Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Repair broken shutters on front balconymake minor repairs to shutters on second floor of chartres elevation as necessary. Any replacement material shall match existing in color, size, material, detail, profile and exposure. Touch up paint as necessary to match existing... Light green, semigloss Date: January 14, 2015 Permit type: Vcc general work | Permit status: Permit issued | Expiration date: July 14, 2015 | Current use: Mixed use | Permit id: 15-00769-Vcgen | |||||
SCORE 56 Repair broken shutters on front balcony Permit type: Accessory structure | Permit status: Plan review | Current use: Mixed use | Permit id: 15-00769-Accs | |||||
SCORE 62 Doors and balcony railings and supports: french quarter green, (to match existing), semigloss Date: May 26, 2016 Contractor: Keith Francois Permit type: Vcc paint | Permit status: Permit issued | Expiration date: December 3, 2016 | Current use: Mixed use | Permit id: 16-17745-Vcpnt | |||||
To make roof repairs per materials submitted 04/23/14 & stamped approved 04/24/14, including the removal of an existing skylight and roofing over to match existing adjacent roofing surface, flashings, repair/replacement of gutters, leader heads, and down spouts to match existing, removal of vegetation from masonry, and masonry repairs with vcc approved mortar mix below. Mortar: no more than 1 part portland cement, 3 parts lime, 9 parts sand, and enough water to form a workable mix. Prepackaged mixes are not permitted, as quality control is not consistent. Date: April 23, 2014 Permit type: Vcc general work | Permit status: Permit issued | Expiration date: October 24, 2014 | Current use: Business use | Permit id: 14-12799-Vcgen | |||||
Historical import type: enforcement vcc permit generaluser: cabergtracking: 86116720942status: permit issuedstatus date: 2/10/2012 12:00: amowner: clibe, llcowner address: et al 123 walnut bl, new orleans, la 70118owner edited by: 2/10/2012 by caberg Date: February 10, 2012 Permit type: Vcc general work | Permit status: Staff action - issue perm | Current use: Unknown | Permit id: Vccp-12-0134 | |||||
Repaint carriageway doors - doors and windowscoach house green, senour, semigloss Date: February 18, 2014 Permit type: Vcc paint | Permit status: Permit finaled | Completion date: December 17, 2014 | Expiration date: August 27, 2014 | Current use: Business use | Permit id: 14-06529-Vcpnt | |||||
Historical import type: enforcement vcc permit paintuser: tmcleodtracking: 8617230318status: permit issuedstatus date: 4/26/2012 12:00: amowner: clibe, llcowner address: et al 123 walnut bl, new orleans, la 70118owner edited by: 4/26/2012 by tmcleod Date: April 26, 2012 Permit type: Vcc paint | Permit status: Staff action - issue perm | Current use: Unknown | Permit id: Vccp-12-0387 | |||||
Historical import type: enforcement vcc permit generaluser: cabergtracking: 86116720942status: permit issuedstatus date: 2 10 2012 12:00: amowner: clibe, llcowner address: et al 123 walnut bl, new orleans, la 70118owner edited by: 2 10 2012 by caberg Date: February 10, 2012 Permit type: Vcc general work | Permit status: Staff action - issue perm | Current use: Unknown | Permit id: Vccp-12-0134 | |||||
To replace a 12 section of fascia board damaged by vehicle to match previously existingto prime paint board to match existing color and finish (white, semigloss) all repair replacement work shall match existing in color, size, material, detail, profile and exposure. Failure to exactly match materials, details, profiles, exposures, or vcc mortar as specified in permit will result in a vcc violation and mandated repair of improper work. Date: January 12, 2017 Permit type: Vcc general work | Permit status: Permit issued | Expiration date: July 12, 2017 | Current use: Business use | Permit id: 17-01244-Vcgen | |||||
To make roof repairs per materials submitted 04 23 14 & stamped approved 04 24 14, including the removal of an existing skylight and roofing over to match existing adjacent roofing surface, flashings, repair replacement of gutters, leader heads, and down spouts to match existing, removal of vegetation from masonry, and masonry repairs with vcc approved mortar mix below. Mortar: no more than 1 part portland cement, 3 parts lime, 9 parts sand, and enough water to form a workable mix. Prepackaged mixes are not permitted, as quality control is not consistent. Date: April 23, 2014 Permit type: Vcc general work | Permit status: Permit issued | Expiration date: October 24, 2014 | Current use: Business use | Permit id: 14-12799-Vcgen | |||||
Historical import type: enforcement vcc permit paintuser: tmcleodtracking: 8617230318status: permit issuedstatus date: 4 26 2012 12:00: amowner: clibe, llcowner address: et al 123 walnut bl, new orleans, la 70118owner edited by: 4 26 2012 by tmcleod Date: April 26, 2012 Permit type: Vcc paint | Permit status: Staff action - issue perm | Current use: Unknown | Permit id: Vccp-12-0387 | |||||
SCORE 92 The restoration of one set of french doors located on the front facade, second floor. The doors will be de-glazed, re-glazed, and have a repair to the bottom where the panel is completely rotten. The doors will also be reinstalled with no changes in appearance including paint color. Permit type: Renovation (non-structural) | Permit status: Application submitted | Current use: Multi-family | Permit id: 17-38854-Rnvn | |||||
Remove vegitation where necessaryrepoint and restucco masonry on second floor chartres street elevation using vcc approved mortar and stucco (see attatched)repaint to match existingall reinstalled masonry must be properly "toothed in" to existing masonry wall, using vcc mortar formula (attached). Cracked or broken bricks shall be replaced to match existing in color, size, material, porosity, detail, profile and exposure. Failure to exactly match materials, paint color, or vcc mortar as specified in permit will result in a vcc violation and mandated repair of improper work. All mortar to be mixed using the vcc recipe (attached) with a maximum of 1 part portland cement, to 3 parts lime, to 9 parts sand, and enough water to form a workable mix. Prepackaged mixes are not permitted. Date: November 9, 2017 Permit type: Vcc general work | Permit status: Permit issued | Expiration date: May 15, 2018 | Current use: Mixed use | Permit id: 17-37727-Vcgen | |||||
SCORE 61 Remove plant growth & make masonry paint repairs to 2nd flr front faade - repaint to match existing Date: November 5, 2017 Value: $9,631 Permit type: Renovation (non-structural) | Permit status: Zoning review | Current use: Mixed use | Permit id: 17-37727-Rnvn | |||||
Remove deteriorated floor boards, stringers, and fascia boards. Install new 3"x4" beaded stringers, 5/4x4 s2s t&g floorboards, and 7/8" fascia with " bead, all as per vcc standard detail sheet no. 12 (attached). All repair/replacement work shall match existing in color, size, material, detail, profile and exposure install four (4) remcraft 1 series surface-mounted down-light fixtures under chartres elevation balcony, centered above each ground-floor opening, halfway between building face and fascia edge, lamped with warm, white led lights of approximately 7 watts. All wiring and conduit is to be placed along the inside edges of the building, such as against gallery purlins, and painted to match adjacent building surfaces. Note: permit issued in response to violations. Work shall commence no less than days after permit is issued. Work must be completed no less than days after work begins. Owner will call vcc for final inspection upon completion of work. Date: August 12, 2014 Permit type: Vcc general work | Permit status: Permit finaled | Completion date: December 17, 2014 | Expiration date: February 18, 2015 | Current use: Business use | Permit id: 14-25711-Vcgen | |||||
Install one double-sided, wooden sign 3" thick, measuring 30" x 23" per application and rendering received and stamped vcc approved on 1/10/13. Sign will hang from underside of balcony on 4" chains and will be illuminated by existing floodlights. Sign will read "jose balli jewelry", and will be burgundy and white, with 8" letters, as shown in rendering received and stamped vcc approved 1/10/13. Date: January 10, 2013 Value: $1,500 Permit type: Vcc sign | Permit status: Permit finaled | Completion date: December 17, 2014 | Expiration date: July 10, 2013 | Current use: Mixed use | Permit id: 13-01064-Vcsgn | |||||
Fabricate and replace one set of french doors in opening on downriver side of chartres st. Facade, per application submitted 12/21/12 and drawings submitted on 12/21/12 and 1/16/13. Doors will be made of spanish cedar, and will match existing doors exactly, mounted on interior edge of jamb, opening inward. Doors will be glazed with safety glass, with no logo on glass. Date: January 16, 2013 Value: $3,500 Permit type: Vcc general work | Permit status: Permit finaled | Completion date: December 17, 2014 | Expiration date: July 16, 2013 | Current use: Mixed use | Permit id: 13-01582-Vcgen | |||||
Install one double-sided, wooden sign 3" thick, measuring 30" x 23" per application and rendering received and stamped vcc approved on 1 10 13. Sign will hang from underside of balcony on 4" chains and will be illuminated by existing floodlights. Sign will read "jose balli jewelry", and will be burgundy and white, with 8" letters, as shown in rendering received and stamped vcc approved 1 10 13. Date: January 10, 2013 Value: $1,500 Permit type: Vcc sign | Permit status: Permit finaled | Completion date: December 17, 2014 | Expiration date: July 10, 2013 | Current use: Mixed use | Permit id: 13-01064-Vcsgn | |||||
Fabricate and replace one set of french doors in opening on downriver side of chartres st. Facade, per application submitted 12 21 12 and drawings submitted on 12 21 12 and 1 16 13. Doors will be made of spanish cedar, and will match existing doors exactly, mounted on interior edge of jamb, opening inward. Doors will be glazed with safety glass, with no logo on glass. Date: January 16, 2013 Value: $3,500 Permit type: Vcc general work | Permit status: Permit finaled | Completion date: December 17, 2014 | Expiration date: July 16, 2013 | Current use: Mixed use | Permit id: 13-01582-Vcgen | |||||
Remove deteriorated floor boards, stringers, and fascia boards. Install new 3"x4" beaded stringers, 5 4x4 s2s t&g floorboards, and 7 8" fascia with " bead, all as per vcc standard detail sheet no. 12 (attached). All repair replacement work shall match existing in color, size, material, detail, profile and exposure install four (4) remcraft 1 series surface-mounted down-light fixtures under chartres elevation balcony, centered above each ground-floor opening, halfway between building face and fascia edge, lamped with warm, white led lights of approximately 7 watts. All wiring and conduit is to be placed along the inside edges of the building, such as against gallery purlins, and painted to match adjacent building surfaces. Note: permit issued in response to violations. Work shall commence no less than days after permit is issued. Work must be completed no less than days after work begins. Owner will call vcc for final inspection upon completion of work. Date: August 12, 2014 Permit type: Vcc general work | Permit status: Permit finaled | Completion date: December 17, 2014 | Expiration date: February 18, 2015 | Current use: Business use | Permit id: 14-25711-Vcgen |