Content | Date | Cost | Contractor Rank | Address | Contractor |
---|---|---|---|---|---|
Wellington mhp Date: October 18, 2011 Permit status: Closed | Permit id: 11-05690 | |||||
SCORE 100 Wellington mhp Client: Wellington Mhp | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 11-05690 | Parcel: 95782 | |||||
SCORE 100 Wellington mhp Client: Wellington Mhp | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 11-05690 | Parcel: 95782 | |||||
SCORE 100 Wellington mhp Client: Wellington Mhp | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 11-05690 | Parcel: 95782 | |||||
October 3, 2011 12:44:47 pm kneel. Permit on hold for site plan. October 3, 2011 4:03:53 pm kneel. Received site plan. October 3, 2011 12:41:19 pm kneel. Wellington mhp - used mh to lot location: airport rd to wellington mhp; october 18, 2011 9:23:54 am kneel. Wellington mhp - used mh to lot; to request residential inspections call redacted phone number: manufacturers installation manual must be on site for inspection. Use manual on pier and anchor strap spacing. If manufacturer set up requires footings, then a footing inspection is necessary prior to placing concrete. First tie down max 2 ft from end of "i" beam, unless manufacturer specs are otherwise. If more than 25% of unit is over 3 above grade tie-downs & pier spacing are to be designed by a engineer. Stairs required at all exist doors. If the top stair is greater than 30" above grade then a handrail is required on both sides of steps. Solid blocks are required if leveling steps is needed. Deck & landing larger than 5 square f Permit type: Permits - historical | Permit status: Closed | Permit id: 11-05690 | Parcel: 95782 | |||||
Wellington mhp Date: October 18, 2011 Value: $7,000 Permit type: Historical | Permit status: Closed | Permit id: 11-05690 | |||||
SCORE 100 Wellington mhp Client: Wellington Mhp | Permit type: Permits - historical | Permit status: Closed | Current use: Historical | Permit id: 11-05690 | Parcel: 95782 | |||||
October 3, 2011 12:44:47 pm kneel. Permit on hold for site plan. October 3, 2011 4:03:53 pm kneel. Received site plan. October 3, 2011 12:41:19 pm kneel. Wellington mhp - used mh to lot location: airport rd to wellington mhp; october 18, 2011 9:23:54 am kneel. Wellington mhp - used mh to lot; to request residential inspections call redacted phone number: manufacturers installation manual must be on site for inspection. Use manual on pier and anchor strap spacing. If manufacturer set up requires footings, then a footing inspection is necessary prior to placing concrete. First tie down max 2 ft from end of "i" beam, unless manufacturer specs are otherwise. If more than 25% of unit is over 3 above grade tie-downs & pier spacing are to be designed by a engineer. Stairs required at all exist doors. If the top stair is greater than 30" above grade then a handrail is required on both sides of steps. Solid blocks are required if leveling steps is needed. Deck & landing larger than 5 square f Date: October 18, 2011 Permit type: Permits - historical | Permit status: Closed | Permit id: 11-05690 | Parcel: 95782 |