | |||||
Permit to operate boiler Date: April 24, 2002 Permit status: Issued | Expiration date: April 24, 2002 | Permit id: 17658 | |||||
Permit to operate boiler Date: June 10, 2004 Permit status: Issued | Expiration date: June 10, 2004 | Permit id: 25028 | |||||
Permit to operate boiler Date: October 1, 2010 Permit status: Issued | Expiration date: October 1, 2010 | Permit id: 52534 | |||||
SCORE 100 Reinstallation of 2 lav sinks one urinal one toilet. Date: August 9, 2011 Contractor: A M West Mechanical Inc Permit type: Plumbing permit | Permit status: Complete | Permit id: Pp20110809125 | |||||
SCORE 100 2nd floor-fire sprinkler t. I-add 6 pendent sprinkler 3 new earthquake braces. T. I pa# 2012-0309-5798 Permit type: Building permit | Expiration date: August 4, 2012 | Current use: Office | Permit id: #201204047488 | |||||
SCORE 100 1st floor -installation of additional sprinkler head at the new soffit. Permit type: Building permit | Expiration date: December 9, 2011 | Current use: Office | Permit id: #201108092039 | |||||
SCORE 96 Erect non-electric double faced projecting sign Permit type: Building permit | Expiration date: April 27, 2014 | Permit id: #201312234882 | |||||
SCORE 99 Interior demo only non structural partitions only per ab-017 Permit type: Building permit | Expiration date: January 18, 2012 | Current use: Office | Permit id: #201107140188 | |||||
Replace extg damaged front entry storefront doors. Date: July 25, 2011 Value: $5,000 Permit type: Building permit | Current use: Office | Permit id: #201107250968 | |||||
Otc alterations permit Permit status: Filed | Completion date: July 26, 2011 | Permit id: 201107261104 | |||||
Permit to operate boiler Date: September 19, 2016 Permit status: Issued | Expiration date: September 19, 2016 | Permit id: 90103 | |||||
SCORE 82 To obtain final inspection for work approved under pa # 200806124315. All work is complete. Permit type: Building permit | Expiration date: October 11, 2012 | Current use: Office | Permit id: #201206112327 | |||||
2nd floor-fire sprinkler t. I-add 6 pendent sprinkler 3 new earthquake braces. T. I pa# 2012-0309-5798 Value: $3,500 Permit type: Otc alterations permit | Permit status: Complete | Completion date: April 4, 2012 | Expiration date: March 30, 2013 | Current use: Office | Permit id: 201204047488 | |||||
Permit to operate boiler Date: June 23, 2006 Permit status: Issued | Expiration date: June 23, 2006 | Permit id: 32825 | |||||
Permit to operate boiler Date: November 12, 2009 Permit status: Issued | Expiration date: November 12, 2009 | Permit id: 47716 | |||||
SCORE 99 2nd floor only: new partitions for office & new conference rooms new breakroom & appliances new flooring & wall finishes. Permit type: Building permit | Expiration date: March 28, 2013 | Current use: Office | Permit id: #201203095798 | |||||
Permit to operate boiler Date: August 1, 2014 Permit status: Issued | Expiration date: August 1, 2014 | Permit id: 75733 | |||||
SCORE 99 Revision to pa# 2012-0309-5798-replace cover sheet remove note asking for fire alarm submittal on sheet a0. 1-note #3 Permit type: Building permit | Expiration date: September 30, 2012 | Current use: Office | Permit id: #201205311578 | |||||
Install wireless facility-1 pqnel antenna 1 equip unit Value: $18,000 Permit type: Otc alterations permit | Permit status: Expired | Completion date: August 12, 1999 | Expiration date: February 12, 2000 | Current use: Office | Permit id: 9916654 | |||||
Ground floor lobby new partition & entry door new ada barrier upgrade bathroom to full accessibility. Value: $10,000 Permit type: Otc alterations permit | Permit status: Complete | Completion date: July 26, 2011 | Expiration date: July 28, 2012 | Current use: Office | Permit id: 201107261112 | |||||
Remove existing panel antenna and assoc. Equip. Install two new antennas & two equip cabinets/roof Value: $50,000 Permit type: Additions alterations or repairs | Permit status: Complete | Completion date: September 20, 2002 | Expiration date: October 3, 2003 | Current use: Office | Permit id: 200209207135 | |||||
Renew pas 9608921 96143 9605812 9621967 9613358 for final Value: $100 Permit type: Otc alterations permit | Permit status: Complete | Completion date: June 13, 1997 | Expiration date: October 13, 1997 | Current use: Office | Permit id: 9710803 | |||||
Fire sprinkler monitoring system with elevator recall includes addition of 1 control panel 1 pull station 1 horn strobe 6 smoke detectors 2 heat detectors 2 monitor modules and 4 relays Value: $7,800 Permit type: Otc alterations permit | Permit status: Expired | Completion date: June 12, 2008 | Expiration date: December 12, 2008 | Current use: Office | Permit id: 200806124315 | |||||
Remove 2 (e) antennas and replace with 2 new antennas 2" taller. The antennas will not increase in height on (e) bldg. Value: $10,000 Permit type: Additions alterations or repairs | Permit status: Cancelled | Completion date: March 27, 2009 | Current use: Office | Permit id: 200903275004 | |||||
Revision to pa# 2012-0309-5798-replace cover sheet remove note asking for fire alarm submittal on sheet a0. 1-note #3 Value: $1 Permit type: Otc alterations permit | Permit status: Complete | Completion date: May 31, 2012 | Expiration date: May 26, 2013 | Current use: Office | Permit id: 201205311578 | |||||
Street space Permit type: Otc alterations permit | Permit status: Issued | Completion date: January 14, 2005 | Permit id: M30821 | |||||
2nd floor only: new partitions for office & new conference rooms new breakroom & appliances new flooring & wall finishes. Value: $110,000 Permit type: Otc alterations permit | Permit status: Complete | Completion date: March 9, 2012 | Expiration date: March 13, 2015 | Current use: Office | Permit id: 201203095798 | |||||
Repair rebar four concrete Value: $800 Permit type: Otc alterations permit | Permit status: Expired | Completion date: November 12, 1996 | Expiration date: March 12, 1997 | Current use: Office | Permit id: 9621967 | |||||
Streetspace and sidewalk Permit type: Otc alterations permit | Permit status: Issued | Completion date: January 5, 2006 | Permit id: M35863 | |||||
1st floor -installation of additional sprinkler head at the new soffit. Value: $600 Permit type: Otc alterations permit | Permit status: Complete | Completion date: August 9, 2011 | Expiration date: August 3, 2012 | Current use: Office | Permit id: 201108092039 | |||||
Relocation of fire sprinklers/ground floor Value: $1,200 Permit type: Otc alterations permit | Permit status: Expired | Completion date: July 24, 1996 | Expiration date: November 24, 1996 | Current use: Office | Permit id: 9613358 | |||||
Cti-2 1/f el me Value: $28,000 Permit type: Additions alterations or repairs | Permit status: Complete | Completion date: October 25, 1996 | Expiration date: November 6, 1997 | Current use: Office | Permit id: 9620632 | |||||
Street space. Permit type: Otc alterations permit | Permit status: Issued | Completion date: March 8, 2012 | Permit id: M306447 | |||||
To obtain final inspection for work approved under pa # 200806124315. All work is complete. Value: $1 Permit type: Otc alterations permit | Permit status: Issued | Completion date: June 11, 2012 | Expiration date: June 6, 2013 | Current use: Office | Permit id: 201206112327 | |||||
Erect non-electric double faced projecting sign Value: $500 Permit type: Sign-errect | Permit status: Complete | Completion date: December 23, 2013 | Expiration date: December 22, 2014 | Current use: Office | Permit id: 201312234882 | |||||
Express p/c revise 2nd flr to single tenant occupancy Value: $80,000 Permit type: Additions alterations or repairs | Permit status: Complete | Completion date: May 13, 1992 | Expiration date: June 16, 1993 | Current use: Office | Permit id: 9207811 | |||||
Cti-1 1stfl el me sp Value: $150,000 Permit type: Additions alterations or repairs | Permit status: Expired | Completion date: May 22, 1996 | Expiration date: June 4, 1997 | Current use: Office | Permit id: 9608921 | |||||
Cti-1 ground floor revision to appl #9608921 excluding ramp Value: $1 Permit type: Otc alterations permit | Permit status: Expired | Completion date: August 6, 1996 | Expiration date: December 6, 1996 | Current use: Office | Permit id: 9614320 | |||||
Interior demo only non structural partitions only per ab-017 Value: $22,000 Permit type: Otc alterations permit | Permit status: Complete | Completion date: July 14, 2011 | Expiration date: July 12, 2012 | Current use: Office | Permit id: 201107140188 | |||||
Minor interior demolition all exits to be maintained Value: $5,000 Permit type: Otc alterations permit | Permit status: Expired | Completion date: April 5, 1996 | Expiration date: August 5, 1996 | Current use: Office | Permit id: 9605812 | |||||
Remove for demolition only Value: $8,000 Permit type: Additions alterations or repairs | Permit status: Complete | Completion date: April 30, 1992 | Expiration date: April 22, 1993 | Current use: Office | Permit id: 9206887 | |||||
Permit to operate boiler Date: July 29, 2008 Permit status: Issued | Expiration date: July 29, 2008 | Permit id: 41574 | |||||
Remove existing panel antenna and assoc. Equip. Install two new antennas & two equip cabinets roof Date: September 20, 2002 Value: $50,000 Permit type: Additions alterations or repairs | Permit status: Complete | Expiration date: September 20, 2002 | Current use: Office | Permit id: 200209207135 | |||||
Permit to operate boiler Date: July 27, 2007 Permit status: Issued | Expiration date: July 27, 2007 | Permit id: 37513 | |||||
Relocation of fire sprinklers ground floor Date: July 24, 1996 Value: $1,200 Permit type: Otc alterations permit | Permit status: Expired | Expiration date: July 24, 1996 | Current use: Office | Permit id: 9613358 | |||||
Cti-2 1 f el me Date: October 25, 1996 Value: $28,000 Permit type: Additions alterations or repairs | Permit status: Complete | Expiration date: October 25, 1996 | Current use: Office | Permit id: 9620632 | |||||
Express p c revise 2nd flr to single tenant occupancy Date: May 13, 1992 Value: $80,000 Permit type: Additions alterations or repairs | Permit status: Complete | Expiration date: May 13, 1992 | Current use: Office | Permit id: 9207811 | |||||
Add one fiber box inside (e) t-mobile equipment lease area 5 cables Permit status: Complete | Permit id: E200912304614 | |||||
Data cabling - 2nd floor tenant approximately 1 cables Permit status: Complete | Permit id: Ew20120524941 | |||||
1st floor minor remodel. Install (8) new fluorescent light fixtures. Replace (5) existing exit signs with new exit em combo fixtures add (2) em light fixtures in bathrooms. Install (4) light switches for new lights. Install (4) floor receptacles (flush with floor) to replace conduit stub ups to removed furniture systems (in the same locations). Install missing covers on existing junction boxes and replace floor box trim as needed. Permit status: Complete | Permit id: Ew20110908644 | |||||
Tenant improvement - 2nd floor. Install approximately (25) light fixtures (14) switches (30) wall receptacles and (1) floor receptacle. Permit status: Complete | Permit id: Ew20120327001 | |||||
3rd flr: 2 circuits #12- amps for fa panel and elev. Control; panels switchboards 1 fa control fire alarm device 1 facp 6 relays 5 smoke detectors 4 heat detectors 1 speaker strobe 1 pull station cei wo #101295 eb- 1 new 2 amps disconnect Permit status: Complete | Permit id: E200811063389 | |||||
2ndfloor-firesprinklert. I-add6pendentsprinkler 3newearthquakebraces. T. Ipa#2012-0309-5798 Date: April 4, 2012 Permit status: Complete | Expiration date: April 4, 2012 | Permit id: Pp20120404605 | |||||
Reinstallationof2lavsinks oneurinal onetoilet. Date: August 9, 2011 Permit status: Complete | Expiration date: August 9, 2011 | Permit id: Pp20110809125 | |||||
Installsinkw pump. Rough&finishplumbing. Installnewfixturesatmens&womensrestroom. Date: March 29, 2012 Permit status: Complete | Expiration date: March 29, 2012 | Permit id: Pp20120329502 | |||||
Data cabling - 2nd floor tenant approximately 1 cables Permit status: Complete | Permit id: Ew20120524941 | |||||
Tenant improvement - 2nd floor. Install approximately (25) light fixtures (14) switches (30) wall receptacles and (1) floor receptacle. Permit status: Complete | Permit id: Ew20120327001 | |||||
Add one fiber box inside (e) t-mobile equipment lease area 5 cables Permit status: Complete | Permit id: E200912304614 | |||||
1st floor minor remodel. Install (8) new fluorescent light fixtures. Replace (5) existing exit signs with new exit em combo fixtures add (2) em light fixtures in bathrooms. Install (4) light switches for new lights. Install (4) floor receptacles (flush with floor) to replace conduit stub ups to removed furniture systems (in the same locations). Install missing covers on existing junction boxes and replace floor box trim as needed. Permit status: Complete | Permit id: Ew20110908644 | |||||
3rd flr: 2 circuits #12- amps for fa panel and elev. Control; panels switchboards 1 fa control fire alarm device 1 facp 6 relays 5 smoke detectors 4 heat detectors 1 speaker strobe 1 pull station cei wo #101295 eb- 1 new 2 amps disconnect Permit status: Complete | Permit id: E200811063389 | |||||
Permit to operate boiler Date: October 10, 2017 Permit status: Issued | Expiration date: October 10, 2017 | Permit id: 97550 | |||||
Minor interior demolition, all exits to be maintained Date: April 5, 1996 Value: $5,000 Permit type: Otc alterations permit | Expiration date: April 5, 1996 | Current use: Office | Permit id: 9605812 | |||||
Cti-1 1stfl,el,me,sp Date: June 4, 1996 Value: $150,000 Permit type: Additions alterations or repairs | Expiration date: May 22, 1996 | Current use: Office | Permit id: 9608921 | |||||
Cti-1 ground floor, revision to appl #9608921,excluding ramp Date: August 6, 1996 Value: $1 Permit type: Otc alterations permit | Expiration date: August 6, 1996 | Current use: Office | Permit id: 9614320 | |||||
Renew pas 9608921,9614320,9605812,9621967,9613358 for final Date: June 13, 1997 Value: $100 Permit type: Otc alterations permit | Completion date: October 15, 1997 | Expiration date: June 13, 1997 | Current use: Office | Permit id: 9710803 | |||||
Install wireless facility-1 pqnel,antenna, 1 equip unit Date: August 12, 1999 Value: $18,000 Permit type: Otc alterations permit | Expiration date: August 12, 1999 | Current use: Office | Permit id: 9916654 | |||||
1 f- construction of office and conference room. N a ordinance #155-13 Date: March 30, 2017 Value: $40,000 Permit type: Otc alterations permit | Completion date: July 7, 2017 | Expiration date: March 29, 2017 | Current use: Office | Permit id: 201703292737 | |||||
Title 24 electrical at 1 office and 1 conf room, 2 lights, 2 switches, 2 duplex circuits 201703292737 Date: May 8, 2017 Value: $2,000 Permit type: Otc alterations permit | Completion date: July 7, 2017 | Expiration date: May 8, 2017 | Current use: Office | Permit id: 201705085959 | |||||
Fire sprinkler monitoring system with elevator recall includes addition of 1 control panel, 1 pull station, 1 horn strobe, 6 smoke detectors, 2 heat detectors, 2 monitor modules and 4 relays Date: June 12, 2008 Value: $7,800 Permit type: Otc alterations permit | Expiration date: June 12, 2008 | Current use: Office | Permit id: 200806124315 | |||||
Interior demo only, non structural partitions only, per ab-017 Date: July 18, 2011 Value: $22,000 Permit type: Otc alterations permit | Completion date: August 10, 2011 | Expiration date: July 14, 2011 | Current use: Office | Permit id: 201107140188 | |||||
Ground floor lobby new partition & entry door, new ada barrier, upgrade bathroom to full accessibility. Date: August 3, 2011 Value: $10,000 Permit type: Otc alterations permit | Completion date: September 1, 2011 | Expiration date: July 26, 2011 | Current use: Office | Permit id: 201107261112 | |||||
2nd floor only: new partitions for office & new conference rooms, new breakroom & appliances, new flooring & wall finishes. Date: March 28, 2012 Value: $110,000 Permit type: Otc alterations permit | Completion date: June 13, 2012 | Expiration date: March 9, 2012 | Current use: Office | Permit id: 201203095798 | |||||
2nd floor-fire sprinkler t. I-add 6 pendent sprinkler, 3 new earthquake braces. T. I pa# 2012-0309-5798 Date: April 4, 2012 Value: $3,500 Permit type: Otc alterations permit | Completion date: July 5, 2012 | Expiration date: April 4, 2012 | Current use: Office | Permit id: 201204047488 | |||||
Revision to pa# 2012-0309-5798-replace cover sheet, remove note asking for fire alarm submittal on sheet a0. 1-note #3 Date: May 31, 2012 Value: $1 Permit type: Otc alterations permit | Completion date: June 13, 2012 | Expiration date: May 31, 2012 | Current use: Office | Permit id: 201205311578 | |||||
1st floor minor remodel. Install (8) new fluorescent light fixtures. Replace (5) existing exit signs with new exit em combo fixtures, add (2) em light fixtures in bathrooms. Install (4) light switches for new lights. Install (4) floor receptacles (flush with floor) to replace conduit stub ups to removed furniture systems (in the same locations). Install missing covers on existing junction boxes and replace floor box trim as needed. Date: September 8, 2011 Permit status: Complete | Completion date: September 13, 2011 | Permit id: Ew20110908644 | |||||
Tenant improvement - 2nd floor. Install approximately (25) light fixtures, (14) switches, (30) wall receptacles, and (1) floor receptacle. Date: March 27, 2012 Permit status: Complete | Completion date: June 5, 2012 | Permit id: Ew20120327001 | |||||
1 f- construction of office and conference room. 2 lights, 2 switches, 2 duplex, 2-20amp circuits. Date: April 6, 2017 Permit status: Complete | Completion date: July 7, 2017 | Permit id: E201704064120 | |||||
Data cabling - 2nd floor tenant, approximately 1 cables Date: May 24, 2012 Permit status: Complete | Completion date: June 5, 2012 | Permit id: Ew20120524941 | |||||
3rd flr: 2 circuits, #12- amps for fa panel and elev. Control; panels switchboards 1 fa control, fire alarm device, 1 facp, 6 relays, 5 smoke detectors, 4 heat detectors, 1 speaker strobe, 1 pull station, cei wo #101295, eb- 1 new 2 amps disconnect Date: November 6, 2008 Permit status: Complete | Completion date: January 24, 2011 | Permit id: E200811063389 | |||||
Add one fiber box inside (e) t-mobile equipment lease area, 5 cables Date: December 31, 2009 Permit status: Complete | Completion date: November 30, 2010 | Permit id: E200912304614 | |||||
Install sink w pump. Rough & finish plumbing. Install new fixtures at mens & womens restroom. Date: March 29, 2012 Permit status: Complete | Completion date: May 29, 2012 | Expiration date: March 29, 2012 | Permit id: Pp20120329502 | |||||
2nd floor-fire sprinkler t. I-add 6 pendent sprinkler, 3 new earthquake braces. T. I pa# 2012-0309-5798 Date: April 4, 2012 Permit status: Complete | Completion date: April 19, 2012 | Expiration date: April 4, 2012 | Permit id: Pp20120404605 | |||||
Reinstallation of 2 lav sinks, one urinal, one toilet. Date: August 9, 2011 Permit status: Complete | Completion date: August 25, 2011 | Expiration date: August 9, 2011 | Permit id: Pp20110809125 | |||||
SCORE 100 1 f- construction of office and conference room. 2 lights 2 switches 2 duplex 2-20amp circuits. Date: April 6, 2017 Contractor: Benson And Son Electric Permit type: Electrical permit | Permit status: Issued | Permit id: E201704064120 | |||||
SCORE 86 Install sink w/ pump. Rough & finish plumbing. Install new fixtures at mens & womens restroom. Date: March 29, 2012 Contractor: Nicodemus Plumbing And Mechanical Permit type: Plumbing permit | Permit status: Issued | Permit id: Pp20120329502 | |||||
SCORE 100 1 f- construction of office and conference room. N a ordinance #155-13 Permit type: Building permit | Expiration date: March 30, 2018 | Current use: Office | Permit id: #201703292737 | |||||
SCORE 100 Title 24 electrical at 1 office and 1 conf room 2 lights 2 switches 2 duplex circuits 201703292737 Permit type: Building permit | Expiration date: September 8, 2017 | Current use: Office | Permit id: #201705085959 | |||||
SCORE 95 1st floor minor remodel. Install (8) new fluorescent light fixtures. Replace (5) existing exit signs with new exit/em combo fixtures add (2) em light fixtures in bathrooms. Install (4) light switches for new lights. Install (4) floor receptacles (flush with floor) to replace conduit stub ups to removed furniture systems (in the same locations). Install missing covers on existing junction boxes and replace floor box trim as needed. Date: September 13, 2011 Contractor: Corish Electric Corporation Permit type: Electrical permit | Permit status: Complete | Permit id: Ew20110908644 | |||||
SCORE 99 2nd floor-fire sprinkler t. I-add 6 pendent sprinkler 3 new earthquake braces. T. I pa# 2012-0309-5798 Date: April 4, 2012 Contractor: Sure Fire Protection Permit type: Plumbing permit | Permit status: Complete | Permit id: Pp20120404605 |