SCORE 59 Crane placement Date: October 14, 2015 Contractor: Bobuco Inc Permit type: Dumpster/construction zone | Permit status: Permit issued | Expiration date: April 21, 2016 | Current use: Not applicable - oversize load transport | Permit id: 15-30965-Rczd | |||||
To carefully remove stair penthouse on chartres side of building & unpermitted mortar cap applied to rear property line wall, and to reconstruct stair penthouse and apply mortar cap using vcc approved mortar & stucco formula (below), replacing damaged bricks as necessary with like, soft red bricks, per brick sample submitted to vcc staff for review, per ac approval of 08/12/14, per survey submitted 07/29/14, per french market corporation authorization submitted 08/01/14, per structural engineers letter submitted 08/11/14, and per revised plans submitted 08/18/14, all stamped vcc approved 08/19/14. 1. Mortar: no more than 1 part portland cement, 3 parts lime, 9 parts sand, and enough water to form a workable mix. Prepackaged mixes are not permitted, as quality control is not consistent. Stucco: base coat consists of 2 coats, doubled up work of 5/8" total thickness. Proportioned as follows: no greater than 1:12 part portland cement, to 3 parts lime, and 9 parts sand, 6 lbs./cubic yard ha Date: July 15, 2014 Permit type: Vcc general work | Permit status: Permit issued | Expiration date: February 19, 2015 | Current use: Business use | Permit id: 14-25780-Vcgen | |||||
519 wilkinson: ground-floor stucco walls..."cathedral gray", flat or satin finish exposed masonry walls.... To remain unpainted wooden elements including doors, windows, frames, shop windows (except ground-floor), fascia/soffit/outriggers ofblacony..., "shoji white" sw7042, semigloss shutters"isle of pines" sw6461,semigloss ironwork, gutter downspouts, tie-plates, ground-floor trim and millwork ..."urbane bronze" sw7048535 wilkinson: stucco walls..."shoji white" sw7042, semigloss wooden elements including doors, windows, frames, shop windows,ironwork, gutter downspouts, tie-plates..., "urbane bronze" sw7048, semiglossnote: no other work is approved under this permit. Verbal stop work order remains in effect on fourth-story penthouse. No painting or other work is currently approved for this level. Seperate application must be submitted for review and approval and shall be permitted seperately. Date: May 12, 2014 Permit type: Vcc paint | Permit status: Permit issued | Expiration date: December 13, 2014 | Current use: Business use | Permit id: 14-17850-Vcpnt | |||||
Crane placement Date: November 4, 2015 Permit type: Dumpster/construction zone | Permit status: Permit issued | Expiration date: May 5, 2016 | Current use: Not applicable - oversize load transport | Permit id: 15-33390-Rczd | |||||
SCORE 98 Moving equipment Date: January 12, 2015 Contractor: Thyssenkrupp Permit status: Permit issued | Expiration date: July 12, 2015 | Current use: Business use | Permit id: 15-00891-Movg | |||||
Crane placement - from 9: am until 3: pm Date: February 12, 2016 Permit type: Dumpster/construction zone | Permit status: Permit issued | Expiration date: August 12, 2016 | Current use: Not applicable - oversize load transport | Permit id: 16-04463-Rczd | |||||
SCORE 98 13-14874-rnvs Date: May 11, 2015 Contractor: Lawrence Margiotta Permit type: Electrical service / circuit / feeder | Permit status: Permit issued | Expiration date: November 29, 2015 | Current use: Business use | Permit id: 15-14249-Serv | |||||
Crane placement. We would like to begin at 9: am and work until 3: pm. Date: August 8, 2016 Permit type: Dumpster/construction zone | Permit status: Permit issued | Expiration date: February 15, 2017 | Current use: Not applicable - oversize load transport | Permit id: 16-25789-Rczd | |||||
The following is approved in order to protect & preserve the permitted renovation work at 519-33 wilkinson street per vccs architectural committee approval of 09/27/11, vcc approval of 10/18/11, & plans submitted 07/31/12 & stamped vcc approved 08/07/12:1) installation of plate glass walls and doors in the fourth floor penthouse addition 2) installation of the base ply of the 2-ply modified bitumen roofing membrane system on the terraces3) repair and repointing to the masonry walls on both chartres and wilkinson elevations as needed using the vcc approved mortar formula (below)mortar: no more than 1 part portland cement, 3 parts lime, 9 parts sand, and enough water to form a workable mix. Prepackaged mixes are not permitted, as quality control is not consistent (i. E. No quikrete is allowed). Note: no other work is approved under this permit. The verbal stop work order (swo) issued 02/13/14 pertaining to the interior and exterior of the fourth-floor penthouse addition for work performed Date: May 6, 2014 Permit type: Vcc general work | Permit status: Permit issued | Expiration date: November 6, 2014 | Current use: Business use | Permit id: 14-14322-Vcgen | |||||
To reconstruct stair penthouse on chartres side of building as per vcc approved drawings. Date: August 18, 2014 Value: $35,000 Permit type: Renovation (structural) | Permit status: Permit issued | Expiration date: February 22, 2015 | Current use: Business use | Permit id: 14-25779-Rnvs | |||||
Elevator Date: February 12, 2015 Permit type: Electrical repair / replacement / addition | Permit status: Application submitted | Current use: Business use | Permit id: 15-04603-Erpr | |||||
Interior demolition of vacant commercial building. No use and occupancy under this permit. No exterior work under this permit. Plans to follow. Date: April 10, 2013 Value: $40,000 Permit type: Interior demolition | Permit status: Permit issued | Expiration date: October 10, 2013 | Current use: Business use | Permit id: 13-11179-Demi | |||||
Convert vacant warehouse building into a mixed use structure as per plans and 12-21487-vcgen:1st floor: 3 commercial spaces - 1) 2588 sq ft; 2) 2976 sq ft; 3) 2148 sq ft2nd & 3rd floor: 8 apartments each floor [apt 2a - 2h; apt 3a-3h]construct 4th floor addition: 4 apartments [apt 4a-4d]as per plans and bza 029-11. Date: May 13, 2013 Value: $2,000,000 Permit type: Renovation (structural) | Permit status: Permit issued | Expiration date: January 23, 2014 | Current use: Business use | Permit id: 13-14874-Rnvs | |||||
SCORE 59 Convert vacant warehouse building into a mixed use structure as per plans and 12-21487-vcgen:1st floor: 3 commercial spaces - 1) 2588 sq ft; 2) 2976 sq ft; 3) 2148 sq ft2nd & 3rd floor: 8 apartments each floor [apt 2a - 2h; apt 3a-3h]construct 4th floor addition: 4 apartments [apt 4a-4d]as per plans and bza 029-11. Permit type: Renovation (structural) | Permit status: Permit issued | Expiration date: January 23, 2014 | Current use: Business use | Permit id: 13-14874-Rnvs | |||||
SCORE 98 Moving equipment Date: January 12, 2015 Contractor: Thyssenkrupp Permit status: Permit issued | Expiration date: July 12, 2015 | Current use: Business use | Permit id: 15-00891-Movg | |||||
To carefully remove stair penthouse on chartres side of building & unpermitted mortar cap applied to rear property line wall, and to reconstruct stair penthouse and apply mortar cap using vcc approved mortar & stucco formula (below), replacing damaged bricks as necessary with like, soft red bricks, per brick sample submitted to vcc staff for review, per ac approval of 08 12 14, per survey submitted 07 29 14, per french market corporation authorization submitted 08 01 14, per structural engineers letter submitted 08 11 14, and per revised plans submitted 08 18 14, all stamped vcc approved 08 19 14. 1. Mortar: no more than 1 part portland cement, 3 parts lime, 9 parts sand, and enough water to form a workable mix. Prepackaged mixes are not permitted, as quality control is not consistent. Stucco: base coat consists of 2 coats, doubled up work of 5 8" total thickness. Proportioned as follows: no greater than 1:12 part portland cement, to 3 parts lime, and 9 parts sand, 6 lbs. Cubic yard ha Date: July 15, 2014 Permit type: Vcc general work | Permit status: Permit issued | Expiration date: February 19, 2015 | Current use: Business use | Permit id: 14-25780-Vcgen | |||||
519 wilkinson: ground-floor stucco walls..."cathedral gray", flat or satin finish exposed masonry walls.... To remain unpainted wooden elements including doors, windows, frames, shop windows (except ground-floor), fascia soffit outriggers ofblacony..., "shoji white" sw7042, semigloss shutters"isle of pines" sw6461,semigloss ironwork, gutter downspouts, tie-plates, ground-floor trim and millwork ..."urbane bronze" sw7048535 wilkinson: stucco walls..."shoji white" sw7042, semigloss wooden elements including doors, windows, frames, shop windows,ironwork, gutter downspouts, tie-plates..., "urbane bronze" sw7048, semiglossnote: no other work is approved under this permit. Verbal stop work order remains in effect on fourth-story penthouse. No painting or other work is currently approved for this level. Seperate application must be submitted for review and approval and shall be permitted seperately. Date: May 12, 2014 Permit type: Vcc paint | Permit status: Permit issued | Expiration date: December 13, 2014 | Current use: Business use | Permit id: 14-17850-Vcpnt | |||||
The following is approved in order to protect & preserve the permitted renovation work at 519-33 wilkinson street per vccs architectural committee approval of 09 27 11, vcc approval of 10 18 11, & plans submitted 07 31 12 & stamped vcc approved 08 07 12:1) installation of plate glass walls and doors in the fourth floor penthouse addition 2) installation of the base ply of the 2-ply modified bitumen roofing membrane system on the terraces3) repair and repointing to the masonry walls on both chartres and wilkinson elevations as needed using the vcc approved mortar formula (below)mortar: no more than 1 part portland cement, 3 parts lime, 9 parts sand, and enough water to form a workable mix. Prepackaged mixes are not permitted, as quality control is not consistent (i. E. No quikrete is allowed). Note: no other work is approved under this permit. The verbal stop work order (swo) issued 02 13 14 pertaining to the interior and exterior of the fourth-floor penthouse addition for work performed Date: May 6, 2014 Permit type: Vcc general work | Permit status: Permit issued | Expiration date: November 6, 2014 | Current use: Business use | Permit id: 14-14322-Vcgen | |||||
SCORE 98 Moving equipment Date: January 12, 2015 Contractor: Thyssenkrupp Permit status: Certificate of completion | Expiration date: July 12, 2015 | Current use: Business use | Permit id: 15-00891-Movg |