Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Zoning/use permit ![]() Permit status: Completed | Permit id: 479510 | |||||
Administrative permit ![]() Permit status: Completed | Permit id: 549428 | |||||
Addition permit ![]() Permit status: Completed | Permit id: 481103 | |||||
Mechanical permit ![]() Permit status: Completed | Permit id: 532963 | |||||
Suppression permit ![]() Permit status: Completed | Permit id: 540624 | |||||
Plumbing permit ![]() Permit status: Completed | Permit id: 532304 | |||||
Use permit ![]() Permit status: Completed | Permit id: 612951 | |||||
Electrical permit ![]() Permit status: Completed | Permit id: 539783 | |||||
On 11/24/2014, the department of licenses and inspections issued a notice of refusal for application #549428. ![]() Applicant: Rotciver Lebron-Martinez | Permit type: Appeal | Permit status: Approved | Completion date: January 9, 2015 | Permit id: 24210 | |||||
On 9/19/2016, the department of licenses and inspections issued a notice of refusal for application #707972. ![]() Applicant: Michelle Kleschick | Permit type: Appeal | Permit status: Approved | Permit id: 28919 | |||||
On 8/28/13 department of licenses and inspections issued notice of refusal for application #481103. ![]() Applicant: Harman Deutsch Architure | Permit type: Appeal | Permit status: Approved | Permit id: 21249 | |||||
Zoning use permit ![]() Client Company: Attn: Tony Ren | Permit status: Completed | Permit id: 479510 | |||||
On 11 24 2014, the department of licenses and inspections issued a notice of refusal for application #549428. ![]() Client Company: Attn: Tony Ren | Applicant: Rotciver Lebron-Martinez | Permit type: Appeal | Permit status: Approved | Completion date: January 9, 2015 | Permit id: 24210 | |||||
On 9 19 2016, the department of licenses and inspections issued a notice of refusal for application #707972. ![]() Client Company: Attn: Tony Ren | Applicant: Michelle Kleschick | Permit type: Appeal | Permit status: Approved | Completion date: December 19, 2016 | Permit id: 28919 | |||||
On 8 28 13 department of licenses and inspections issued notice of refusal for application #481103. ![]() Client Company: Attn: Tony Ren | Applicant: Harman Deutsch Architure | Permit type: Appeal | Permit status: Approved | Permit id: 21249 | |||||
At 9 cherry st erect a 4 story addition to an existing 5 story structure with 56 residential total ( 28 existing units + 28 proposed units & 1 existing food processing of chicken, meat, wholesale and distribution, as per plans. At 908 (parcel "a") cherry parcel "a" to erect a 5 story structure with 1 vacant commercial unit and 9 apt units with balconies. Parcel "b" to be the same as parcel "a". ![]() Permit type: Zoning/use permit | Permit status: Completed | Completion date: June 27, 2013 | Permit id: 479510 | |||||
SCORE 93 For the erection of a three (3) story vertical addition with roof access structure for use as twenty one (21) dwelling units. Interior alterations to include creation of a fitness center, trash room, and fire command center on the 1st floor and for the reconfiguration of the exit stairways and for the addition of one (1) elevator, for a total of two (2) elevators, from the cellar to the roof. The three (3) story addition to be interconnected with an existing five (5) story structure with twenty eight (28) existing dwelling units. For a total of forty nine (49) dwelling units. See application 413958 for certificate of occupancy for the existing five (5) story structure. See bbs variance no. 21249 for sprinkler head location separate permit required for mechanical, electrical, plumbing, fire supression. ![]() ![]() Permit type: Addition permit | Permit status: Completed | Completion date: December 18, 2015 | Permit id: 481103 | |||||
SCORE 100 Install 3 heatpumps and 5 ton,with related duct one ductless system with 4 heads in basement ![]() ![]() Permit type: Mechanical permit | Permit status: Active | Completion date: October 2, 2017 | Permit id: 768230 | |||||
Use registration for eat-in restaurant at 1st fl and basement all other uses as previously approved ![]() Permit type: Use permit | Permit status: Completed | Completion date: May 27, 2015 | Permit id: 612951 | |||||
Amending building permit#481103 to include interior alterations, infill floor framing, and creation of exterior wall openings in the west exterior wall located on the property line at the 4th-8th floor, and all other work as per approved plans. Separate permit required for mechanical, electrical, plumbing and fire suppression work all work shall be done in accordance with bbs variance case no. 24210 see ap #481103 for certificate of occupancy. ![]() Permit type: Administrative permit | Permit status: Completed | Completion date: September 23, 2015 | Permit id: 549428 | |||||
SCORE 100 To rough in and install detail piping for all pipes and fixtures. Fixtures are furnish by owner (multi family) ![]() ![]() Permit type: Plumbing permit | Permit status: Completed | Completion date: December 4, 2015 | Permit id: 532304 | |||||
SCORE 100 Installation of forty-two (42) one and one-half (1. 5) ton, six (6) two (2) ton and one (1) two and one-half ton heat pumps with associated ductwork, refrigerant piping in new shaft enclosures, grilles, registers and diffusers throughout dwelling units; installation of rooftop unit to serve common areas and stair pressurization system at exit enclosures throughout an eight (8) story structure per plans. Separate permits required for all electrical and plumbing work. Clothes dryer exhausts and unit heaters not included as part of this approval ![]() ![]() Permit type: Mechanical permit | Permit status: Completed | Completion date: December 4, 2015 | Permit id: 532963 | |||||
SCORE 100 For the installation of a new sprinkler system to include installation of two (2) new, interconnected 4-in diameter class i wet standpipes, new fire pumps and jockey pumps, and new 6-in diameter backflow preventer, in accordance with nfpa 2007, standard 13 and 14, with a 6-in diameter service line. ![]() ![]() Permit type: Suppression permit | Permit status: Completed | Completion date: December 31, 2015 | Permit id: 540624 | |||||
SCORE 100 Install fire alarm, install 30 amp service & complete fit out of apt, (1st floor commerical space excluded) as per nec 2008 & nfpa 72 (mixed use) ![]() ![]() Permit type: Electrical permit | Permit status: Completed | Completion date: December 23, 2015 | Permit id: 539783 | |||||
Alteration permit ![]() Permit status: Expired | Permit id: 655687 | |||||
Use permit ![]() Permit status: Completed | Permit id: 700456 | |||||
Use permit ![]() Permit status: Completed | Permit id: 700456 | |||||
Alteration permit ![]() Permit status: Expired | Permit id: 655687 | |||||
Use to adult daycare center at 1st floor and basement. ![]() Permit type: Use permit | Permit status: Completed | Completion date: June 16, 2016 | Permit id: 700456 | |||||
For level ii alterations to an existing space for the use of an adult day care at the basement and first floor level with no overnight stay. Alterations to include the erection of partition walls, provide finishes and furnishings throughout. Building is fully sprinklered. Application grant by board of building standard under case number 28919 with the following proviso: additional hand held shower in each accessible stall in two gang toilet rooms on the upper floor. All work to be done per approved plans. ![]() Permit type: Alteration permit | Permit status: Active | Completion date: June 13, 2017 | Permit id: 707972 | |||||
SCORE 100 Ez permit sprinkler relocation (residential)- for the relocation of residential sprinkler heads as per attached standard. Deviations from this standard will result in permit revocation and require submission of construction plans. ![]() ![]() Permit type: Suppression permit | Permit status: Active | Completion date: November 7, 2017 | Permit id: 778107 | |||||
1st floor and basement interior renovations for restaurant with private dining rooms. ![]() Permit type: Alteration permit | Permit status: Expired | Completion date: July 26, 2016 | Permit id: 655687 |