Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
To install one (1) double-faced wood sign to read "irenes cuisine" per drawings submitted on 11/18/15 & stamped vcc approved 12/11/15:sign will measure: 40"w x 24"h x 3/4" thicksign will hang from existing iron bracket perpendicular to the street, relocated from center of building to chartres side of front elevationsign will have a green background with white lettering and red borderno additional illumination or lighting is approved ![]() ![]() Permit type: Vcc sign | Permit status: Permit issued | Expiration date: November 11, 2016 | Current use: Business use | Permit id: 15-27860-Vcsgn | |||||
Install new gate at restaurant entrance to match existing in style, detailing, and color, per drawings stamped vcc approved 11/20/14. ![]() Permit type: Vcc general work | Permit status: Permit issued | Expiration date: May 20, 2015 | Current use: Business use | Permit id: 14-36401-Vcgen | |||||
Renovation of first floor commercial space for use as a restaurant, per plans received on 10/25/12 and stamped and approved by the vcc on 11/14/12, including the following: --construction of an entry vestibule within existing lakeside alley. Entry vestibule will be glass and wood with signage; --modification of millwork on ground floor of the bienville st. Elevation. Existing shutters will be removed and the river side bay on the ground floor will receive a new entry door. --installation of brick paving in the rear courtyard. --installation of mechanical vent for the kitchen equipment on the rear portion of the river side wall. Note: this permit also serves to satisfy the provisions for the change of use, as noted in article 8, section 8. 1 of the new orleans comprehensive zoning ordinance. ![]() ![]() Permit type: Vcc general work | Permit status: Permit issued | Expiration date: April 9, 2014 | Current use: Business use | Permit id: 13-40598-Vcgen | |||||
SCORE 97 Rebuild service 14-05505 ![]() ![]() Permit type: Electrical service / circuit / feeder | Permit status: Permit issued | Expiration date: January 22, 2015 | Current use: Mixed use | Permit id: 14-22782-Serv | |||||
Proposal for rear gallery addition for vcc conceptual approval, includes glass awning at side entry as well. Note: rear gallery denied by architectural committee 08/25/15. Approval for glass awning only. ![]() Permit type: Vcc general work | Permit status: Permit expired due to ina | Completion date: April 11, 2016 | Current use: Business use | Permit id: 15-24123-Vcgen | |||||
Renovation of first floor commercial space for use as a restaurant, per plans received on 10/25/12 and stamped and approved by the vcc on 11/14/12, including the following: --construction of an entry vestibule within existing lakeside alley. Entry vestibule will be glass and wood with signage; --modification of millwork on ground floor of the bienville st. Elevation. Existing shutters will be removed and the river side bay on the ground floor will receive a new entry door. --installation of brick paving in the rear courtyard. --installation of mechanical vent for the kitchen equipment on the rear portion of the river side wall. ![]() ![]() Permit type: Vcc general work | Permit status: Permit issued | Expiration date: May 14, 2013 | Current use: Business use | Permit id: 12-30587-Vcgen | |||||
SCORE 96 Supplemental permit to 13-04080-cuse due to changes in the kitchen that differ from what was originally approved. Permit type: Renovation (non-structural) | Permit status: Zoning review | Current use: Mixed use | Permit id: 14-05505-Rnvn | |||||
-install temporary signage for filming ![]() Permit type: Vcc general work | Permit status: Permit issued | Completion date: October 7, 2014 | Expiration date: August 28, 2013 | Current use: Business use | Permit id: 13-06089-Vcgen | |||||
Movie set construction ![]() Permit type: Vcc general work | Permit status: Permit issued | Completion date: October 7, 2014 | Expiration date: January 13, 2013 | Current use: Business use | Permit id: 12-18900-Vcgen | |||||
SCORE 97 Addition of new rear brick portico and wrought iron fence. New brick sidewalk to replace existing flagstone. Permit type: Renovation (structural) | Permit status: Application submitted | Current use: Business use | Permit id: 16-11936-Rnvs | |||||
SCORE 97 Sign for irenes cuisine at 529 bienville, attached to existing iron bracket. ![]() ![]() Permit type: Attached sign | Permit status: Permit issued | Expiration date: November 17, 2016 | Current use: Business use | Permit id: 15-27860-Satt | |||||
Non-structural exterior renovations to vacant commercial space - repair 2nd and 3rd floor metal balconies on bienville, and replace metal decking as per vcc permit # 13-05373-vcgen. No use and occupancy under this permit. Permit application for change of use is under 13-04080-cuse. ![]() ![]() Permit type: Renovation (non-structural) | Permit status: Permit issued | Expiration date: September 6, 2013 | Current use: Business use | Permit id: 13-07029-Rnvn | |||||
Revisions to facade fenestration per ac approval of 03/11/14, revised drawing received & stamped approved 3/17/14. Note: this permit serves as an addendum to vcc permit # 13-40598. ![]() Permit type: Vcc general work | Permit status: Permit issued | Expiration date: September 17, 2014 | Current use: Business use | Permit id: 14-08263-Vcgen | |||||
Addition of new rear brick portico and wrought iron fence. New brick sidewalk to replace existing flagstone. ![]() Permit type: Vcc general work | Permit status: Vcc arc meeting | Current use: Business use | Permit id: 16-11936-Vcgen | |||||
Ground-floor doors & windows (main building)... Sw "french quarter green"new lakeside addition double doors... Sw #36601 "tanager"new lakeside addition wood frame & cornice.... Sw "french quarter green"note: permit never picked up. (04/04/16) ![]() Permit type: Vcc paint | Permit status: Permit finaled | Completion date: October 10, 2014 | Expiration date: January 9, 2015 | Current use: Business use | Permit id: 14-21214-Vcpnt | |||||
SCORE 97 Construct rear gallery addition and glass awning at side entry as per plans. Permit type: Renovation (structural) | Permit status: Application submitted | Current use: Business use | Permit id: 15-24123-Rnvs | |||||
SCORE 86 3-waf/ 4-ac/ gas line/ 6-cooking equipment/ tankless water heater/ darryl341-8526/ ck13247/ 302/ 1304080-cuse ![]() ![]() Permit type: General mechanical | Permit status: Certificate of completion | Completion date: January 14, 2015 | Expiration date: March 24, 2015 | Current use: Business use | Permit id: 14-28941-Mech | |||||
Doors and windows: sw french quarter green (to match existing), semiglosstrim: bm hc-65 hodley red (to match existing), semiglossironwork: sw french quarter gree (to match existing), semiglossmoulding: bm hc-73 plymouth brown (to match existing), semigloss ![]() Permit type: Vcc paint | Permit status: Permit issued | Expiration date: June 19, 2017 | Current use: Business use | Permit id: 16-40387-Vcpnt | |||||
SCORE 89 3-waf 4-ac gas line 6-cooking equipment tankless water heater darryl341-8526 ck13247 302 1304080-cuse ![]() ![]() Permit type: General mechanical | Permit status: Certificate of completion | Completion date: January 14, 2015 | Expiration date: March 24, 2015 | Current use: Business use | Permit id: 14-28941-Mech | |||||
Vcc conceptual approval to construct 12-0" high wrought iron fence with gate in existing courtyard ![]() ![]() Permit type: Renovation (non-structural) | Permit status: Application submitted | Current use: Business use | Permit id: 16-39692-Rnvn | |||||
Construction of 12-0" tall iron fence ![]() Permit type: Vcc general work | Permit status: Materials resubmitted | Current use: Business use | Permit id: 16-39692-Vcgen | |||||
To install one (1) double-faced wood sign to read "irenes cuisine" per drawings submitted on 11 01 16 & stamped vcc approved 11 15 16:sign will measure: 40"w x 24"h x 3 4" thicksign will hang from existing iron bracket perpendicular to the street, relocated from center of building to chartres side of front elevationsign will have a green background with white lettering and red borderno additional illumination or lighting is approved ![]() Permit type: Vcc sign | Permit status: Permit issued | Expiration date: May 15, 2017 | Current use: Business use | Permit id: 16-36283-Vcsgn | |||||
SCORE 97 Install one (1) double-faced wood sign to read "irenes cuisine" per drawings submitted on 11 01 16 & stamped vcc approved 11 15 16: 40"w x 24"h x 3 4" thick; hung from existing iron bracket. No additional illumination or lighting is approved ![]() ![]() Permit type: Attached sign | Permit status: Permit issued | Expiration date: June 5, 2017 | Current use: Business use | Permit id: 16-36283-Satt | |||||
Revisions to facade fenestration per ac approval of 03 11 14, revised drawing received & stamped approved 3 17 14. Note: this permit serves as an addendum to vcc permit # 13-40598. ![]() Permit type: Vcc general work | Permit status: Permit issued | Expiration date: September 17, 2014 | Current use: Business use | Permit id: 14-08263-Vcgen | |||||
Renovation of first floor commercial space for use as a restaurant, per plans received on 10 25 12 and stamped and approved by the vcc on 11 14 12, including the following: --construction of an entry vestibule within existing lakeside alley. Entry vestibule will be glass and wood with signage; --modification of millwork on ground floor of the bienville st. Elevation. Existing shutters will be removed and the river side bay on the ground floor will receive a new entry door. --installation of brick paving in the rear courtyard. --installation of mechanical vent for the kitchen equipment on the rear portion of the river side wall. ![]() ![]() Permit type: Vcc general work | Permit status: Permit issued | Expiration date: May 14, 2013 | Current use: Business use | Permit id: 12-30587-Vcgen | |||||
Proposal for rear gallery addition for vcc conceptual approval, includes glass awning at side entry as well. Note: rear gallery denied by architectural committee 08 25 15. Approval for glass awning only. ![]() Permit type: Vcc general work | Permit status: Permit expired due to ina | Completion date: April 11, 2016 | Current use: Business use | Permit id: 15-24123-Vcgen | |||||
Ground-floor doors & windows (main building)... Sw "french quarter green"new lakeside addition double doors... Sw #36601 "tanager"new lakeside addition wood frame & cornice.... Sw "french quarter green"note: permit never picked up. (04 04 16) ![]() Permit type: Vcc paint | Permit status: Permit finaled | Completion date: October 10, 2014 | Expiration date: January 9, 2015 | Current use: Business use | Permit id: 14-21214-Vcpnt | |||||
Install new gate at restaurant entrance to match existing in style, detailing, and color, per drawings stamped vcc approved 11 20 14. ![]() Permit type: Vcc general work | Permit status: Permit issued | Expiration date: May 20, 2015 | Current use: Business use | Permit id: 14-36401-Vcgen | |||||
To install one (1) double-faced wood sign to read "irenes cuisine" per drawings submitted on 11 18 15 & stamped vcc approved 12 11 15:sign will measure: 40"w x 24"h x 3 4" thicksign will hang from existing iron bracket perpendicular to the street, relocated from center of building to chartres side of front elevationsign will have a green background with white lettering and red borderno additional illumination or lighting is approved ![]() ![]() Permit type: Vcc sign | Permit status: Permit issued | Expiration date: November 11, 2016 | Current use: Business use | Permit id: 15-27860-Vcsgn | |||||
Renovation of first floor commercial space for use as a restaurant, per plans received on 10 25 12 and stamped and approved by the vcc on 11 14 12, including the following: --construction of an entry vestibule within existing lakeside alley. Entry vestibule will be glass and wood with signage; --modification of millwork on ground floor of the bienville st. Elevation. Existing shutters will be removed and the river side bay on the ground floor will receive a new entry door. --installation of brick paving in the rear courtyard. --installation of mechanical vent for the kitchen equipment on the rear portion of the river side wall. Note: this permit also serves to satisfy the provisions for the change of use, as noted in article 8, section 8. 1 of the new orleans comprehensive zoning ordinance. ![]() ![]() Permit type: Vcc general work | Permit status: Permit issued | Expiration date: April 9, 2014 | Current use: Business use | Permit id: 13-40598-Vcgen | |||||
SCORE 97 Install two 18-ft commercial hood /fan . Dale chiasson (#2502) 504-915-689813-04080-cuse ![]() ![]() Permit type: Hoods | Permit status: Certificate of completion | Completion date: December 19, 2014 | Expiration date: November 8, 2014 | Current use: Business use | Permit id: 14-14582-Hood | |||||
Construct new fence and gate in rear yard ![]() Permit type: Vcc general work | Permit status: Voided - duplicate permit | Completion date: May 1, 2017 | Current use: Business use | Permit id: 17-13867-Vcgen | |||||
Sign permit on existing bracket. "irenes" (white) on green w gold-purple border. 44" x 23". Manufacture install (1) double sided high density urethane sign to existing sign bracket. ![]() Permit type: Attached sign | Permit status: Permit approved | Current use: Business use | Permit id: 17-32847-Satt | |||||
Sign permit on existing bracket. "irenes" (white) on green w gold-purple border. 44" x 23". Manufacture install (1) double sided high density urethane sign to existing sign bracket. ![]() Permit type: Vcc sign | Permit status: Permit issued | Expiration date: March 26, 2018 | Current use: Business use | Permit id: 17-32847-Vcsgn | |||||
SCORE 89 Looking to install a walk-in cooler and freezer in the rear courtyard are of the driveway behind the driveway fence. Walk-in cooler and freezer exterior panels will be painted french quarter green to blend in if gate is open although it will not be located in line of view. Dimensions of entire cooler and freezer are 22 foot long from bienville street toward conti st and foot wide from chartres st. To decatur st and is 8 foot 6 inches tall. Unit will tucked behind 106" wall that runs 6410" from the driveway gate towards the back of the location which is then another 64 to the property line towards the rear. Location is fenced off with a 15 tall brick wall. Condenser units for cooler and freezer will be set on top walk-in cooler and freezer cabinet and are both 18" tall with a weatherproof cover. Permit type: Renovation (non-structural) | Permit status: Application submitted | Current use: Business use | Permit id: 17-26256-Rnvn | |||||
Installation of a walk-in cooler and freezer in side yard of existing restaurant ![]() Permit type: Vcc general work | Permit status: Voided - duplicate permit | Completion date: September 27, 2017 | Current use: Business use | Permit id: 17-31925-Vcgen | |||||
New sign ![]() Permit type: Vcc sign | Permit status: Returned for revision | Current use: Business use | Permit id: 17-29030-Vcsgn | |||||
Construct new fence and gate in rear yard ![]() ![]() Permit type: New construction | Permit status: Application submitted | Current use: Business use | Permit id: 17-13867-Newc | |||||
SCORE 96 Install hanging sign as per drawing. ![]() ![]() Permit type: Attached sign | Permit status: Application submitted | Current use: Business use | Permit id: 17-29030-Satt | |||||
Installation of a walk-in cooler and freezer in side yard of existing restaurant ![]() ![]() Permit type: Accessory structure | Permit status: Application submitted | Current use: Business use | Permit id: 17-31925-Accs | |||||
SCORE 86 17-15506 rnvs ![]() ![]() Permit type: Electrical repair / replacement / addition | Permit status: Permit issued | Expiration date: January 27, 2018 | Current use: Business use | Permit id: 17-26075-Erpr | |||||
SCORE 97 Relocate existing bar withing existing restaurant as per plans. Permit type: Renovation (non-structural) | Permit status: Permit issued | Expiration date: December 7, 2017 | Current use: Business use | Permit id: 17-15506-Rnvn | |||||
Install new glass awning in chartres-side entry alley, per materials received 08 16 17 & stamped vcc approved 10 11 17. Note: violations cited under case 17-02159 resolved prior to permit issuance. ![]() Permit type: Vcc general work | Permit status: Permit issued | Expiration date: April 11, 2018 | Current use: Business use | Permit id: 15-24123-Vcgen | |||||
Work associated with the installation of exterior walk-in cooler freezer, per 09 26 17 committee approval & materials stamped vcc approved 10 11 17, as follows:install new walk-in cooler and freezer in the driveway on the decatur street side property line, behind the adjacent building. Cooler shall measure 22-8" x 10-6" x 8-6". Cooler roof must be medium gray color, white is not approved. Install associated compressors on the roof of the cooler out of line of sight. Install "seven-board fence" style wooden fence around cooler, measuring 9-0" tall, leaving a 3" air gap between the posts and cooler. Extend chartres-side of wall approx. 24-36" closer to bienville than shown in drawings to further obscure equipment. (see vcc notes on stamped drawings)paint seven-board fence french quarter green (semigloss). ![]() Permit type: Vcc general work | Permit status: Permit issued | Expiration date: April 11, 2018 | Current use: Business use | Permit id: 17-26256-Vcgen | |||||
SCORE 56 Repair 2nd and 3rd floor metal balconies on bienville st. Faade, per application and proposal received 1/30/13. Metal decking will be completely replaced on 2nd floor, left side balcony, and will be patched on 2nd floor, right side balcony. Both 3rd floor balconies will have holes drilled in existing metal decking to facilitate drainage where water currently stands. Permit type: Vcc general work | Permit status: Permit finaled | Completion date: October 10, 2014 | Expiration date: August 21, 2013 | Current use: Business use | Permit id: 13-05373-Vcgen |