Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Alteration permit ![]() Client: Wpre Inventory Llc | Permit status: Active | Permit id: 622449 | |||||
Alteration permit ![]() Client: Wpre Inventory Llc | Permit status: Expired | Permit id: 622449 | |||||
Alteration permit ![]() Client: Wpre Inventory Llc | Permit status: Active | Permit id: 713783 | |||||
SCORE 100 Install 5"lateral,house drain,curb trap,fai,stack,area drain,new 3 4" water service,2 toilets,2 lav,1 bath tub,1 kitchen sink and 1 laundry water box-pa1#20170872125-the installation will comply with the philadephia plubming code 2004 "self-certifications are no longer permitted" - "all excavations and plumbing trenches in excess of 5 feet in depth must have approved shoring in place at the time of inspection" ![]() ![]() Client: Wpre Iv Lp | Permit type: Plumbing permit | Permit status: Completed | Completion date: November 10, 2017 | Permit id: 770310 | |||||
SCORE 100 Install 1 hvac unit with ductwork (sfd) ![]() ![]() Client: Wpre Iv Lp | Permit type: Mechanical permit | Permit status: Completed | Completion date: November 10, 2017 | Permit id: 801433 | |||||
SCORE 100 Install 32 plug 9 gfci 12 sp switches 8-3 way switches 1-4 way switches 18 lights 2 fans 4 smoke detectors 4-co smoke detectors onto new 100amp service comnplete with panel, meter & grounding as per 2008 nec (west district) ![]() ![]() Client: Wpre Iv Lp | Permit type: Electrical permit | Permit status: Completed | Completion date: November 6, 2017 | Permit id: 802823 | |||||
SCORE 93 Make safe permit, remove deteriorated main roof system elements and replace with kind including rafters sheathing and roof covering membrane. Repair affected wall as necessary. Property shall be maintained from trespass. Windows and doors shall be in good repair. Upon final inspection violations #223208, #351798 & #482969 will be complied. Separate permit for alterations renovation are required. Post this permit post the project information sign ![]() ![]() Client: Wpre Iv Lp | Permit type: Alteration permit | Permit status: Expired | Completion date: November 14, 2016 | Permit id: 618201 | |||||
Make safe permit - for replacing rear wall and roof (no engineer? S report submitted) to resolve case #482969 & 223208. Abutting sidewalk must be closed with fencing a minimum of 6? In height. Separate streets department permit required for sidewalk closure. A separate permit is required for any additional alterations that are not specifically addressed on case #482969 & 223208. ![]() Client: Wpre Iv Lp | Permit type: Alteration permit | Permit status: Expired | Completion date: June 7, 2016 | Permit id: 622449 | |||||
SCORE 93 New roof c overing, windows, doors, stairs, insulationm non-structural partition walls, and finishes to be installed. Reolacement of approximately 15-16 floor joists on the second floor. Exisitng exterior walls to remain. Basement to remain unfinished but will be sealed andinsulated. Gross swuare footage and building footprint are unchanged. All utility connections ( inculudign water, sewer, gas, and electric) wiil be replaced. A 6 permimeter chain link fence will surround the rear yard. ![]() ![]() Client: Wpre Iv Lp | Permit type: Alteration permit | Permit status: Completed | Completion date: November 10, 2017 | Permit id: 713783 |