Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Alteration permit ![]() Client: Lin Li Ping | Permit status: Active | Permit id: 732175 | |||||
Plumbing permit ![]() Client: Benton Sharon T | Permit status: Completed | Permit id: 333415 | |||||
Mechanical permit ![]() Client: Lin Li Ping | Permit status: Active | Permit id: 742185 | |||||
Plumbing permit ![]() Client: Weinberg Elijah J Townes Tikki S | Permit status: Completed | Permit id: 393545 | |||||
Suppression permit ![]() Client: Lin Li Ping | Permit status: Active | Permit id: 752416 | |||||
Electrical permit ![]() Client: Benton Sharon T | Permit status: Completed | Permit id: 331967 | |||||
Electrical permit ![]() Client: Lin Li Ping | Permit status: Active | Permit id: 742555 | |||||
Plumbing permit ![]() Client: Lin Li Ping | Permit status: Active | Permit id: 737933 | |||||
SCORE 99 Ez standard kitchen fire suppression- for the installation of new wet chemical kitchen hood fire suppression system as per attached standard. Deviations from this standard will result in permit revocation and require submission of construction plans. ![]() ![]() Client: Lin Li Ping | Permit type: Suppression permit | Permit status: Completed | Completion date: September 5, 2017 | Permit id: 752416 | |||||
SCORE 100 Install 13 2x 4 florecent ceiling light fixtures, 3 emergency light, two gfis, 15 reecepticles, one exhaust and one make-up air fan in kitchen , 7 light switches, six smoke detectors, four horn strope, one strobe, as per 2008 nec. ![]() ![]() Client: Lin Li Ping | Permit type: Electrical permit | Permit status: Completed | Completion date: September 5, 2017 | Permit id: 760174 | |||||
SCORE 93 Alteration: interior plumbing for the fit-out of an existing(bar restaurant). The installation shall comply with the philadelphia plumbing code, 2004. Additional permits are required for the 5" sewer lateral and the 2" domestic water distribution service to the street mains, as well as the required 2" backflow prevention containment assembly on the main domestic water supply. Water heater shall comply with code section 607. 3. 2 of the international plumbing code, 2009, for thermal expansion protection (i. E. Expansion tank). Individual isolation backflow preventers are required: wok sinks, water filters, beverage dispensers, ice makers, ice bins, dishwashers, etc., per code section(s) p-806. 1. 1 & table p-904. 7 of the philadelphia plumbing code, 2004 and code section(s) 608. 3 & table 608. 1 of the international plumbing code, 2009. Grease interceptors must comply with code section(s) p-508 & p-5 and per the requirements of the industrial waste division of the philadelphia water department, s ![]() ![]() Client: Lin Li Ping | Permit type: Plumbing permit | Permit status: Completed | Completion date: September 5, 2017 | Permit id: 759873 | |||||
SCORE 89 Install (1) 4 tons 92% 100k btu gas furnace. Install all ductwork without penetrating the fire wall. ![]() ![]() Client: Lin Li Ping | Permit type: Mechanical permit | Permit status: Completed | Completion date: September 5, 2017 | Permit id: 742185 | |||||
SCORE 99 No change in use and occupancy classification. Level ii interior alterations as per approved plans. Separeate permit required for any mep work. ![]() ![]() Client: Lin Li Ping | Permit type: Alteration permit | Permit status: Completed | Completion date: September 5, 2017 | Permit id: 732175 | |||||
SCORE 93 Plumbing for 3pc bath, 1 kitchen sink hot abd cold water ![]() ![]() Client: Lin Li Ping | Permit type: Plumbing permit | Permit status: Completed | Completion date: September 5, 2017 | Permit id: 737933 | |||||
SCORE 99 Installation of one (1) commercial kitchen hood with associated ductwork and exhaust fan as per approved plans. Separate fire suppression permit required. ![]() ![]() Client: Lin Li Ping | Permit type: Mechanical permit | Permit status: Completed | Completion date: September 5, 2017 | Permit id: 738413 | |||||
SCORE 100 Install 10-receptacles & 10-lights fixtures as per nec 2008 west district ![]() ![]() Client: Lin Li Ping | Permit type: Electrical permit | Permit status: Expired | Completion date: February 16, 2017 | Permit id: 742555 | |||||
SCORE 100 Curb trap(sfd) ![]() ![]() Client: Weinberg Elijah J Townes Tikki S | Permit type: Plumbing permit | Permit status: Completed | Completion date: April 13, 2012 | Permit id: 393545 | |||||
SCORE 100 5x4 curb trap ![]() ![]() Client: Benton Sharon T | Permit type: Plumbing permit | Permit status: Completed | Completion date: April 20, 2011 | Permit id: 333415 | |||||
SCORE 100 1 amp service- 32 space. Replace (6) outlets and (6) switches, a light, (2) 15amp circuits. In accordance with 2008 nec for a single family dwelling (paid for by phdc) ![]() ![]() Client: Benton Sharon T | Permit type: Electrical permit | Permit status: Completed | Completion date: May 2, 2011 | Permit id: 331967 |