Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Relocate ac condensor from front to rear roof per vcc. Date: April 20, 2015 Value: $3,000 Permit type: Renovation (non-structural) | Permit status: Permit approved | Current use: Single family | Permit id: 15-11810-Rnvn | |||||
Shutters.... Thyme green ppg 1128-6porch deck.... Blue dolphin ppg 1041-4 Date: April 28, 2014 Permit type: Vcc paint | Permit status: Permit issued | Expiration date: October 29, 2014 | Current use: Half of a party wall double | Permit id: 14-13313-Vcpnt | |||||
SCORE 83 Interior sheetrock repair. Permit type: Renovation (non-structural) | Permit status: Permit issued | Expiration date: January 1, 2015 | Current use: Half of a party wall double | Permit id: 14-20466-Rnvn | |||||
Retain one (1) existing hvac condenser unit, located on front roof slope of main building (bourbon street side of dormer), installed prior to vcc notice of violation, sent september 17, 2001. Note: this permit does not include the retention of any unpermitted cap flashing or additional unpermitted mechanical equipment. Date: April 30, 2015 Permit type: Vcc general work | Permit status: Permit issued | Expiration date: August 29, 2016 | Current use: Single family | Permit id: 15-11810-Vcgen | |||||
SCORE 62 New matching 4" copper downspout, repair and re-point the brick at that area and repair or replace portions of the wood door casing if necessary with matching. Permit type: Renovation (non-structural) | Permit status: Zoning review | Current use: Single unit in multi-family dwelling | Permit id: 16-27716-Rnvn | |||||
Repair replace portions of copper downspout on bourbon-side of ursulines elevation, as necessary, to match existing in size. Location and path. Repoint masonry around downspout wall penetration as needed, using vcc mortar formula (attached). Any reinstalled masonry must be properly "toothed in" to existing masonry wall, using vcc mortar formula (attached). Cracked or broken bricks shall be replaced to match existing in color, size, material, porosity, detail, profile and exposure. Repair stucco as needed around downspout wall penetrations, using vcc stucco forumla (attached). Paint to match adjacent surfacesfailure to exactly match materials, paint color, or vcc mortar as specified in permit will result in a vcc violation and mandated repair of improper work. All mortar to be mixed using the vcc formula (attached) with a maximum of 1 part portland cement, to 3 parts lime, to 9 parts sand, and enough water to form a workable mix. Prepackaged mixes are not permitted. Date: September 6, 2016 Permit type: Vcc general work | Permit status: Permit approved | Current use: Single unit in multi-family dwelling | Permit id: 16-27716-Vcgen | |||||
Retain existing cap flashing Date: May 9, 2017 Value: $100 Permit type: Renovation (structural) | Permit status: Plan review | Current use: Multi-family | Permit id: 17-16236-Rnvs | |||||
Retain existing cap flashingnote: neigboring property (725 ursulines) responsible for cap flashing. Application for 723 ursulines closed. Date: May 10, 2017 Permit type: Vcc general work | Permit status: Permit not required | Completion date: July 20, 2017 | Current use: Multi-family | Permit id: 17-16236-Vcgen | |||||
SCORE 62 Construct 2 painted wood louver hvac screens; retain existing roof cap flashing Permit type: Renovation (non-structural) | Permit status: Plan review | Current use: Multi-family | Permit id: 17-10853-Rnvn | |||||
To retain relocate mechanical units and construct wood enclosure as per architectural committee approval of 06 14 16, final materials submitted 03 30 17 and stamped vcc approved 04 04 17. Work includes but is not limited to: relocate a c unit c to new metal rack with wood screening located in garden bed between the main building and slave quarter construct a wood enclosure around existing metal rack housing units a and b all wood of enclosure to be painted to match the shutters of the slave quarter buildingdark green, semigloss note: this permit does not allow for the retention of cap flashing. A separate application will be needed if the applicant seeks retention of this element. 1. Courtyard hvac mini-split screens addressing vcc comments dated 1 12 16 and 6 14 16request for construction of two painted wood hvac screens with staggered wood louvres and operable latched access doors. Both would be located within existing planting beds. One enclosure would house units a and b and be con Date: March 31, 2017 Permit type: Vcc general work | Permit status: Permit issued | Expiration date: October 4, 2017 | Current use: Multi-family | Permit id: 17-10853-Vcgen |