Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Courtyard renovations and new pool ![]() Permit type: Vcc general work | Permit status: Returned for revision | Current use: Single family | Permit id: 16-16283-Vcgen | |||||
Construction zone in front of 916 gov nicholls st 6-20-16 to 6-24-16 per sketch. ![]() Permit type: Dumpster/construction zone | Permit status: Permit issued | Expiration date: December 15, 2016 | Current use: Single family | Permit id: 16-19835-Rczd | |||||
Courtyard renovations per attached plan dated 11 may 2016. Work was applied under application zyctfn. The vcc requested it to be a separate application ![]() ![]() Permit type: Swimming pool | Permit status: Application submitted | Current use: Single family | Permit id: 16-16283-Pool | |||||
Place dumpster in the parking lane in front of 916 governor nicholls st for days, from 07/28/2016 to 08/07/2016. Extending dumpster permit for 8 days from 08/07/2016 to 08/15/2016. Extending dumpster permit for days from 08/16/16 to 09/16/16. ![]() Permit type: Dumpster/construction zone | Permit status: Dpw extension approval | Expiration date: February 2, 2017 | Current use: Single family | Permit id: 16-24079-Rczd | |||||
Following demolition work to be completed per plans and materials stamped vcc approved 06/16/15 and 06/17/15, to include:remove c. 1930s windows and doors in main building and dependencyremove all plaster and furring on gov. Nicholls side courtyard wallremove second floor wood frame addition in courtyardremove brick infill of existing arch on second floor gov. Nicholls side courtyard wallremove c. 1930s staircase in dauphine side passageway. Install plywood barrier to prevent injury. Remove dependency balcony ironwork railing, metal decking, and plywood fasciaremove masonry below dependency window openings as indicatedremove lattice ceiling in alley and loggiaremove all exterior utilities, water heaters in stairwell, and roof ventsremove small patches of stucco from street facade to check condition of underlying brick. Site to be cleared and prepped after work is complete. All removed materials to be reused where possible. All unusable material to be disposed of off site. Note: this permi ![]() Permit type: Vcc general work | Permit status: Vcc arc meeting | Expiration date: December 16, 2015 | Current use: Single family | Permit id: 15-07229-Vcgen | |||||
Following demolition work to be completed per plans and materials stamped vcc approved 06/16/15, to include:remove c. 1930s windows and doors in main building and dependencyremove second floor wood frame addition in courtyardremove dependency balcony ironwork railingremove masonry below dependency window openings as indicatedremove lattice ceiling in alley and loggiaremove all exterior utilitiesremove c. 1930s staircase in passageway ![]() ![]() Permit type: Renovation (structural) | Permit status: Application submitted | Current use: Single family | Permit id: 15-07229-Rnvs | |||||
Following work to be completed per plans and materials stamped vcc approved 07/21/15, to include:removal of all c. 1930s masonry infill in main building and dependency, restoring openings to their original sizes,removal of masonry as indicated on plans, for carriageway entrance on gov. Nicholls elevation,bricking-in of non-original, c. 1930s openings. Restore decaying parapets by removing and resetting top two layers of brick,install copper though-wall counter flashing, and copper step flashing,install mortar wash cap with embedded mesh. ![]() Permit type: Vcc general work | Permit status: Permit issued | Expiration date: January 21, 2016 | Current use: Single family | Permit id: 15-07229-Vcgen | |||||
Remove existing synthetic roofing material repair and/or replace underlayment as necessary install new natural slate (grey/green), using copper nails install/repair copper gutters, flashing and vents install/reinstall ceramic or concrete v-style or terra cotta ridge tiles metal cap-flashing on the parapets is not allowednote:trash chutes are required for removal of debris from all roofsall work must conform to standard vcc policies & guidelinespermit does not allow for cap flashing on parapet or surrounding wallstorch-applied roofing is not permitted in the vieux carr. ![]() Permit type: Vcc general work | Permit status: Permit issued | Expiration date: January 10, 2015 | Current use: Half of a party wall double | Permit id: 14-21349-Vcgen | |||||
Change the existing asphalt roof shingle and galvanized flashing to grey slate and copper flashing. Masonry work using vcc approved mortar will be done to facilitate the flashing work. ![]() ![]() Permit type: Renovation (non-structural) | Permit status: Application submitted | Current use: Single family | Permit id: 16-06630-Rnvn | |||||
SCORE 59 Interior demolition of interior walls,ceiling,and flooring-non structural. No use and occupancy,plans to follow. Extend permit 6 months to 12-15-16. Permit type: Interior demolition | Permit status: Permit issued | Expiration date: July 8, 2015 | Current use: Multi-family | Permit id: 15-00540-Demi | |||||
Side walk repair. ![]() Permit type: Sidewalk repair | Permit status: Permit issued | Expiration date: February 19, 2017 | Current use: Single family | Permit id: 16-24084-Rswr | |||||
Remove existing unpermitted asphalt shingle roofing material remove existing unpermitted galvanized flashingrepair and/or replace underlayment as necessaryinstall new natural slate (grey/green), using copper nailsinstall/repair half round copper gutters and flashinginstall/reinstall ceramic or concrete v-style or terra cotta ridge tiles. Replace broken tiles as needed, to match existing. Metal cap-flashing on the parapets is not allowedrepair/repoint masonry as needed, using bricks to match existing and vcc approved mortar forumla as follows:mortar: no more than 1 part portland cement, to 3 parts lime, 9 parts sand, and enough water to form a workable mix. Prepackaged mixes are not permitted. The resulting mortar should range in color from white to beige but should not be grey in color. Note: ratio of portland cement not to exceed 1:12. Note: trash chutes are required for removal of debris from all roofs all work must conform to standard vcc policies & guidelines permit does not allow f ![]() ![]() Permit type: Vcc general work | Permit status: Returned for revision | Expiration date: October 11, 2016 | Current use: Single family | Permit id: 16-06630-Vcgen | |||||
Following rehabilitation work to be completed per plans and materials stamped vcc approved 07/28/16, including:reinstall previously demolished balcony (approx. 3-2" deep), decorative ironwork railing to be permitted separately. Repoint masonry using vcc mortar forumla (attached), and install stucco using vcc stucco forumla (attached). All reinstalled masonry must be properly "toothed in" to existing masonry wall, using vcc mortar formula (attached). Cracked or broken bricks shall be replaced to match existing in color, size, material, porosity, detail, profile and exposure. Install new storage shed (approx 10-6" x 4-4") in rear courtyard, rebuild stair in rear loggia. Construct single fifteen (15)-lite over two(2)-panel wood door w/ five (5)-lite over single panel sidelites & fifteen (15)-lite transom to enclose rear loggia (first floor to remain under vcc jurisdiction). Install eleven (11) geothermal wells throughout courtyard, alley and loggia,install new doors, windows, transoms and s ![]() Permit type: Vcc general work | Permit status: Permit issued | Expiration date: January 28, 2017 | Current use: Single family | Permit id: 16-09663-Vcgen | |||||
SCORE 59 Renovate single-family dwelling as per plans Permit type: Renovation (non-structural) | Permit status: Permit issued | Expiration date: January 28, 2017 | Current use: Single family | Permit id: 16-09663-Rnvn | |||||
Extension of existing dumpster permit 16-24079 ![]() Permit type: Dumpster/construction zone | Permit status: Voided - duplicate permit | Completion date: November 30, 2016 | Current use: Half of a party wall double | Permit id: 16-39146-Rczd | |||||
Place dumpster in the parking lane in front of 916 governor nicholls st for days, from 07 28 2016 to 08 07 2016. Extending dumpster permit for 8 days from 08 07 2016 to 08 15 2016. Extending dumpster permit for days from 08 16 16 to 09 16 16. Extending dumpster permit for 13 days from 09 17 16 to 09 30 16. Extending dumpster permit for 31 days from 09 30 2016 to 10 31 2016. Extending dumpster permit for 31 days from 09 30 2016 to 10 31 2016. Extending dumpster permit for days from 11 1 2016 to 11 30 2016. Extending dumpster permit for 31 days from 11 30 2016 to 12 31 2016. ![]() Permit type: Dumpster/construction zone | Permit status: Dpw extension approval | Expiration date: May 17, 2017 | Current use: Single family | Permit id: 16-24079-Rczd | |||||
SCORE 96 Temp pole 16-09663-rnvn ![]() ![]() Permit type: Construction loop | Permit status: Permit issued | Completion date: December 21, 2016 | Expiration date: July 3, 2017 | Current use: Single family | Permit id: 16-40926-Loop | |||||
Following rehabilitation work to be completed per plans and materials stamped vcc approved 07 28 16, including:reinstall previously demolished balcony (approx. 3-2" deep), decorative ironwork railing to be permitted separately. Repoint masonry using vcc mortar forumla (attached), and install stucco using vcc stucco forumla (attached). All reinstalled masonry must be properly "toothed in" to existing masonry wall, using vcc mortar formula (attached). Cracked or broken bricks shall be replaced to match existing in color, size, material, porosity, detail, profile and exposure. Install new storage shed (approx 10-6" x 4-4") in rear courtyard, rebuild stair in rear loggia. Construct single fifteen (15)-lite over two(2)-panel wood door w five (5)-lite over single panel sidelites & fifteen (15)-lite transom to enclose rear loggia (first floor to remain under vcc jurisdiction). Install eleven (11) geothermal wells throughout courtyard, alley and loggia,install new doors, windows, transoms and s ![]() Permit type: Vcc general work | Permit status: Vcc arc meeting | Expiration date: January 28, 2017 | Current use: Single family | Permit id: 16-09663-Vcgen | |||||
Dumpster permit per sketch ![]() Permit type: Dumpster/construction zone | Permit status: Permit issued | Expiration date: July 12, 2017 | Current use: Single family | Permit id: 17-01232-Rczd | |||||
Install five geothermal units ![]() ![]() Permit type: Mechanical hvac | Permit status: Permit issued | Expiration date: April 13, 2017 | Current use: Single family | Permit id: 16-31862-Hvac | |||||
Street closure - pouring concrete for one (1) day, from 11 03 2016 to 11 03 2016, 6:00am to 6:00pm. ![]() Permit type: Dumpster/construction zone | Permit status: Permit issued | Expiration date: May 1, 2017 | Current use: Single family | Permit id: 16-36231-Rczd | |||||
SCORE 65 Reserve parking to park a concrete truck. Related permit is 16-09663-rnvn. 01-19-17 to 01 20 2117. ![]() ![]() Permit type: Dumpster/construction zone | Permit status: Permit issued | Expiration date: July 20, 2017 | Current use: Half of a party wall double | Permit id: 17-01676-Rczd | |||||
Following work to be completed per plans and materials stamped vcc approved 07 21 15, to include:removal of all c. 1930s masonry infill in main building and dependency, restoring openings to their original sizes,removal of masonry as indicated on plans, for carriageway entrance on gov. Nicholls elevation,bricking-in of non-original, c. 1930s openings. Restore decaying parapets by removing and resetting top two layers of brick,install copper though-wall counter flashing, and copper step flashing,install mortar wash cap with embedded mesh. ![]() Permit type: Vcc general work | Permit status: Permit issued | Expiration date: January 21, 2016 | Current use: Single family | Permit id: 15-07229-Vcgen | |||||
Remove existing unpermitted asphalt shingle roofing material remove existing unpermitted galvanized flashingrepair and or replace underlayment as necessaryinstall new natural slate (grey green), using copper nailsinstall repair half round copper gutters and flashinginstall reinstall ceramic or concrete v-style or terra cotta ridge tiles. Replace broken tiles as needed, to match existing. Metal cap-flashing on the parapets is not allowedrepair repoint masonry as needed, using bricks to match existing and vcc approved mortar forumla as follows:mortar: no more than 1 part portland cement, to 3 parts lime, 9 parts sand, and enough water to form a workable mix. Prepackaged mixes are not permitted. The resulting mortar should range in color from white to beige but should not be grey in color. Note: ratio of portland cement not to exceed 1:12. Note: trash chutes are required for removal of debris from all roofs all work must conform to standard vcc policies & guidelines permit does not allow f ![]() ![]() Permit type: Vcc general work | Permit status: Returned for revision | Expiration date: October 11, 2016 | Current use: Single family | Permit id: 16-06630-Vcgen | |||||
Following demolition work to be completed per plans and materials stamped vcc approved 06 16 15, to include:remove c. 1930s windows and doors in main building and dependencyremove second floor wood frame addition in courtyardremove dependency balcony ironwork railingremove masonry below dependency window openings as indicatedremove lattice ceiling in alley and loggiaremove all exterior utilitiesremove c. 1930s staircase in passageway ![]() ![]() Permit type: Renovation (structural) | Permit status: Application submitted | Current use: Single family | Permit id: 15-07229-Rnvs | |||||
Following demolition work to be completed per plans and materials stamped vcc approved 06 16 15 and 06 17 15, to include:remove c. 1930s windows and doors in main building and dependencyremove all plaster and furring on gov. Nicholls side courtyard wallremove second floor wood frame addition in courtyardremove brick infill of existing arch on second floor gov. Nicholls side courtyard wallremove c. 1930s staircase in dauphine side passageway. Install plywood barrier to prevent injury. Remove dependency balcony ironwork railing, metal decking, and plywood fasciaremove masonry below dependency window openings as indicatedremove lattice ceiling in alley and loggiaremove all exterior utilities, water heaters in stairwell, and roof ventsremove small patches of stucco from street facade to check condition of underlying brick. Site to be cleared and prepped after work is complete. All removed materials to be reused where possible. All unusable material to be disposed of off site. Note: this permi ![]() Permit type: Vcc general work | Permit status: Vcc arc meeting | Expiration date: December 16, 2015 | Current use: Single family | Permit id: 15-07229-Vcgen | |||||
Remove existing synthetic roofing material repair and or replace underlayment as necessary install new natural slate (grey green), using copper nails install repair copper gutters, flashing and vents install reinstall ceramic or concrete v-style or terra cotta ridge tiles metal cap-flashing on the parapets is not allowednote:trash chutes are required for removal of debris from all roofsall work must conform to standard vcc policies & guidelinespermit does not allow for cap flashing on parapet or surrounding wallstorch-applied roofing is not permitted in the vieux carr. ![]() Permit type: Vcc general work | Permit status: Permit issued | Expiration date: January 10, 2015 | Current use: Half of a party wall double | Permit id: 14-21349-Vcgen | |||||
To install 17 kw generator in rear courtyard as per architectural committee approval of 11 08 16 and plans & specs stamped vcc approved 05 05 17. Generator measures 50. 5 wide x 32. 9 deep x 31 tall. ![]() Permit type: Vcc general work | Permit status: Permit issued | Expiration date: November 5, 2017 | Current use: Half of a party wall double | Permit id: 17-15328-Vcgen | |||||
SCORE 96 Install new gas line, 2 gas water heater i, generator,3 gas lights, 3 fireplace- log lights and meter increase.[ # 8046 8103 ] ![]() ![]() Permit type: Mechanical fuel gas | Permit status: Permit issued | Expiration date: November 18, 2017 | Current use: Single family | Permit id: 17-16388-Fgas | |||||
SCORE 59 Install a 17kw briggs and stratton generator as per sketch and vcc approval. (916 & 916 d gov nicholls st) generator for 916 side. ![]() ![]() Permit type: Renovation (non-structural) | Permit status: Permit issued | Expiration date: November 5, 2017 | Current use: Single family | Permit id: 17-15328-Rnvn | |||||
SCORE 89 Remove/replace a new roof as per vcc ?????. Permit type: Renovation (non-structural) | Permit status: Application review | Current use: Half of a party wall double | Permit id: 14-21009-Rnvn | |||||
SCORE 93 Interior exploratory, non structural demolition. Removal of fixtures, plumbing. Casework, exploratory 5 ft of wall finishes. Ceiling and floor. No use and occupancy, renovation plans to follow. Permit type: Interior demolition | Permit status: Permit issued | Expiration date: September 14, 2017 | Current use: Half of a party wall double | Permit id: 17-08681-Demi | |||||
Side walk repair. Permit is extended as per dpw approval ![]() Permit type: Sidewalk repair | Permit status: Permit issued | Expiration date: May 10, 2017 | Current use: Single family | Permit id: 16-36227-Rswr | |||||
This permit allows for the temporary closure of the 9 block governor nicholls between burgundy and dauphine for four hours on 09 08 2017. ![]() Permit type: Dumpster/construction zone | Permit status: Permit issued | Expiration date: March 5, 2018 | Current use: Business use | Permit id: 17-30250-Rczd | |||||
SCORE 65 Reserve parking to park a dumpster. Related permit is 16-09663-rnvn. 03-09-17 to 04-23-17. Permit extended to 06 07 2017. Permit extended again from 06 08 17 until 07 22 17. Permit is extended for an additional 45 days to 09 06 2017. Permit is extended for 45 days to 10 22 2017. ![]() ![]() Permit type: Dumpster/construction zone | Permit status: Dpw extension approval | Expiration date: January 24, 2018 | Current use: Single family | Permit id: 17-08037-Rczd | |||||
To install two (5) dome 4mp dome4mm fixed ip cameras per cut sheet and drawings submitted 09 25 17 & stamped vcc approved 11 08 17. Cameras shall be painted to match the adjacent building surface. All wiring shall be placed in conduitsall conduits to be placed along the inside corners of building surfaces as much as possible, such as along gallery balcony purlins at the deck line, and painted to match the adjacent surfaces. All cameras to be installed a minimum of 9-feet above the sidewalk and a maximum of 18-inches below the bottom of the balcony, gallery, porch ceiling, roof overhang, or soffit. ![]() Permit type: Vcc general work | Permit status: Permit issued | Expiration date: May 8, 2018 | Current use: Single family | Permit id: 17-31087-Vcgen | |||||
Install security cameras ![]() Permit type: Renovation (non-structural) | Permit status: Application submitted | Current use: Single family | Permit id: 17-31087-Rnvn | |||||
SCORE 65 In front of 916 gov. Nicholls, permit allows for (1) the reserving of the parking lane for service vehicles and for (2) the placement of a port-o-let on the sidewalk, provided that a minimun width of 4 feet pedestrain passage is maintained. These allowances are for 1 year 07/18/2016 to 07/18/2017. Related renovation permit #16-09663-rnvn ![]() ![]() Permit type: Dumpster/construction zone | Permit status: Permit issued | Expiration date: January 18, 2017 | Current use: Half of a party wall double | Permit id: 16-23485-Rczd |