Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Proposal to renovate building with limited changes to exterior openings per application & drawings received 02/27/15. Date: February 27, 2015 Permit type: Vcc general work | Permit status: Vcc arc meeting | Current use: Half of a party wall double | Permit id: 15-06099-Vcgen | |||||
Historical import type: enforcement vcc permit generaluser: cabergtracking: 86110683098status: permit issuedstatus date: 1/30/2012 12:00: amowner: weisman clio bowner address: et al 937 dauphine st, new orleans, la 70116owner edited by: 1/30/2012 by caberg-replace deteriorated 6-inch half-round gutter with copper 6-inch half-round gutter (abat-vent)-replace deteriorated standing seam roof on abat-vent with new galvanized standing seam roof.-replace 4 pieces of rotten bead board soffit with new bead board to match existing.-replace 3 broken roof slates (fire free), from existing stock.-re-flash chimney. Note: this permit is to resolve a violation concerning work begun without a permitfor which a stop work order was issued. Date: January 30, 2012 Permit type: Vcc general work | Permit status: Permit finaled | Completion date: April 4, 2014 | Current use: Unknown | Permit id: Vccp-12-0084 | |||||
Historical import type: enforcement vcc permit paintuser: hirvintracking: 86140234454status: permit issuedstatus date: 1/18/2012 12:00: amowner: weisman clio bowner address: et al 937 dauphine st, new orleans, la 70116owner edited by: 1/18/2012 by hirvinshutters & gates... Medium shade of blue (great falls, sw 6496; oceanside, sw 6496 or loch blue, sw 6502), semiglosspermit includes approval for repair of shutter slats & gate hinges Date: January 18, 2012 Permit type: Vcc general work | Permit status: Permit finaled | Completion date: April 4, 2014 | Current use: Unknown | Permit id: Vccp-12-0025 | |||||
SCORE 97 Interior demolition of a 2 story dwelling,renovation plans to follow. No use and occupancy. Remove chimney. Permit type: Interior demolition | Permit status: Permit issued | Expiration date: March 16, 2015 | Current use: Half of a party wall double | Permit id: 14-28805-Demi | |||||
SCORE 86 Rewire Date: June 15, 2016 Contractor: Chuck Ransdell Permit type: Electrical repair / replacement / addition | Permit status: Permit issued | Expiration date: December 16, 2016 | Current use: Single family | Permit id: 16-19827-Erpr | |||||
Historical import type: enforcement vcc permit paintuser: cabergtracking: 86190646839status: permit issuedstatus date: 2/3/2012 12:00: amowner: weisman clio bowner address: et al 937 dauphine st, new orleans, la 70116owner edited by: 2/3/2012 by cabergwooden elements including fascia/soffit/outriggers of gallery..., semigloss: antique white, to match existing Date: February 3, 2012 Permit type: Vcc paint | Permit status: Permit finaled | Completion date: April 4, 2014 | Current use: Unknown | Permit id: Vccp-12-0109 | |||||
SCORE 59 Interior renovation incorporating new footings and utilities. Vcc permit 15-06099 Date: January 8, 2016 Value: $315,000 Permit type: Renovation (structural) | Permit status: Permit approval letter | Expiration date: October 11, 2016 | Current use: Single family | Permit id: 16-00744-Rnvs | |||||
Building approval for painting the interior and exterior of residence. Date: October 5, 2016 Permit type: Lead-based paint form | Permit status: Application submitted | Current use: Half of a party wall double | Permit id: 16-33098-Lead | |||||
Proposal to renovate building with limited changes to exterior openings per application & drawings received 02 27 15. Date: February 27, 2015 Permit type: Vcc general work | Permit status: Permit expired due to ina | Completion date: January 4, 2017 | Current use: Half of a party wall double | Permit id: 15-06099-Vcgen | |||||
SCORE 59 Interior renovation incorporating new footings and utilities. Vcc permit 15-06099 Date: January 8, 2016 Value: $315,000 Permit type: Renovation (structural) | Permit status: Permit approval letter | Expiration date: October 11, 2016 | Current use: Single family | Permit id: 16-00744-Rnvs | |||||
To prepare for painting by sanding (rotary sanders cannot be used), making minor millwork and masonry repairs as necessary to match existing conditions (masonry mix must be soft, with maximum portland cement content not to exceed 1 part to 12) and to paint as follows: walls: sw 6253 "olympus white," flat or satin finishwooden elements including doors, windows, frames, shop windows, fascia soffit outriggers of gallery: sw 7002 "downy," semiglossshutters: sw 7073 "network gray" ,semiglossfailure to exactly match permit specified colors will result in a vcc violation and mandated repainting. This permit prohibits the application of the following exterior coating materials and paints: sealers, ceramic coatings paints, elastomeric coatings paints, waterproofing water repellent coatings. Date: October 5, 2016 Permit type: Vcc paint | Permit status: Permit issued | Expiration date: April 13, 2017 | Current use: Single family | Permit id: 16-33091-Vcpnt | |||||
Approval of painting in the interior and exterior of residence in the v. C. C. Date: October 6, 2016 Permit type: Vcc paint | Permit status: Voided - duplicate permit | Completion date: October 13, 2016 | Current use: Half of a party wall double | Permit id: 16-33098-Vcpnt | |||||
Hvac Date: October 3, 2016 Permit type: Vcc general work | Permit status: Returned for revision | Current use: Single family | Permit id: 16-32342-Vcgen | |||||
SCORE 93 Hvac Permit type: Renovation (non-structural) | Permit status: Application submitted | Current use: Single family | Permit id: 16-32342-Rnvn | |||||
SCORE 93 Ajm311, c k 6816 ken 415-71 2waf 2ac Date: October 31, 2016 Contractor: Kenneth Blum Permit type: Mechanical hvac | Permit status: Permit issued | Expiration date: April 30, 2017 | Current use: Half of a party wall double | Permit id: 16-36127-Hvac | |||||
Historical import type: enforcement vcc permit paintuser: hirvintracking: 86140234454status: permit issuedstatus date: 1 18 2012 12:00: amowner: weisman clio bowner address: et al 937 dauphine st, new orleans, la 70116owner edited by: 1 18 2012 by hirvinshutters & gates... Medium shade of blue (great falls, sw 6496; oceanside, sw 6496 or loch blue, sw 6502), semiglosspermit includes approval for repair of shutter slats & gate hinges Date: January 18, 2012 Permit type: Vcc general work | Permit status: Permit finaled | Completion date: April 4, 2014 | Current use: Unknown | Permit id: Vccp-12-0025 | |||||
Historical import type: enforcement vcc permit generaluser: cabergtracking: 86110683098status: permit issuedstatus date: 1 30 2012 12:00: amowner: weisman clio bowner address: et al 937 dauphine st, new orleans, la 70116owner edited by: 1 30 2012 by caberg-replace deteriorated 6-inch half-round gutter with copper 6-inch half-round gutter (abat-vent)-replace deteriorated standing seam roof on abat-vent with new galvanized standing seam roof.-replace 4 pieces of rotten bead board soffit with new bead board to match existing.-replace 3 broken roof slates (fire free), from existing stock.-re-flash chimney. Note: this permit is to resolve a violation concerning work begun without a permitfor which a stop work order was issued. Date: January 30, 2012 Permit type: Vcc general work | Permit status: Permit finaled | Completion date: April 4, 2014 | Current use: Unknown | Permit id: Vccp-12-0084 | |||||
Historical import type: enforcement vcc permit paintuser: cabergtracking: 86190646839status: permit issuedstatus date: 2 3 2012 12:00: amowner: weisman clio bowner address: et al 937 dauphine st, new orleans, la 70116owner edited by: 2 3 2012 by cabergwooden elements including fascia soffit outriggers of gallery..., semigloss: antique white, to match existing Date: February 3, 2012 Permit type: Vcc paint | Permit status: Permit finaled | Completion date: April 4, 2014 | Current use: Unknown | Permit id: Vccp-12-0109 | |||||
Repair replace brick party wall to match existing to stabilize. Install 3 x 3 brick landings with one step each at rear doors of property to replace non-conforming conc. Steps. Replace non-conforming rear wall mounted light fixtures with vcc approved fixtures. Remove non-conforming outdoor stereo speakers--not to be replaced. Date: May 30, 2017 Value: $7,000 Permit type: Renovation (non-structural) | Permit status: Application submitted | Current use: Single family | Permit id: 17-18830-Rnvn | |||||
To resolve violations, per attached materials stamped vcc approved 09 15 17, as follows:remove failing masonry wall on burgundy-side property line, and 4-0" along st. Philip property line. Install new 10-0" masonry wall, with 4" cmu and brick veneer (reuse existing bricks where possible), and portland cement mortar cap. All other mortar to be vcc mortar formula (attached). Remove existing unpermitted stoops and install two masonry stoops. Remove existing speakers and flood lights and install remcraft 1 series fixtures in existing locations. All fixtures shall use lamps with the following criteria: 3000k color temperature, 80+ color rendering index, and 600-8 lumens per bulb. Date: May 31, 2017 Permit type: Vcc general work | Permit status: Permit issued | Expiration date: March 15, 2018 | Current use: Single family | Permit id: 17-18830-Vcgen | |||||
SCORE 98 Gas line gas wh sid834-7750 ck2634released Date: May 9, 2016 Contractor: Sidney Lapuyade Permit type: Mechanical fuel gas | Permit status: Certificate of completion | Expiration date: November 9, 2016 | Current use: Half of a party wall double | Permit id: 16-15175-Fgas |